Journal Pre-proof Coumarin-based colorimetric-fluorescent sensors for the sequential detection of Zn2+ ion and phosphate anions and applications in cell imaging
Jiaxin Fu, Kun Yao, Bai Li, Huihui Mei, Yongxin Chang, Kuoxi Xu PII:
S1386-1425(19)31180-1
DOI:
https://doi.org/10.1016/j.saa.2019.117790
Reference:
SAA 117790
To appear in:
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Received date:
16 August 2019
Revised date:
6 November 2019
Accepted date:
11 November 2019
Please cite this article as: J. Fu, K. Yao, B. Li, et al., Coumarin-based colorimetricfluorescent sensors for the sequential detection of Zn2+ ion and phosphate anions and applications in cell imaging, Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy(2019), https://doi.org/10.1016/j.saa.2019.117790
This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
© 2019 Published by Elsevier.
Journal Pre-proof Coumarin-based colorimetric-fluorescent sensors for the sequential detection of Zn2+ ion and phosphate anions and applications in cell imaging Jiaxin Fu, KunYao, Bai Li, Huihui Mei, Yongxin Chang, Kuoxi Xu College of Chemistry and Chemical Engineering, Henan University, Kaifeng 475004, Henan, China
re
-p
ro
of
Abstract: Two novel coumarin based fluorescent sensors CHP and CHS have been synthesized for the sequential detection of Zn2+ ion and phosphate anion (PA) in DMF/HEPES buffer medium (1/5 v/v, 10 mM, pH=7.4). On the addition of Zn2+ ion to the solution of CHP or CHS resulted in a pronounced fluorescence enhancement, accompanying noticeable color change (under UV or daylight), while there was hardly obvious change with other competing metal ions co-existing. The detection limits (DL) of CHP and CHS towards Zn2+ were separately determined as 1.03×10−7 (R2 = 0.9886) and 1.87×10−7 (R2 = 0.9902). The PET binding processes were affirmed by spectroscopic techniques, HRMS experiments and theoretical calculations. Subsequently, the CHP-Zn2+ or CHS-Zn2+ complexes showed high selectivity fluorescence quenching toward PA by snatching Zn2+ ion from its complex and the binding processes were reversible. DLs were calculated as 2.07×10−7 M (R2 = 0.9928) and 2.63×10−7 M (R2 = 0.9954), respectively. Furthermore, the cell imaging experiments demonstrated that the sensors were capable of detecting of Zn2+ and PA in vitro cells.
na
1. Introduction
lP
Keywords: fluorescent sensor; coumarin; Zn2+; phosphate anion; cell imaging
As we all know that appropriate levels of metal ions and anions play an
Jo ur
indispensable role in the tissue structures and physiological responses in living organisms [1-3]. The development of detecting various metal ions and anions in environment and biological system has rapidly increased in chemical and biological technology [4, 5]. Some standard instrumental techniques like ion chromatography (IC) [6], atomic absorption spectrometry (AAS) [7], inductively coupled plasma mass spectrometry (IPC-MS) [8] and liquid chromatography [9] are expensive and not suitable for many applications. It becomes important to find alternative ways for the analyte determination. The fluorescence spectroscopy is an alternative method due to its advantages, such as low cost, simple operation, high selectivity and selectivity, real-time detection [10-14]. Hence, it is significant to design fluorescence sensors for detecting analyte, especially “naked eye” detection sensors.
Corresponding author. Tel.:/Fax: +86 37123881589. E-mail addresses:
[email protected]. 1
Journal Pre-proof Zinc (Zn2+) is one of the essential trace metals in living creatures [15]. Appropriate content of zinc plays an indispensable role in the organization and physiological response of organisms [16-19]. Excessive intake of Zn2+ in the human body can lead to prostate cancer, Alzheimer's disease, and neurological diseases [20, 21]. But the lack of Zn2+ in the human body can lead to cognitive impairment, immune dysfunction, diarrhea and death, especially for children under 5 years of age [22-24]. On the other hand, phosphate anions maintain the stability of the body's environment and the normal functioning of cellular functions in the human body, including cell
of
metabolism and energy transfer [25, 26]. Excessive or insufficient phosphate in body
ro
fluids can cause diseases such as muscle weakness, impaired white blood cell function, rickets, rickets, etc. [27-30]. According to the strong covalent interaction of the
-p
targeted anions with metal ions, we can select the appropriate metal complexes to
re
detect the anions indirectly. It is a strategy to detect anions [31]. Zn2+ complex is a common sensor for phosphate anions, mainly because phosphate is a reversible
lP
inhibitor of Zn2+ in prostate tissue [32].
na
In present study, two sensors based coumarin were synthesized simply, which contained -C=N- to enhance the ability of binding metal ions and the system of
Jo ur
conjugation. As a result, free sensor displayed weak fluorescence due to -C=Nisomerization, while specific metal ions combined, isomerization process was crippled so that fluorescence released. The literatures [33-39] towards Zn2+ recently published were taken to compare with this study (Table 1.), which started with media, association constant (Ka), detection limit (DL) and applications. Firstly, monitoring the guest in pure aqueous solution has always been the goal of the researchers, and some media still remain in the pure organic solvent phase, and we have chosen other less toxic aqueous media. Moreover, Ka and DL have been reached the upper middle level. Finally, our sensors were applied by more methods to prove their practical abilities.
2
Journal Pre-proof Table 1. Comparison of the properties of CHP and CHS with recently reported Zn2+ sensors Entr y
Probe
Media
DMSO-
1
HEPES
2
MeOH
Ka
DL (M)
Application
Reference
/
6.9×10-7
Cell imaging
33
2.0×105
2.4×10-6
/
34
(M-1)
Anion
HEPES
3.97×10
of
3
recognition; 5
5.6×10
-8
Detection
of
35
DNA
ro
MeOH-
HEPES
DMF-
5
HEPES
na
6
buffer
Jo ur
7
1.47×10-5
lP
H2O
1.68×105
8
DMSO
2.1×10-8
re
MeOH-
4
-p
Amplification
3.9×104
1.1×10-7
6.2×10-8
Cell imaging
On-Site Analysis
Cell imaging
36
37
38
Anion 1.39×10
5
-7
1.40×10
recognition;
39
Cell imaging 3.33×104
1.03×10-7
DMF-
Logic function; On-site analysis Anion
HEPES 8.11×103
1.87×10-7
This work
recognition; Cell imaging
2. Experimental 2.1 Materials and instrumentations The chemicals used in the experiment are all marketed products (analytical grade) without secondary purification. 1H NMR and
13
C NMR data were recorded on a
Bruker AV-400 MHz NMR spectrometer using DMSO-d6 solvent. FT-IR spectroscopy 3
Journal Pre-proof was performed using a Nicolet 670 FT-IR infrared spectrophotometer using KBr pelleting. Mass spectrometry data was recorded by a Thermo Scientific LTQ Orbitrap XL mass spectrometer. Fluorescence spectra and UV absorption spectra were determined by F-7000FL fluorescence spectrophotometer and Hitachi U1900 UV spectrophotometer, respectively. Melting point was determinated by MEL-TEMP melting point apparatus. The intermediate 7-hydroxycoumarin hydrazone was synthesized according to the literatures [40].
