Accepted Manuscript Title: Fabrication, characterization and cytotoxicity studies of ionically cross-linked docetaxel loaded chitosan nanoparticles Author: Ankit Jain Kanika Thakur Gajanand Sharma Preeti Kush Upendra K. Jain PII: DOI: Reference:
S0144-8617(15)00992-3 http://dx.doi.org/doi:10.1016/j.carbpol.2015.10.012 CARP 10429
To appear in: Received date: Revised date: Accepted date:
21-7-2015 1-10-2015 4-10-2015
Please cite this article as: Jain, A., Thakur, K., Sharma, G., Kush, P., and Jain, U. K.,Fabrication, characterization and cytotoxicity studies of ionically crosslinked docetaxel loaded chitosan nanoparticles, Carbohydrate Polymers (2015), http://dx.doi.org/10.1016/j.carbpol.2015.10.012 This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
*Highlights (for review)
Highlights Ionically cross-linked DTX-CH-NP prepared by Ionotropic gelation Influence of fabrication conditions on micromeritics investigated
ip t
Spherically shaped nanoparticles with an average size of 159.2-220.7 nm
cr
Nanoparticles released 78-82% of drug following Korsmeyer-Peppas kinetics
Ac ce p
te
d
M
an
us
An increase of 25% MDA-MB-231 cell line growth inhibition by nanoparticles
Page 1 of 32
*Manuscript
1 2
Fabrication, characterization and cytotoxicity studies of ionically cross-linked docetaxel loaded chitosan nanoparticles
3
Ankit Jain1, Kanika Thakur 2, Gajanand Sharma2, Preeti Kush1, Upendra K. Jain1 1
4
Department of Pharmaceutics, Chandigarh College of Pharmacy,
5 2
University Institute of Pharmaceutical Sciences, UGC Centre of Advanced Studies, Panjab University, Chandigarh, India 160014
ip t
6 7
Mohali-140110, India
cr
8
us
9 10
an
11 12
M
13 14
ed
15
ce pt
16 17 18 19
*Address for correspondence:
21
Ankit Jain
22
Department of Pharmaceutics
23
Chandigarh College of Pharmacy, Mohali-140110, India
24
E-mail address:
[email protected]
25
Tel: +91-09466831003
Ac
20
26 27 28 1 Page 2 of 32
Abstract
30
The present investigation aimed at the fabrication and characterization of ionically cross-
31
linked docetaxel (DTX) loaded chitosan nanoparticles (DTX-CH-NP) using ionic gelation
32
technique with sodium tripolyphosphate (TPP) as the cross-linking agent. The formulated
33
nanoparticles were characterized in terms of particle size, drug entrapment efficiency (EE),
34
scanning electron microscopy (SEM), in vitro release and cytotoxicity studies. Formulation
35
factors (chitosan, TPP and drug concentration) were examined systematically for their effects
36
on size of the nanoparticles. The average size of the nanoparticles was observed to be in the
37
range of 159.2 ± 3.31 to 220.7 ± 2.23 nm with 78-92% encapsulation efficiency (EE). The in
38
vitro cytotoxicity studies on breast cancer cell lines (MDA-MB-231) revealed the advantages
39
of DTX-CH-NP over pure DTX with approximately 85% cell viability reduction. The results
40
indicate that systematic modulation of the surface charge and particle size of ionically cross-
41
linked nanoparticles can be readily achieved with the right control of critical processing
42
parameters. Thus, DTX-CH-NP presents a promising delivery alternative for breast cancer
43
treatment.
44
Keywords: Chitosan, Docetaxel, Tripolyphosphate, Nanoparticles, Cross-linking
M
an
us
cr
ip t
29
ed
45
48 49 50 51 52
Ac
47
ce pt
46
53 54 55 56
2 Page 3 of 32
1. Introduction
58
Cancer is a growing menace, with the number of patients increasing at an alarming rate.
59
Chemotherapy as a treatment option has been successful, but to some extent in cancer
60
treatment. The main drawbacks of chemotherapy include the limited accessibility of drugs to
61
the tumor tissues, high toxicity, development of multiple drug resistance and non-specific
62
targeting (Parveen & Sahoo, 2008). Nanoparticles (NPs), an evolution of nanotechnology,
63
have demonstrated great potential in successfully addressing the problems related to
64
chemotherapeutic drug delivery by providing high drug payload, improvement in the
65
biodistribution of drugs and ability to target tumors with an enhanced accumulation (Naahidi
66
et al., 2008; Danhier, Feron & Preat, 2010; Bertrand et al., 2014; Ferrari, 2005).
67
In the recent decades, polymeric nanoparticles have witnessed an exceptional growth and
68
usage in anti-cancer drug delivery. The high surface-to-volume ratio of polymeric
69
nanoparticles improves the loading capacity of the selected molecule, while providing it
70
therequired protection (Rodrigues, Rosa da Costa & Grenha, 2012; Peer et al., 2007; Prabhu,
71
Patravale & Joshi, 2015). These particles also help in enhancement of the therapeutic efficacy
72
of anticancer drugs by regulating their release, improvement in stability and prolonged
73
circulation time. A number of studies have reported that nano-sized drug carriers composed
74
of natural and synthetic polymers sustain in the body for prolonged periods by evading the
75
reticulo-endothelial system (RES) (Hwang, Kim, Kwon & Kim, 2008). Polymeric
76
nanoparticles accumulate in the tumor tissue, resulting in a disorganized vascular
77
architecture, referred to as the enhanced permeability and retention (EPR) effect (Sultana,
78
Khan, Kumar, Kumar, & Ali, 2013; Garcia-Fuentes & Alonso, 2012).
cr
us
an
M
ed
ce pt
79
ip t
57
Chitosan-based polymeric nanoparticles have received great attention in the recent times due
81
to their biodegradability, biocompatibility, non-toxicity and low immunogenicity (Dash,
82
Chiellini, Ottenbrite & Chiellini, 2011). Chitosan, the N-deacetylated form of chitin, mostly
83
found in the exoskeleton of crustaceans, insects, and fungi, is a natural polysaccharide
84
(Muzzarelli, Stanic, Gobbi, Tosi & Muzzarelli, 2004; Dutta, Dutta & Tripathi, 2004). It has
85
been recognized as a promising polymer for drug delivery, possessing high density of
86
positive charge, attributed to the presence of glucosamine group on its backbone (Cooney,
87
Petermann, Lau & Minteer, 2009; Jee at al., 2012). Chitosan acts on tumor cells to interfere
88
with the cell metabolism by inhibiting cell growth or inducing cell apoptosis (Cao & Zhou,
89
2005). Previous studies have reported that low-molecular weight and modified chitosan could
90
inhibit tumor growth leading to good prospects for their application in cancer therapy (Maeda
Ac
80
3 Page 4 of 32
& Kimura, 2004). The strong mucoadhesive interactions of chitosan with the mucous
92
membranes associated with tumors, makes it capable for efficient anticancer drug delivery
93
(Zhou, Hong & Fang, 2007). Chitosan contains abundant amino and hydroxyl groups, thus
94
enabling nanoparticulate formulation via both physical and chemical cross-linking (Makhlof,
95
Tozuka & Takeuchi, 2011). Ionic cross-linking of chitosan with negatively charged
96
multivalent ions such as tripolyphosphate (TPP) is a typical non-covalent interaction (Tsai,
97
Chen, Bai & Chen, 2011). Under acidic conditions, the amino group of chitosan molecule
98
protonizes to –NH3+ which ultimately, interacts with an anion such as tripolyphosphate (TPP)
99
to form nanoparticles (Tsai, Bai & Chen, 2008). The reversible physical cross-linking by
100
electrostatic interaction is a very simple method and prevents possible toxicity of reagents
101
and other undesirable side effects (Ringel & Horwtiz, 1991).
