Accepted Manuscript A porous and luminescent metal-organic framework containing triazine group for 2+ sensing and imaging of Zn Tianen Fan, Tifeng Xia, Qi Zhang, Yuanjing Cui, Yu Yang, Guodong Qian PII:
S1387-1811(18)30115-X
DOI:
10.1016/j.micromeso.2018.02.050
Reference:
MICMAT 8813
To appear in:
Microporous and Mesoporous Materials
Received Date: 10 November 2017 Revised Date:
8 February 2018
Accepted Date: 27 February 2018
Please cite this article as: T. Fan, T. Xia, Q. Zhang, Y. Cui, Y. Yang, G. Qian, A porous and luminescent 2+ metal-organic framework containing triazine group for sensing and imaging of Zn , Microporous and Mesoporous Materials (2018), doi: 10.1016/j.micromeso.2018.02.050. This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
ACCEPTED MANUSCRIPT
Graphical abstract A porous and luminescent metal-organic framework
RI PT
containing triazine group for sensing and imaging of Zn2+ Tianen Fan, Tifeng Xia, Qi Zhang, Yuanjing Cui*, Yu Yang, Guodong Qian*
A porous and luminescent lanthanide metal-organic framework, TbTATB, for
SC
sensing and imaging of Zn2+ was successfully synthesized. TbTATB exhibits
M AN U
selective and sensitive detection of Zn2+ even in the present of other relevant metal ions with the detection limit of 10.5 nM. Furthermore, TbTATB could
AC C
EP
TE D
perform as the marker of Zn2+ with the coexist of living cells.
ACCEPTED MANUSCRIPT
A porous and luminescent metal-organic framework containing triazine group for sensing and imaging of Zn2+ Tianen Fan, Tifeng Xia, Qi Zhang, Yuanjing Cui*, Yu Yang, Guodong Qian*
RI PT
State Key Laboratory of Silicon Materials, Cyrus Tang Center for Sensor Materials and Applications, School of Materials Science and Engineering, Zhejiang University, Hangzhou, 310027, P. R. China. E-mail:
[email protected],
[email protected]
Abstract: The rapid development of functionalization of lanthanide metal organic frameworks (Ln-MOFs) offers the potential for biomarkers sensing. It is closely associated with biology science and clinic medicine. In this work, a porous and luminescent terbium metal-organic
SC
framework TbTATB has been designed and solvothermally synthesized. The PXRD results demonstrated the commendable stability of this sensor. Enhanced luminescence of TbTATB origin from Tb3+ was observed in the presence of Zn2+, which is a kind of biologically importmant ion. This turn-on pattern was ultilized for sensing Zn2+. TbTATB exhibited excellent sensitivity and slectivity towards Zn2+ in aqueous solution with
M AN U
the detection limit of 10.5 nM. What’s more, it has fairly acceptable biocompatibility which was fully verified by cytotoxicity test. In the state of coexistence with living cells, visible increased green light of TbTATB emerged after the addition of Zn2+, while the survival state of cells was hardly disturbed. Markedly, this is the first time that a luminescent Tb-MOF can act as a sensor for sensing and imaging of Zn2+ ions simultaneously. What’s more, the results also guide a new application direction of MOFs and supply a new way for the detection of other analytes in biological systems.
TE D
Key words: metal-organic frameworks, turn-on, luminescent, sensing, imaging
1. Introduction 2+
numerous
EP
Zinc (Zn ) is recognized to play pivotal roles in fundamental
biological
processes
AC C
covering enzyme regulation, gene expression, nerve transmission and cell apoptosis in living systems [1]. Owing
to
the
unique
10
3d 4s
0
electronic
luminescent signals, stabilized and time-dependent luminescence signals could be obtained. It has been developed
in
detection fields
and
possesses
superiorities such as conveniences, good sensitivity, excellent selectivity, rapid response and noninvasive 2+
sensing [3]. Generally, a luminescent Zn 2+
contains two essential parts: Zn
sensor
chelating or
2+
configuration, Zn exists in the +2-oxidation state in the living systems and shows no spectroscopic or magnetic
signals
[2].
