ORIGINAL ARTICLE
HEALTH SERVICES RESEARCH AND POLICY
A Secondary Analysis to Identify Patient-Centered Outcomes in the ACR’s Appropriateness Criteria Q 13
Matthew Thompson, MD, MPH, DPhil a , Victoria Hardy, MSc b, Monica Zigman Suchsland, MPH a, Beth Devine, PhD, PharmD, MBA c, David Kurth, MA, MPH d, Roger Chou, MD e, G. Rebecca Haines, MSM, CPXP d, Jeffrey G. Jarvik, MD, MPH f, for the PROD Research Group Abstract Context: There is a growing body of literature indicating imaging testing can affect patients cognitively, socially, behaviorally, and emotionally. The extent to which these patient-centered outcomes (PCOs) are reported in the imaging literature is unclear. Identifying PCOs may facilitate shared decision making around imaging testing. Objective: To identify PCOs across a spectrum of clinical topics included in the ACR’s Appropriateness Criteria (AC). Methods: We systematically reviewed AC evidence tables for eligible articles of studies conducted in any clinical setting in high-income countries. Included studies reported PCOs occurring as a direct or indirect result of an imaging test performed for any reason (eg, diagnosis, screening, surveillance, or staging). PCOs and the methods used to measure them were extracted through a secondary analysis and descriptive synthesis. Results: Our search identified 89 articles that reported outcomes of radiation exposure (n ¼ 37), downstream testing (n ¼ 20), complications (n ¼ 19), incidental findings (n ¼ 10), quality of life (n ¼ 7), physical discomfort (n ¼ 5), patient values and experiences (n ¼ 4), patient financial and time costs (n ¼ 4), psychosocial outcomes (n ¼ 4), and test duration (n ¼ 2). These outcomes were rarely reported from the patient perspective and were measured using a range of standardized or validated and nonstandardized methods. Conclusions: We identified few PCOs incorporated in the AC. Our findings reflect the historical emphasis of diagnostic research on accuracy, clinical utility, and selected outcomes (eg, adverse events). As radiology moves to a more patient-centered approach, it will be important to measure PCOs reported directly from patients. Keywords: Appropriateness criteria, imaging, patient-centered J Am Coll Radiol 2019;-:---. Copyright 2019 Published by Elsevier Inc. on behalf of American College of Radiology
INTRODUCTION The overriding framework that guides evaluation of diagnostic imaging tests specifies six outcomes: technical efficacy, diagnostic accuracy, diagnostic thinking, therapeutic, patient outcome, and societal efficacy [1,2].
Although there is wide agreement that efficacy studies are critical for determining how a given technology compares with existing reference or “gold standard” tests, limiting evaluation to clinical outcomes alone may be insufficient. Tests can have both direct and indirect
a Department of Family Medicine, University of Washington, Seattle, Washington. b University of Cambridge, Cambridge, England. c The Comparative Health Outcomes, Policy and Economics (CHOICE) Institute, School of Pharmacy, University of Washington, Seattle, Washington. d American College of Radiology, Reston, Virginia. e Oregon Health & Science University, Portland, Oregon. f Departments of Radiology, Neurological Surgery and Health Services, and the Comparative Effectiveness, Cost and Outcomes Research Center, University of Washington, Seattle, Washington.
Corresponding author and reprints: Matthew Thompson, MD, MPH, DPhil, Department of Family Medicine, Box 354696, University of Washington, Seattle, WA 98195-4696; e-mail:
[email protected]. Dr Jarvik is a section editor and consultant for UpToDate; has received travel reimbursement from the General Electric-Association of University of Radiologists Radiology Research Academic Fellowship (GERRAF) for service on the faculty advisory board; is a coeditor of Evidenced-Based Neuroradiology published by Springer. David Kurth and Rebecca Haines are employed by the ACR. The other authors state that they have no conflict of interest related to the material discussed in this article. Q2
ª 2019 Published by Elsevier Inc. on behalf of American College of Radiology 1546-1440/19/$36.00 n https://doi.org/10.1016/j.jacr.2019.05.016
FLA 5.6.0 DTD JACR4841_proof 4 June 2019 5:52 pm ce
1
54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106
107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158
effects on clinical management, as well as other aspects of a patient’s life, such as their emotional well-being, cognition, psychosocial impacts, and health behaviors [3-5]. These patient-centered outcomes (PCOs) could alter the overall balance between risks and benefits of a test and patients’ preferences for different tests. PCO research (PCOR) investigating diagnostic testing is in its infancy. In the context of imaging, PCOR can address outcomes and patients’ experience and deem important when selecting between imaging options. For example, patients have described claustrophobia [6], physical discomfort [6], and discovery of incidental nodules as impactful during MRI [7], and patients undergoing frequent imaging during cancer therapy have highlighted the importance of cumulative radiation exposure [8]. However, along the “test-treatment pathway” [9], diagnostic imaging tests may have many other direct and indirect effects. Collation of information on PCOs for diagnostic testing research is important in supporting the roles that radiologists and referring clinicians play in guiding patients’ decisions. Several radiologic societies have recognized the need to integrate PCOR methods into radiology research and dissemination. A consensus panel convened by the Society of Interventional Radiology ranked identifying patient-centered domains in interventional radiology procedures as the number 1 priority objective [10]. The Association of University Radiologists Radiology Research Alliance Task Force identified four PCOR priority research areas that should align with current radiology research; two priority topics include the assessment of prevention, diagnosis, and treatment options, such as screening regimens, and the communication and dissemination of research [11]. Indeed, the ACR’s Patient and Family-Centered Care initiative [12] highlights effective communication as essential for giving patients the information necessary to make informed choices [13]. To optimize decision making, it is important that providers (ie, referring clinicians and radiologists) are aware of factors related to imaging tests that may be important to patients, so they can be addressed as part of the testing process. In this study, we sought to identify the frequency and type of PCOs reported in studies of diagnostic imaging testing, by conducting a secondary analysis of studies of diagnostic imaging included in the ACR’s Appropriateness Criteria (AC). This study forms part of a program of research called Patient-Centered Research for Standards of Outcomes in Diagnostic Tests (PROD), which aims to inform methods for use of PCOs of diagnostic imaging 2
tests to facilitate more informed decision making around these tests.
