Dynamic Knee Rotation - A Novel Way to Quantify Stability in the Gait Laboratory

Dynamic Knee Rotation - A Novel Way to Quantify Stability in the Gait Laboratory

2017 ISAKOS ABSTRACTS e149 Category: Knee - Other Paper #223: Dynamic Knee Rotation - A Novel Way to Quantify Stability in the Gait Laboratory KAH W...

156KB Sizes 0 Downloads 33 Views

2017 ISAKOS ABSTRACTS

e149

Category: Knee - Other Paper #223: Dynamic Knee Rotation - A Novel Way to Quantify Stability in the Gait Laboratory KAH WENG LAI, FRCSED (ORTHO), SINGAPORE DARREN KOH, MBBS (S’PORE), SINGAPORE ERICA KHOLINNE, MD, INDONESIA National University Hospital, Singapore, Singapore, SINGAPORE

therefore serve as a tool to assess and guide patients’ postop rehabilitation progress, which is especially relevant in high-level athletes. This method could eventually be expanded to be used as an objective tool to compare different ACL reconstruction techniques and graft choices. Conclusion: Analysis of motion capture with peak GRF measurement in the gait laboratory can serve as a useful and objective tool to quantify the dynamic rotational stability of the knee joint.

SUMMARY After an ACL tear or reconstruction, there is no objective method to measure knee stability. Our study attempts to utilise a novel approach to assess the dynamic rotational function of the knee in the gait laboratory.

Category: Knee - Arthroplasty Paper #224: The Effect of Total Knee Arthroplasty on Active Knee Extension During Treadmill Walking DAVID ANTHONY PARKER, MBBS, BMEDSCI, FRACS, AUSTRALIA AARON BEACH, PHD, AUSTRALIA MYLES RAPHAEL JAMES COOLICAN, FRACS, AUSTRALIA BRETT A. FRITSCH, MBBS, BSC(MED), AUSTRALIA COREY SCHOLES, PHD, AUSTRALIA Sydney Orthopaedic Research Institute, Chatswood, NSW, AUSTRALIA

ABSTRACT DATA Background: Reconstruction of the torn ACL aims to restore the antero-posterior and dynamic rotational stability of the knee joint. The KT-1000 is commonly used as an objective measure of antero-posterior translation. However, no objective tools are available to assess dynamic rotational function. The pivot-shift test is commonly used to assess rotational stability, but suffers from low sensitivity and poor reproducibility in clinic. There is currently no quantifiable way to assess the dynamic rotation stability of ACL-reconstructed knees. Method: This study uses a novel method to quantify the dynamic rotational stability of ACL-deficient and ACLreconstructed knees compared to normal. Recordings of lower extremity gait patterns were captured using an established motion capture gait analysis program (Vicon Nexus) for three groups of patients - normal (10 patients), ACL-deficient (10 patients, 3-months post-injury) and ACL-reconstructed (10 patients, 1-year post-op). This was done in conjunction with floor-mounted force plates to measure the peak ground reaction force (GRF), over 3 different movement protocols. Data was collected for maximum knee rotation angle when turning, peak GFR on ground impact, knee rotation angle on ground impact and the total range of rotation. This data was compared to the subjects’ other (normal) knee, as well as the subjects with intact ACLs. Results: Preliminary results show that, although ACLdeficient patients have similar maximum knee rotation angles on turning as normal patients, there is a 15 % lower peak GRF and a 5-degree greater knee rotation angle on ground impact. As for the ACL-reconstructed subjects, they continue to demonstrate a small difference in peak GRF (1-2 Newtons lower) on ground impact compared to the normal group. More importantly, there is no increase in the knee rotation angle on impact for the reconstructed knee compared to normal subjects. Discussion: The data so far shows that even at 1-year post-op, ACL-reconstructed patients could not achieve the same dynamic function as normal subjects. Motion capture analysis coupled with peak GRF can help to quantify the dynamic rotational function of the knee joint and

SUMMARY Determination of whether patients who receive full extension following a TKA use this full range of motion when they commence pain-free walking post-operatively. ABSTRACT DATA Background: Fixed flexion contracture of the knee due to osteoarthritis is common in patients requiring a total knee arthroplasty (TKA). This is detrimental to overall knee function and increases energy expenditure during walking. Individuals may also consciously limit extension during walking to minimize pain or avoid joint instability. TKA is a well-established procedure for restoring extension, however there is a suspicion that despite receiving a knee capable of achieving full extension, patients do not utilise this capability post-operatively. The purpose of this study was to determine whether patients who receive full extension following a TKA use this full range of motion when they commence pain-free walking post-operatively. Materials & Methods: Gait analysis of patients undergoing unilateral TKR was conducted prior to surgery and repeated when they commenced pain-free locomotion. A high-speed optoelectronic camera system (200Hz, Vicon Bonita/Nexus, UK) was used to record maximum knee extension of the operated limb during standing and while supine (passive knee extension), step-descent onto the injured limb from a 20cm high step, as well as treadmill walking at both a self-selected comfortable speed and 130% (“fast”) of that speed for one minute each. Student t-tests were used to compare differences between preoperative and post-operative values for the cohort aggregated and for each patient (single-case). Results: A cohort of 24 patients (15 females; 70.86.5yrs; 168.88.9cm; 8413.2kg) was assessed before, during and 4.70.5 months after surgery. On average, patients