Recently,
luminescence
techniques have increased our insight into more possibilities to look into this biologically important
binding moieties and luminescent centers capable of emitting light [4]. To date, several organic fluorophores sensors have been developed for Zn
2+
detection, such as quinolone and coumarin [5-8]. However, there are some imperfections including
ion. Based on monitoring the change of the
1
Please do not adjust margins
Please do not adjust margins
ACCEPTED MANUSCRIPT intricate synthetic route, weak luminescence, short
turn-off sensors, as they can effectively avoid false
luminescent lifetime and poor biocompatibility,
response and obtain a better signal-to-noise ratio.
leading to strong desire of developing new sensors
The quenching effect might be caused by a series of
to overcome these problems [9].
environment and instrument factors which brings difficulties to analyze the actual contributor [28-29].
novel crystallographic porous materials which can
Therefore, there is thereby an urgent need but it is
be synthesized by simply self-assembly process with
still a significant challenge to seek functional Ln-
corresponding metal cations or clusters and organic
MOFs
ligands [10-11]. They have attracted more and more
biocompatibility to achieve the purpose of highly
attention due to the peculiarities including simple
selective and sensitive sensing and imaging of Zn
synthetic method, modifiable pore size, designable
in biological systems.
and
unique
luminescent
good
water-stability
and
2+
SC
sites
with
Considering the unique luminescent properties of
M AN U
functionalized
RI PT
In the past few decades, MOFs are emerging as
properties [12-15]. Particularly, lanthanide MOFs
terbium and the fact that terbium is preferential to
(Ln-MOFs) can exhibit intense, long-lived emission
coordinate
in the visible region, which are applicable for
incorporation of carboxyl groups into the ligand
luminescent sensing and imaging [16-22].
should be a feasible approach. In addition, Zn
with
the
oxygen
atoms,
the
2+
has
Up to now, several luminescent MOFs sensors for
strong coordination ability with nitrogen atoms, a
2+
ligand
have been reported [23-24]. However, most of
TE D
Zn
containing
2+
Consequently, a trigonal-planar organic ligand
from inferior stability and poor biocompatibility,
4,4',4''-striazine-2,4,6-triyl-tribenzoic acid (H3TATB)
EP
mechanism. In addition, MOFs are usually suffering
imaging in biological systems
AC C
2+
Zn
supply
functionalized
application for Zn
for
might
them are based on the luminescence quench
which restrict the detection conditions and the
sites
triazine
sensing
[30].
was chosen as the ligand to construct a luminescent MOF with terbium. As expected, within the 3+
[25]. As is well-known, Imaging of analytes in
synthesized framework TbTATB, all the Tb ions are
biological environments is a critical strategy for the
coordinated by oxygen atoms, leaving abundant
discovery and treatment of disease. And with the
exposed
development
selectivity
of
microscopic
techniques,
Lewis and
basic
sites.
sensitivity
Meanwhile,
were
studied
the by
luminescent sensors supply new aspects that we
luminescence
could see the direct-viewing distribution of analytes
Furthermore, the biocompatibility of TbTATB was
in
Moreover,
evaluated by MTT test. And subsequent imaging
luminescent turn-on sensors are preferable than
experiments with living cells were also conducted.
biological
systems
[26-27].
2
Please do not adjust margins
spectra
in
aqueous
solutions.
ACCEPTED MANUSCRIPT As anticipated, the as-developed Ln-MOF TbTATB is
Fourier maps in the refinement cycles. The scattering
demonstrated to have favorable accuracy and
from the highly-disordered lattice guest molecules were
2+
repeatability for Zn sensing. Moreover, it might be potentially applied for imaging of Zn
2+
in biological
systems.
removed using the SQUEEZE procedure implemented in the PLATON package. Selected crystal parameters, data collection, and refinement are summarized in Table S1. 1582634
contains
the
supplementary
RI PT
CCDC
2. Experimental
crystallographic data for this paper. Elemental analyses were performed on a Thermo Finnigan Flash EA 1112
2.1 Materials and characterization
element analyzer. Powder X-ray diffraction (PXRD) data
reagents were purchased from commercial sources and used without further purification. Bruker SMART APEX-II
detector
was
employed
to
diffractometer (Japan) using Cu-Kα (λ= 1.542 Å) beam o
with the recording rate 5 /min with the 2θ ranging from
M AN U
single crystal diffractometer (Germany) with a CCD
were collected on a PANalytical X'Pert Pro X-ray
SC
All the initial chemicals, including solvents and
implement
the
crystallographic measurements for TbTATB, using
graphite-monochromatic Mo Kα radiation (λ= 0.71073 Å) at 296 K. CrysAlisPro was used to conduct the
TE D
determination of the unit cell and data collection. The
data reduction was carried out with Bruker SAINT. The
data sets were corrected by empirical absorption
correction using spherical harmonics, implemented in
EP
the SCALE3 ABSPACK scaling algorithm. The cell parameters determination and date collection was
3 to 40 degrees at 293 K. Thermogravimetric analyses (TGA) were carried out on a Netzsch TG209F3(Germany) -1
with a heating rate of 10 K min under N2 atmosphere. X-ray photoelectron spectroscopy (XPS) studies were carried out on an AXIS SUPRA instrument with an Al Kα monochromated (150 W) and delay line detector. The samples were charge-neutralized using a coaxial fully automatic single electron source charge neutralizer and tested under the identical condition. Spectra were analysed using ESCApe software. The C1s signal at 285 eV was used to calibrate the binding energy scale.