102
Docetaxel (DTX), a second-generation semi-synthetic taxane derivative is effective against a
103
variety of solid tumors including breast, ovarian, prostate and non-small cell lung cancer
104
(Lyseng-Williamson & Fenton, 2005; Bissery, Nohynek, Sanderink & Lavelle, 1995). The
105
clinical applications of DTX are limited due to its poor aqueous solubility, rapid phagocytic
106
activity, renal clearance and non-selective distribution (Zhao et al., 2010). Since, DTX is
107
highly lipophilic and practically insoluble in water, the main marketed product of DTX
108
(Taxotere®) used clinically is formulated using Tween 80 (Zhang & Zhang, 2013). Tween 80
109
tends to alter the membrane fluidity, resulting in an increase of membrane permeability
110
associated with serious hypersensitivity reactions and cumulative-fluid retention (Dou,
111
Zhang, Liu, Zhang & Zhai, 2014). A number of drug delivery systems have been reported for
112
DTX such as micelles, liposomes, self-emulsified DTX formulations (Yang, Li, Wang, Dong
113
& Qi, 2014), PEGylated immunoliposomes (Zhao et al., 2009) and PEG-liposomes-folic acid
114
bioconjugates (Song et al., 2011), lipid emulsified nanoparticles (Zhang et al., 2015), folate
115
decorated human serum albumin nanoparticles (Jiang, Gong, Zhag & Zu, 2015),
116
hypersensitive and biodegradable nanoparticles (Wu et al., 2015; Liu et al., 2012), and
117
diblock copolymer nanoparticles (Tao et al., 2013) . All these delivery systems are limited by
118
the complicated preparative procedures, high cost and low stability of the formulations.
119
In the present study, ionically cross-linked docetaxel loaded chitosan nanoparticles (DTX-
120
CH-NP) were formulated by ionotropic gelation method. Chitosan was cross-linked with
121
tripolyphosphate (TPP) and the influence of a number of formulation parameters like chitosan
122
and TPP concentration, chitosan-TPP volume ratio, pH and temperature of chitosan solution
123
on the fabrication process were investigated systematically. The nanoparticles were
124
characterized in terms of particle size, zeta potential, polydispersity index, drug entrapment
Ac
ce pt
ed
M
an
us
cr
ip t
91
4 Page 5 of 32
125
efficiency (EE), loading capacity (LC), transmission electron microscopy (TEM), scanning
126
electron microscopy (SEM), in vitro release and cytotoxicity screening, stability studies and
127
drug release kinetics.
128
2. MATERIALS AND METHODS
130
2.1. Materials
131
Docetaxel was purchased from Sigma-Aldrich (USA). Chitosan (degree of deacetylation-
132
80%, molecular weight 40-80 kDa) was procured from Himedia Pvt. Ltd (Mumbai, India).
133
Sodium Tripolyphosphate (TPP) and glacial acetic acid were procured from Loba chemie
134
Pvt. Ltd (Mumbai, India). All other chemicals and reagents used in the study were of
135
analytical grade.
136
2.2. Preparation of ionically cross-linked Docetaxel loaded Chitosan nanoparticles (DTX-
137
CH-NP)
138
Blank ionically cross-linked chitosan nanoparticles were prepared by the ionic gelation of
139
chitosan with TPP anions as described by Calvo et al. (Calvo, Remu˜nán-López, Vila-Jato &
140
Alonso, 1997; Vila et al., 2004). Briefly, chitosan was dissolved in 1% acetic acid solution
141
(0.2-1%, w/v) at room temperature under sonication. The pH of the resulting solution was
142
adjusted to 3-6 using 20% w/v sodium hydroxide solution and passed through a syringe filter
143
(pore size 0.45 μm, Millipore, USA) to remove insoluble particles. Sodium TPP was
144
dissolved in double distilled water at a concentration of (0.25-1.25% w/v) and also passed
145
through a syringe filter (pore size 0.22 μm, Millipore, USA). Blank nanoparticles were
146
prepared upon the dropwise addition of TPP solution (0.25-1.25%, w/v) to chitosan solution,
147
kept under stirring at room temperature. Fig. 1 depicts the procedure for the preparation of
148
DTX-CH-NP by ionotropic gelation method. For the preparation of DTX-CH-NP, various
149
concentrations of DTX (0.2, 0.4, 0.6, 0.8 and 1 mg/ml) in TPP solution (firstly drug was
150
dissolved in 1ml of methanol) were prepared. Nanoparticles were formed by adding this
151
solution dropwise into chitosan solution. The nanoparticle suspension was continuously
152
stirred for 1 h and centrifuged at 16,000 rpm for 30 min. (Cooling centrifuge C-24BL, Remi
153
Instruments, Mumbai, India). The pellet obtained was further redispersed in 10 ml of
154
Phosphate buffer saline (pH 7.4). Mannitol (2%, w/v) was added as a cryoprotectant and
155
freezed at −80ºC for 4 h followed by lyophilization in laboratory model freeze dryer (Alpha
156
2–4 LD Plus, Martin Christ, Germany) for 24 h at −48ºC and 0.0010 mbar.
Ac
ce pt
ed
M
an
us
cr
ip t
129
5 Page 6 of 32
2.3. Characterization of ionically cross-linked Docetaxel loaded Chitosan nanoparticles
158
(DTX-CH-NP)
159
2.3.1. Micromeritics and zeta potential
160
The mean particle size, size distribution and zeta potential of DTX-CH-NP was analyzed by
161
photon correlation spectroscopy using the Zetasizer Nano ZS (Malvern Instruments, Malvern,
162
UK). All the measurements were carried out in triplicates at 25ºC. The nanoparticle
163
suspension was diluted ten times with deionized water and the analysis was performed at a
164
scattering angle of 90º.
165
2.3.2. Entrapment efficiency and loading capacity
166
The entrapment efficiency (%) of docetaxel in DTX-CH-NP was determined by separating
167
DTX containing supernatant from nanoparticles by centrifugation at 15000 rpm for 40 min.
