A 3D-printed local drug delivery patch for pancreatic cancer growth suppression Hee-Gyeong Yi, Yeong-Jin Choi, Kyung Shin Kang, Jung Min Hong, Ruby Gupta Pati, In Kyong Shim, Chan Mi Lee, Song Cheol Kim, Dong-Woo Cho PII: DOI: Reference:
S0168-3659(16)30380-7 doi: 10.1016/j.jconrel.2016.06.015 COREL 8324
To appear in:
Journal of Controlled Release
Received date: Revised date: Accepted date:
11 November 2015 16 April 2016 8 June 2016
Please cite this article as: Hee-Gyeong Yi, Yeong-Jin Choi, Kyung Shin Kang, Jung Min Hong, Ruby Gupta Pati, In Kyong Shim, Chan Mi Lee, Song Cheol Kim, Dong-Woo Cho, A 3D-printed local drug delivery patch for pancreatic cancer growth suppression, Journal of Controlled Release (2016), doi: 10.1016/j.jconrel.2016.06.015
This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
ACCEPTED MANUSCRIPT A 3D-printed local drug delivery patch for pancreatic cancer growth suppression
T
Hee-Gyeong Yi1†, Yeong-Jin Choi2†, Kyung Shin Kang3, Jung Min Hong3, Ruby Gupta Pati1,
Department of Mechanical Engineering, Pohang University of Science and Technology
SC R
1
IP
In Kyong Shim4, Chan Mi Lee4, Song Cheol Kim5*, and Dong-Woo Cho1*
(POSTECH), Pohang, Kyungbuk, Korea 2
Division of Integrative Biosciences and Biotechnology, POSTECH, Pohang, Kyungbuk,
3
NU
Korea
Department of Anatomy & Cell Biology, Indiana University School of Medicine,
MA
Indianapolis, Indiana, USA 4
Asan Institute for Life Science, Seoul, Korea
5
Department of Surgery, University of Ulsan College of Medicine & Asan Medical Center,
These authors contributed equally to this work.
*Co-correspondences to:
TE
†
D
Seoul, Korea
CE P
Song Cheol Kim, M. D. - Ph. D., Department of Surgery, University of Ulsan College of Medicine & Asan Medical Center, 388-1 Pungnap-2 Dong, Songpa-gu, Seoul 05505, Korea. Telephone: +82-2-3010-3936; Fax: +82-2-474-9027; E-mail:
[email protected]
AC
Dong-Woo Cho, Ph. D., Department of Mechanical Engineering and Center for Rapid Prototyping-based 3D Tissue/Organ Printing, POSTECH, 77 Cheongam-ro, Nam-gu, Pohang, Kyungbuk 37673, Korea. Telephone: +82-54-279-2171; Fax: +82-54-279-5419; E-mail:
[email protected]
1
ACCEPTED MANUSCRIPT Abstract Since recurrence and metastasis of pancreatic cancer has a worse prognosis, chemotherapy
IP
T
has been typically performed to attack the remained malignant cells after resection. However,
SC R
it is difficult to achieve the therapeutic concentration at the tumor site with systemic chemotherapy. Numerous local drug delivery systems have been studied to overcome the shortcomings of systemic delivery. However, because most systems involve dissolution of the
NU
drug within the carrier, the concentration of the drug is limited to the saturation solubility, and consequently cannot reach the sufficient drug dose. Therefore, we hypothesized that 3D
MA
printing of a biodegradable patch incorporated with a high drug concentration would provide a versatile shape to be administered at the exact tumor site as well as an appropriate
D
therapeutic drug concentration with a controlled release. Here, we introduce the 3D-printed
TE
patches composed of a blend of poly(lactide-co-glycolide), polycaprolactone, and 5-
CE P
fluorouracil for delivering the anti-cancer drug in a prolonged controlled manner and therapeutic dose. 3D printing technology can manipulate the geometry of the patch and the drug release kinetics. The patches were flexible, and released the drug over four weeks, and
AC
thereby suppressed growth of the subcutaneous pancreatic cancer xenografts in mice with minimized side effects. Our approach reveals that 3D printing of bioabsorbable implants containing anti-cancer drugs could be a powerful method for an effective local delivery of chemotherapeutic agents to treatment of cancers.
