Electronic manometer measures minute pressures

Electronic manometer measures minute pressures

VACUUM Classified A b s t r a c t s II --- Vacuum Apparatus and Auxiliaries Contd. -- II Abstract No. and References The p u m p i n g action of...

108KB Sizes 0 Downloads 88 Views

VACUUM Classified A b s t r a c t s

II ---

Vacuum Apparatus and Auxiliaries Contd.

--

II

Abstract No. and References

The p u m p i n g action of these gauges for oxygen has been investigated. The expected rate of oxygen adsorption has been calculated to be 0.26 litres/second. This is r o u g h l y confirmed b y e x p e r i m e n t . . The p u m p i n g of v a p o u r s and gases originating f r o m t h e diffusion p u m p is based on a s o m e w h a t different m e c h a n i s m from t h a t a s s u m e d for the cold-cathode ionisation gauge. I t h a s been stated previously t h a t no p u m p i n g effect could be observed w h e n the glass envelope of t h e gauge was operated at a t e m p e r a t u r e above 200°C, whilst the collector was r u n n i n g at a t e m p e r a t u r e of 280°C. I t can be a s s u m e d therefore t h a t the glass envelope is the actual sorbing surface, i 2 , the oil decomposition p r o d u c t s dissociate u p o n collision w i t h the hot filament and are sorbed b y the s u r r o u n d i n g cooler surfaces. The influence of the gauge t u b u l a t i o n on the pressure reading of the ins t r u m e n t is d e m o n s t r a t e d in a table. Sommaire : La sensibilit6 de la jauge ~ ionisation ~ cathode chaude a 6td etudi6e et les diffdrents aspects de son effet de p o m p a g e a u x tr~s basses pressions examin6s.

Article by L. Riddiford J. Sci. Instrum. 28, Dec. 1951 375-379

On the Application of a Philips Ionisation Gauge Type of Ion Source in a Mass Spectrometer Leak Detector

13/II

See _~:bstract No. : 4 1 / I I

O

Electronic Manometer Measures Minute Pressures United States. Tile m i c r o m a n o m e t e r referred to was constructed for use with a m a s s spectrometer and gives direct readings of pressure on a scale t h a t can be calibrated in units of pressure. ( B . S . I . t ~ . A . Bulletin) Sommaire : Description d ' u n m i c r o m a n o m 6 t r e destin~ "t ~tre employd avec le spectrom~tre de masse,

Knudsen Gauges United Kingdom.

Note by Anon. Math. Design 23, Aug. 1951 119

15/I1

A brief revieCv of the development and applications of the K n u d s e n gauge is followed b y a detailed description of i m p r o v e d forms of metal and glass gauges. Their performance w i t h respect to factors such as outgassing, m e t h o d s of suspension, extension of range b y electro-magnetic compensation, and d a m p i n g are discussed. The t h e o r y of the absolute m a n o m e t e r is reviewed. I n particular, t h e f u n d a m e n t a l a s s u m p t i o n s concerning a c c o m m o d a t i o n coefficient, the edge effect due to large heater-to-vane distance, a n d v a n e t e m p e r ature in t h e low pressure (Knudsen) region are discussed. A t h e o r y is developed to give a correction factor for a rectangular vane a n d h e a t e r valid for a n y dimensions and distance. I t is s h o w n t h a t u n d e r certain conditions calibration is independent of the t e m p e r a t u r e of the vane. Sommaire : Bref c o m p t e r e n d u sur le ddveloppement et les application~ de la jauge de Knudsen, suivi de la description ddtaill~e de formes amdliorSes de jauges m~talliques et en verre.

A New All-Glass Membrane Manometer United Kingdom. I n pressure m e a s u r e m e n t s involving substances which m i g h t a t t a c k m e r c u r y all-glass

O

14/II

m a n o m e t e r s are p a r t i c u l a r l y useful. The a u t h o r s refer in particular to m a n o m e t e r s of the d i a p h r a g m type, where the corrosive gas, the pressure of which is to be measured, is kept on one side of the d i a p h r a g m and a m e r c u r y m a n o m e t e r is connected to the s y s t e m on the other side of tim d m p h r a g m . Details are given of a n e w design developed b y the authors. The d i a p h r a g m of the n e w m a n o m e t e r is in contact with a vertical lever, which consists of a glass t u b e and contains a p l a t i n u m wire, suspended f r o m a glass spring. The zero position is checked b y electrical c o n t a c t with the p l a t i n u m wire. The d i a p h r a g m has a d i a m e t e r of a b o u t 2 cm. and is kept as t h i n as possible. This gauge has been used with success for the m e a s u r e m e n t of the v a p o u r pressures of stannic halides in t h e t e m p e r a t u r e range 20-340°C. Tile gauge facilitates readings with a precision of 0.1 m m . Hg. T h e variation of the zero setting is less irregular t h a n is the case with o t h e r gauges of this type. I t should be useful in all instances, where the measuring procedure requires successive heating and cooling of the gauge. S o m m a i r e : On donne les d~tails d ' u n m a n o m ~ t r e ~ m e m b r a n e enti~rement en verre employ6 avec succ6s p o u r le m e s u r a g e de la pression de v a p e u r des halog~nures s t a n n i q u e s en t e m p 6 r a t u r e s v a r i a n t de la t e m p 6 r a t u r e a t m o s p h 6 r i q u e j u s q u ' h e n v i r o n 340°C,

A Sensitive Differential Manometer Canada. A description is given of a differential m a n o m e t e r of small volume, developed b y the a u t h o r for a

Article by W. Steckelmacher Vacuum x, Oct. 1951 266-282 16/II

Note by A. Kabesh & R. S. Nyholm J. Chem. Soe. Nov, 19~1

3252-3253 17/II

special purpose. I t is capable of a precision of 0.1 to 0.2 micron Hg. The i n s t r u m e n t consists of two m e a s u r i n g cells each connected to nearly identical oscillator circuits and is of the d i a p h r a g m gauge type, where t h e d i a p h r a g m is one plate of a n electrical condenser. I n this case the m e r c u r y surface serves as t h e diaphragm. F o r m o s t m e a s u r e m e n t s t h e distance b e t w e e n condenser plate and m e r c u r y surface in each of the two cells was held a t 1.3 m m . B o t h m e a s u r i n g cells were m o u n t e d on a brass plate which in t u r n was bolted to a concrete base, r e s t i n g on shock absorbers. Vibration w a s n o t eliminated altogether, b u t reduced to a n a m o u n t which did n o t interfere w i t h the m e a s u r e m e n t s . Changes in t e m p e r a t u r e h a d some effect on t h e position of the m e r c u r y levels a n d h a d to be t a k e n into a c c o u n t w h e n o p e r a t i n g the i n s t r u m e n t . A wire sealed into t h e b o t t o m of t h e m a n o m e t e r connected t h e t o t a l m a s s of m e r c u r y to t h e g r o u n d a n d t h u s acted as a r e t u r n lead

J a n u a r y , 1952

vacuum Vol. I I No. I