168
(C-24BL, Remi Instruments, Mumbai, India). The clear supernatant was analyzed for the
169
contents of docetaxel by measuring the absorbance in a UV-Visible spectrophotometer
170
(Shimadzu UV spectrophotometer, Japan) at 230 nm. All the samples were measured in
171
triplicates. The percentage entrapment efficiency and loading capacity were calculated as
172
follows:
174
cr
us
an
M
×100………………………….. (1)
EE (%) LC (%)
ed
173
ip t
157
×100…………… (2)
Where DTXt is the total amount of docetaxel used in the preparation of DTX-CH-NP and
176
DTXf is the free docetaxel present in the supernatant.
177
2.3.3. Morphological characterization of nanoparticles
178
The shape and surface morphology of DTX-CH-NP was determined by scanning electron
179
microscopy (Jeol, JSM-6100, Japan). The lyophilized samples were mounted on an
180
aluminium stub using a double adhesive carbon tape. The photomicrographs were recorded at
181
an accelerating voltage of 10kV at different magnifications.
182
2.3.4. Transmission electron microscopy (TEM)
183
The topography of nanoparticles was determined using transmission electron microscopy
184
(JEOL, JEM-1230, Japan Ltd.). The samples were negatively stained with freshly prepared
185
phosphotungstic acid solution (2%, pH 6.8).
186
2.3.5. Fourier transform infrared spectroscopy (FT-IR)
Ac
ce pt
175
6 Page 7 of 32
DTX-CH-NP samples were subjected to FT-IR spectroscopy in a Fourier-transform infrared
188
spectrophotometer (IR Affinity, Shimadzu, Japan) in the range of 4000–500 cm-1. The freeze-
189
dried nanoparticles were mixed with KBr and pressed to a pellet to investigate the chemical
190
interactions between the drug and polymer matrix.
191
2.3.6. In vitro drug release
192
The in vitro release of docetaxel from the various batches of DTX-CH-NP was carried out by
193
dialysis sac method. An accurately weighed quantity of about 20 mg of nanoparticles was
194
suspended in 3.0 ml of release medium (Phosphate buffer saline solution, pH 7.4) in the
195
dialysis tubing (cut off 10,000 kDa). The dialysis tube was tied to the paddle of USP type II
196
dissolution apparatus (TDL–08L, Electrolab, India) and immersed in 250 ml of dissolution
197
medium (Phosphate buffer, pH 7.4). The dissolution media was maintained at 37ºC ± 0.5ºC
198
with continuous stirring at 50 rpm. An aliquot of 5 ml sample was withdrawn at various time
199
intervals and replenished with equal volumes of fresh media. The content of DTX in the
200
samples was determined spectrophotometrically by measuring the absorbance at 230 nm in a
201
UV-Visible Spectrophotometer (Shimadzu UV spectrophotometer, Japan).
202
2.3.7. In vitro Cytotoxicity Screening
203
MTT assay using breast cancer cell lines (MDA-MB-231) was employed to determine the
204
cell viability. The cell lines were seeded in 96-well plates at the density of 150,000 viable
205
cells per well and incubated for 24 hours to allow cell attachment at 37ºC in 5% CO2
206
humidified incubator (Sanna et al., 2011). The cells were then incubated for another 24 hours
207
with blank nanoparticles (NP), ionically cross-linked docetaxel loaded chitosan nanoparticles
208
(DTX-CH-NP) and the pure drug (DTX) at 0.05, 0.5, 5.0 μg/ml equivalent concentrations for
209
24, 48 and 72 h, respectively. These concentrations correspond to plasma levels of the drug
210
which can be achieved in humans (Fonseca, Simoes & Gaspar, 2002). The medium was
211
removed, at specific time intervals and the wells were washed twice with phosphate buffer
212
solution and 10 μL of 3-(4, 5-dimethyl-thiazol-2-yl)-2, 5-diphenyltetrazolium bromide
213
(MTT) solution was added to each well of the plate and incubated for another 1 to 4 h.
214
Following media removal, the MTT-formazan formed by metabolically viable cells was
215
dissolved in 200 μL of Diemthyl sulphoxide (DMSO) and after 4 h, the plates were observed
216
at 560 nm in a microplate reader. % Cell viability was calculated by the following equation:
217
Ac
ce pt
ed
M
an
us
cr
ip t
187
Cell viability (%)
×100…………… (3)
7 Page 8 of 32
Where Abs sample is the absorbance of the solution incubated with the ionically cross linked
219
nanoparticles
220
Abs control is the absorbance of the solution incubated with the culture medium only
221
(positive control).
222
2.3.8. Stability studies
223
DTX-CH-NP were evaluated for the change in particle size and entrapment efficiency i.e.
224
aggregation over the period of 3 months. All the formulations were kept at a temperature of
225
4°C for a period of 3 months.
226
2.3.9. Statistical analysis
227
The results were presented as mean ± standard deviation. Statistical analysis was performed
228
with one-way ANOVA and statistical significance was designated as p < 0.05.
229
3. Results and discussion
230
3.1. Particle size, size distribution and zeta potential of nanoparticles
231
Based on an optimization procedure designed, the effect of formulation parameters (chitosan,
232
TPP and drug concentration, chitosan to TPP volume ratio, temperature and pH of chitosan
233
solution) was investigated systematically by changing one parameter while keeping the others
234
constant. On the basis of preliminary trials, the parameters were varied as follows:
235
concentration of chitosan (0.2–1%, w/v), concentration of TPP (0.25–1.25%, w/v), chitosan-
236
TPP volume ratio (3:1-7:1), stirring speed (800-1600 rpm), temperature (35ºC - 65ºC) and pH
237
(3.5-6) of chitosan solution, respectively. The effect of each of these parameters is discussed
238
as follows:
239
3.1.1. Effect of TPP (cross-linker) concentration
240
TPP has five negative charge groups that interact with the positive amino groups of chitosan
241
in acetic acid solution (Hosseinzadeh, Atyabi, Dinarvand & Ostad, 2012).The concentration
242
of chitosan was fixed at (0.2%, w/v) and TPP concentration was varied from (0.25–1.25%,
243
w/v). Fig. 2(a) represents a comparative effect of TPP concentration on particle size,
244
polydispersity index and zeta potential. It was observed that the initial increase in TPP
245
concentration (0.75%, w/v) led to a significant reduction in particle size. A high TPP
246
concentration resulted in high degree of cross-linking of chitosan molecules, thus compact
247
particle structures were formed. Further, increase in TPP concentration beyond (0.75%, w/v)
Ac
ce pt
ed
M
an
us
cr
ip t
218
8 Page 9 of 32
led to a significant enhancement in the particle size. The increase in the number of anionic
249
groups led to an increase in the electrostatic interaction with positive amino sites on chitosan
250
molecule, thereby leading to reduction of the surface charge and increase in particle size. Zeta
251
potential is an important parameter which influences the stability of the nanoparticles through
252
electrostatic repulsion (Gang & Wang, 2007; Ajun, Yan, Li & Huili, 2009). The positive zeta
253
potential is attributed to the presence of amino groups and further, neutralization of charged
254
amino groups led to a decrease in the overall zeta potential. TPP concentration higher than
255
(1.25%, w/v) formed aggregated solution, giving a gel-like consistency. The concentration of
256
TPP had little effect on the polydispersity of particles since the polydispersity index (PDI)
257
value was below 0.5 indicating uniformity of particle size.