AC C
performed directly by CrysAlisPro program. The crystal structure was determined by direct methods and refined by the full-matrix least-squares method with the SHELX-2014 program package. All non-hydrogen atoms were located successfully from Fourier maps and were refined anisotropically. The H atoms on the ligands were placed in idealized positions and refined using a riding model. The disordered lattice DMA, EtOH, and H2O
2.2 Synthesis of TbTATB
A mixture of Tb(NO3)3∙6H2O (70mg, 0.15mmol), 4,4'4''-striazine-2,4,6-triyl-tribenzoic acid (H3TATB) (30mg, 0.068mmol), DMA (10mL), EtOH (3.5mL), H2O (1.0mL) and CH3COOH (100μL) were sealed into a 20mL glass vial and ultrasonically dissolved to from clarified o
solution. Then the vial was heated at 105 C for 24
molecules could not be located successfully from
3
Please do not adjust margins
Please do not adjust margins
ACCEPTED MANUSCRIPT hours, then cooled to room temperature, yielding
were observed upon excitation at 356 nm. The emission
colourless rhombus crystals. Yield: 75.4%. The crystals
and excitation spectra for the samples were recorded in
were collected by filtration and washed with DMA and
suspension state. Suspension could almost remain
EtOH for several times, respectively. Then the crystals
homogeneous within the test time. Triplicate operations
o
for all samples were performed to maintain more
were reserved for PXRD test and other experiments.
accurate results.
2.3 N2 sorption experiments
2.5 Biocompatibility test
RI PT
were drying in a 60 C oven overnight, the dried samples
2.5.1 Cell Culture: The rat pheochromocytoma (PC12)
TbTATB, the N2 sorption experiment was carried out
cells were incubated in Dulbecco’s Modified Eagle’s
with the Micromeritics ASAP 2020 surface area analyzer.
Medium (DMEM, Neurons) with 10% fatal bovine serum
Before the N2 sorption measurements, the fresh sample
(FBS) and 1% penicillin/streptomycin (P/S, Boster) for 2
M AN U
SC
In order to evaluate the permanent porosity of
of TbTATB was guest-exchanged with dry methyl
days in a humidified incubator (37 °C, 5% CO2). 2.5.2 MTT Test: The biocompatibility of TbTATB was
was freshly exchanged every four hours. Then, the
evaluated by using standard MTT assay in a 96-well
volatile methyl alcohol was removed under vacuum at
plate to assess the viability of cultured cells. Firstly, cells
100 °C. Then filtered and degassed at 298 K for 12 hours
were incubation in the humidified incubator for 24h,
and 348 K for 12 hours under high vacuum to obtain the
and then TbTATB were added to the wells with different
activated TbTATBa.
concentrations (5, 20, 50, 80 and 100 μg/mL) and
EP
2.4 Luminescence study
TE D
alcohol for two days. During this period, methyl alcohol
The emission and excitation spectra and luminescent lifetime for the samples were recorded on an Edinburgh FLSP900
luminescence
AC C
Instrument
spectrometer
(England), Xe lamp and μF Flashlamp are severally used as the light source. The samples of TbTATB were grinded before experiment, then 1 mg TbTATB was weighed and added to several cuvettes containing 1 mL 2+
different concentrations of Zn
solutions prepared in
deionized water, respectively. Same operations were
incubated with the PC12 cells for another 4h in the incubator. After that, 50 μL of 1× MTT solutions were added to each tested well and incubated for 4h. Subsequently, all media were removed, and 150 μL of dimethyl sulfoxide (DMSO) was added to each well. Finally, the absorbance of each sample at 490 nm was measured using a microplate reader. The cell viability was calculated as the ratio of the absorbance of the sample well to that of the cell control and expressed as a percentage. All experiments were sextuplicated, and the results were averaged.
conducted for different metal ions. After dispersed ultrasonically for one minute, the florescence properties
4
Please do not adjust margins
ACCEPTED MANUSCRIPT 2.6 Optical imaging experiments
Optical imaging of PC12 cells was taken on by an optical microscope at room temperature. Bright field and luminescent field with excitation wavelengths of 4
365 nm were taken. The cells (10 cells/mL) were
-3
RI PT
seeded in a 24-well plate at the bottom of each well for 2+
24h incubation. Then 10 M Zn and 50 μg/mL TbTATB were added to the wells and incubated for another 4h,
out using an optical microscope with a 20× objective at room temperature. Both luminescent and bright-field
M AN U
images of PC12 cells were recorded.