METHODS Protocol Development A protocol was developed in conjunction with a Technical Expert Panel, which convened to oversee the conduct of this study. The panel consisted of individuals with expertise in radiology, systematic reviews, imaging industry representatives, members of the ACR, diagnostic methods experts, and patients and patient advocates. The design and reporting of this secondary analysis were informed by Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines [14]. Data Source The ACR systematically reviews published literature to provide evidence to inform expert and consensus-based recommendations. The AC are used by referring physicians, radiologists, and other providers to guide imaging and treatment decisions across multiple clinical areas. Within each clinical area, specific topics are identified with accompanying evidence tables that list studies identified through systematic searches. Each evidence table summarizes the study title and type, sample size, study objectives, and main findings of identified articles: https://acsearch.acr.org/list. Eligibility Criteria We included evidence tables for topics within clinical areas relevant to the PROD study, specifically topics of screening, diagnosis, surveillance and monitoring, staging imaging on adult patients (breast, cardiac, gastrointestinal, musculoskeletal, neurologic, thoracic, urologic, vascular, and women’s health). We excluded pediatrics, radiation oncology, and interventional radiology topics because these are outside the scope of the PROD study, which focused on diagnostic imaging tests in adults. Primary studies cited in eligible evidence tables were included if they reported PCOs of an imaging test used for any purpose. Included studies were conducted in any clinical setting (eg, hospital, ambulatory) in high-income countries and reported in the English language. Clinical topics were excluded if a search strategy was not available on the ACR’s website. We excluded quantitative studies of <20 patients, as well as technical feasibility studies, clinical guidelines, systematic reviews, letters, and abstracts where the full text article was not available. Studies solely reporting any of the following outcomes were also Journal of the American College of Radiology Volume - n Number - n Month 2019
FLA 5.6.0 DTD JACR4841_proof 4 June 2019 5:52 pm ce
159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210
211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262
excluded: diagnostic accuracy, incidence or prevalence, epidemiological associations, sonographic parameters, anatomic or pathologic outcomes.
Identification of PCO There is no widely accepted definition of PCOs specific to diagnostic testing. Therefore, we used PCORI’s definition, which states that PCOs encompass the following: “1) assessment of harms and benefits to inform decision making, highlighting comparisons and outcomes that matter to people; 2) a focus on outcomes that people notice and care about, and 3) the incorporation of a wide variety of settings and diversity of participants” [15]. Our definition was also influenced by Bossuyt and McCaffery’s framework, which describes the diagnostic pathways through which tests may directly influence patient outcomes [3]. We excluded outcomes that we considered downstream consequences due to changes in clinical management from the test. Due to a limited amount of extant research specifying outcomes that are important to patients for imaging tests, we did not have an exhaustive predefined list of PCOs for inclusion, meaning some PCOs were considered and discussed on a case-by-case basis. However, PCOs identified a priori based on previous research included psychosocial, quality of life, incidental findings, downstream testing, testrelated complications, and time (eg, test preparation, testing procedure, or time burden to patients), as well as physical effects of the test or testing process [3,5,16,17]. We included studies where PCOs meeting these criteria were included, regardless of whether or not they were solicited from patients themselves or were primary or secondary outcomes of the study. Search Strategy We systematically reviewed the clinical areas listed on the ACR AC website (https://acsearch.acr.org/list) to identify relevant topics within each clinical area and excluded any that were not relevant to the PROD study or lacked an accompanying search strategy. Evidence tables from eligible topics were then downloaded and hand searched for potentially eligible articles. Full details of the ACR search strategies (including search terms, search dates, selection criteria, and bibliographic databases searched) are available on the ACR website (www.acr.org/ac). We utilized evidence tables from the most recent searches performed by the ACR (range March to December 2017) and last accessed the ACR website AC to corroborate included topics on January 10, 2018. Journal of the American College of Radiology Health Services Research and Policy n Thompson et al
n
Screening The article summaries reported within each evidence table were screened for eligibility by at least two authors (M.T., V.H., M.Z.S.). Full texts of articles identified as potentially relevant were retrieved and reviewed using inclusion and exclusion criteria. Final inclusion was determined by consensus between two authors (V.H. and M.Z.S.), with discrepancies resolved by a third (M.T.). The primary reason for exclusion (ie, ineligible clinical area, design, population, outcome, not an imaging test) was recorded, and duplicate articles (ie, those appearing in more than one clinical area) were identified and removed. Data Extraction Two authors (V.H., M.Z.S.) extracted study year, design, clinical topic, imaging modality, imaging purpose, as well as details of the PCO including its definition, and measurement method from each included article to an Excel (Microsoft Corporation, Redmond, Washington, USA) spreadsheet. Extracted data were checked for accuracy (M.T.). The extracted data are presented in the Appendix. Quality Appraisal Each article had a study quality rating assessed by the ACR according to their methodology (Table 1), which is based on elements from the GRADE methodology for Q 3 appraising quality for diagnostic and therapeutic studies [18]. Because our objective was to identify PCOs rather than synthesize data to make recommendations to inform practice, we did not repeat quality appraisal. Analysis Data were analyzed through a descriptive synthesis. Identified PCOs were grouped into categories by the authors. We present our descriptive synthesis by PCO, stratified by imaging modality. RESULTS We reviewed the 254 clinical topics listed on the ACR website as of December 30, 2017. After exclusion of 92 topics not relevant to the PROD study (ie, identified by the ACR as “interventional,” “pediatric,” or “radiology oncology”), 162 topics remained. Of these, 68 had no accompanying search strategy available at the time of the review, and evidence tables for 11 topics appeared in two clinical areas. Evidence tables for the remaining 83 clinical areas were screened, another 14 of which were excluded due to no eligible articles (Fig. 1).
Patient-Centered Outcomes
FLA 5.6.0 DTD JACR4841_proof 4 June 2019 5:52 pm ce
3
Q1
263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314
315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366
Table 1. ACR summary quality criteria Study Quality Study Quality Category Category Definition Name 1
2
3
4
Criteria for Diagnostic Studies
The source has The study is all 8 well designed diagnostic and accounts quality for common elements. biases. The source has The study is 6 or 7 moderately diagnostic well designed quality and accounts elements. for most common biases. The study has The source has 3, 4, or 5 important diagnostic study design study quality limitations. elements. The source has The study or 0, 1, or 2 source is not diagnostic useful as study quality primary elements. evidence.
Criteria for Therapeutic Studies The source has 5 or 6 therapeutic study quality elements. The source has 3 or 4 therapeutic study quality elements.
The source has 1 or 2 therapeutic study quality elements. The source has 0 therapeutic study quality elements.
Our review consisted of 69 eligible clinical topics and evidence tables, which included a total of 5,196 article summaries, of which 4,815 were excluded. Of the 381 potentially eligible full-text articles reviewed, 292 were excluded because of ineligible clinical area (n ¼ 29), study design (n ¼ 57), population (n ¼ 9), or outcome (n ¼ 158); because intervention was not an imaging test (n ¼ 12); for a combination of these reasons (n ¼ 15); or because there was no full text available (n ¼ 6). A total of 89 articles were included in the descriptive synthesis (Fig. 1).