258
3.1.2. Effect of chitosan concentration
259
Chitosan has the property of protonization under acidic conditions due to which it undergoes
260
cross-linking with anions like Tripolyphosphate. TPP concentration was fixed at (0.75%,
261
w/v) and chitosan concentration was varied from (0.2-1%, w/v). Fig. 2(b) represents a
262
comparative effect of chitosan concentration on particle size, polydispersity index and zeta
263
potential. The increase in size and zeta potential of the nanoparticles with increase in chitosan
264
concentration from (0.2-1 mg/ml) may be attributed to the linear increase in viscosity of
265
chitosan solution with increasing concentration. The high viscosity prevents effective ionic
266
interaction between TPP and chitosan solution (Berger et al., 2004). The electrostatic
267
repulsions and interchain hydrogen bonding interactions between chitosan molecules remain
268
in equilibrium upto the concentration of 2 mg/ml leading to the formation of large particle
269
sizes (Gana, Wang, Cochrane & McCarron, 2005).The zeta potential of the nanoparticles
270
increased linearly due to a more protonized –NH3+ ion on the surface of nanoparticles formed
271
with higher chitosan concentration. The PDI of the nanoparticles was found to be favorable
272
i.e. below 0.5.
273
3.1.3. Effect of chitosan-TPP volume ratio
274
The effect of chitosan-TPP volume ratio on the particle size, polydispersity index and zeta
275
potential was very significant. TPP concentration was fixed at (0.75%, w/v) and chitosan
276
concentration was fixed at (0.2%, w/v). Fig. 2(c) represents a comparative effect of chitosan-
277
TPP volume ratio on particle size, polydispersity index and zeta potential. The results
278
indicate that, with increasing chitosan volume (3:1 to 5:1) in the solution, the particle size
279
decreased from 295.3 nm to 159.4 nm and then increased to 502.1 nm at ratio 7:1. When
280
chitosan-TPP volume ratio was below 3:1, the volume of chitosan solution was not sufficient
Ac
ce pt
ed
M
an
us
cr
ip t
248
9 Page 10 of 32
for the formation of a cross-linked structure with TPP. With an increase in volume ratio from
282
3:1 to 5:1, the particle size decreased due to increased cross-linking density between chitosan
283
and TPP. As its volume ratio increased from 5:1 to 7:1, though the molecules were cross-
284
linked, the excess of chitosan resulted in the formation of larger-sized nanoparticles. The zeta
285
potential of chitosan–TPP nanoparticles showed a linear relationship to chitosan-TPP volume
286
ratio from 3:1 to 5:1. The PDI values were all below 0.5 and least value of PDI (0.267) was
287
seen at 5:1 volume ratio of chitosan-TPP.
288
3.1.4. Effect of temperature of chitosan solution
289
Fig. 2(d) shows the comparative effect of temperature of chitosan solution on the particle
290
size, polydispersity index and zeta potential. The particle size decreased from 489.4 nm to
291
160.1 nm with increase in temperature of the chitosan solution (35 ºC-65ºC) due to decrease
292
in intrinsic viscosity. The increase in temperature reduced the water of hydration of chitosan
293
molecules, resulting in an increase in chitosan chain flexibility (Chen & Tsaih, 1998). As a
294
result, chitosan molecules approached each other with greater force resulting in the formation
295
of compactly cross-linked nanoparticles. The decrease in particle size is negligible at a
296
temperature above 65ºC. A decrease in zeta potential was also observed and the resulting PDI
297
values were all below 0.5.
298
3.1.5. Effect of pH of chitosan solution
299
Chitosan is a weak base polyelectrolyte insoluble at neutral and alkaline pH (Mi, Sung &
300
Shyu, 2003).The amine groups are positively charged in an acidic medium and hence, the
301
surface charge density of chitosan molecules depends on the solution pH (Leong, Mao &
302
Truong-Le, 1998; Ko, Park & Hwang, 2002). As the ionic cross-linking process for the
303
formation of chitosan–TPP nanoparticles is pH-dependent, the effect of changing pH of
304
chitosan solution on particle size, zeta potential and polydispersity index was investigated
305
keeping the concentration of chitosan (0.2%, w/v), TPP (0.75%, w/v) and chitosan-TPP
306
volume ratio (5:1) fixed. Fig.2 (e) represents a comparative effect of pH of chitosan solution
307
on particle size, polydispersity index and zeta potential.
308
At a low pH (3.5), the amino groups of chitosan and TPP molecule are protonated, leading to
309
a lower charge density of the molecules. This causes an insufficient cross-linking and hence
310
larger size of the particles. With an increase in pH, the deprotonation degree of TPP
311
increases, while the protonation degree of chitosan is less affected. Hence, the particle size
312
decreases significantly at pH 5.5. The sharp increase in size at pH 6.0 indicates that the
Ac
ce pt
ed
M
an
us
cr
ip t
281
10 Page 11 of 32
degree of protonization at surface of the particles was reduced leading to particle aggregation.
314
The same decreasing pattern was also shown in zeta potential at pH 5.5 and increase at pH 6.
315
3.1.6. Effect of the stirring speed
316
Fig. 2(f) represents a comparative effect of stirring speed on particle size, polydispersity
317
index and zeta potential. The results indicate that the particle size was significantly reduced
318
by increasing stirring speed from 800 rpm to 1400 rpm. There was slight decrease in zeta
319
potential and no significant effect on PDI was observed.
320
3.1.7. Effect of the drug concentration
321
DTX-CH-NPs were prepared by the addition of DTX in 0.75% w/v TPP into 0.2% w/v of
322
chitosan solution. Fig. 2(g) represents a comparative effect of drug concentration on particle
323
size, polydispersity index and zeta potential. The results indicate that the addition of DTX led
324
to an increase in the size of chitosan nanoparticles. In general, the size of DTX-CH-NP did
325
not grow significantly at concentration up to 0.6 mg/ml, but there was a change in size when
326
the concentration of the drug was increased from 0.6 to 1 mg/ml. The drug concentration did
327
not influence the zeta potential of the prepared nanoparticles significantly.
328
Table 1 depicts the effect of different concentrations of DTX on the %EE and %LC of DTX-
329
CH-NP. A maximum EE (78%) was achieved at 0.6 mg/ml of DTX concentration. Initially,
330
%EE showed an increase with increase in DTX concentration up to 0.6 mg/ml. From 0.6- 1
331
mg/ml, the %EE decreased from 78% to 73%. The %LC of DTX-CH-NP was in the range of
332
9-12%. A high loading capacity was obtained due to the hydrophobicity of DTX. The %LC
333
increased as a function of initial DTX content. The increase in %LC as a function of increase
334
in drug content corresponds to the previous literature reports such as loading of bovine serum
335
albumin (Jiang, Gong, Zhag & Zu, 2015) and ammonium glycyrrhizinate (Wu et al., 2005)
336
into chitosan–TPP nanoparticles. The results showed that 0.6 mg DTX in the formulation
337
resulted in the best % EE and %LC. Further increasing the DTX amount did not significantly
338
affect %LC.