SC
respectively. Luminescence imaging of cells was carried
3. Results and discussion
3.1 Preparation and characterization of TbTATB
The luminescent sensor was acquired by reacting
TE D
Tb(NO3)3∙6H2O with H3TATB in a mixed solvent of N,N-
dimethyl acetamide (DMA), ethyl alcohol (EtOH),
deionized water (H2O) and acetic acid (CH3COOH) at a o
EP
105 C oven for 24 hours. The crystal structure of TbTATB is shown in Figure 1b. Single-crystal X-ray
AC C
diffraction (SCXRD), elemental analysis (EA) and thermo gravimetric analyses (TGA) were employed to identify
Figure 1 a) Coordination mode of TATB
3-
ligands. b)
3+
Coordination mode of Tb . c) Crystal structure of TbTATB viewed along the b axis. (Tb green, C gray, O red, N blue; all H atoms are omitted for clarity) and d) PXRD patterns of synthesized TbTATB and TbTATB immersed in H2O for 8 hours.
the formula [Tb(TATB)(DMA)(H2O)]·(DMA)3. Elemental analysis calcd (%) for TbTATB: C 49.85,H 5.23,N
ligand, one coordinated DMA molecule and one H2O
10.17 ; Found: C 48.54 , H 5.19 , N 9.97. SCXRD
molecule. All the Tb
analysis displayed that TbTATB crystallizes in the
eight oxygen atoms, in which six are from H3TATB
monoclinic space group C2/c (Figure 1 and Table S1). The
unit
cell
of
TbTATB
consists
of
crystallographically unique Tb (III) ions, one TATB
3-
one
3+
ions are eight-coordinated by
ligands and the other two from the coordinated DMA molecules and H2O molecules, respectively. The three carboxylate groups in ligand show two different
5
Please do not adjust margins
Please do not adjust margins
ACCEPTED MANUSCRIPT coordination modes: syn–syn bridging bidentate and
PXRD patterns in Figure 1c exhibit that the structure of
chelating-bridging tridentate, as shown in Figure 1a. The
TbTATB
3+
unchanged
after
immersed
in
ions coordinated with carboxylate
deionized water for 8 hours. Therefore, the relatively
groups to form the secondary building unit (SBU)
good stability of TbTATB endows it with the possibility
Tb2(COO)6. Then the SBUs are packed together to form
to be a commendable sensor material in aqueous
3D framework structures with unique pores through the
solutions.
ligands, as shown in Figure 1c. The phase purity and 3.3 Detection of Zn water-stability of synthesized TbTATB were further
2+
RI PT
two adjacent Tb
remains
The dried TbTATB crystals were firstly grinded into
in Figure 1d. The porous property of TbTATB was
fine and uniform powder to guarantee homogeneous
revealed by N2 sorption studies (BET surface area:
dispersion in water. Then the obtained powder was
2
−1
SC
confirmed by powder X-ray diffraction (PXRD), as shown
simply immersed in an aqueous solution with different
429.86 m g , Figure S8).
M AN U
2+
Zn concentration to form suspension for luminescence
3.2 Luminescent properties
studies.
The luminescent properties of solid H3TATB and
It
is
worthwhile
mentioned
that
the
luminescence emission intensity of TbTATB was 2+
gradually enhanced with the Zn
be seen from Figure S2, under UV light excitation, the
increasing from 0 to 10 μM (Figure 2a). Specially, the D4
free H3TATB ligand molecules can absorb photons with
→ F5 transition of Tb present visible green light at 544
appropriate energy, the luminescence emission at about
nm with the highest intensities. The increasing effect
430 nm is resulted from π → π* transition, namely
can be fitted by the following equation, I/I0= 1 +
radiative transition from the first singlet state to the
KSV[Zn ], where I0 and I are independently the
ground
singlet
EP
TE D
TbTATB were measured at room temperature. As can
state.
TbTATB
5
showed
7
strong 3+
characteristic transitions ( D4 → FJ, J = 6−3) of Tb
7
concentration 5
3+
2+
luminescence intensity of the suspension at 544 nm in 2+
the absence and presence of Zn , KSV represents the
494, 544, 587, and 622 nm, without the emission of
increasing constant, and [Zn ] is the Zn concentration
H3TATB. The luminescent phenomenon of TbTATB
of the suspension. As can be seen from Figure 2b, there
suggests that the ligand-to-metal energy transfer
is an excellent linearity between I/I0 and [Zn ] at a
AC C
at
3+
(LMET) from H3TATB molecules to Tb
centers occur
2+
2+
2+
specific concentration range, which is indicative of the 2+
effectively [31]. Interestingly, identical characteristic
sensitive sensing properties of TbTATB towards Zn
emission bands were obtained in the suspension of
aqueous solutions.