of
2.2 Synthesis of sensor CHP and CHS The synthesis of sensors CHP and CHS are depicted in Scheme 1. Compound
ro
7-hydroxycoumarin hydrazine (1.02 g, 5 mmol) was dissolved in 20 mL of ethanol
-p
and heated to reflux. Then a solution of 2-pyridinecarboxaldehyde (0.80 g, 7.5 mmol) dissolved in 10 mL of ethanol was gradually dropped into the flask. Stir at 65 °C for
re
10 h under the protection of nitrogen until a pale yellow solid precipitated. Then the
lP
sediment was filtered and washed with ethanol to give 1.12 g of CHP (Yield: 76 %, m.p. 263.56-264.23 ℃), 1H NMR δ 12.44 (s, 1H), 9.28 (s, 1H), 8.87 (s, 1H), 8.75 (d,
na
J=4 Hz, 2H), 8.20 (d, J = 12Hz, 1H), 8.06 (d, J = 16 Hz, 1H), 7.97 (t, J = 16 Hz, 1H), 7.81 (d, J = 8.0 Hz, 1H), 7.56 (t, J = 20 Hz, 1H), 7.04 (d, J = 12 Hz, 1H), 6.40 (d, 13
C NMR δ 164.10, 162.84, 159.72, 154.76, 152.44, 150.55,
Jo ur
J=12Hz, 1H) (Fig. S1);
145.09, 137.61, 133.86, 126.40, 122.43, 114.26, 112.82, 111.73, 105.59 (Fig. S2); IR (KBr): 3430, 2426, 1724, 1612, 1235, 1117, 992, 780 cm−1 (Fig. S3); HRMS: calcd for: [CHP+H+]: 294.0873; Found: 294.0878 (Fig. S4). The same way to get 1.05 g of CHS as a yellow solid, Yield: 68%, m.p. 246.35-247.36 ℃, 1H NMR δ 12.57 (s, 1H), 10.90 (s, 1H), 9.31 (s, 1H), 9.10 (s, 1H), 8.05 (d, J = 12 Hz, 1H), 7.77 (t, J = 20 Hz, 2H), 7.44 (t, J = 20 Hz, 1H), 7.00 (q, J = 28 Hz, 3H), 6.38 (d, J = 12 Hz, 1H) (Fig. S5);
13
C NMR δ 163.78, 162.76, 159.73,
158.42, 154.59, 145.10, 134.16, 133.49, 130.95, 120.12, 118.63, 117.12, 114.21, 112.77, 111.73 (Fig. S6); IR (KBr): 3448, 3085, 1738, 1618, 1483, 1235, 1108, 991, 752, 447 cm−1 (Fig. S7); HRMS: calcd for: [CHS+H+]: 309.0870; Found: 309.0872 (Fig. S8). 4
Journal Pre-proof
Scheme 1. Synthesis of compound CHP and CHS.
2.3 Spectroscopic study Compound CHP or CHS were formulated into a 0.1 M solution in DMF. Then it
of
was diluted to 3.33×10−5 with a mixed solution of HEPES buffer solution (pH=7.4)
ro
and DMF solution (1:5 v/v, 10 mM, pH=7.4) before the spectral experiment. The stock solutions of various metal ions (Na+, K+, Zn2+, Mn2+, Ni2+, Ba2+, Pb2+, Hg2+,
-p
Fe2+, Cd2+, Al3+, Ca2+, Ag2+, Cr3+, Mg2+, Cu2+, Fe3+ and Co2+ ions) were used for their
re
nitrates. Anions (F−, Cl−, Br−, I−, SO42−, SO32−, SH−, S2−, NO3−, CO32−, CH3COO−, HCO4−, HSO3−, SCN−, HPO42−) stock solutions were used their sodium salt in
lP
distilled water to configure 1.00×10−3 M. (Due to inorganic phosphate anion (PA) are present with the ratio H2PO4−/HPO42− of 1/4 in human physiology pH [41, 42],
na
HPO42− is taken as the research analyte in this study). The spectral changes of the
Jo ur
mixed solutions of sensors CHP or CHS with various ions were studied by fluorescence and UV absorption spectroscopy at room temperature. The fluorescence emission of CHP and CHS were recorded with excitation at 420 nm.
2.4 MTT assay
The cytotoxicity of CHP or CHS was researched by MTT assay according to reported manner. The PC12 cells were grown Dulbecco's Modified Eagle's medium with containing fetal bovine serum (10 %) at 37 °C and 5% CO2. Then the cells were wished washed with PBS 3 times and incubated with various concentrations of CHP and CHS(0, 20, 40, 60, 80, 100 μM) in 96-well plates at 37 °C for 1 h, respectively. Subsequently, the solution (10 mg mL-1 in PBS buffer) were added in each well plats and incubated at 37 °C for 5 h. The formazan was solubilized in DMSO and the fluorescence of cells was tested enzyme-linked immunosorbent assay reader. 5
Journal Pre-proof
3. Result and discussion 3.1 Spectral characteristics of CHP and CHS toward Zn2+ The selectivity was first investigated of CHP and CHS to different metal ions in DMF/HEPES buffer (5:1 v/v, 10 mM, pH=7.4) (Fig. 1). The compound CHP showed weak fluorescence emission maybe due to the photoinduced electron transfer (PET) process [43] between the imine group and the coumarin group. Then addition of
of
different metal ions (3.0 equiv. of Na+, K+, Zn2+, Mn2+, Ni2+, Ba2+, Pb2+, Hg2+, Fe2+, Cd2+, Al3+, Ca2+, Ag2+, Cr3+, Mg2+, Cu2+, Fe3+ and Co2+ ions) to the solution of CHP,
ro
only Zn2+ caused obvious fluorescent enhancement at 533 nm with the color change
-p
from colorless to yellow. Also for CHS, the fluorescence emission at 510 nm was enhancement in the presence of Zn2+ with the change of color from colorless to yellow.
re
In contrast, the fluorescence spectra of the sensors CHP and CHS did not change
lP
significantly in the presence of other metal ions. These results indicated that the sensors CHP and CHS could be used as fluorescent sensors with a “turn-on”
na
fluorescence change for Zn2+ accompanied by “naked eye recognition”. The ability was also explored of sensors CHP and CHS to detect Zn2+ in the
Jo ur
presence of other metal ions. When 3.0 equiv. of Zn2+ and 3.0 equiv. of other metal ions were added into the sensor CHP or CHS, most of these metal ions did not lead to obviously changes in the detection of Zn2+ (Fig. S9). In general, CHP and CHS have good anti-interference performance for detecting Zn2+ in DMF/HEPES buffered solution (5:1 v/v, 10 mM, pH=7.4).
6
Journal Pre-proof
(B)
Zn2+
300
Fluorescence Intensity(a.u.)