339
3.2. Morphological characterization of nanoparticles
340
The morphological characteristics of DTX-CH-NP were imaged using SEM and TEM. Fig.
341
3(a-b) displays the scanning electron micrographs of DTX-CH-NP showing their surface
342
morphology while Fig. 3(c) depicts the transmission electron micrograph. The nanoparticles
343
showed a dense and spherical structure with uniformity in size.
344
3.3. Fourier Transform infrared spectroscopy (FT-IR)
Ac
ce pt
ed
M
an
us
cr
ip t
313
11 Page 12 of 32
FT-IR spectroscopy was used to study the drug–polymer interactions. Fig. 4 shows the FT-IR
346
spectra of DTX, DTX-Chitosan physical mixture (50:50), DTX-TPP physical mixture (50:50)
347
and DTX-CH-NP. The spectra of DTX shows characteristic peaks at 3481.84 cm-1 which may
348
be ascribed to N-H stretching of alkanes. Peaks at 1740 cm-1 and 1711 cm-1 may be due to C-
349
O stretching and at 1631.97 cm-1 can be due to N-H plane bending. The spectra of DTX-
350
Chitosan and DTX-TPP indicated the absence of any drug-excipient interaction between the
351
drug and polymer as the spectra of the drug remained intact without any changes in peaks.
352
The peak at 1651 cm-1 of DTX-chitosan spectra disappeared in the spectra of DTX-CH-NP
353
and two new peaks at 1643 cm-1 and 1543 cm-1 appeared. The disappearance of the peak
354
could be attributed to the linkage between the phosphoric and ammonium ions. The cross-
355
linked chitosan nanoparticles showed a peak for P = O at 1157 cm-1. All recorded spectra
356
show that the peaks of docetaxel remain unaffected indicating that the drug remained intact
357
during the preparation procedure of nanoparticles. Thus, FT-IR analysis indicated absence of
358
any drug excipient interaction between the drug and polymer during the formulation of
359
nanoparticles.
360
3.5. In vitro drug release
361
The cumulative percent drug release of DTX from different formulations of DTX-CH-NP
362
varied from 77.46 ± 1.17% and 73.79 ± 0.79% respectively over a period of 24 h as shown in
363
Fig. 5. The release profiles of the nanoparticles are similar, and exhibit an initial burst release
364
followed by a slow and sustained release due to the release of drug from the matrix. The
365
initial rapid release was mainly due to the drug present at the surface of the nanoparticles
366
which diffuses in the release medium in the initial time. To determine the release kinetics,
367
the release data was fitted into various kinetic models. Table 2 represents the release kinetics
368
of various batches of ionically cross-linked docetaxel loaded chitosan nanoparticles and the
369
co-efficient of correlation (R2) of zero order, first order, Korsmeyer–Peppas model and
370
Higuchi’s square root model was determined. Korsmeyer–Peppas model was observed to be
371
the best fit model indicating Fickian diffusion as the mechanism of drug release from
372
nanoparticles. Further, the value of ‘n’ the release exponent of Korsmeyer–Peppas (0.45≤ n ≤
373
0.89) indicates that nanoparticles released the drug by combination of both diffusion of drug
374
through the polymer and dissolution of the polymer (Costa & Lobo, 2001; Siepmann &
375
Peppas, 2001; Higuchi, 1963).
376
3.6. In vitro Cytotoxicity Screening
an
us
cr
ip t
345
Ac
ce pt
ed
M
.
12 Page 13 of 32
The in vitro cytotoxicity screening of docetaxel as a free drug and ionically cross-linked
378
docetaxel loaded chitosan nanoparticles was determined by MTT assay, which is a
379
colorimetric test based on the selective ability of viable cells to reduce the tetrazolium
380
component of MTT into purple colored formazan crystals. MTT assay was performed for the
381
three different concentrations i.e., 0.05, 0.5 and 5.0 μg/ml using MDA-MB-231 as a model
382
breast cancer cell line.
383
Untreated MDA-MB-231 cells as well as cells treated with blank cross-linked chitosan
384
nanoparticles, with the same polymer content were used as control. Fig.6 (a-c) shows the
385
viability of MDA-MB-231 cancer cells, cultured with blank cross-linked chitosan
386
nanoparticles (Blank-NPs) and ionically cross-linked docetaxel loaded chitosan nanoparticles
387
[DTX-CH-NP3] after incubation for 24 h (a), 48 h (b) and 72 h (c), in comparison with that
388
of pure drug [DTX]. The biocompatibility of chitosan was confirmed by the negligible
389
toxicity of blank chitosan nanoparticles [NPs]. After 24 h incubation, as depicted in Fig. 6(a),
390
the cell viability decreased to about 59.22, 47.12 and 38.45% for DTX-CH-NP3 at 0.05, 0.5
391
and 5.0 μg/ml drug concentrations respectively, corresponding to an increase in cytotoxicity
392
of 25% compared with that of free drug. After 48 h incubation, portrayed in Fig. 6(b), the
393
cytotoxicity increased to about 41.34, 35.12 and 25.31% for the DTX-CH-NP3 and 65.88,
394
58.98 and 48.87% for the free drug, respectively. The more marked inhibition of cell growth
395
was obtained for longer incubation period (72 h). The strongest cytotoxic effect was achieved
396
with nanoparticles at 5.0 μg/ml drug concentration.
397
The storage stability of chitosan nanoparticles cross-linked with TPP is an important
398
parameter. Particles in the colloidal dispersion may adhere to one another and form
399
aggregates of increasing size. The physical stability was investigated at 4ºC over a period of 3
400
months. A special emphasis was placed on the changes in particle size and entrapment
401
efficiency which are the two important physicochemical parameters of nanoparticles. The
402
nanoparticles were found to be stable with no major changes except a slight increase in
403
particle size and a slight decrease in entrapment efficiency and drug loading.
404
4. Conclusion
405
The present work is an effort to explore ionically cross-linked docetaxel loaded chitosan
406
nanoparticles for breast cancer treatment in order to improve the therapeutic efficacy and
407
minimize severe toxicity associated with the clinical usage of docetaxel. TPP was
408
successfully employed as a cross-linking agent to formulate nanoparticles by ionotropic
409
gelation. The influence of a number of fabrication parameters was systematically investigated
Ac
ce pt
ed
M
an
us
cr
ip t
377
13 Page 14 of 32
and the concentrations of TPP, chitosan, chitosan-TPP volume ratio were found to have a
411
profound impact on the physicochemical characteristics of nanoparticles. The nanoparticles
412
exhibited particle size in the range of 159.2 ± 3.31 nm to 220.7 ± 223 nm with a sustained
413
drug release pattern. The in vitro cytotoxicity screening studies demonstrated a 25% increase
414
in cytotoxicity compared with the free drug against MDA-MB-231 cancer cell lines. Thus,
415
the present study unraveled the effect of fabrication parameters on the ionic cross-linking
416
process. The results of this investigation clearly demonstrate that the ionically cross-linked
417
docetaxel loaded nanoparticles seems to have a great potential as a drug carrier in cancer
418
chemotherapy. The present research work offers immense scope for further exploitation of
419
chitosan in future for the development of nanoparticulate drug delivery system for cancer
420
chemotherapy.