TbTATB (Figure S4) in deionized water (1mg/mL) compared with solid state (Figure S3). Moreover, the
6
Please do not adjust margins
in
ACCEPTED MANUSCRIPT Consequently, the LOD of TbTATB sensor was evaluated through the equations below,
/ (1)
RI PT
∑
(2)
where Sb is the standard deviation of the multiple
SC
detection signals of the blank solutions (N = 20), S is the slope of the fitting line in Figure S4, F0 is the
M AN U
luminescence emission intensity of TbTATB in deionized 2+
water without Zn and F is the mean of F0. On the basis
Figure 2 a) The luminescent emission spectra (excited at
of the above method, the LOD was assessed to be 10.5
356 nm) of TbTATB in solutions (1mg/mL) with different
nM, which is even lower than the minimum standard
2+
Zn
concentrations and b) Stern-Volmer plots of I/I0 2+
TE D
versus Zn concentration and the fitting line in aqueous solution.
To further judge the sensitivity of the luminescent
2+
level of Zn in serum.
Interference from other metal ions should be taken
into
account
when
considering
physiological
applications. In order to confirm the sensing selectivity of TbTATB to Zn
2+
among other ions, TbTATB was
immersed in the aqueous solutions (1mg/mL) containing
calculated. LOD reflects the minimum concentration of
several different kinds of metal ions including Al , Mn ,
the analyte to be measured in a sample by a certain
Ni , Mg , Co , Na , Ca , Cr , Pb
AC C
EP
sensor TbTATB, the detection limit (LOD) of TbTATB was
3+
2+
2+
2+
+
2+
3+
2+
and Cd
2+
2+
to get
analytical method in a given degree of reliability. In
suspensions (10 μM) for luminescence studies under
accordance
identical conditions. The luminescence properties are
with
the
requirements
set
by
the
international federation of pure and applied chemistry
recorded and compared.
(IUPAC), the general value of signal-to-noise ratio for
As shown in Figure 3a, the luminescent intensity of
spectrochemical analysis is recommended as 3. As can
TbTATB incorporated with the metal ion is tightly
be seen in Figure S5, variation in luminescent intensity is
concerned with the varieties of the metal ions. Only the
linearly
dependent
on
2+
Zn
amount
at
low
2+
addition of Zn
caused a significant increase of
concentrations from 0 to 1 μM.
7
Please do not adjust margins
Please do not adjust margins
ACCEPTED MANUSCRIPT 2+
luminescent intensity, whereas other metal ions have a
TbTATB is a highly sensitive Zn
neglected impact on the luminescence intensity.
doesn’t suffer from the interference of other metal ions.
sensing material and
The conceivable mechanism for the turn-on and selective sensing of Zn
2+
will be summarized below. 3+
Generally, the luminescence intensity of Tb
is closely
RI PT
associated with the LMET efficiency [32-33]. Owning to the strong coordination abilities with N, the electron2+
deficient Zn
is supposedly available for interactions
with abundant Lewis basic pyridyl sites in the ligands
SC
[34]. The specific interactions can not only make the 3+
energy transfer process from H3TATB to Tb
more
M AN U
effective, leading to enhanced luminescence intensity, but also distinguish Zn
2+
from other metal ions,
exhibiting high selectivity [35-37]. Besides, the unique pore structure is beneficial for the interaction between 2+
Zn
and N atoms in ligands. In accordance with the
results of luminescence spectra, the luminescent
TE D
Figure 3 a) The luminescence intensity histograms of TbTATB dispersed in deionized water with the addition of different metal ions (10 μM) and b) subsequent 2+
addition of Zn ion (red, 10 μM). Emission intensities at 5
7
EP
the D4 → F5 transition were selected.