2
ACCEPTED MANUSCRIPT
NU
SC R
IP
T
Graphical abstract
Keywords
MA
3D printing; Local drug delivery; Biodegradable patch; Pancreatic cancer
Chemical compounds
CE P
Abbreviations
TE
D
5-Fluorouracil (PubChem CID: 3385); Poly(lactide-co-glycolide) (PubChem CID: 23111554); Polycaprolactone (PubChem CID: 10401); Rhodamine B (PubChem CID: 6694)
AC
5-FU, 5-flurouracil; PLGA, poly(lactide-co-glycolide); PCL, polycaprolactone; MHDS, multi-head deposition system; SEM, scanning electron microscope; FT-IR, Fourier transform infrared spectroscopy; PBS, phosphate buffered saline; DMSO, dimethyl sulfoxide; MTS, 5(3-carboxymethoxyphenyl)-2-(4,5-dimethylthiazoly)-3-(4-sulfophenyl)tetrazolium, inner salt; IC50, inhibitory concentration 50; hASC, human adipose stem cell; H&E, hematoxylin and eosin; i.v., intravenous; s.d., standard deviation; S:V, surface area to volume
3
ACCEPTED MANUSCRIPT 1.
Introduction
Pancreatic cancer is a highly aggressive disease because of its tendency for early local
IP
T
spreading and metastasis. Chemotherapy is often used after resection of the cancer to prevent
SC R
recurrent growth and metastasis of remaining malignant cells. Nevertheless, a low survival rate in the range, in the range of 8–25%, has been reported following extended surgery [1, 2]. Since most chemotherapeutic drugs, such as 5-flurouracil (5-FU), paclitaxel, and cisplatin,
NU
have poor aqueous solubility, conventional administration techniques (e.g., intravenous injection, oral administration) cannot easily deliver a therapeutic concentration of the drugs
MA
at the tumor site. In addition, anti-cancer agents may accumulate in crucial organs (e.g., heart, liver, lung) and cause severe side effects [3, 4]. Therefore, various local drug delivery
TE
D
systems have been developed to overcome the shortcomings of conventional chemotherapy. The major objectives of local drug delivery systems are to enhance drug dosage, to
CE P
improve overall quality of life, and to minimize systemic side effects. Injectable or implantable systems display spatiotemporal controllability and prolonged release kinetics. A
AC
biodegradable triblock copolymer poly(lactide-co-glycolide) (PLGA)-polyethylene glycolpoly(lactide-co-glycolide) was developed as an injectable hydrogel containing the dissolved paclitaxel; it exhibited a fairly long release period (6 weeks) [5]. A poly(ester-carbonate)collagen composite film releasing hydroxycamptothecin was found to be flexible and could be fixed onto tissue; it also prevented the new growth of lung cancer [6]. However, chemical dissolution of drugs into delivery systems is limited by the saturation solubility of the drug in the carrying material [7]. Conversely, if the drug is physically dispersed as a powder inside the carrying material, the final concentration can be above the saturation solubility. 4
ACCEPTED MANUSCRIPT Intratumoral injection of PLGA microspheres containing a high content of 5-fluorouracil (5FU) crystalline powder significantly decreased mortality in glioma-bearing rats [8]. Blending
T
of 5-FU or paclitaxel powder into ethylene-vinyl acetate film demonstrated the effective local
SC R
IP
exposure at a high drug concentration for a long-term release period [9].