421
Acknowledgements
422
The authors are grateful to Central Instrumentation Laboratory, Panjab University,
423
Chandigarh for particle size and SEM analysis and also gratified to the Management of
424
Chandigarh College of Pharmacy, Mohali (Punjab), India for financial support and providing
425
the facilities to carry out the research work.
426
Reference
427 428 429
Ajun,W., Yan, S., Li, G., & Huili, L. (2009). Preparation of aspirin and probucol in combination loaded chitosan nanoparticles and in vitro release study. Carbohydrate Polymers 75(4), 566–574.
430 431 432
Berger, J., Reist, M., Mayer, J.M., Felt, O., Peppas, N.A., & Gurny, R. (2004). Structure and interactions in covalently and ionically crosslinked chitosan hydrogels for biomedical applications. European J ournal of Pharmaceutics & Biopharmaceutics, 57, 19–34.
433 434 435
Bertrand, N., Wu, J., Xu, Xi., Kamaly, N., & Farokhzad, O.C. (2014). Cancer nanotechnology: The impact of passive and active targeting in the era of modern cancer biology. Advanced Drug Delivery Reviews, 66, 2-25.
436 437 438
Bissery, M.C., Nohynek, G.,Sanderink, G.J., & Lavelle, F. (1995). Docetaxel (Taxotere): a review of preclinical and clinical experience. Part I: Preclinical experience. Anti-cancer Drugs, 6(3), 339–355.
439 440 441
Calvo, P.,Remu˜nán-López, C., Vila-Jato, J.L., & Alonso, M.J. (1997). Novel hydrophilic chitosan-polyethylene oxide nanoparticles as protein carriers. Journal of Applied Polymer Science, 63, 125–132.
442 443
Cao, J., & Zhou, N.J. (2005). Progress in antitumor studies of chitosan. Chinese Journal of Biochemical Pharmaceutics, 26(2), 127.
Ac
ce pt
ed
M
an
us
cr
ip t
410
14 Page 15 of 32
Chen, R.H., & Tsaih, M.L. (1998).Effect of temperature on the intrinsic viscosity and conformation of chitosans in dilute HCl solution. International Journal of Biological Macromolecules, 23, 135–141.
447 448 449
Cooney, M.J., Petermann, J., Lau, C., & Minteer, S. (2009). Characterization and evaluation of hydrophobically modified chitosan scaffolds: Towards design of enzyme immobilized flow-through electrodes. Carbohydrate Polymers, 75, 428–435.
450 451
Costa, P., & Lobo, J.M.S. (2001). Modeling and comparison of dissolution profiles. Journal of Pharmaceutical Sciences, 13, 123–133.
452 453 454
Danhier,F., Feron, O., & Preat, V. J. (2010). To exploit the tumor microenvironment: Passive and active tumor targeting of nanocarriers for anti-cancer drug delivery. Journal of Controlled Release, 148, 135–146.
455 456
Dash, M., Chiellini, F., Ottenbrite, R.M., & Chiellini, E. (2011). Chitosan— A versatile semisynthetic polymer in biomedical applications. Progress in Polymer Science, 36, 981– 1014.
457 458 459
Dou, J., Zhang, H., Liu, X., Zhang, M., & Zhai, G.(2014). Preparation and evaluation in vitro and in vivo of docetaxel loaded mixed micelles for oral administration. Colloids and Surfaces B: Biointerfaces, 114, 20– 27.
460 461
Dutta, P.K., Dutta, J. & Tripathi, V.S. (2004). Chitin and chitosan: Chemistry, properties and applications. Journal of Scientific & Industrial Research, 63, 20-31.
462 463
Ferrari, M. (2005). Cancer nanotechnology: opportunities and challenges. Nature Reviews Cancer, 5, 161-171.
464 465 466
Fonseca, C., Simoes, S., & Gaspar, R. (2002). Paclitaxel-loaded PLGA nanoparticles: preparation, physicochemical characterization and in vitro anti-tumoral activity. Journal of Controlled Release, 83, 273–286.
467 468 469
Gana, Q.,Wang, T., Cochrane, C., & McCarron, P. (2005). Modulation of surface charge, particle size and morphological properties of chitosan-TPP nanoparticles intended for gene delivery. Colloids and Surfaces B: Biointerfaces, 44, 65–73.
470 471 472
Gang, Q., & Wang, T.(2007). Chitosan nanoparticle as protein delivery carrier--systematic examination of fabrication conditions for efficient loading and release. Colloids and Surfaces B: Biointerfaces, 59(1), 24–34.
473 474
Garcia-Fuentes, M., & Alonso, M.J. (2012). Chitosan-based drug nanocarriers: where do we stand? Journal of Controlled Release, 161, 496–504.
475 476 477
Higuchi, T. (1963). Mechanism of sustained-action medication. Theoretical analysis of rate of release of solid drugs dispersed in solid matrices. Journal of Pharmaceutical Sciences, 52, 1145–1149.
478 479 480
Hosseinzadeh,H., Atyabi, F., Dinarvand, R., & Ostad, S.N. (2012).Chitosan–Pluronic nanoparticles as oral delivery of anticancer gemcitabine: preparation and in vitro study. International Journal of Nanomedicine, 7, 1851–1863.
Ac
ce pt
ed
M
an
us
cr
ip t
444 445 446
15 Page 16 of 32
Hwang, H., Kim, I., Kwon, I.C., & Kim, Y. (2008).Tumor targetability and antitumor effect of docetaxel-loaded hydrophobically modified glycol chitosan nanoparticles. Journal of Controlled Release, 128, 23–31.
484 485
Janes, K.A.,Calvo, P., & Alonso, M.J. (2001). Polysaccharide colloidal particles as delivery systems for macromolecules. Advanced Drug Delievery Reviews, 47, 83–97.
486 487 488
Jee, J., Na, J.H., Lee, S., Kim, S.H., Choi, K., Yeo, Y., & Kwon, I.C. (2012). Cancer targeting strategies in nanomedicine: Design and application of chitosan nanoparticles. Current Opinion in Solid State & Materials Science, 16(6), 333–342.
489 490 491
Jiang, S., Gong, X., Zhag, X., & Zu, Y. (2015). Preparation, characterization, and antitumor activities of folate-decorated docetaxel-loaded human serum albumin nanoparticles. Drug Delivery, 22(2), 206-213.
492 493 494
Ko, J.A., Park, H.J., & Hwang, S.J. (2002). Preparation and characterization of chitosan microparticles intended for controlled drug delivery. International Journal of Pharmaceutics, 249, 165–174.
