Cardiac working conditions can be optimized by synchronized pulsatile extracorporeal life support

Cardiac working conditions can be optimized by synchronized pulsatile extracorporeal life support

October 2004, Vol 126, No. 4_MeetingAbstracts Abstract: Poster Presentations | October 2004 Cardiac working conditions can be optimized by synchroniz...

230KB Sizes 0 Downloads 18 Views

October 2004, Vol 126, No. 4_MeetingAbstracts Abstract: Poster Presentations | October 2004

Cardiac working conditions can be optimized by synchronized pulsatile extracorporeal life support Koen Reesink, MS; Loes Sauren, BS*; Andre Dekker, PhD; Theo van der Nagel; Ervin Severdija; Cecile Soemers, MD; Gijs Geskes, MD; Erik van der Veen, PhD; Jos Maessen, MD, PhD Cardiovascular Research Institute Maastricht, Maastricht, the Netherlands Chest Chest. 2004;126(4_MeetingAbstracts):855S. doi:10.1378/chest.126.4_MeetingAbstracts.855S

Abstract PURPOSE: To investigate the potential of synchronization of pulsatile extracorporeal life support (p-ECLS). METHODS: Five calves (60±21 kg) were instrumented and subjected to partial femoro-femoral veno-arterial ECMO. Heart rate was synchronized to pump-ejection by a custom made pacemaker system. The cardiac-to-pump ejection delay was varied in 50 ms steps along the cardiac cycle. Data analysis focused on cardiac workload and peripheral perfusion. RESULTS: Based on LV afterload (PLVpeak) three markers were identified in each animal: Maximum increase (I), mean (II), and maximum decrease (III) of afterload (see Figure 1and 2). The Table shows that systolic arrival of the p-ECLS pulse increased LV afterload (I). Elevated LV afterload is associated with an increase in PVA (oxygen consumption) and a decreased ventricular efficiency (EW/PVA). The diastolic coronary flow fraction during diastolic arrival (III) is about twice as high as during systolic arrival. Among the subjects the fraction of total peripheral flow delivered by the LV varied substantially (Table). Figure 1 and 2 show the delay dependency of multiple hemodynamic variables in two distinct cases of LV contribution. The balance between peripheral (and coronary) perfusion and cardiac workload can be improved by avoiding systolic pulse arrival (Figure 1 and 2). CONCLUSION: During partial pulsatile ECLS ventricular efficiency can be improved upto 30 percent by avoidance of systolic impairment. Synchronization is more effective in subjects with a small left ventricular contribution to total peripheral flow. CLINICAL IMPLICATIONS: Well-adjusted pulsatile extracorporeal life support may be more versatile than asynchronous or continuous systems in facilitating recovery of cardiac function. DISCLOSURE: L. Sauren, None. Wednesday, October 27, 2004 12:30 PM- 2:00 PM