lifetime of TbTATB increased from 488 μs to 500 μs in 2+
the absence and presence of 10 μM Zn , as shown in Figure S6 and Table S2. 2+
To further confirm the bond mode between Zn and nitrogen atoms, X-ray photoelectron spectroscopy (XPS) studies were conducted. As shown in Figure 4, The N1s
2+
AC C
In detail, except for the slight increase for Cd , the others show a luminescence intensity decrease. To 2+
deeply evaluate the selectivity of TbTATB to Zn , the luminescence spectra were measured in the coexistence 2+
of Zn and other ions. As can be seen from Figure 3b, there is little change in increasing efficiency with the coexistence of other metal ions as compared with that 2+
in the presence of single Zn . The results indicated that
8
Please do not adjust margins
ACCEPTED MANUSCRIPT Figure 4 XPS spectra of the original TbTATB (black) and 2+
nature to culture plate and the unique morphology with
Zn -incorporated TbTATB (red) immersed in 10 mM
enriched neurites that reflects their living state, which
deionized H2O solution of Zn(NO3)2.
are beneficial to the observation by microscopy [39]. The cell viability was characterized by the amount of mitochondrial in viable cells. Owing to the ability to the
MTT
into
formazan,
mitochondria
RI PT
reduce
metabolism of the cells could be reflected by the decline of MTT to formazan [40-41]. Therefore, the MTT assay was conducted by incubating PC12 cells with TbTATB at
Figure 5 Simplified schematic of ligand-metal energy
The dose response of TbTATB on PC12 cells exhibits decreased MTT reduction to formazan with the growing
M AN U
transfer (LMET) process for luminescence emission and
SC
different does (5, 20, 50, 80 and 100 μg/mL) for 24 h.
concentration of TbTATB. As shown in Figure 6, there is
2+
influence of Zn on LMET.
a slight decrease of the cell viability with the increase of
peak of nitrogen atoms from pyridyl at 399 eV in 2+
TbTATB is shifted to 398.5 eV on the addition of Zn ,
demonstrating a weak binding of nitrogen atoms with 2+
TE D
2+
Zn in Zn -incorporated TbTATB [38]. A peak at 407.2 2+
eV in the N1s XPS spectra for Zn -incorporated TbTATB 3-
is attributed to NO counterions. The observed changes
EP
in the XPS spectral profile of TbTATB supported the 2+
participation of nitrogen in the complexation with Zn ,
maintains at about 100% after incubating with TbTATB
sensor at 50 μg/mL. It is indicative that the introduction of low-concentration MOFs can barely influence the viability of PC12 cells. For more visualized results, the optical microscopy imaging was also used to monitor the living state of cells and luminescence properties of TbTATB both in the
bright filed and luminescent field with 365nm UV light
AC C
which affects the energy transfer process from H3TATB
the TbTATB concentration, while the viability of cells
3+
to Tb , resulting in the improvement of LMET efficiency, as shown in Figure 5.
3.5 Imaging of Zn
To
further
2+
evaluate
the
biocompatibility
and
biological application of TbTATB, MTT assay and optical microscopy imaging under cell atmosphere were employed. PC12 cells was chosen for the adhesion
9
Please do not adjust margins
Please do not adjust margins
ACCEPTED MANUSCRIPT Figure 6 Cell viability data of MOFs obtained from
cells show desirable appearance of neurites emitting
cultured cells with the untreated cell as a control. Error
compared with the control cells. What’s more, TbTATB
bars represent the standard deviation of uncertainty for
perform visible green light under 365 nm UV light
each point.
excited at the cell atmosphere (Figure 7c). Many MOFs clusters are observed as green dots and accumulated
RI PT
around the cells. The co-localized luminescence signals indicated that there were no appreciable changes on the state, morphology, and long stretching microtubular of PC12
SC
cells after the introduction of TbTATB, demonstrating the good biocompatibility of TbTATB even at a relatively 2+
give
M AN U
high concentration. Subsequent addition of Zn
rise to a brightness enhancement without affecting the
living state of PC12 cells (Figure 7d). The turn on effect
Figure 7 Optical microscopy images of PC12 cells a) without treatment, b) incubated with 10
-3
2+
M Zn , c)
-3
2+
TE D
incubated with 50 mg/mL TbTATB and d) subsequent
addition of 10 M Zn . Optical bright field microscopy image for a1, b1, c1 and d1, optical luminescent field
microscopy image illuminated with 365nm light for a3,
EP
b3, c3 and d3, overlapped for a2, b2, c2 and d2.
in the cell environments agrees well with the phenomenon that was discovered in the luminescence
study. The results indicate that TbTATB is biocompatible
among neuron survival and neurite outgrowth owing and neurite outgrowth owing to the enriched neurites. Meanwhile,
exhibited
TbTATB
coincident
luminescence properties with the spectra study. On account
of
good
biocompatibility
and
unique
luminescence properties, TbTATB could be an excellent
AC C
excited. As shown in Figure 7, the PC12 cells attach candidate for turn-on luminescent sensing and imaging
closely to the substrate and show abundant growth of
2+
of Zn .
axons and dendrites in the absence of both TbTATB and 2+
Zn
(Figure 7a). There is slight influence on both
4. Conclusions
morphology and amount on PC12 cells on addition of 2+
Zn
with the concentration of 10
-3
M (Figure 7b).