495 496
Leong, K.W., Mao, H.Q., & Truong-Le, V.L. (1998). DNA-polycation nanospheres as nonviral gene delivery vehicles. Journal of Controlled Release, 53, 183–193.
497 498 499
Liu, Q., Li, R., Zhu, Z., Qian., X., Guan, W., Yu., L., Yang, M., Jiang, X., & Liu, B. (2012). Enhanced antitumor efficacy, biodistribution and penetration of docetaxel-loaded biodegradable nanoparticles. International Journal of Pharmaceutics, 439(1-2), 350-358.
500 501
Lyseng-Williamson, K.A., & Fenton, C. (2005). Docetaxel: a review of its use in metastatic breast cancer. Drugs, 65(17), 2513–2531.
502 503 504
Maeda, Y., & Kimura, Y. (2004). Antitumor Effects of Various Low-Molecular-Weight chitosans Are Due to Increased Natural Killer Activity of Intestinal Intraepithelial Lymphocytes in Sarcoma 180–Bearing Mice. Journal of Nutrition, 134(4), 945–950.
505 506 507
Makhlof, A., Tozuka, Y., & Takeuchi, H. (2011). Design and evaluation of novel pHsensitive chitosan nanoparticles for oral insulin delivery. European Journal of Pharmaceutical Sciences, 42, 445–451.
508 509
Mi, F.L., Sung, H.W., & Shyu, S.S. (2003). Synthesis and characterization of biodegradable TPP/ genipin co-crosslnked chitosan gel beads. Polymer, 44, 6521–6530.
510 511 512
Muzzarelli, C., Stanic, V., Gobbi, L., Tosi, G., & Muzzarelli, R.A.A. (2004). Spray-drying of solutions containing chitosan together with polyuronans and characterisation of the microspheres. Carbohydrate Polymers, 57, 73–82.
513 514 515
Naahidi, S., Jafari, M., Edalat, F., Raymond, K., Khademhosseini, A., & Chen, P. (2013) Biocompatibility of engineered nanoparticles for drug delivery. Journal of Controlled Release, 166, 182–194.
516 517
Parveen, S., & Sahoo, S. K. (2008). Polymeric nanoparticles for cancer therapy. Journal of Drug Targeting, 16(2), 108–123.
Ac
ce pt
ed
M
an
us
cr
ip t
481 482 483
16 Page 17 of 32
Peer, D., Karp, J.M., Hong, S., Farokhzad, O.C., Margalit, R., & Langer, R. (2007). Nanocarriers as an emerging platform for cancer therapy. Nature Nanotechnology, 2, 751 – 760.
521 522
Prabhu, R.H., Patravale, V., & Joshi, M.D. (2015). Polymeric nanoparticles for targeted treatment in oncology: current insights. International Journal of Nanomedicine, 5, 161-171.
523 524
Ringel, I., & Horwtiz, S.B. (1991). Studies with RP 56976 (taxotere): a semisynthetic analogue of taxol. Journal of the National Cancer Institute, 83, 288-291.
525 526 527
Rodrigues, S., Rosa da Costa, A.M., & Grenha, A. (2012). Chitosan/carrageenan nanoparticles: effect of cross-linking with tripolyphosphate and charge ratios. Carbohydrate Polymers, 89, 282–289.
528 529 530 531 532
Sanna, V., Roggio, A.M., Posadino, A.M., Cossu, A., Marceddu, S., Mariani, A., Alzari, V., Uzzau, S., Pintus, G., & Sechi, M. (2011). Novel docetaxel-loaded nanoparticles based on poly(lactide-co-caprolactone) and poly(lactide-co-glycolide-co-caprolactone) for prostate cancer treatment: formulation, characterization, and cytotoxicity studies. Nanoscale Research Letters, 6(1),260.
533 534 535
Siepmann, J., & Peppas, N.A. (2001). Modeling of drug release from delivery systems based on hydroxypropyl methylcellulose (HPMC). Advanced Drug Delivery Reviews, 48, 139– 157.
536 537 538 539
Song, H., Geng, H., Ruan, J., Wang, K., Bao, C., Wang, J., Peng, X., Zhang, X., & Cui, D.(2011).Development of Polysorbate 80/Phospholipid mixed micellar formation for docetaxel and assessment of its in vivo distribution in animal models. Nanoscale Research Letters, 6, 354.
540 541 542
Sultana, S., Khan, M.R., Kumar, M., Kumar, S., & Ali, M. (2013). Nanoparticles-mediated drug delivery approaches for cancer targeting: a review. Journal of Drug Targeting, 21(2), 107–125.
543 544 545
Tao, W., Zeng, X., Liu, T., Wang, Z., Xiong, Q., Ouyang, C., Huang, L., & Mei, L. (2013). Docetaxel-loaded nanoparticles based on star-shaped mannitol-core PLGA-TPGS diblock copolymer for breast cancer therapy. Acta Biomterialia, 9(11), 8910-8920.
546 547 548
Tsai, M.L., Bai, S.W., & Chen, R.H. (2008). Cavitation effects versus 395 stretch effects resulted in different size and polydispersity of ionotropic gelation chitosan–sodium tripolyphosphate nanoparticle. Carbohydrate Polymers, 71, 448–457.
549 550 551
Tsai, M.L., Chen, R.H., Bai, S.W., & Chen, W.Y. (2011).The storage stability of chitosan/tripolyphosphate nanoparticles in a phosphate buffer. Carbohydrate Polymers, 84, 756–761.
552 553 554
Vila, A., Sanchez, A., Janes, K., Behrens, I., Kissel, T., Jato, J.L., & Alonso, M.J.(2004). Low molecular weight chitosan nanoparticles as new carriers for nasal vaccine delivery in mice. European Journal of Pharmaceutics & Biopharmaceutics, 57, 123–131.
555 556
Wu, J., Zhao, L., Xu, X., Bertrand, N., Choi, W., Yameen, B., Shi, J., Shah, V., Mulvate, M., Maclean, J.L., & Farokhzad, O.C. (2015). Hydrophobic Cysteine Poly (disulfide)-based
Ac
ce pt
ed
M
an
us
cr
ip t
518 519 520
17 Page 18 of 32
Redox-Hypersensitive Nanoparticle Platform for Cancer Theranostics. Angewandte Chemie International Edition, 54 (32), 9218-9223.
559 560 561
Wu, Y., Yang, W., Wang, C., Hu, J., & Fu, S. (2005). Chitosan nanoparticles as a novel delivery system for ammonium glycyrrhizinate. International Journal of Pharmaceutics, 295(1-2), 235-245.
562 563 564
Yang, Z., Li, J., Wang, Z., Dong, D., & Qi, X.(2014). Tumor-targeting dual peptidesmodified cationic liposomes for delivery of siRNA and docetaxel to gliomas. Biomaterials, 35, 5226-5239.
565 566 567
Zhang, F., Chang, M., Yu, Y., Zhang, Y., Liu, G., Wei, T., Zuo, T., Guan, Y., Lin, G., & Zhao, Z. (2015). Preparation and evaluation of lipid emulsified docetaxel-loaded nanoparticles. Journal of Pharmacy and Pharmacology. DOI: 10.1111/jphp.12472
568 569
Zhang, L., & Zhang, N. (2013). How nanotechnology can enhance docetaxel therapy. International Journal of Nanomedicine, 8, 2927–2941.