Q4
Characteristics of Included Articles The 89 included articles had sample sizes ranging from 23 to 78,353 and covered the following clinical areas: breast (n ¼ 11) [19-29], cardiac (n ¼ 19) [30-48], gastrointestinal (n ¼ 11) [49-58], musculoskeletal (n ¼ 7) [59-65], neurologic (n ¼ 4) [66-69], thoracic (n ¼ 2) [70,71], urologic (n ¼ 19) [72-90], vascular (n ¼ 112) [91-101], and women’s health (n ¼ 4) [102-105] (Table 2). Imaging modalities evaluated were: CT (n ¼ 47) [31-33,35-49,51-54,58,67,70-75,77-80,82-84, 86-88,90,91,93,94,101,103,105], MRI (n ¼ 8) 4
Fig 1. Flowchart of the publication search process that starts at ACR clinical topic, includes reasons for exclusion at each search step, and ends at final count of included articles in the review.
[34,61,69,95,97,99,100,104], mammography (n ¼ 8) [21-28], plain radiography (n ¼ 3) [55,62,63,65], ultrasound (n ¼ 1) [102], and arteriogram (n ¼ 1) [92]. A further 19 studies examined a combination of modalities [19,30,50,55-57,59,60,64,66,68,74,81,85, 89,96,98,106], and two did not report the modality or were unclear [20,107]. Imaging tests were evaluated for the primary purposes of diagnosis (n ¼ 44) [29-33, 37-44,49,55-57,59-61,65,67-69,71,81-88,90,92,93,96, 98-101,105,106], screening (n ¼ 13) [21-28,51,52,70, 102,103], treatment planning (n ¼ 5) [46-48,62,75], monitoring (n ¼ 8) [19,64,72,74,75,91,94,107], patient safety (n ¼ 4) [34,35,95,97], surveillance (n ¼ 1) [73], staging (n ¼ 3) [50,63,89], more than one purpose (n ¼ 4) [53,54,66,104], triage (n ¼ 1) [45], and seven did not report a purpose [36,58,77-80].
Quality of Included Studies The majority of studies included were graded by the ACR quality criteria (Table 1) as ‘The study has important study design limitations” (category 3) (n ¼ 34), or “The study or source is not useful as primary evidence” (category 4) (n ¼ 26) (Appendix). Journal of the American College of Radiology Volume - n Number - n Month 2019
FLA 5.6.0 DTD JACR4841_proof 4 June 2019 5:52 pm ce
367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418
419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470
Table 2. Patient-centered outcomes (PCOs) reported in included studies Imaging Modality
PCO Radiation exposure*
Downstream testing†
Q11
No. of studies
Methods and Data Sources
CT Multiple Plain radiography Total
32 4 1 37
n
CT Mammography Multiple Total
7 8 5 20
n
n
n n n n
Complications‡
Incidental or indeterminate findings§
Arteriogram CT MRI Ultrasound Multiple Total CT
1 9 4 1 4 19
n
9
n
n n
n
n n
Dosing formula Medical record or chart review
Patient report of additional tests by telephone follow-up and unspecified questionnaire Medical record review Expert report Mammography reporting system Institutional annual performance audit records for additional testing or patients recalled for additional tests Clinical observation Medical records or pathology databases Review of adverse events and reactions and documentation in material reaction forms Patient report by telephone or in-person follow-up Medical record or chart review Expert-report Population-based data registry Colonography reporting system
Multiple Total
1 10
n
Quality of lifek
MRI Multiple Total
1 6 7
n
Patient-report of generalized health status by questionnaires (SF 36, EuroQol VascuQol)
Physical discomfort¶
MRI Plain radiography CT Multiple Total CT
1 1 2 1 5 1
n
Patient-report by validated instrument (ie, visual analog scale) Patient verbal disclosure of discomfort during imaging procedure
MRI Multiple Total
2 1 4
n
MRI
1
n
Plain radiography Multiple Total
1 2 4
n
Patient values and experience#
Patient financial and time costs**
n
n
n
n
Patient report of symptom satisfaction, preferences and perceived value of selected tests Experiences of testing procedures Understanding of terminology used in test results by unspecified questionnaires Calculation of relative time expenditure on diagnostic workup to net income Patient report of days absent from work and out of pocket expenses of tests by unspecified questionnaire and telephone follow-up Administrative billing claims records (continued)
Journal of the American College of Radiology Health Services Research and Policy n Thompson et al
n
Patient-Centered Outcomes
FLA 5.6.0 DTD JACR4841_proof 4 June 2019 5:52 pm ce
5
471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522
523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574
Table 2. Continued PCO ††
Psychosocial
Imaging Modality MRI Multiple Total
No. of studies 3 1 4
Methods and Data Sources n
n
Test duration‡‡
MRI Multiple Total
1 1 2
n
Patient-report of self-efficacy, fear avoidance, depression and anxiety by validated instrument (ie, patient health questionnaire) and unspecified instruments Patient verbal disclosure (of claustrophobia) No clear reporting of methods of data capture and source
*References 29-31, 34-41, 43, 44, 52, 53, 61, 62, 65, 69, 70-72, 79-86, 88, 89, 92, 94, 99, 103, 104. † References 19-27, 38-40, 43, 47, 57, 58, 64, 68, 97, 101. ‡ References 32, 33, 35, 54, 55, 71, 75-78, 83, 87, 90, 91, 93, 95, 98, 100, 105. § References 28, 42, 44-46, 50, 51, 68, 73, 101. k References 17, 57, 58, 62, 66, 85, 96. ¶ References 56, 59, 63, 74, 91. # References 18, 49, 67, 97. **References 57, 58, 60, 67. †† References 66, 67, 97, 102. ‡‡ References 48, 59.