Afterwards, on the basis of the MTT results, 50 μg/mL
In conclusion, we have successfully designed and synthesized a luminescent terbium metal-organic 2+
was
chosen
as
the
concentration
for
imaging
framework TbTATB for Zn
sensing and imaging. 2+
experiment. In the case of 50 μg/mL TbTATB, the PC12
TbTATB exhibited not only high selectivity for Zn over
10
Please do not adjust margins
ACCEPTED MANUSCRIPT other
competitive
metal
ions
with
increasing
[5]
P. Hu, R.Wang, L. Zhou, L. Chen, Q. Wu, M. Han,
luminescent intensity but also high sensitivity with the
A.M. El-Toni, D. Zhao and F. Zhang, Anal. Chem. 89
detection limit of 10.5 nM in aqueous solution.
(2017) 3492-3500.
Moreover, TbTATB has good biocompatibility so that it
[6]
2+
N. Lin, Q. Zhang, X. Xia, M. Liang, S. Zhang, L. Zheng and Q. Cao, RSC Adv. 7 (2017) 21446-
of living cells. This sensitive and selective sensor has the
21451.
in
[7]
biological systems. More significantly, this work would offer new possibilities for the design and use of stable
27 (2017) 357-367. [8]
lanthanide MOFs for sensing and imaging analytes in biological systems.
M.S. Kim, T.G. Jo, H.M. Ahn and C. Kim, J Fluoresc
K.B.Kim, H. Kim, E.J. Song, S. Kim, I. Noh, C. Kim, Dalton Trans 42 (2013) 16569-16577.
[9]
SC
2+
potential to serve as a powerful indicator for Zn
RI PT
could carry out the goal of imaging Zn with the coexist
S. Lohar, S. Pal, M. Mukherjee, A. Maji, N. Demitri and P. Chattopadhyay, RSC Adv. 7 (2017) 25528-
M AN U
Acknowledgements
25534.
This work was supported by the National Natural Science Foundation of China (Nos. 51432001,
51472217, 51772268, 516320008, U1609219, and
TE D
[1]
(2012), 1126-1162.
[11] J. Zhang, D. Yue, T. Xia, Y. Cui, Y. Yang, G. Qian, Microporous Mesoporous Mater. 253 (2017) 146-
61721005).
References
[10] Y. Cui, Y. Yue, G. Qian and B. Chen, Chem. Rev. 112
150. [12] Y. Li, Y. Zhao, P. Wang, Y. Kang, Q. Liu, X. Zhang and W. Sun, Inorg. Chem., 55 (2016) 11821-11830.
K.P. Carter, A.M. Young and A.E. Palmer, Chem.
[13] D. Zhao, X. Liu, Y. Zhao, P. Wang, Y. Liu, M. Azam,
[2]
EP
Rev. 114 (2014) 4564-4601.
S.I. Al-Resayes, Y. Lu and W. Sun, J. Mater. Chem.
J.B. Barnett, M.C. Dao, D.H. Hamer, R.Kandel, G. A, 5 (2017) 15797-15807.
AC C
Brandeis, D. Wu, G.E. Dallal, P.F. Jacques, R. [14] Z. Liu,Y. Zhao,Y. Deng,X. Zhang,Y. Kang,Q.
Schreiber, E. Kong and S.N. Meydani, Am. J. Clin. Lu and W. Sun, Sensors Actuators B: Chem., 250
Nutr. 103 (2016) 942-951.
[3]
(2017) 179-188.
K. Muller-Buschbaum, F. Beuerle, C. Feldmann, [15] Z. Liu, Y. Huang and W. Sun, Chinese J. Inorg.
Microporous Mesoporous Mater. 216 (2015) 171Chem. 33 (2017) 1959-1969. 199. [16] Y. Cui, B. Chen and G. Qian, Coord.Chem.Rev. 76 [4]
P. Jiang and Z. Guo, Coord. Chem. Rev. 248 (2004) (2014) 273-274. 205-229.
11
Please do not adjust margins
Please do not adjust margins
ACCEPTED MANUSCRIPT [17] B. Li, H. Wen, Y. Cui, G. Qian and B. Chen, Prog.
[31] N. Arnaud, E. Vaquer and J. Georges, The Analyst 123 (1998) 261-265.