Currently, three-dimensional (3D) printing technology is driving major innovations in the biomedical field, including drug delivery. 3D-printed drug-incorporating constructs can be
NU
designed and fabricated with precisely defined architecture and dose. 3D printing allows the drug to be released from a construct in a controlled manner by manipulating the geometry of
MA
the construct. Among the various kinds of 3D printing systems, the extrusion-based method provides flexibility in selection of drugs and polymers, wide range of concentration of the
D
incorporated drugs, solvent-free continuous dispensing of the drug-containing material, and
TE
uniform distribution of the drug [10]. The antibiotic-loaded polycaprolactone (PCL)
CE P
constructs fabricated using the extrusion-based printing techniques proved that the drug delivery systems could be produced to have high loading efficiency and good stability of the incorporated drug, even if the drug was subjected to high temperatures during the
AC
manufacturing process [11, 12]. We hypothesize that a 3D-printed biodegradable patch containing a high concentration of chemotherapeutic drug could be easily applied to the exact tumor site and reduce the cancer growth. For this study, we blended PLGA and PCL (PLGA/PCL), loaded with different amounts of 5-FU into the blend, and printed PLGA/PCL/5-FU patches. We assessed whether the 3D printing process is suitable for producing a highly concentrated drug delivery system. The printed patches were evaluated in vitro to identify their characteristics including mechanical 5
ACCEPTED MANUSCRIPT properties, release kinetics, and therapeutic feasibility. We then analyzed the therapeutic efficacy and systemic toxicity by applying the patches to a mouse model of pancreatic cancer.
T
We demonstrate that the 3D-printed PLGA/PCL patches can deliver 5-FU for more than four
Materials and methods
NU
2.
SC R
IP
weeks and thereby suppress the cancer growth, with reduced side effects.
2.1. 3D printing of PLGA/PCL/5-FU patches
MA
5-FU and PLGA (lactide:glycolide = 85:15) were purchased from Sigma-Aldrich (St. Louis, MO, USA) and PCL was purchased from Polysciences, Inc. (Warrington, PA, USA). 5-FU
D
crystalline powder was comminuted using a mortar and a pestle, and then sieved through a
TE
100-μm nylon mesh to ensure extrusion through a nozzle with a 250-μm inner diameter.
CE P
After melting the PCL and PLGA granules together at a ratio of 1:1 and 140 °C for 5 min on a glass dish, the 5-FU powder was then manually mixed into the molten polymers at 140 °C
AC
for 5 min using a thin rod (Fig. 1A). The PLGA/PCL/5-FU paste was loaded in the printing head of in-house extrusion-based 3D printer called a multi-head deposition system (MHDS) [13]. The MHDS is composed of a nozzle-connected printing head (metal syringe and heating block), pneumatic pressure controller, and three-axis (X, Y, Z Cartesian coordinates) linear motion controllers. The PLGA/PCL/5-FU was pneumatically extruded from the reservoir at 600 kPa and 140 °C and deposited on the stage along the designed path at room temperature (Fig. 1B). PLGA/PCL patches were loaded with no drug, 10 mg, 50 mg, 100 mg, and 150 mg of 5-FU 6
ACCEPTED MANUSCRIPT per gram of total weight (P0, P10, P50, P100, and P150, respectively). We fabricated various P150 patches with different pore shapes and total thicknesses to evaluate the effects of patch
T
geometry on the release profile. While the layers were stacked, we altered the orientation of
IP
the lines in each layer to generate various pore shapes (Fig. 1C). The angles between the lines
SC R
of subsequent layers were designed as follows: 90° between the lower and upper layers to generate a latticed pattern; 90° between the lower and sandwich layers, and 60° between the
NU
sandwich and upper layers to generate a slant pattern; and 60° between the lower and upper layers to generate a triangular pattern. The lattice-type patches with 2, 4, and 8 layers (2L, 4L,
MA
and 8L, respectively) were fabricated to increase the total thickness of the patches. For use in in vitro and in vivo experiments, the circular lattice patch was selected to demonstrate
D
feasibility. We expected that the lattice pattern has a low Young’s modulus compared to the
TE
other patterns, as demonstrated in our previous study [14]. The circular shape was designed
CE P
to cover the rounded shape of the solid tumor in the in vivo experiment. The latticed pattern was designed to have the same width gap and strut, so the vertical and horizontal lengths of
AC
the pore were equal.
7
CE P
TE
D
MA
NU
SC R
IP
T
ACCEPTED MANUSCRIPT
Fig. 1. 3D printing of 5-FU-loaded patch. (A) Process of blending PLGA, PCL, and 5-FU. (B) Schematic drawing describing the system apparatus of MHDS, an extrusion-based 3D printer.
AC
(C) CAD of three types of pores latticed, slant, and triangular types.