Characteristics of PCOs The most frequent PCOs identified were radiation exposure (n ¼ 37), downstream testing (n ¼ 20), complications (n ¼ 19), indeterminate or incidental findings (n ¼ 10). Additional PCOs identified included quality of life (n ¼ 7), physical discomfort (n ¼ 5), patient values and experiences (n ¼ 4), patient financial and time costs (n ¼ 4), psychosocial outcomes (such as depression, anxiety, self-efficacy, claustrophobia) (n ¼ 4), and test duration (n ¼ 2). Radiation exposure was most commonly reported for CT imaging (36 of 37 studies). These reported ionizing radiation risk to specified anatomical regions or the whole body (expressed as effective radiation dose) from an individual test or series of tests where multiple imaging tests were undertaken. Seven articles aggregated doses to determine cumulative radiation exposure, but only three of these noted the duration of follow-up. Radiation exposure was often estimated, rather than measured directly. Exposure estimations utilized combinations of parameters that varied by study (eg, gender, anatomic area, scanning range). Parameters were entered into, or derived from, dosing formulas facilitated by software (eg, XDose) or preset scanning protocols or formulae (eg, Monte Carlo simulations for anthropomorphic phantoms). “Downstream testing” referred to additional imaging after an initial test and was most often noted for mammography (9 of 20 studies) and CT (8 of 20). Four of the mammography studies used reporting system
6
categories (eg, BI-RADS). Seven studies of CT used medical record review to identify subsequent tests or procedures performed at the initial assessment or during follow-up, although only three articles defined the assessment or follow-up period. The need for further testing was based on expert interpretation of incidental findings identified or by the number of subsequent imaging tests conducted until a diagnosis was reached. Complications were most frequently identified for CT (13 of 19 studies) and MRI (7 of 19), and included adverse events or reactions to contrast material (eg, nephrotoxicity). In all 19 articles, these events were identified from clinical observation within a defined time frame based on changes in laboratory tests or medical record review, and three of these articles also included patient reports (eg, report of procedure discomfort). Indeterminate and incidental findings were only found in studies of CT imaging (10 of 10 studies) and referred to additional findings of varying (ie, malignant or benign) or unspecified clinical importance that indicated immediate or deferred investigations or treatment. These outcomes were determined through expert medical notes review to identify the presence and histology of indeterminate and incidental findings, or classify them using established grading conventions (eg, Colonic Reporting and Data System). PCOs reported less frequently included quality of life, physical discomfort, patient values and experiences, patient financial and time costs, psychosocial outcomes, and
Journal of the American College of Radiology Volume - n Number - n Month 2019 FLA 5.6.0 DTD JACR4841_proof 4 June 2019 5:52 pm ce
575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626
627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678
test duration. Patient-reported questionnaires were the most common tool used to capture outcomes of quality of life, emotions (eg, anxiety), patient values and experiences (eg, discomfort during imaging, patient satisfaction, or patient preference), physical discomfort, and psychosocial outcomes (eg, pain, claustrophobia, depression) at defined points after imaging. Validated questionnaires were used to solicit quality of life PCOs. Patient and financial time costs were measured using a mixture of patient report and administrative claims records and calculating the time the patient spent on the diagnostic workup relative to their net income.
DISCUSSION Main Findings Relatively few PCOs are included in studies that underpin the AC recommendations. Across the 69 clinical topics we reviewed, the PCOs identified were predominantly immediate- or short-term health complications from the test process itself (ie, adverse reactions to contrast material), or markers of potential longer-term adverse effects (ie, radiation dose). We found a much smaller body of literature reporting other outcomes, such as the frequency or impact of incidental findings, or outcomes related to emotional or behavioral effects. A small minority of the outcomes were reported from patients themselves. Overall, the quality of evidence reporting the previous outcomes were of low quality. It is perhaps not surprising that the majority of the evidence that guides AC recommendations consists of reports of accuracy or comparative accuracy. Nevertheless, many of the PCOs that we identified could be incorporated within diagnostic accuracy studies relatively easily, such as measuring adverse reactions or radiation dose. The ACR has made a particular effort to try to redress the lack of radiation assessment in the medical literature, by including this information where possible for each AC topic [108]. The paucity of data on other PCOs likely reflects lack of guidance among imaging researchers about what PCOs should be measured, their importance, lack of tools available to measure these, and inadequate reporting. Comparison With Existing Literature Leaders in the field of radiology have advocated for a shift to a more patient-centric approach to the specialty. Some have proposed models of more patient-centered radiology [109], and others have pointed out the need to identify Journal of the American College of Radiology Health Services Research and Policy n Thompson et al
n
and quantify PCOs within radiology to demonstrate the overall value of imaging [4]. Although Bossuyt and McCaffery [3] proposed the idea that tests could lead to multiple effects above and beyond impact on medical decision making, few researchers have taken this concept further by specifying which outcomes are important to patients. Nevertheless, patients who have undergone imaging identify several outcomes that they felt were important, including reassurance, anxiety, physical effects, and the knowledge gained from the test [16]. Studies of screening tests also provides examples of the psychological impacts of imaging tests, such as relief from negative tests or anxiety driven by positive (or false-positive) results [110-112]. The importance of identifying both the positive (benefits) and negative (harms) from imaging tests is that patients tend to overestimate the beneficial effects of tests compared with knowledge about their risks [113]. As Gatsonsis Q 5 et al noted, “Those planning test studies should obtain an understanding of the nature and frequency of expected patient relevant outcomes of testing” [114].
Strengths and Limitations We used the AC evidence tables as the data source for this review because they constitute a common source of evidence-based guidelines for a range of imaging tests and clinical conditions. However, it is possible that evidencebased guidelines from other organizations use different strategies to identify and incorporate PCOs to inform their guidelines, therefore our findings may not apply to all areas of testing. Two authors screened each potentially eligible article to capture any ‘hidden’ PCOs. The primary limitation of the AC evidence tables is that their focus is on test accuracy metrics, rather than a broader set of PCOs. The latter are particularly likely to be measured and reported in qualitative studies or surveys. The included studies were highly heterogeneous, prohibiting a quantitative analysis. Another limitation is that the systematic reviews used to generate the AC evidence tables were conducted at different times, did not list all the search terms used, searched only Medline, and did not list reasons for exclusion of studies. Additionally, limiting the generalizability of our study findings is the exclusion criteria such as pediatric studies and Englishonly studies. Finally, we acknowledge that there is no standard definition of PCOs for diagnostic tests, and it could be argued that some of the outcomes we examined are less patient-centric (or less directly patient-centric)
Patient-Centered Outcomes
FLA 5.6.0 DTD JACR4841_proof 4 June 2019 5:52 pm ce
7
679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730
731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782
than others. For example, the outcome of incidental findings may in reality reflect consequences or impacts of incidental findings (eg, anxiety, consequences of further testing or interventions).
-
-
Implications for Researchers, Clinicians, and Policy Makers PCOR related to diagnostic testing generally, and imaging specifically, is an emerging field of research. It is therefore not surprising that few PCOs are currently found in AC for imaging testing. Achieving PCORI’s goal of “assessing harms and benefits to inform decision making, . . . a focus on outcomes that people notice and care about” [115] will be challenging. First, we need to identify and define PCOs related to imaging testing and explore how these vary, for example, imaging modality, with reasons for testing and other patient characteristics. Initial studies are already helping to answer this gap [16]. Some outcomes are more apparent to patients (eg, emotions), whereas others may be important to patients but invisible to them (eg, radiation exposure). This will facilitate the development of instruments to measure these outcomes and incorporation into evaluations of imaging tests. Measurement of more immediate or direct outcomes of testing will be easier to achieve than longer-term or less direct outcomes. It is also unlikely that every test comparison needs to include PCOs, and it may be possible to use PCOs reported in existing test evaluations. For example, PCOs related to ultrasound scanning may be very similar across most applications of this modality, and only differ (and require more data) in particular clinical situations (eg, pregnancy-related bleeding) or test delivery (eg, transvaginal versus transabdominal scans). Exploring the extent to which PCOs are shared across imaging modalities and test situations will facilitate a rapid acquisition of information about PCOs. Finally, the ultimate goal of identifying and measuring PCOs is to improve patient care. We will need to find ways for patients to understand and use information about PCOs in collaboration with their health care providers as part of shared decision making [116]. New methods will be needed to weight various test attributes, so that the “overall evidence” for a given test is clear. TAKE-HOME POINTS -
8
The primary evidence used for current AC includes relatively few PCOs, based on a secondary analysis of 69 clinical topics.