Fluorescence Intensity(a.u.)
(A)
250
200
150
CHP and Li+, Na+, K+, Ag+, Ba2+ Mn2+, Ni2+, Cr3+, Al3+, Cd2+, Ca2+
100
Pb2+, Hg2+, Co2+, Fe3+, Fe2+, Cu2+ Mg2+
50
0 450
500
550
600
650
250
Zn2+
200
150
100
CHS and Li+, Na+, K+, Ag+, Ba2+ Mn2+, Ni2+, Cr3+, Al3+, Cd2+, Ca2+ Pb2+, Hg2+, Co2+, Fe3+, Fe2+, Cu2+ Mg2+
50
0
700
450
500
Wavelength(nm)
550
600
650
Wavelength(nm)
ro
of
Fig. 1. Fluorescent spectra of (A) CHP and (B) CHS (3.33×10−5 M) with various metal ions (3.0 equiv.) in DMF/HEPES buffer (5:1 v/v, 10 mM, pH=7.4). Inset: photograph of fluorescence change of CHP or CHS after addition of Zn2+.
-p
The UV absorption spectra of CHP and CHS with Zn2+ were explored. The Fig. 2 showed that free CHP displayed a sharp and clear absorption band at 320 nm, this was
re
due to π-π* charge transfer in the sensor molecule. Upon gradual addition of Zn2+, the
lP
intensity of the UV absorption peak at 320 nm of the mixed solution gradually weakened, the UV absorption peak at 420 nm was gradually enhanced. And a distinct
na
isosbestic point at 344 nm was appeared. In addition, the mixed solution of sensor CHP and Zn2+ exhibited bright yellow fluorescence under 365 nm UV light (see inset
Jo ur
of Fig. 2), which was caused by the chelation-enhanced fluorescence (CHEF) [44] effect between Zn2+ and CHP. In the same way, absorption peak of CHS displayed a sharp band at 316 nm, after addition of Zn2+ to the solution of CHS, the band at 316 nm was gradually diminished and red-shifted to 350 nm. However, the absorption peak of CHS around 420 nm was gradually enhanced with a new isosbestic point at 346 nm (Fig. S10). The illustration also showed CHS and Zn2+ mixed solution showing bright green fluorescence under 365 nm UV light (see inset of Fig. S10). All the results indicated CHP and CHS with Zn2+ interact to form stable complex, respectively.
7
Journal Pre-proof
1.6 1.4
Absorbance
1.2 1.0 0.8 0.6 0.4 0.2 0.0 300
400
500
Wavelength(nm)
ro
of
Fig. 2. UV–vis spectra of CHP (3.33×10−5 M) upon addition of Zn2+ (0-2.8 equiv.) in DMF/HEPES buffer (5:1 v/v, 10 mM, pH=7.4). Inset: photograph of daylight change of CHP after addition of Zn2+.
-p
The fluorescence properties of CHP and CHS with Zn2+ were further investigated by fluorescence titration experiments, respectively. As shown in Fig. 3A, upon
re
gradual addition of 0 to 2.8 equiv. Zn2+ into the solution of CHP, the fluorescence
lP
emission at 533 nm was increased gradually, which meanly attributed to the PET and –C=N– isomerization processes were restrained [45]. Alike, upon addition of 0 to 2.6
na
equiv. Zn2+ to the solution of CHS, a new fluorescence emission at 510 nm was appeared and enhanced approximate 215-fold (Fig. 3B). The 1:1 complex ratio
Jo ur
between CHP and CHS with Zn2+ were obtained by job's plot (Fig.S11, Fig. S12) [46] and HR-MS experiments. The mass spectra were showed that the peak at m/z 418.9976 and 371.0036 was classified as [CHP+Zn2++NO3−] (Fig. S13) and [CHS+Zn2+-H+] (Fig. S14), respectively. Base on the fluorescence titrations data, the association constants of CHP-Zn2+ and CHS-Zn2+ were estimated to be 3.33×104 M−1 and 8.11×103 M−1 by using the Benesi-Hildebrand plot [47] analysis, respectively (Fig. 4). Moreover, the detection limit (DL = 3/slope) [48] of CHP for Zn2+ and CHS for Zn2+ were calculated to be 1.03×10−7 M (R2 = 0.9886) and 1.87×10−7 M (R2 = 0.9902), respectively (Fig. S15), which were much lower than the limit by WHO [49].
8
Journal Pre-proof
(B) 2.8 eq. Zn
250
200
Fluorescence Intensity(a.u.)
Fluorescence Intensity(a.u.)
(A) 300 2+
200
150
100
50
2.6 equiv. Zn2+ 150
100
50
0
0 450
500
550
600
650
700
450
500
550
600
650
Wavelength(nm)
Wavelength(nm)
0.025
Intercept Slope
y = a + b*x No Weighting 1.23016E-5
0.035
Value Standard Error 0.00248 1.59942E-4 7.43833E-8 1.79332E-9
0.030
0.99597 0.99165
Intercept Slope
B
Value Standard Error 0.00193 1.86211E-4 2.37992E-7 4.20174E-9
-p
B
Equation Weight Residual Sum of Squares Pearson's r Adj. R-Square
(B)0.040
0.99538 0.99021
0.025
0.015
1/(I-I0)
1/(I-I0)
0.020
y = a + b*x No Weighting 4.2246E-6
ro
Equation Weight Residual Sum of Squares Pearson's r Adj. R-Square
(A)
of
Fig. 3. (A) Fluorescence spectra of CHP (3.33×10−5 M) upon addition of Zn2+ (0-2.8 equiv.) in DMF/HEPES buffer (5:1 v/v, 10 mM, pH=7.4); (B) Fluorescence spectra of CHS (3.33×10−5 M) upon addition of Zn2+ (0-2.6 equiv.) in DMF/HEPES buffer (5:1 v/v, 10 mM, pH=7.4).
0.020
re
0.010
0.015 0.010
0
50000
100000
150000
lP
0.005
200000
1/[Zn2+]
250000
300000
0.005 0
20000
40000
60000
80000 100000 120000 140000 160000
1/[Zn2+]
Jo ur
na
Fig. 4. Benesi-Hildebrand plot for (A) CHP and (B) CHS with Zn2+ in DMF/HEPES buffer (5:1 v/v, 10 mM, pH=7.4) solution.
3.2 Effect of pH
In order to investigate the application value of sensors CHP and CHS in identifying Zn2+ in actual samples and biological systems, we conducted the identification of sensors CHP and CHS towards Zn2+ in the range of pH 2-12 (Fig. S16), respectively. When the pH <5 in an acidic environment, CHP and CHS were showed negligible fluorescence intensity to Zn2+, this may due to the deprotonated of coumarin was inhibited. The complexes of CHP-Zn2+ and CHS-Zn2+ maintained a good fluorescence emission at pH 7-11. These results indicated that CHP and CHS had strong fluorescence enhancement response for Zn2+ under weak alkaline conditions.