2.2. Analysis of physical characteristics of 3D-printed patches We used a scanning electron microscope (SEM; Hitachi SU-6600, Hitachi, Tokyo, Japan) to observe the surface morphologies of the 3D-printed patches. The samples were platinumcoated by a sputter-coater and imaged using an accelerating voltage of 15 kV. A tensile test was performed to identify the tensile properties of the printed patches. Test 8
ACCEPTED MANUSCRIPT specimens were prepared following ISO 527-1 standards. Rectangular specimens (10 mm × 50 mm × 0.2 mm) with latticed pores were fabricated. We prepared the specimens made of
T
only PLGA, only PCL, PLGA/PCL, and PLGA/PCL/5-FU (150 mg/g of specimen) for
IP
comparative study. A single-column Instron 3340 mechanical testing system (Instron,
SC R
Norwood, MA, USA) was utilized. The specimens were gripped 10 mm from each end and
NU
stretched at a strain rate of 0.027 s-1 (Fig. S1).
MA
2.3. Analysis of chemical characteristics of 3D-printed patches The practical amount of 5-FU in the patches was determined. A weighted patch was
D
dissolved in a mixture of 1 ml of dichloromethane and 5 ml of distilled water. The polymeric
TE
part and 5-FU were dissolved in the dichloromethane and the water, respectively [15, 16]. The emulsion was centrifuged to separate the phases. The concentration of 5-FU dissolved in
CE P
the water of the upper phase was determined by measuring the absorbance at a wavelength of 265 nm using a UV-Vis spectrophotometer (Agilent 8453, Agilent Technologies, Palo Alto,
AC
CA, USA). We assessed the quality of 5-FU in the printed patches by conducting Fourier transform infrared spectroscopy (FT-IR). Potassium bromide discs containing 0.5 % w/w of pure 5-FU, small pieces of PLGA, PCL, and the 3D-printed PLGA/PCL/5-FU patch were prepared separately. The sample spectra were obtained using an FT-IR spectrometer (IFS-55, Bruker, Billerica, MA, USA).
9
ACCEPTED MANUSCRIPT 2.4. 5-FU release, swelling, and degradation study The release kinetics were obtained by soaking the printed patches in 1 ml of phosphate-
IP
T
buffered saline (PBS) at 37 °C [11, 17]. All released media were harvested and replaced with
SC R
fresh PBS at regular intervals during the release periods. The concentration of 5-FU in the release media was determined by measuring the absorbance at λ = 265 nm using the UV-Vis spectrophotometer. We observed the swelling and degradation of the patches to determine the
NU
mechanism of 5-FU release. After accurately determining the initial weight (WI), the patches were separately incubated in 5 ml of PBS at 37 °C. We harvested three samples, immediately
D
MA
measured the swollen weight (WS), and then calculated the degree of swelling as follows:
TE
For the degradation study, the incubated samples were collected for 4 months. The samples were freeze-dried, then the dry weights (WD) were measured. To quantify the degradation of
AC
CE P
patches, we calculated the residual weight as follows:
2.5. Evaluations of chemosensitivity and therapeutic effects in vitro MIA PaCa-2 (ATCC, Manassas, VA, USA), a human pancreatic cell line, was used to determine chemosensitivity to 5-FU as previously described [17]. The cells were cultured in Dulbecco’s modified Eagle’s medium (DMEM, Hyclone, Logan, UT, USA) supplemented with 10%v/v fetal bovine serum (Hyclone), 100 U/ml penicillin, and 100 μg/ml streptomycin (Gibco BRL, Grand Island, NY, USA) at 37 °C in 5% CO2 in a humidified incubator. The 10
ACCEPTED MANUSCRIPT culture medium was refreshed every 2 to 3 days. After harvesting cells, 2 × 10 4 cells were plated on each well of a 24-well culture plate and incubated for 24 h prior to drug treatment
T
(n = 5). The cells were then exposed to various concentrations of 5-FU from 10-2 μg/ml to
IP
102 μg/ml for 24 h. The 5-FU was serially diluted in dimethyl sulfoxide (DMSO) and added
SC R
to the culture medium at a ratio of 1:100. As a control, the same volume of drug-free DMSO was dissolved in the culture medium. After treatment, the medium was gently aspirated, and
NU
the cells were washed with fresh DMEM and incubated in drug-free culture medium for 72 h. We determined relative cell viability by performing 5-(3-carboxymethoxyphenyl)-2-(4,5-
MA
dimethylthiazoly)-3-(4-sulfophenyl)tetrazolium, inner salt (MTS) assay using a commercial MTS solution (CellTiter 96® Aqueous One Solution Cell Proliferation Assay, Promega,
D
Madison, WI, USA), then calculated the median inhibitory concentration (IC50).