Polym. Sci. 48 (2015) 40-84. [18] Y. Cui, B. Li, H. He, W. Zhou, B. Chen and G. Qian, Acc. Chem. Res. 49 (2016) 483-493.
[32] J. Hao and B. Yan, Adv. Funct. Mater. 27 (2017) 1603856.
[19] B. Li, H. M. Wen, Y. Cui, W. Zhou, G. Qian and B.
Cui and G. Qian, Angew. Chem., Int. Ed. 48 (2009)
[20] X. Xu and B. Yan, Adv. Funct. Mater. 27 (2017) 1700247.
500-503.
RI PT
Chen, Adv. Mater. 28 (2016) 8819-8860.
[33] B. Chen, L. Wang, Y. Xiao, F.R. Fronczek, M. Xue, Y.
[34] B. Zhao, X. Chen, P. Cheng, D. Liao, S. Yan and Z.
[21] Y. Cui, F. Zhu, B. Chen and G. Qian, Chem.
[35] H.N. Lee, H.N. Kim, K. Swamy, M.S. Park, J. Kim, H.
[22] T. Xia, T. Song, Y. Cui, Y. Yang, G. Qian, Dalton
SC
Commun. 51 (2015) 7420-7431.
Jiang, J. Am. Chem. Soc. 126 (2004) 15394-15395.
Lee, K.H. Lee, S. Park and J. Yoon, Tetrahedron Lett. 49 (2008) 1261-1265.
M AN U
Trans. 45 (2016) 18689-18695. [23] B. Zhao, X. Chen, P. Cheng, D. Liao, S. Yan and Z. Jiang, J. Am. Chem. Soc. 126 (2004) 15394-15395.
[24] Q. Tang, S. Liu, Y. Liu, J. Miao, S. Li, L. Zhang, Z. Shi and Z. Zheng, Inorg. Chem. 52 (2013) 2799-2801.
[25] W.P .Lustig, S. Mukherjee, N.D. Rudd, A.V. Desai, J.
TE D
Li and S.K. Ghosh, Chem. Soc. Rev. 46 (2017) 32423285.
[26] X. Qi, Y. Jin, N. Li, Z. Wang, K. Wang and Q. Zhang,
EP
Chem. Comm. 53 (2017) 10318-10321.
[27] H. Wang, J. Li, J.Y. Li, K. Wang, Y. Ding, and X. Xia,
AC C
NPG Asia Mater. 9 (2017) 354-354.
[28] A. Sandeep, V.K. Praveen, K.K. Kartha, V. Karunakaran and A. Ajayaghosh, Chem. Sci. 7 (2016) 4460-4467
[36] J. Xie, Y. Wang, W. Liu, X. Yin, L. Chen, Y. Zou and S. Wang, Angew. Chem. Int. Ed. 56 (2017) 75007504.
[37] D. Chen, N. Zhang, C. Liu and M. Du, J. Mater. Chem. C 5 (2017) 2311-2317.
[38] M.S. Park, K. Swamy, Y.J. Lee, H.N. Lee, Y. Jang, Y.H. Moon and J. Yoon, Tetrahedron letters 47 (2006) 8129-8132. [39] Q. Hu, J. Yu, M. Liu, A. Liu, Z. Dou and Y. Yang, J. Med. Chem. 57 (2014) 5679-5685. [40] Y. Yang, Q. Hu, Q. Zhang, K. Jiang, W. Lin, Y. Yang, Y. Cui and G. Qian, Mol. Pharmaceutics 13 (2016) 2782-2786. [41] W. Lin, Q. Hu, K. Jiang, Y. Cui, Y. Yang and G.Qian,
[29] M.Y. Jia, Y. Wang, Y. Liu, L. Niu and L. Feng, Biosens. Bioelectron. 85 (2016) 515-516.
Microporous Mesoporous Mater. 249 (2017) 5560.
[30] W. Maret and Y. Li, Chem. Rev. 109 (2009) 46824707.
12
Please do not adjust margins
ACCEPTED MANUSCRIPT
A porous and luminescent metal-organic framework containing triazine group for sensing and imaging of Zn2+
RI PT
Tianen Fan, Tifeng Xia, Qi Zhang, Yuanjing Cui*, Yu Yang, Guodong Qian*
Highlights
A porous and luminescent terbium MOF TbTATB has been designed and
SC
•
solvothermally synthesized.
TbTATB exhibited turn-on and exclusive sensing of Zn2+ with a detection limit of 10.5 nM.
•
TbTATB showed good biocompatibility and excellent imaging properties with the coexist of living cells.
TE D
The turn-on mechanism was explored by luminescent lifetime and XPS spectrum.
AC C
EP
•
M AN U
•