-
We found PCOs noted in 89 of the 5,196 articles reviewed. The most common PCOs were focused on radiation exposure, downstream testing, and complications. There was very little evidence on other PCOs such as incidental findings, quality of life, physical discomfort, patient values and experiences, patient financial and time costs, psychosocial outcomes, and test duration. Measuring and using PCOs in imaging test decision making is at an early stage. Future research should define which outcomes are priorities for patients, how these can be measured, and ways to incorporate these into decision making.
ACKNOWLEDGMENTS This study was supported through a Patient Centered Outcomes Research Institute (PCORI) Program Award Q 12 (ME-1503-29245) to derive new methods to incorporate patient-centered outcomes in studies of diagnostic imaging studies (the Patient Centered Outcomes for Diagnostics, or PROD study). We appreciate the input from the PROD Stakeholder Group for input on this study. ADDITIONAL RESOURCES Additional resources can be found online at: https://doi. org/10.1016/10.1016/j.jacr.2019.05.016. REFERENCES
Q6
1. Fryback DG, Thornbury JR. The efficacy of diagnostic imaging. Med Decis Making 1991;11:88-94. 2. Fineberg HV, Bauman R, Sosman M. Computerized cranial tomography. Effect on diagnostic and therapeutic plans. JAMA 1977;238:224-7. 3. Bossuyt PM, McCaffery K. Additional patient outcomes and pathways in evaluations of testing. Med Decis Making 2009;29:E30-8. 4. Carlos RC, Buist DSM, Wernli KJ, Swan JS. Patient centered outQ7 comes in imaging: quantifying value. J Am Coll Radiol 2012;9. 5. Agapova M, Bresnahan BW, Linnau KF, et al. Toward a framework for benefit-risk assessment in diagnostic imaging. Acad Radio 24:538Q8 549. 6. Evans R, Taylor S, Janes S, et al. Patient experience and perceived acceptability of whole-body magnetic resonance imaging for staging colorectal and lung cancer compared with current staging scans: a qualitative study. BMJ Open 2017;7:e016391. 7. Wiener RS, Gould MK, Woloshin S, Schwartz LM, Clark JA. “The thing is not knowing”: patients’ perspectives on surveillance of an indeterminate pulmonary nodule. Health Expect 2015;18:355-65. 8. Thornton RH, Dauer LT, Shuk E, et al. Patient perspectives and preferences for communication of medical imaging risks in a cancer care setting. Radiology 2015;275:545-52. 9. Ferrante di Ruffano L, Hyde CJ, McCaffery KJ, Bossuyt PM, Deeks JJ. Assessing the value of diagnostic tests: a framework for designing and evaluating trials. BMJ 2012;344:e686.
Journal of the American College of Radiology Volume - n Number - n Month 2019 FLA 5.6.0 DTD JACR4841_proof 4 June 2019 5:52 pm ce
783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834
835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886
Q9
Q 10
10. Kwan SW, Charalel RA, Stover AM, et al. Development of national research and clinical agendas for patient-reported outcomes in IR: proceedings from a multidisciplinary consensus panel. J Vasc Interv Radiol 2018;29:1-8. 11. Zygmont ME, Lam DL, Nowitzki KM, et al. Opportunities for patient-centered outcomes research in radiology. Acad Radiol 2016;23:8-17. 12. American College of Radiology. Physician Resources for Patient- & Family-Centered Care Available at: https://www.acr.org/PracticeManagement-Quality-Informatics/Patient-Family-Centered-Care. 13. Hudson SPLCJ. Interconnected: an exploration of improvement efforts connecting patient experience and communication Available at: https://shop.acr.org/images/PFCCToolKit/201841793646946_ Communication%20White%20Paper.pdf. 14. Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ 2009;339:b2535. 15. Gazelle GS, Kessler L, Lee DW, et al. A framework for assessing the value of diagnostic imaging in the era of comparative effectiveness research. Radiology 2011;261:692-8. 16. Zigman Suchsland ML, Witwer E, Truitt AR, et al. Patient-centered outcomes related to imaging testing in US primary care. J Am Coll Radiol 2018. 17. Harris RP, Sheridan SL, Lewis CL, et al. The harms of screening: a proposed taxonomy and application to lung cancer screening. JAMA Intern Med 2014;174:281-5. 18. American College of Radiologists. ACR Appropriateness Criteria. Evidence Table Development. Available at: https://www.acr.org/-/media/ ACR/Files/Appropriateness-Criteria/EvidenceTableDevelopment.pdf. 19. Impact of follow-up testing on survival and health-related quality of life in breast cancer patients. A multicenter randomized controlled trial. The GIVIO Investigators. JAMA 1994;271:1587-92. 20. Muss HB, Tell GS, Case LD, Robertson P, Atwell BM. Perceptions of follow-up care in women with breast cancer. Am J Clin Oncol 1991;14:55-9. 21. Lourenco AP, Barry-Brooks M, Baird GL, Tuttle A, Mainiero MB. Changes in recall type and patient treatment following implementation of screening digital breast tomosynthesis. Radiology 2015;274: 337-42. 22. Durand MA, Haas BM, Yao X, et al. Early clinical experience with digital breast tomosynthesis for screening mammography. Radiology 2015;274:85-92. 23. Rose SL, Tidwell AL, Bujnoch LJ, Kushwaha AC, Nordmann AS, Sexton R Jr. Implementation of breast tomosynthesis in a routine screening practice: an observational study. AJR Am J Roentgenol 2013;200:1401-8. 24. Friedewald SM, Rafferty EA, Rose SL, et al. Breast cancer screening using tomosynthesis in combination with digital mammography. JAMA 2014;311:2499-507. 25. Greenberg JS, Javitt MC, Katzen J, Michael S, Holland AE. Clinical performance metrics of 3D digital breast tomosynthesis compared with 2D digital mammography for breast cancer screening in community practice. AJR Am J Roentgenol 2014;203:687-93. 26. McCarthy AM, Kontos D, Synnestvedt M, et al. Screening outcomes following implementation of digital breast tomosynthesis in a generalpopulation screening program. J Natl Cancer Inst 2014;106. 27. Rafferty EA, Park JM, Philpotts LE, et al. Diagnostic accuracy and recall rates for digital mammography and digital mammography combined with one-view and two-view tomosynthesis: results of an enriched reader study. AJR Am J Roentgenol 2014;202:273-81. 28. Haas BM, Kalra V, Geisel J, Raghu M, Durand M, Philpotts LE. Comparison of tomosynthesis plus digital mammography and digital mammography alone for breast cancer screening. Radiology 2013;269:694-700. 29. Howard MB, Battaglia T, Prout M, Freund K. The effect of imaging on the clinical management of breast pain. J Gen Intern Med 2012;27:817-24.