TE
We then evaluated the cytotoxic effect of the printed PLGA/PCL/5-FU patches on
CE P
malignant and non-malignant cells. As a model of non-malignant cells, we selected human adipose-derived stem cells (hASCs). In order to allow the concentration of the released 5-FU from P10 patch in culture media to be above the IC50-value for 24 h, the required volume of
AC
the media was calculated based on the release profile and set to 200 μl. P0, P10, P50, P100, and P150 patches were each immersed in the 200 μl of culture media, in which MIA PaCa-2 cells or adipose stem cells had been plated, separately (n = 5 per group).
2.6. Generation of pancreatic cancer model and implantation of the 3D-printed patches To assess the therapeutic effect of the 3D-printed PLGA/PCL/5-FU patches in vivo, we implanted the patches to the bottom of subcutaneously grafted pancreatic cancers in athymic 11
ACCEPTED MANUSCRIPT mice. The animal study was performed according to the protocol approved by the Animal Care and Use Committee of POSTECH (2014-01-0002). After 1 week to allow the mice to
T
acclimatize to housing conditions, 1 × 107 MIA PaCa-2 cells in 100 μl of PBS were
IP
inoculated subcutaneously into the right flank region of 6-week-old male BALB/C nude
SC R
mouse. After 3 days to allow formation of a tumor mass (average size = 266.5 ± 58.0 mm3), mice were implanted with P100 and P150 patches (n = 10 per group). The mice that received
NU
no treatment or were implanted with the P0 patch were also prepared for the comparison (n = 10 per group). We anesthetized mice by intraperitoneal injection of 250 mg/kg 2,2,2-
MA
tribromoethanol (Sigma-Aldrich), made an incision near the inoculation site, inserted the patch right under the solid tumor, and immobilized the patch by suturing. All surgical
TE
D
procedures were performed in a specific-pathogen free room.
CE P
2.7 Evaluations of therapeutic effects in vivo To estimate the tumor growth, we measured length (l, mm) and width (w, mm) 2 to 3 days
AC
using calipers, then calculated the tumor size as follows:
The tumors were excised at 1 week and 4 weeks, fixed with 10% formalin, embedded in paraffin, and then sectioned. Tissue sections were stained with hematoxylin and eosin (H&E) to observe the cell morphology. Immunofluorescence staining was performed to examine proliferation of human pancreatic cancer cells in the tumor. We applied rabbit polyclonal Ki67 anti-body (Abcam, Cambridge, MA, USA, 1:100) and mouse monoclonal human lamin antibody (h-lamin, Abcam, 1:100) overnight at 4 °C. The samples were then incubated with 12
ACCEPTED MANUSCRIPT secondary antibodies including anti-rabbit IgG conjugated with FITC (Molecular Probes, Eugene, OR, USA, 1:200) or anti-mouse IgG conjugated with TRITC (Molecular Probes,
T
1:200), and DAPI for 1 h at 37 °C. Images were obtained using a Fluo View 1000 confocal
SC R
IP
microscope (Olympus, Melville, NY, USA) at constant camera settings.