3.3 Photographs of CHP and CHS after immersion with various concentrations of Zn2+ 9
Journal Pre-proof The“naked eye” fluorescence sensors are paid much attention due to their specific fluorescence response toward the analyte. In view of the obvious fluorescence changes of CHP and CHS with Zn2+, thus, we wondered whether the relative low detection limit of CHP and CHS toward Zn2+ could be captured by the “naked eye”. Hence, various concentrations solutions of Zn2+ were mixed with CHP and CHS and took photos of the fluorescence changes of mixed solutions in visible light and 365 nm UV light, respectively. As shown in Fig. 5A, upon addition of Zn2+ in CHP solution, the color was gradually changed from colorless to yellow, and the
of
fluorescence of mixed solutions were gradually enhanced. The fluorescence change
ro
was very obvious and could be easily observed by the“naked eye”. And the“naked eye” detection limit of CHP toward Zn2+ is 1.00×10−6 M under 365 nm UV light. As
-p
shown in Fig. 5B, the color and fluorescence of mixed solutions were also changed
re
step and step with gradually added Zn2+ ion. The“naked eye” detection limit of CHS
lP
toward Zn2+ is also 1.00×10−6 M by the fluorescence response under 365 nm UV light. This experiment proved that, in the actual sample, the concentration range of the guest
Jo ur
sample.
na
to be tested in the sample can be inferred by comparison with the color of the standard
Fig. 5. (A) photographs of CHP in DMF/HEPES buffer (5:1 v/v, 10 mM, pH=7.4) solutions upon addition various concentrations (10−6-10−1 M) of Zn2+, above: color changes, below: fluorescence changes; (B) photographs of CHS in DMF/HEPES buffer (5:1 v/v, 10 mM, pH=7.4) solutions upon addition various concentrations (10−6-10−1 M) of Zn2+, above: color changes, below: fluorescence changes.
3.4 1H NMR titrations of CHP and CHS toward Zn2+ The complexation mode of CHP-Zn2+ and CHS-Zn2+ complexes were investigated by 1H NMR spectroscopy titrations. As shown in Fig 6, upon gradual addition 1.00 10
Journal Pre-proof equiv. of Zn2+ into the solution of CHP, the 1H NMR spectrum signals significant change. The proton peak (H1) at 9.28 ppm was shifted to 9.35 ppm, the proton peak of H2 did not change significantly. The results indicated that the imine nitrogen atom near the pyridine group participated in the complexation with Zn2+. Furthermore, the proton peaks H3 and H4 on the pyridine ring were shifted from 7.99 ppm and 7.56 ppm to 8.04 ppm and 7.63 ppm, respectively. The changes of these signal peaks indicated that the nitrogen atom on the pyridine ring also participated in the bonding with Zn2+. And the phenolic hydroxyl (H5) of coumarin was gradually disappeared
of
which manifested the oxygen atom of phenolic was also bonded with Zn2+.Similarly,
ro
after adding 1.0 equiv. of Zn2+ to the solution of sensor CHS, H6 at 9.31 ppm and H7 at 9.10 ppm were shifted to 9.25 ppm and 9.04 ppm, respectively (Fig.S17). These
-p
results indicated that the nitrogen atoms on the imine (-C=N-) group participated in
re
the complexation with Zn2+. The phenolic hydroxyls of coumarin and benzene were
lP
gradually disappeared with adding Zn2+, these results indicated that the oxygen atoms of the benzene phenolic hydroxyl group and coumarin phenolic hydroxyl participated
Jo ur
na
in the complexation with Zn2+.
Fig. 6. 1H NMR spectrum of CHP, CHP+Zn2+ (0.5 equiv.) and CHP+Zn2+ (1.0 equiv.) in DMSO-d6 solution (from bottom to top).
3.5 Theoretical calculations The structures of sensors CHP, CHS and their complexes CHP-Zn2+, CHS-Zn2+ were optimized by the Gaussian 09 software at DFT/B3LYP/6-31G (d, p) level. The theoretical calculations were guided from the binding model which were analyzed by spectroscopy experiments. The optimized structures of CHP and CHP-Zn2+ were 11
Journal Pre-proof showed in Fig. 7 and Fig. S18, the deprotonated O atom of coumarin hydroxyl and two N atoms of pyridine and imine were coordinated with Zn2+, respectively. Furthermore, an accessional coordination bond was shaped between Zn2+ and the O atom of nitrate anion based on this experiment condition and the HRMS analysis. For CHS and CHS-Zn2+, the CHS also used the N atoms of imine and two deprotonated O atoms of phenol hydroxyl and coumarin hydroxyl to coordinate with Zn2+.The distance of the N-Zn2+ and O-Zn2+ were in the range of 1.92-2.22 Å, respectively (Fig 7, Fig. S18). These bond length accord with typical coordination bond distances [50]
of
which indicated the synergetic system of CHP-Zn2+ and CHS-Zn2+ were formed.
ro
The electronic transitions of CHP, CHS and the CHP-Zn2+, CHS-Zn2+ complexes were further calculated by TD-DFT. For CHP and CHS, the HOMO mainly
-p
distributed in imine group while the LUMO were dispersed the whole CHP and CHS
re
molecules. The PET process form electron donor (imine group) to the acceptor (fluorophore) were manifested by transitions of HOMO to LUMO. For CHP-Zn2+ and
lP
CHS-Zn2+ complexes, LUMO were not completely occupied the fluorophore due to
na
the metal-ligand electronic transitions, which generated the PET process were restrained and fluorescence emission of CHP and CHS were distinctly enhanced. The
Jo ur
calculated HOMO–LUMO energy gap of CHP-Zn2+ (2.67 eV) and CHS-Zn2+ (3.38 eV) complexes were low than the gap of CHP (3.73 eV) and CHS (3.66 eV), respectively (Fig 7, Fig. S18), which indicated that the CHP-Zn2+ and CHS-Zn2+ complexes were much stabilized than CHP and CHS, and the formation of the CHP-Zn2+ and CHS-Zn2+ complexes were energetically favorable. The theoretical calculation results were further confirmed the sensing mechanism of CHP and CHS to Zn2+ (Scheme 2 and Scheme 3).
12
of
Journal Pre-proof
-p
ro
Fig. 7. (A) The optimized structures and frontier orbitals of CHP and CHP-Zn2+.
re
3.6. Spectroscopic studies of CHP-Zn2+ and CHS-Zn2+ complexes toward phosphate anion
lP
In order to study whether the complexes CHP-Zn2+ or CHS-Zn2+ can be used as a secondary anion fluorescent sensor, the fluorescence responses were investigated of
na
complexes CHP-Zn2+ and CHS-Zn2+ towards F−, Cl−, Br−, I−, SO42−, SO32−, HS−, S2−, NO3−, CO32−, CH3COO−, S2O82-, HCO3−, ClO−, SCN−, citrate, PA in DMF/HEPES
Jo ur
buffer (5:1 v/v, 10 mM, pH=7.4) solution. As shown in Fig. 8, the same equiv. of different anions were added into the complexes CHP-Zn2+ and CHS-Zn2+, respectively. Interestingly, the fluorescence spectra of the mixed solutions were not significant change except for PA. When the PA added, the fluorescence of the complexes CHP-Zn2+ and CHS-Zn2+ solutions were all quenched and returned to the same fluorescence intensity as the sensors CHP and CHS. In addition, the color of the mixed solutions also changed from yellow to colorless. These results indicated that the complexes CHP-Zn2+ and CHS-Zn2+ can be used as a “turn-off” type fluorescent sensor to achieve selective detection of PA.