Journal of the American College of Radiology Health Services Research and Policy n Thompson et al
n
30. Revel MP, Cohen S, Sanchez O, et al. Pulmonary embolism during pregnancy: diagnosis with lung scintigraphy or CT angiography? Radiology 2011;258:590-8. 31. Achenbach S, Marwan M, Ropers D, et al. Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J 2010;31:340-6. 32. Leipsic J, Labounty TM, Heilbron B, et al. Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study. AJR Am J Roentgenol 2010;195:655-60. 33. Husmann L, Valenta I, Gaemperli O, et al. Feasibility of low-dose coronary CT angiography: first experience with prospective ECGgating. Eur Heart J 2008;29:191-7. 34. Dillman JR, Ellis JH, Cohan RH, Strouse PJ, Jan SC. Frequency and severity of acute allergic-like reactions to gadolinium-containing i.v. contrast media in children and adults. AJR Am J Roentgenol 2007;189:1533-8. 35. Nguyen SA, Suranyi P, Ravenel JG, et al. Iso-osmolality versus low-osmolality iodinated contrast medium at intravenous contrastenhanced CT: effect on kidney function. Radiology 2008;248:97105. 36. Earls JP, Berman EL, Urban BA, et al. Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 2008;246:742-53. 37. Douglas PS, Hoffmann U, Patel MR, et al. Outcomes of anatomical versus functional testing for coronary artery disease. N Engl J Med 2015;372:1291-300. 38. Stolzmann P, Leschka S, Scheffel H, et al. Dual-source CT in stepand-shoot mode: noninvasive coronary angiography with low radiation dose. Radiology 2008;249:71-80. 39. Han BK, Hlavacek AM, Kay WA, et al. Multi-institutional evaluation of the indications and radiation dose of functional cardiovascular computed tomography (CCT) imaging in congenital heart disease. Int J Cardiovasc Imaging 2016;32:339-46. 40. Madder RD, Raff GL, Hickman L, et al. Comparative diagnostic yield and 3-month outcomes of “triple rule-out” and standard protocol coronary CT angiography in the evaluation of acute chest pain. J Cardiovasc Comput Tomogr 2011;5:165-71. 41. Poon M, Cortegiano M, Abramowicz AJ, et al. Associations between routine coronary computed tomographic angiography and reduced unnecessary hospital admissions, length of stay, recidivism rates, and invasive coronary angiography in the emergency department triage of chest pain. J Am Coll Cardiol 2013;62:543-52. 42. Hoffmann U, Truong QA, Schoenfeld DA, et al. Coronary CT angiography versus standard evaluation in acute chest pain. N Engl J Med 2012;367:299-308. 43. Hamilton-Craig C, Fifoot A, Hansen M, et al. Diagnostic performance and cost of CT angiography versus stress ECG—a randomized prospective study of suspected acute coronary syndrome chest pain in the emergency department (CT-COMPARE). Int J Cardiol 2014;177:867-73. 44. Lehman SJ, Abbara S, Cury RC, et al. Significance of cardiac computed tomography incidental findings in acute chest pain. Am J Med 2009;122:543-9. 45. Cury RC, Feuchtner GM, Batlle JC, et al. Triage of patients presenting with chest pain to the emergency department: implementation of coronary CT angiography in a large urban health care system. AJR Am J Roentgenol 2013;200:57-65. 46. Rogers IS, Banerji D, Siegel EL, et al. Usefulness of comprehensive cardiothoracic computed tomography in the evaluation of acute undifferentiated chest discomfort in the emergency department (CAPTURE). Am J Cardiol 2011;107:643-50. 47. Ben-Dor I, Waksman R, Hanna NN, et al. Utility of radiologic review for noncardiac findings on multislice computed tomography in
Patient-Centered Outcomes
FLA 5.6.0 DTD JACR4841_proof 4 June 2019 5:52 pm ce
9
887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938
939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990
48.
49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
10
patients with severe aortic stenosis evaluated for transcatheter aortic valve implantation. Am J Cardiol 2010;105:1461-4. Apfaltrer P, Schymik G, Reimer P, et al. Aortoiliac CT angiography for planning transcutaneous aortic valve implantation: aortic root anatomy and frequency of clinically significant incidental findings. AJR Am J Roentgenol 2012;198:939-45. Dixon AK, Fry IK, Kingham JG, McLean AM, White FE. Computed tomography in patients with an abdominal mass: effective and efficient? A controlled trial. Lancet 1981;1:1199-201. Kinner S, Antoch G, Bockisch A, Veit-Haibach P. Whole-body PET/ CT-colonography: a possible new concept for colorectal cancer staging. Abdom Imaging 2007;32:606-12. Moawad FJ, Maydonovitch CL, Cullen PA, Barlow DS, Jenson DW, Cash BD. CT colonography may improve colorectal cancer screening compliance. AJR Am J Roentgenol 2010;195:1118-23. Kim DH, Pickhardt PJ, Hanson ME, Hinshaw JL. CT colonography: performance and program outcome measures in an older screening population. Radiology 2010;254:493-500. Schwartz LH, Gandras EJ, Colangelo SM, Ercolani MC, Panicek DM. Prevalence and importance of small hepatic lesions found at CT in patients with cancer. Radiology 1999;210:71-4. Desmond AN, O’Regan K, Curran C, et al. Crohn’s disease: factors associated with exposure to high levels of diagnostic radiation. Gut 2008;57:1524-9. Levi Z, Fraser E, Krongrad R, et al. Factors associated with radiation exposure in patients with inflammatory bowel disease. Aliment Pharmacol Ther 2009;30:1128-36. Hammerstingl R, Huppertz A, Breuer J, et al. Diagnostic efficacy of gadoxetic acid (Primovist)-enhanced MRI and spiral CT for a therapeutic strategy: comparison with intraoperative and histopathologic findings in focal liver lesions. Eur Radiol 2008;18:457-67. Ichikawa T, Saito K, Yoshioka N, et al. Detection and characterization of focal liver lesions: a Japanese phase III, multicenter comparison between gadoxetic acid disodium-enhanced magnetic resonance imaging and contrast-enhanced computed tomography predominantly in patients with hepatocellular carcinoma and chronic liver disease. Invest Radiol 2010;45:133-41. Pollentine A, Mortimer A, McCoubrie P, Archer L. Evaluation of two minimal-preparation regimes for CT colonography: optimising image quality and patient acceptability. Br J Radiol 2012;85: 1085-92. Nikken JJ, Oei EH, Ginai AZ, et al. Acute peripheral joint injury: cost and effectiveness of low-field-strength MR imaging—results of randomized controlled trial. Radiology 2005;236:958-67. Oei EH, Nikken JJ, Ginai AZ, K, et al. Costs and effectiveness of a brief MRI examination of patients with acute knee injury. Eur Radiol 2009;19:409-18. Tagliafico A, Podesta A, Assini A, et al. MR Imaging of total hip arthroplasty: comparison among sequences to study the sciatic nerve at 1.5 T. Magn Reson Imaging 2010;28:1319-26. Glaser D, Lotke P. Cost-effectiveness of immediate postoperative radiographs after uncomplicated total knee arthroplasty: a retrospective and prospective study of 750 patients. J Arthroplasty 2000;15: 475-8. Kanekasu K, Kondo M, Kadoya Y. Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 2005:193-7. Lee AI, Zuckerman DS, Van den Abbeele AD, et al. Surveillance imaging of Hodgkin lymphoma patients in first remission: a clinical and economic analysis. Cancer 2010;116:3835-42. Schock HJ, Pinzur M, Manion L, Stover M. The use of gravity or manual-stress radiographs in the assessment of supination-external rotation fractures of the ankle. J Bone Joint Surg Br 2007;89: 1055-9. Fiser SM, Johnson SB, Fortune JB. Resource utilization in traumatic brain injury: the role of magnetic resonance imaging. Am Surg 1998;64:1088-93.