NU
2.8 Evaluations of systemic toxicity
To visualize the drug release in vivo, we incorporated rhodamine B (Sigma), a well-known
MA
optical-imaging agent [18], instead of 5-FU, into the PLGA/PCL patches during the 3Dprinting process. The rhodamine B-loaded patches were also prepared with the same dosages:
D
100 and 150 mg per g of the patch (denoted as P100’ and P150’, respectively). The mice
TE
received the implantation of P100’ and P150’ patches (n = 10 per group). After 1 and 4 weeks later, whole-body imaging was performed using the IVIS Kinetic Imaging System (Caliper
CE P
Life Sciences, Hopkinton, MA, USA). The images were obtained with the excitation and emission wavelengths of 570 and 620 nm, respectively. After observing the external part of
AC
the whole-body, the internal part was examined by dissection. For the comparison, mice were intravenously (i.v.) injected with rhodamine B through the tail vein at a concentration of 60 mg/ kg of mice weight, and observed under the same imaging settings for 6 days. Blood analysis was conducted to compare the systemic toxicity between the 5-FU injection (60 mg/ kg of mice weight, once in every week; [19, 20]) and the implantation of P100 and P150 patches. Plasma was isolated from heparinized blood samples at 0, 1, and 4 weeks after the implantation. 5-FU concentrations were measured using reverse-phase high-performance liquid chromatography with MS/MS detection (RHPLC-MS) by Korea Basic Science 13
ACCEPTED MANUSCRIPT Institute (Daegu, Korea). To assess the liver and kidney functions, glutamic oxaloacetic transaminase (GOT) and blood urea nitrogen (BUN) were determined according to the
T
routine procedure by Korea Research Institute of Bioscience and Biotechnology (Cheongwon,
SC R
IP
Chungbuk, Korea).
NU
2.9 Statistical Analysis
We presented the data from the several experiments as means ± standard deviation (s.d.).
MA
When we compared more than two groups, we performed analysis of variance (ANOVA) for the statistical comparison. If the F-value in the ANOVA test rejected the null hypothesis, we
Results
CE P
3.
TE
D
conducted Bonferroni post-hoc test. Differences were regarded as significant at P < 0.05.
3.1. Physical characteristics of 3D-printed PLGA/PCL/5-FU patches
AC
To demonstrate the versatility of the 3D-printing method, we fabricated the patches in square form without loops (20 mm × 20 mm), and circular and oval forms with a loop on each side (8 mm in diameter for circular form, 8 mm in major length and 4 mm in minor length for oval form) to allow suturing (Fig. 2A). The 3D-printer also fabricated the various pore shapes with lattice, slant, and triangular patterns; the latticed patches were layered 2, 4, and 8 times (Fig. 2B, C). Thus, 3D-printing technology enables a drug delivery system with the diverse designs having the exact shape and size of the target region.
14
CE P
TE
D
MA
NU
SC R
IP
T
ACCEPTED MANUSCRIPT
Fig. 2. 3D-printed P150 patches with various structures. (A) Three shapes of the patches:
AC
square without loops; circle and oval shapes with loops on each side for suturing. Scale bar: 5 mm. (B) Three types of pores: latticed, slanted, and triangular. (C) Lattice patches layered 2, 4, and 8 times (denoted as 2, 4, and 8L, respectively) Scale bar: 2 mm. (D) SEM images of surface of P0, P10, P50, P100, and P150 patches. Scale bar: 500 μm. (E) Stress-strain curves and (F) tensile moduli of PLGA, PCL, PCL/PLGA with or without 5-FU. *: P < 0.05 difference versus PLGA/PCL/5-FU (G) Photographs presenting the flexible and stretchable properties of P150 lattice patch. Scale bar: 2 mm
15
ACCEPTED MANUSCRIPT Incorporation of 5-FU in the PLGA/PCL blended polymer influenced the surface morphology of the printed patch. The surface of the printed patches became rougher with the
T
increase of the 5-FU content (Fig. 2D). The flexibility of the printed patches was also
IP
affected by incorporating 5-FU into PLGA/PCL blend. While PLGA showed brittle behavior,
SC R
the stress-strain curve of the PLGA/PCL showed a much smaller slope, indicating increased flexibility (Fig. 2E). The PLGA/PCL incorporated 5-FU showed a slightly bigger slope than
NU
that of PLGA/PCL without drug. Nevertheless, the tensile modulus of PLGA was significantly highest than those of PCL, PLGA/PCL, or PLGA/PCL/5-FU (Fig. 2F). Thus,
MA
the ductility of PCL greatly contributed to increase flexibility of the 5-FU incorporated patch. As shown in Fig. 2G, the P150 patch is flexible and stretchable. Thus, it is suitable for
TE
D
covering a curved surface of soft tissue.