13
Journal Pre-proof
350
(B) 300
250
Fluorescence Intensity(a.u.)
Fluorescence Intensity(a.u.)
(A)
CHP-Zn2+,F-, Cl-, Br-, I-, SO42-, SO32-, NO3-,CO32-, CH3COO-, HCO3-, HSO4-, ClO-, S2-, HS-, SCN-, S2O82- citrate
200
150
100
250
200
CHS-Zn2+, F-, Cl-, Br-, I-, SO42-, SO32-, NO3-, CO32-, CH3COOHCO3-, HSO4-, ClO-, S2-, SH-, SCN-, S O 2- citrate
150
100
2
8
50
50
0 450
300
HPO42-
HPO42500
550
600
650
700
0 450
500
Wavelength(nm)
550
600
650
Wavelength(nm)
ro
of
Fig. 8. (A) Fluorescent spectra of CHP-Zn2+ (3.33×10-5 M) with various anions (3.0 equiv.) in DMF/HEPES buffer (5:1 v/v, 10 mM, pH=7.4). Inset: photograph of color change of CHP-Zn2+ after addition of phosphate anion; (B) Fluorescent spectra of CHS-Zn2+ (3.33×10-5 M) with various anions (3.0 equiv.) in DMF/HEPES buffer (5:1 v/v, 10 mM, pH=7.4). Inset: photograph of fluorescence change of CHS-Zn2+ after addition of phosphate anion.
-p
The sensing mechanism of CHP-Zn2+ and CHS-Zn2+ toward PA were inspected in
re
DMF/HEPES buffer (5:1 v/v, 10 mM, pH=7.4) solution by UV absorption and fluorescence titration experiments, respectively. Fig. 9 showed, with the increasing
lP
concentrations of PA, the absorption peak of complex CHP-Zn2+ solution at 320 nm
na
was gradually enhanced and the peak at 420 nm was simultaneously subdued. Eventually the peak restored to a position consistent with the free CHP UV absorption
Jo ur
spectrum. Similarly, upon addition of PA into complex solution of CHS-Zn2+, the absorption peak of complex solution of CHS-Zn2+ was also regained to as free CHS (Fig. S19). In addition, the color of complexes solutions of CHP-Zn2+ and CHS-Zn2+ were quenched in the presence of PA (see insert of Fig. 9). Considering the appearance above, PA grab Zn2+ from CHP-Zn2+ or CHS-Zn2+ complexes and make sensors free.
14
Journal Pre-proof
(A)
1.4
1.2
Absorbance
1.0
0.8
0.6
0.4
0.2
0.0 300
400
500
Wavelength(nm)
ro
of
Fig. 9. UV–vis spectra of CHP-Zn2+ (3.33×10−5 M) upon addition of phosphate anion (0-2.8 equiv.) in DMF/HEPES buffer (5:1 v/v, 10 mM, pH=7.4). Inset: photograph of daylight change of CHP-Zn2+ after addition of phosphate anion.
-p
The fluorescence titrations for CHP-Zn2+ and CHS-Zn2+ with PA were also performed. As shown in Fig. 10, upon gradually increased the concentration of
re
HPO42−, the fluorescence emission of solutions of CHP-Zn2+ and CHS-Zn2+ were also
lP
gradually subdued, which indicated that the Zn2+ of the complexes CHP-Zn2+ and CHS-Zn2+ were “captured” by PA to release free sensors CHP and CHS. The DL for
na
PA were calculated to be 2.07×10−7 M (R2=0.9928) and 2.63×10−7 M (R2=0.9954) based on fluorescence titrations data with 3/slope formula [51], respectively (Fig.
Jo ur
S20). The sensing mechanisms of CHP or CHS with Zn2+ and HPO42− were proposed combined with the analysis of above results (Scheme 2 and Scheme 3). 300
250
(B) 200
Fluorescence Intensity(a.u.)
Fluorescence Intensity(a.u.)
(A)
200
150
2.8 eq. HPO42-
100
50
0
150
2.0 eq. HPO42-
100
50
0
450
500
550
600
650
700
450
500
550
600
650
Wavelength(nm)
Wavelength(nm)
Fig. 10. (A) Fluorescence spectra of CHP-Zn2+ (3.33×10−5 M) upon addition of phosphate anion (0-2.8 equiv.) in DMF/HEPES buffer (5:1 v/v, 10 mM, pH=7.4); (B) Fluorescence spectra of CHS-Zn2+ (3.33×10−5 M) upon addition of phosphate anion (0-2.0 equiv.) in DMF/HEPES buffer (5:1 v/v, 10 mM, pH=7.4).
15
Journal Pre-proof
ro
of
Scheme 2. Proposed binding and sensing mechanism of CHP with Zn2+ and PA.
-p
Scheme 3. Proposed binding and sensing mechanism of CHS with Zn2+ and PA.
re
3.7 Reversibility studies and logic gates behavior
The reversibility fluorescence response was investigated through alternately adding
lP
Zn2+ and PA into the solutions of sensors CHP and CHS, respectively. Zn2+ was first added to the solutions of sensors CHP or CHS, and the fluorescence of the solutions
na
of CHP and CHS were enhanced and exhibited strong yellow and green fluorescence under 365 nm UV-light. After adding PA to the solutions above, the fluorescence
Jo ur
emission of which was all quenched. When Zn2+ was added more to the solutions, the fluorescence emission of solutions of CHP and CHS at 533 nm and 510 nm were enhanced again due to the competitive combination of Zn2+ and PA. The fluorescence efficiency of the sensors CHP and CHS for identifying Zn2+ and PA was still high after several times (Fig. 11 and Fig. S21). The sensors CHP and CHS could be repeated to be used for detecting Zn2+ and PA.
Fig. 11. Fluorescence spectra changes of CHP after alternating addition of Zn2+ and phosphate 16
Journal Pre-proof anion in DMF/HEPES buffer (5:1 v/v, 10 mM, pH=7.4) solution. Inset: visual fluorescence changes of alternating addition of Zn2+ and phosphate anion.
In view of the photosensitive characteristics between the sensors CHP, CHS with Zn2+ and PA, the abilities of sensors CHP and CHS could be built a combinatorial logic gate that contained specifically logic functions AND & NOT [52]. Zn2+ (IN 1) and PA (IN 2) could be defined as input signals and the fluorescence emission of sensors CHP and CHS at 533 nm and 510 nm were defined as output signals,
of
respectively. The existence of Zn2+ or PA was defined as 1, and the absence of Zn2+ or HPO42− was defined as 0. The quenching and enhancement of the fluorescence signals
ro
of sensors CHP and CHS at 533 nm and 510 nm were defined as 0 and 1 respectively.