67. Al Abduwani J, ZilinSkiene L, Colley S, Ahmed S. Cone beam CT paranasal sinuses versus standard multidetector and low dose multidetector CT studies. Am J Otolaryngol 2016;37:59-64. 68. Jarvik JG, Gold LS, Comstock BA, et al. Association of early imaging for back pain with clinical outcomes in older adults. JAMA 2015;313: 1143-53. 69. Modic MT, Obuchowski NA, Ross JS, et al. Acute low back pain and radiculopathy: MR imaging findings and their prognostic role and effect on outcome. Radiology 2005;237:597-604. 70. Vierikko T, Jarvenpaa R, Autti T, et al. Chest CT screening of asbestos-exposed workers: lung lesions and incidental findings. Eur Respir J 2007;29:78-84. 71. Schertler T, Glucker T, Wildermuth S, Jungius KP, Marincek B, Boehm T. Comparison of retrospectively ECG-gated and nongated MDCT of the chest in an emergency setting regarding workflow, image quality, and diagnostic certainty. Emerg Radiol 2005;12:19-29. 72. Silva MV, Motamedinia P, Badalato GM, Hruby G, McKiernan JM. Diagnostic radiation exposure risk in a contemporary cohort of male patients with germ cell tumor. J Urol 2012;187:482-6. 73. van Walraven C, Fergusson D, Earle C, et al. Association of diagnostic radiation exposure and second abdominal-pelvic malignancies after testicular cancer. J Clin Oncol 2011;29:2883-8. 74. O’Malley ME, Chung P, Haider M, et al. Comparison of low dose with standard dose abdominal/pelvic multidetector CT in patients with stage 1 testicular cancer under surveillance. Eur Radiol 2010;20: 1624-30. 75. Hoppe H, Studer R, Kessler TM, Vock P, Studer UE, Thoeny HC. Alternate or additional findings to stone disease on unenhanced computerized tomography for acute flank pain can impact management. J Urol 2006;175:1725-30; discussion 30. 76. Willmann JK, Wildermuth S, Pfammatter T, et al. Aortoiliac and renal arteries: prospective intraindividual comparison of contrastenhanced three-dimensional MR angiography and multi-detector row CT angiography. Radiology 2003;226:798-811. 77. Davenport MS, Khalatbari S, Dillman JR, Cohan RH, Caoili EM, Ellis JH. Contrast material-induced nephrotoxicity and intravenous low-osmolality iodinated contrast material. Radiology 2013;267:94105. 78. Davenport MS, Khalatbari S, Cohan RH, Dillman JR, Myles JD, Ellis JH. Contrast material-induced nephrotoxicity and intravenous low-osmolality iodinated contrast material: risk stratification by using estimated glomerular filtration rate. Radiology 2013;268: 719-28. 79. McDonald RJ, McDonald JS, Bida JP, et al. Intravenous contrast material-induced nephropathy: causal or coincident phenomenon? Radiology 2013;267:106-18. 80. McDonald JS, McDonald RJ, Carter RE, Katzberg RW, Kallmes DF, Williamson EE. Risk of intravenous contrast material-mediated acute kidney injury: a propensity score-matched study stratified by baselineestimated glomerular filtration rate. Radiology 2014;271:65-73. 81. Liu W, Esler SJ, Kenny BJ, Goh RH, Rainbow AJ, Stevenson GW. Low-dose nonenhanced helical CT of renal colic: assessment of ureteric stone detection and measurement of effective dose equivalent. Radiology 2000;215:51-4. 82. Meagher T, Sukumar VP, Collingwood J, et al. Low dose computed tomography in suspected acute renal colic. Clin Radiol 2001;56:8736. 83. Tack D, Sourtzis S, Delpierre I, de Maertelaer V, Gevenois PA. Lowdose unenhanced multidetector CT of patients with suspected renal colic. AJR Am J Roentgenol 2003;180:305-11. 84. Poletti PA, Platon A, Rutschmann OT, Schmidlin FR, Iselin CE, Becker CD. Low-dose versus standard-dose CT protocol in patients with clinically suspected renal colic. AJR Am J Roentgenol 2007;188: 927-33. 85. Smith-Bindman R, Aubin C, Bailitz J, et al. Ultrasonography versus computed tomography for suspected nephrolithiasis. N Engl J Med 2014;371:1100-10.