570 571 572 573
Zhao, L., Wei, Y., Zhong, X., Liang, Y., Zhang, X., Li, W., Li, Bi., Wang, Y., & Yu, Y. (2009).PK and tissue distribution of docetaxel in rabbits after i.v. administration of liposomal and injectable formulations. Journal of Pharmaceutical and Biomedical Analysis, 49, 989– 996.
574 575 576
Zhao, M., Su, M., Lin, X., Luo, Y., He, H., Cai, Cu., & Tang, X. (2010). Evaluation of docetaxel-loaded intravenous lipid emulsion: pharmacokinetics, tissue distribution, antitumor activity, safety and toxicity. Pharmaceutical Research, 27, 1687–1702.
577 578 579
Zhou, S.H., Hong, Y., & Fang, G.J. (2007). Preparation, characterization and anticancer effect of chitosan nanoparticles. Journal of Clinical Rehabilitative Tissue Engineering Research, 11 (48), 9688– 9691.
Ac
ce pt
ed
M
an
us
cr
ip t
557 558
18 Page 19 of 32
Table(s)
List of Tables Table 1 Characterization of ionically cross-linked docetaxel loaded chitosan nanoparticles by varying drug concentration
Ac ce p
te
d
M
an
us
cr
ip t
Table 2 Release kinetics and stability data of different formulations of ionically cross-linked docetaxel loaded chitosan nanoparticles
Page 20 of 32
Characterization of ionically cross-linked docetaxel loaded chitosan nanoparticles by varying drug concentration Zeta potential (mV)
Blank
˗˗˗
159.2 ± 3.31
0.278 ± 0.029
33.2 ± 1.66
DTX-CH-NP1
0.2
163.2 ± 3.43
0.259 ± 0.034
32.7 ± 1.12
DTX-CH-NP2
0.4
170.9 ± 4.58
0.247 ± 0.041
31.9 ± 2.11
DTX-CH-NP3
0.6
175.2 ± 3.43
0.229 ± 0.027
DTX-CH-NP4
0.8
204.1 ± 6.09
0.287 ± 0.043
DTX-CH-NP5
1
220.7± 2.23
0.345± 0.036
Entrapment Efficiency (%)
Loading Capacity (%)
˗˗˗
˗˗˗
69.37 ± 0.74
9.94 ± 0.81
cr
(nm)
Polydispersity Index (PDI)
75.11 ± 1.02
11.26 ± 0.79
32.3 ± 1.67
78.28 ± 0.91
12.01 ± 0.92
29.8 ± 1.96
70.41 ± 1.35
10.56 ± 0.99
73.23± 1.42
10.21± 0.65
us
Particle size
an
DTX concentration (mg/ml)
Formulation code
ip t
Table 1:
34.8± 3.40
Ac ce p
te
d
M
Mean ± S.D., n =3. Note: DTX concentration: Concentration of Docetaxel.
Page 21 of 32
Table 2: Release kinetics and stability data of different formulations of ionically cross-linked docetaxel loaded chitosan nanoparticles Release kinetics
Zero order
First order
Higuchi’s square- root
Korsmeyer-Peppas
ip t
Formulation Code
-1
k
R2
-1
(% h )
R2
(h )
k (%h
0.6452
0.0479
0.7859
0.0009
0.8946
DTX-CH-NP2
0.6277
0.0519
0.7767
0.0011
0.8849
DTX-CH-NP3
0.6962
0.0557
0.8639
0.0013
0.9254
DTX-CH-NP4
0.6206
0.0436
0.7862
0.0009
0.8779
DTX-CH-NP5
0.7025
0.0407
0.8342
0.0006
R2 )
2.1451
M
0.9188
k
(%h-n)
0.9439
n
0.2348
0.5880
2.3431
0.9210
0.2948
0.5781
2.4480
0.9114
0.3268
0.5982
2.2568
0.9598
0.3932
0.5437
1.9710
0.9475
0.2785
an
DTX-CH-NP1
-0.5
cr
k
us
R2
0.5165
Stability Data
Entrapment Efficiency (%)
d
4±2ºC
1 month
2 months
3 months
78.28 ± 0.91
77.4 ± 0.3
76.5 ± 1.8
76.0 ± 3.0
167.2 ± 3.43
169.6 ± 4.3
176.5± 3.2
181.5 ± 3.3
Ac ce p
Size (nm)
Initial
te
Ionically cross-linked Docetaxel loaded chitosan nanoparticles
Page 22 of 32
Figure(s)
Figure captions Fig. 1 Preparation of ionically cross-linked docetaxel loaded chitosan nanoparticles by Ionotropic gelation.
cr
ip t
Fig. 2 Bar graph showing comparative effect of (a) TPP concentration (b) Chitosan concentration (c) Chitosan: TPP volume ratio (d) Temperature of chitosan solution (e) pH of chitosan solution (f) Stirring speed (g) Drug concentration on particle size, polydispersity index and zeta potential of ionically cross-linked docetaxel loaded chitosan nanoparticles.
us
Fig. 3 Scanning electron micrographs showing shape and surface morphology (a-b) and transmission electron micrograph (c) of ionically cross-linked docetaxel loaded chitosan nanoparticles.
an
Fig. 4 Comparative FT-IR spectra of docetaxel, docetaxel-chitosan physical mixture, docetaxelTPP physical mixture and ionically cross-linked docetaxel loaded chitosan nanoparticles.
M
Fig. 5 Release profile of docetaxel from various formulations of ionically cross-linked docetaxel loaded chitosan nanoparticles.
Ac ce p
te
d
Fig. 6 % Cell viability of MDA-MB-231 cancer cells after incubation for 24 h (a), 48 h (b) and 72 h (c) with ionically cross-linked docetaxel loaded chitosan nanoparticles.
Page 23 of 32
ip t cr us an
Ac ce p
te
d
M
Fig. 1
Fig. 2(a)
Page 24 of 32
ip t cr us an
Ac ce p
te
d
M
Fig. 2(b)
Fig. 2(c)
Page 25 of 32
ip t cr us an
Ac ce p
te
d
M
Fig. 2(d)
Fig. 2(e)
Page 26 of 32
ip t cr us an M
Ac ce p
te
d
Fig. 2(f)
Fig. 2(g)
Page 27 of 32
ip t cr us an
Ac ce p
te
d
M
Fig. 3(a)
Fig. 3(b)
Page 28 of 32
ip t cr us an M d te Ac ce p
Fig. 3(c)
Page 29 of 32
ip t cr us an M d te Ac ce p Fig. 4
Page 30 of 32
ip t cr us an M Ac ce p
te
d
Fig. 5
Fig. 6(a)
Page 31 of 32
ip t cr us an
Ac ce p
te
d
M
Fig. 6(b)
Fig. 6(c)
Page 32 of 32