-p
As shown in Scheme 4, the fluorescence enhancement (output 1) of CHP and CHS in the presence of input IN 1, the fluorescence quenching (output 0) of CHP and CHS in
re
the presence of both input IN 1 and IN 2. The fluorescent behavior of CHP and CHS
lP
were expired by an INHIBIT logic function. Input
IN 2
na
IN 1
output OUT
(PA)
Fluorescence emission
0
0
0
0
1
0
1
0
1
1
1
0
Jo ur
(Zn2+)
Scheme 4. INHIBIT logic gate for CHP and CHS with two inputs (IN 1=Zn2+, IN 2=HPO42−)
3.8 Cell imaging study Due to the excellent fluorescence response of the sensors CHP and CHS to Zn2+ and their complexes CHP-Zn2+ and CHS-Zn2+ to PA in aqueous buffered solutions. The biological applications of CHP and CHS were further assessed by intracellular 17
Journal Pre-proof imaging test, respectively. Firstly, the cytotoxicity of CHP and CHS were assessed by MTT assays in PC12 cells. As shown in Fig. S22 and Fig. S23, diverse concentrations (0-120 μM) of CHP and CHS were incubated with PC12 cells for 5h at 37 ℃, respectively. When the concentrations of CHP and CHS below of 60 μM had almost no virulence for PC12 cells (Fig. 12 and Fig. S24). PC12 cells were incubated in sterile PBS buffer (pH=7.4) containing 20 μM CHP and CHS for 20 minutes at 37 ℃, respectively. Then the bright field and dark field images of cells were observed under a fluorescence microscope, as shown in Fig. 12A2 and Fig. S24D2, cellular image
of
showed no fluorescence. While the cells were further incubated with 40 μM Zn2+ for
ro
30 minutes at 37 ℃ and washed with PBS buffer three times. As shown in Fig. 12B2 and Fig. S34E2, the green fluorescence of cells was observed under the microscope,
-p
respectively. In addition, we continued to add 40 μM of PA to the cell culture medium
re
containing the complexes CHP-Zn2+ and CHS-Zn2+ and incubated for 20 minutes,
lP
respectively. Then the green fluorescence of cell was quenched (Fig. 12C2 and Fig. S24F2). Overall results indicated that CHP and CHS could be used as sensors to
Jo ur
na
monitor Zn2+ and PA in living cells.
Fig. 12. (A1) Bright field image of living PC12 cells treated with CHP (20 μM CHP); (A2) Fluorescence image of A1; (B1) Bright field image of living PC12 cells treated with CHP (20 μM CHP) and Zn2+ (40 μM); (B2) Fluorescence image of B1; (C1) Bright field image of living PC12 cells treated with CHP (20 μM CHP) and Zn2+ (40 μM) again incubated phosphate anion (40 μM); (C2) Fluorescence image of C1.
4. Conclusion In summary, we designed and synthesized two coumarin-based Schiff base 18
Journal Pre-proof fluorescence sensors CHP and CHS which revealed selectivity and sensitivity for Zn2+ with “naked eye” detection in buffered solution. Furthermore, the complexes CHP-Zn2+ and CHS-Zn2+ could also act as sensors for detecting phosphate anion. The binding mechanism of sensors with Zn2+ and phosphate anion were affirmed by spectroscopic technique, HRMS experiment and theoretical calculation. And the sensors CHP and CHS showed “Off−On−Off” fluorescence switching response with Zn2+ and phosphate anion, the INHIBIT logic gate were constructed to monitor fluorescence emission of CHP and CHS with Zn2+ and phosphate anion as chemical
of
inputs. Moreover, the abilities of sensors CHP and CHS of detecting intracellular Zn 2+
-p
ro
and phosphate anion were successfully applied.
Acknowledgements
re
We thank the Natural Science Foundation of China (No. U1404207) for financial
Jo ur
na
lP
support.
19
Journal Pre-proof
References [1] S.A. Snyder, T.L. Keith, D.A. Verbrugge, E.M. Snyder, T.S. Gross, K. Kannan, Analytical methods for detection of selected estrogenic compounds in aqueous mixtures, Environ. Sci. Technol. 33 (1999) 2814–2820. [2] P. Wang, X.Y. Liu, J.X. Fu, Y.X. Chang, L. Yang, K.X. Xu, Synthesis and fluorescence spectral studies of novel quinolylbenzothiazole-based sensors for selective detection of Fe3+ ion, Can. J. Chem. 96 (2018) 835–841.
of
[3] J.J. Tan, S.B. He, S.H. Yan, Y.N. Li, H. Li, H. Zhang, L. Zhao, L.J. Li, Exogenous EDDS modifies copper-induced various toxic responses in rice, Protoplasma,
ro
251 (2014) 1213–1221.
-p
[4] T.W. Xiao, M.M. Mi, C.Y. Wang, M. Qian, Y.H. Chen, L.Q. Zheng, H.S. Zhang, Z.B. Hu, Z.G. Shen, Y. Xia, A methionine-R-sulfoxide reductase, OsMSRB5, is
re
required for rice defense against copper toxicity, Environ. Exp. Bot. 153 (2018) 45–53.
lP
[5] W. Gao, F.C. Xu, D.D. Guo, J.R. Zhao, J. Liu, Y.W. Guo, P.K. Singh, X.N. Ma, L. Long, J.R. Botella, C.P. Song, Calcium-dependent protein kinases in cotton:
na
insights into early plant responses to salt stress, BMC Plant Biol., 18 (2018) 15. [6] B. Peng, D. Wu, J. Lai, H. Xiao, P. Li, Simultaneous determination of halogens (F,
Jo ur
Cl, Br, and I) in coal using pyrohydrolysis combined with ion chromatography, Fuel 94 (2012) 629–631.
[7] Y. Guo, B.J. Din, Y.W. Liu, X.J. Chang, S.M. Meng, M.Z. Tian, Preconcentration oftrace metals with 2-(methylthio)aniline-functionalized XAD-2 and their determination by flame atomic absorption spectrometry, Anal. Chim. Acta 504 (2004) 319–324. [8] L.J. Melnyk, J.N. Morgan, R. Fernando, E.D. Pellizzari, O. Akinbo, Determination of metals in composite diet samples by inductively coupled plasma-mass spectrometry, J. AOAC Int. 86 (2003) 439–447. [9] H.Z. Lian, Y.F. Kang, S.P. Bi, Y. Arkin, D. Shao, D. Li, Y.J. Chen, L.M. Dai, N. Gan, L. Tian, Direct determination of trace aluminum with quercetin by reversed-phasehigh performance liquid chromatography, Talanta 62 (2004) 43– 20
Journal Pre-proof 50. [10] P. Torawane, K. Tayade, S. Bothra, S.K. Sahoo, N. Singh, A. Borse, A. Kuwar, A highly selective and sensitive fluorescent ‘turn-on’ chemosensor for Al3+ based on CN isomerisation mechanism with nanomolar detection, Sens. Actuators B 222 (2016) 562–566. [11] F. Yu, L.J. Hou, L.Y. Qin, J.B. Chao, Y. Wang, W.J. Jin, A new colorimetric and turn-on fluorescent chemosensor for Al3+ in aqueous medium and its application in live-cell imaging, J. Photochem. Photobiol. A 315 (2016) 8–13.
of
[12] Y.X. Chang, J.X. Fu, K. Yao, B. Li, K.X. Xu, X.B. Pang, Novel fluorescent
ro
probes for sequential detection of Cu2+ and citrate anionand application in living cell imaging, Dyes Pigments 161 (2019) 331–340.