Journal of the American College of Radiology Volume - n Number - n Month 2019 FLA 5.6.0 DTD JACR4841_proof 4 June 2019 5:52 pm ce
991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042
1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094
86. Eiber M, Holzapfel K, Frimberger M, et al. Targeted dual-energy single-source CT for characterisation of urinary calculi: experimental and clinical experience. Eur Radiol 2012;22:251-8. 87. Katz SI, Saluja S, Brink JA, Forman HP. Radiation dose associated with unenhanced CT for suspected renal colic: impact of repetitive studies. AJR Am J Roentgenol 2006;186:1120-4. 88. Mulkens TH, Daineffe S, De Wijngaert R, et al. Urinary stone disease: comparison of standard-dose and low-dose with 4D MDCT tube current modulation. AJR Am J Roentgenol 2007;188:553-62. 89. Bach-Gansmo T, Nanni C, Nieh PT, et al. Multisite experience of the safety, detection rate and diagnostic performance of fluciclovine ((18) F) positron emission tomography/computerized tomography imaging in the staging of biochemically recurrent prostate cancer. J Urol 2017;197(3 Pt 1):676-83. 90. Toepker M, Kuehas F, Kienzl D, et al. Dual energy computerized tomography with a split bolus-a 1-stop shop for patients with suspected urinary stones? J Urol 2014;191:792-7. 91. Macari M, Chandarana H, Schmidt B, Lee J, Lamparello P, Babb J. Abdominal aortic aneurysm: can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose? Radiology 2006;241:908-14. 92. Egglin TKP, O’Moore PV, Feinstein AR, Waltman AC. Complications of peripheral arteriography: a new system to identify patients at increased risk. J Vasc Surg 1995;22:787-94. 93. Nonent M, Thouveny F, Simons P, et al. Iodixanol in multidetectorrow computed tomography angiography (MDCTA): diagnostic accuracy for abdominal aorta and abdominal aortic major-branch diseases using four-, eight- and 16-detector-row CT scanners. Acta Radiol 2007;48:48-58. 94. Pinho DF, Kulkarni NM, Krishnaraj A, Kalva SP, Sahani DV. Initial experience with single-source dual-energy CT abdominal angiography and comparison with single-energy CT angiography: image quality, enhancement, diagnosis and radiation dose. Eur Radiol 2013;23:351-9. 95. Collidge TA, Thomson PC, Mark PB, et al. Gadolinium-enhanced MR imaging and nephrogenic systemic fibrosis: retrospective study of a renal replacement therapy cohort. Radiology 2007;245:168-75. 96. Cina A, Barone-Adesi L, Rinaldi P, et al. Planning deep inferior epigastric perforator flaps for breast reconstruction: a comparison between multidetector computed tomography and magnetic resonance angiography. Eur Radiol 2013;23:2333-43. 97. Wang Y, Alkasab TK, Narin O, et al. Incidence of nephrogenic systemic fibrosis after adoption of restrictive gadolinium-based contrast agent guidelines. Radiology 2011;260:105-11. 98. Ouwendijk R, de Vries M, Stijnen T, et al. Multicenter randomized controlled trial of the costs and effects of noninvasive diagnostic imaging in patients with peripheral arterial disease: the DIPAD trial. AJR Am J Roentgenol 2008;190:1349-57. 99. Vahl AC, Geselschap J, Montauban van Swijndregt AD, et al. Contrast enhanced magnetic resonance angiography versus intraarterial digital subtraction angiography for treatment planning in patients with peripheral arterial disease: a randomised controlled diagnostic trial. Eur J Vasc Endovasc Surg 2008;35:514-21; discussion 22-3.
Journal of the American College of Radiology Health Services Research and Policy n Thompson et al
n
100. Rapp JH, Wolff SD, Quinn SF, et al. Aortoiliac occlusive disease in patients with known or suspected peripheral vascular disease: safety and efficacy of gadofosveset-enhanced MR angiography—multicenter comparative phase III study. Radiology 2005;236:71-8. 101. Utsunomiya D, Oda S, Funama Y, et al. Comparison of standard- and low-tube voltage MDCT angiography in patients with peripheral arterial disease. Eur Radiol 2010;20:2758-65. 102. Buys SS, Partridge E, Black A, et al. Effect of screening on ovarian cancer mortality: the Prostate, Lung, Colorectal and Ovarian (PLCO) cancer screening randomized controlled trial. JAMA 2011;305:2295303. 103. Pickhardt PJ, Hanson ME. Incidental adnexal masses detected at lowdose unenhanced CT in asymptomatic women age 50 and older: implications for clinical management and ovarian cancer screening. Radiology 2010;257:144-50. 104. Spencer JA, Chahal R, Kelly A, Taylor K, Eardley I, Lloyd SN. Evaluation of painful hydronephrosis in pregnancy: magnetic resonance urographic patterns in physiological dilatation versus calculous obstruction. J Urol 2004;171:256-60. 105. Jepperson MA, Cernigliaro JG, Ibrahim el SH, Morin RL, Haley WE, Thiel DD. In vivo comparison of radiation exposure of dual-energy CT versus low-dose CT versus standard CT for imaging urinary calculi. J Endourol 2015;29:141-6. 106. Raman SS, Leary C, Bluemke DA, et al. Improved characterization of focal liver lesions with liver-specific gadoxetic acid disodium-enhanced magnetic resonance imaging: a multicenter phase 3 clinical trial. J Comput Assist Tomogr 2010;34:163-72. 107. Davies AR. Commentary on improving customer satisfaction. Manag Care Q 1995;3:46-7. 108. American College of Radiologists. ACR Appropriateness Criteria. Radiation Dose Assessment Introduction. Available at: https://www.acr.org/-/ media/ACR/Files/Appropriateness-Criteria/RadiationDoseAssessmentInt ro.pdf. 109. Swan JS, Furtado VF, Keller LA, et al. Pilot study of a patientcentered radiology process model. J Am Coll Radiol 2017;14:274-81. 110. Brewer NT, Salz T, Lillie SE. Systematic review: the long-term effects of false-positive mammograms. Ann Intern Med 2007;146:502-10. 111. Metsala E, Pajukari A, Aro AR. Breast cancer worry in further examination of mammography screening—a systematic review. Scand J Caring Sci 2012;26:773-86. 112. Brain K, Lifford KJ, Carter B, et al. Long-term psychosocial outcomes of low-dose CT screening: results of the UK Lung Cancer Screening randomised controlled trial. Thorax 2016;71:996-1005. 113. Hoffmann TC, Del Mar C. Clinicians’ expectations of the benefits and harms of treatments, screening, and tests: a systematic review. JAMA Intern Med 2017;177:407-19. 114. Gatsonis C. Design of evaluations of imaging technologies: development of a paradigm. Acad Radiol 2000;7:681-3. 115. Patient-Centered Outcomes Research Institute (PCORI). The PCORI Methodology Report. Available at: https://www.pcori.org/ research-results/about-our-research/research-methodology/pcori-meth odology-report. 116. Wiener RS, Slatore CG, Gillespie C, Clark JA. Pulmonologists’ reported use of guidelines and shared decision-making in evaluation of pulmonary nodules: a qualitative study. Chest 2015;148:1415-21.
Patient-Centered Outcomes
FLA 5.6.0 DTD JACR4841_proof 4 June 2019 5:52 pm ce
11
1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146