-p
[13] X.Y. Liu, J.X. Fu, K. Yao, Y.X. Chang, K.X. Xu, L. Yang, Phenanthroline-based
re
fluorescence sensors for Eu3+ ion and subsequent enantioselective discriminating
lP
of malate, Supromol. Chem. 30 (2018) 994–1003. [14] P. Wang, K. Yao, J.X. Fu, Y.X. Chang, B. Li, K.X. Xu, Novel fluorescent probes
na
for relay detection copper/citrate ion and application in cell imaging, Spectrochim. Acta A 211 (2019) 9–17.
Jo ur
[15] P.S. Hariharan, S.P. Anthony, Selective turn-on fluorescence for Zn2+ and Cd2+ metal ions by single Schiff base chemosensor. Anal. Chim. Acta. 848 (2014) 74– 79.
[16] P.J. Jiang, Z.J. Guo, Fluorescent detection of zinc in biological systems: recent development on the design of chemosensors and biosensors, Coord. Chem. Rev. 248 (2004) 205–229. [17] K. Hanaoka, Y. Muramatsu, Y. Urano, T. Terai, T. Nagano. Design and synthesis of ahighly sensitive off-on fluorescent chemosensor for zinc ions utilizing internal charge transfer, Chem. Eur. J. 16 (2010) 568–572. [18] J.J. Lee, S.A. Lee, H. Kim, L. Nguyen, I. Noh, C. Kim, A highly selective CHEF-type chemosensor for monitoring Zn2+ in aqueous solution and living cells, RSC Adv. 5 (2015) 41905–41913. [19] L.H. Xu, W.Y. Wang, J.J. Guo, J. Qin, D.Q. Shi, Y.L. Li, J. Xu, Zinc improves 21
Journal Pre-proof salt tolerance by increasing reactive oxygen species scavenging and reducing Na+ accumulation in wheat seedlings, Biol. Plantarum 58 (2014) 751–757. [20] Z. Xu, G.H. Kim, S.J. Han, M.J. Jou, C. Lee, I. Shin, An NBD-based colorimetric and fluorescent chemosensor for Zn2+ and its use for detection of intracellular zinc ions, Tetrahedron 65 (2009) 2307–23012. [21] M. Hosseini, A. Ghafarloo, M.R. Ganjali, F. Faridbod, P. Norouzi, M.S. Niasari, Aturn-on fluorescent sensor for Zn2+ based on new Schiff’s base derivative inaqueous media, Sens. Actuators B Chem. 198 (2014) 411–415.
of
[22] E.L. Que, D.W. Domaille, C.J. Chang, Metals in neurobiology: probing their
ro
chemistry and biology with molecular imaging, Chem. Rev. 108 (2008) 1517– 1549.
re
Chem. Eur. J. 11 (2005) 38–49.
-p
[23] N.C. Lim, H.C. Freake, C. Bruckner, Illuminating zinc in biological systems,
lP
[24] Z.C. Xu, J.Y. Yoon, D.R. Spring, Fluorescent chemosensors for Zn2+, Chem. Soc. Rev. 39 (2010) 1996–2006.
na
[25] J.F. Zhang, S. Kim, J.H. Han, S.J. Lee, T. Pradhan, Q.Y. Cao, Pyrophosphate-selective
fluorescent
chemosensor
based
on
1,
Jo ur
8-naphthalimide-DPA-Zn(II) complex and its application for cell imaging. Org. Lett.13 (2011) 5294–5297.
[26] K. Wang, J.N. He, Y. Zhao, T. Wu, X.F. Zhou, Y.L. Ding, L.Y. Kong, X.J. Wang, Y. Wang, J.G. Li, C.P. Song, B.S. Wang, S.H. Yang, J.K. Zhu, Z.Z. Gong, EAR1 negatively regulates ABA signaling by enhancing 2C protein phosphatase activity, Plant Cell, 2018, 30, 815-834. [27] S. Khoshniat, A. Bourgine, M. Julien, P. Weiss, J. Guicheux, L. Beck, The emergence of phosphate as a specific signaling molecule in bone and other cell types in mammals, Cell. Mol. Life Sci. 68 (2010) 205–218. [28] C. Bergwitz, H. Jüppner, Phosphate sensing, Adv. Chronic Kidney Dis. 18 (2011) 132–144. [29] Y.P. Dai, P. Wang, J.X. Fu, K. Yao, K.X. Xu, X.B. Pang, A quinoline-based Cu2+ ion complex fluorescence probe for selective detection of inorganic phosphate 22
Journal Pre-proof anion in aqueous solution and its application to living cells, Spectrochim. Acta A, 183 (2017) 30–36. [30] X.H. Luo, X.Y. Li, Y. Wang, X.M. Xie, L. Yang, A novel reversible fluorescent probe for sequential detection of aluminium ion and PPi and bioimaging in living cells, ChemistrySelect 4 (2019) 10643–10648. [31] S.L. Wiskur, H. Ait-Haddou, J.J. Lavigne, E.V. Anslyn, Teaching old indicators new tricks, Acc. Chem. Res. 34 (2001) 963–972. [32] H.T. Ngo, X. Liu, K.A. Jolliffe, Anion recognition and sensing with
of
Zn(II)-dipicolylamine complexes, Chem. Soc. Rev. 41 (2012) 4928–4965.
ro
[33] C.X. Yuan, S.Y. Li, Y.B. Wu, L.P. Lu, M.L. Zhu, Zn(II)-selective and sensitive
Actuators B 242 (2017) 1035–1042.
-p
fluorescent chemosensor based on steric constrains and inhibition of ESIPT, Sens.
re
[34] J.H. Kim, J.Y. Noh, I.H. Hwang, J. Kang, J. Kim, C. Kim, An anthracene-based fluorescent chemosensor for Zn2+, Tetrahedron Letters 54 (2013) 2415–2418.
lP
[35] B.K. Datta, S. Mukherjee, C. Kar, A. Ramesh, G. Das, Zn2+ and pyrophosphate
na
sensing: selective detection in physiological conditions and application in DNA-Based estimation of bacterial cell numbers, Anal. Chem. 85 (2013)
Jo ur
8369-8375.
[36] H.Y. Liu, Y.S. Dong, B.B. Zhang, F. Liu, C.Y. Tan, Y. Tan, Y.Y. Jiang, An efficient quinoline-based fluorescence sensor for zinc(II) and its application in live-cell imaging, Sens. Actuators B 234 (2016) 616–624. [37] M. Shyamal, P. Mazumdar, S. Maity, S. Samanta, G.P. Sahoo, A. Misra , Highly selective turn-on fluorogenic chemosensor for robust quantification of Zn(II) based on aggregation induced emission enhancement feature, ACS Sens. 1 (2016) 739-747. [38] C. Patra, A.K. Bhanja, C. Sen, D. Ojha, V. thioether, Schiff base as a turn-on fluorescence sensor to Zn2+ ion with living cell imaging, Sens. Actuators B 228 (2016) 287–294. [39] Y. Xia, H.H. Zhang, X.J. Zhu, Q. Zhang, M. Fang, X.W. Li, H.P. Zhou, X.Y. Yang, X.J. Zhang, Y.P. Tian, Two-photon fluorescent probe with enhanced 23
Journal Pre-proof absorption cross section for relay recognition of Zn2+/P2O74- and in vivo imaging, Spectrochim. Acta Part A 204 (2018) 446–451. [40] K. Yao, Y.X. Chang, B. Li, H. Yang, K.X. Xu, A novel coumarin-based fluorescent sensor for Ca2+ and sequential detection of F- and its live cell imaging, Spectrochim. Acta A 216 (2019) 385–394. [41] S. Khoshniat, A. Bourgine, M. Julien, P. Weiss, J. Guicheux, L. Beck, The emergence of phosphate as a specific signaling molecule in bone and other cell types in mammals, Cell. Mol. Life Sci. 68 (2011) 205–218.
of
[42] V. Borse, P. Jain, M. Sadawana, R. Srivastava, ‘Turn-on’ fluorescence assay for
ro
inorganic phosphate sensing, Sens. Actuators B 225 (2016) 340–347. [43] H. Lee, H.S. Lee, J.H. Reibenspies, R.D. Hancock, Mechanism of
-p
“turn-on”fluorescent sensors for mercury(II) in solution and its implications for
re
liganddesign, Inorg. Chem. 51 (2012) 10904–10915. [44] M. Hagimori, N. Mizuyama, Y. Yamaguchi, H. Saji, Y. Tominaga, A novel
lP
smallmolecule fluorescent sensor for Zn2+ based on pyridine-pyridone scaffold. Talanta 83 (2011) 1730–1735.
na
[45] D. Bhriguram, J. Atanu, D.M. Ananya, Fluorescein derived Schiff base as fluorimetric zinc (II) sensor via ‘turn on’ response and its application in live cell
Jo ur
imaging, Spectrochim. Acta A 212 (2019) 222–231. [46] Y.P. Dai, K. Yao, J.X. Fu, K Xue, Y. Li, K.X Xu, A novel 2-(Hydroxymethyl)quinolin-8-ol-based selective and Sensitive fluorescence probe for Cd2+ ion in water and living cells, Sens. Actuators B 251 (2017) 877– 884. [47] Y.P. Dai, K. Xu, C.Y. Wang, X.Y. Liu, P. Wang, Study on the synthesis of novel fluorescentmacrocyclic sensors and their sensitive properties for Cu2+ and Fe3+ in aqueous solution, Supramol. Chem. 29 (2017) 315–322. [48] L. Wang, W. Qin, X. Tang, W. Dou, W. Liu, Q. Teng, X. Yao, A selective, cell permeable fluorescent probe for Al3+ in living cells, Org. Biomol. Chem. 8 (2010) 3751–3757. [49] C. Patra, A.K. Bhanja, C. Sen, D. Ojha, D. Chattopadhyay, A. Mahapatra, C. 24
Journal Pre-proof Sinha, Vanillinyl thioether Schiff base as a turn-on fluorescence sensor to Zn2+, ion with living cell imaging, Sens. Actuators B 228 (2016) 287–294. [50] F. Wang, J.H. Moon, R. Nandhakumar, B.T. Kang, D. Kim, K.M. Kim, J.Y. Lee, J. Yoon, Zn2+-induced conformational changes in a binaphthyl-pyrene derivative monitored by using fluorescence and CD spectroscopy, Chem. Commun. 49 (2013) 7228–7230. [51] U. Fegade, A. Saini, S.K. Sahoo, N. Singh, R. Bendre, A. Kuwar, 2,2 0-(hydrazine-1,2-diylidenedimethylylidene)bis(6-isopropyl-3-methylphenol) based selective dual-channel chemosensor for Cu2+ in semi-aqueous media, RSC
of
Adv. 4 (2014) 39639–39644.
ro
[52] T. Gunnlaugsson, D.A. Mac Dónaill, D. Parker, Lanthanide macrocyclic quinolyl conjugates as luminescent molecular-level devices, J. Am. Chem. Soc.123 (2001)
Jo ur
na
lP
re
-p
12866–12876.
25
Journal Pre-proof
Jo ur
na
lP
re
-p
ro
of
Declaration of interests The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
26
Journal Pre-proof Graphical abstract
Two novel coumarin based fluorescent sensors CHP and CHS have been
of
synthesized for the sequential detection of Zn2+ and phosphate anion (PA) in
ro
DMF/HEPES buffer medium (1/5 v/v, 10 mM, pH=7.4). On the addition of Zn2+ ion to the solution of CHP or CHS resulted in a pronounced fluorescence enhancement,
-p
accompanying noticeable color change (under UV or daylight), while there was
re
hardly obvious change with other competing metal ions co-existing. The detection limits (DL) of CHP and CHS towards Zn2+ were separately determined as 1.03×10-7
lP
(R2 = 0.9886) and 1.87×10−7 (R2 = 0.9902). The PET binding processes were affirmed by spectroscopic techniques, HRMS experiments and theoretical calculations.
na
Subsequently, the CHP-Zn2+ or CHS-Zn2+ complexes showed high selectivity fluorescence quenching toward PA by snatching Zn2+ ion from its complex and the
Jo ur
binding processes were reversible. DLs were calculated as 2.07×10−7 M (R2 = 0.9928) and 2.63×10−7 M (R2 = 0.9954), respectively. Furthermore, the cell imaging experiments demonstrated that the sensors were capable of detecting of Zn2+ and PA in vitro cells.
27
Journal Pre-proof Highlights 1. Two novel Schiff base fluorescent sensors CHP and CHS were synthesized. 2. The sensors CHP and CHS for the sequentially detected of Zn2+ and phosphate anion in aqueous solutions. 3. The binding modes of sensors CHP and CHS with Zn2+ ion had been well demonstrated by ESI-MS, 1H NMR and DFT calculation. 4. The sensor CPM was almost no toxicity and could be used to monitor Zn2+ and
Jo ur
na
lP
re
-p
ro
of
phosphate anion in living cells.
28