CE P
3.2. Chemical characteristics of 3D-printed PLGA/PCL/5-FU patches The theoretical amount of 5-FU in each patch was calculated from the concentration of 5-
AC
FU loaded and weight of patch. We then compared the theoretical amounts with the measured practical amounts. The average ratio of the practical amount of 5-FU to the theoretical amount of 5-FU (P/T ratio) was 101.2% (s.d. = 1.1) (Table 1). Thus, the process of blending 5-FU in PLGA/PCL and printing patches exhibited almost ideal efficiency for loading 5-FU in patches in the tested range, from 10 mg/g to 150 mg/g. The effect of the fabrication process on 5-FU should be examined because the blended material is subjected to temperatures up to 140 °C during the printing. FT-IR spectra of PLGA and PCL exhibit both absorption bands of the -C-H and C=O functional groups 16
ACCEPTED MANUSCRIPT (PLGA: 1996 cm-1 and 1733 cm-1; PCL: 3042 cm-1 and 1736 cm-1) (Fig. 3). The spectrum of 5-FU shows the absorption band of the N-H functional group (3424 cm-1). The spectrum of
T
the printed PLGA/PCL/5-FU patch shows all absorption bands of N-H, -C-H, and C=O
IP
functional groups (3426 cm-1, 3068 cm-1, 1722 cm-1, respectively). The data indicate that the
SC R
loaded and printed 5-FU was not damaged by the temperature.
NU
Table 1. Mean ± s.d. (n = 4) theoretical and practical amounts of 5-FU in each patch. Practical [μg]
P/T ratio [%]
44.8 ± 3.1
49.1 ± 1.5
105.4 ± 3.8
155.0 ± 7.1
158.0 ± 3.1
100.0 ± 3.3
295.1 ± 3.5
98.4 ± 1.2
637.4 ± 15.2
101.2 ± 2.4
WI [mg]
Theoretical [μg]
P10
4.5 ± 0.3
P50
3.1 ± 0.1
P100
3.1 ± 0.2
P150
4.3 ± 0.1
D
MA
Patch
TE
310.0 ± 17.3 640.0 ± 17.3
CE P
Theoretical: weight proportion 5-FU × WI; Practical: measured amount of 5-FU; P/T:
AC
Practical/theoretical.
17
SC R
IP
T
ACCEPTED MANUSCRIPT
NU
Fig. 3. Infrared spectra of pure PLGA, pure PCL, pure 5-FU, and the printed PCL/PLGA /5-
MA
FU patch.
D
3.3. 5-FU release, swelling, and degradation study
TE
The various structures of P150 patches influenced the 5-FU release during the observation
CE P
period (6 days). When the pore types were different, both slanted and triangular patches released much lower levels of 5-FU compared to the lattice patch (Fig. 4A). Besides, the increased total thicknesses of 4L and 8L patches significantly reduced 5-FU release. Thus, we
AC
assume that the drug release was affected by the changes of surface area depending on the geometric modifications. The tendency of reduction in drug release corresponds to the decrease of surface area to volume ratio (S:V ratio) in the tested structures, indeed (Table. 2). Therefore, the change of the structure using a 3D printing can easily alter the drug-release behavior.
18
ACCEPTED MANUSCRIPT Table 2. Theoretical S:V ratio of the various geometries of P150 patches
T
Lattice, 4L 9.64
Lattice, 8L 8.91
IP
Lattice, Slant, Triangular, 2L 3L 3L S:V ratio 22.20 20.30 20.29 2, 3, 4, and 8 L: layered 2, 3, 4, and 8 times, respectively.
SC R
Geometry
In the analysis of 5-FU release profile, eah of the 3D-printed PLGA/PCL/5-FU patches
NU
showed burst release in the first few hours, decreased release for 1 week, and then sustained
MA
release thereafter (Fig. 4A, Fig. S2). The 5-FU release was proportional to the amount of drug loaded in the patches. P150 released approximately 30% of the loaded drug over the 4-
D
week period.
TE
To explore the release mechanism of 5-FU from the printed patches, swelling and degradation studies were performed. All patches swelled rapidly in the first hour, but the
CE P
volume reached an asymptote within 24 h (Fig. 4B). The degree of swelling decreased as the amount of 5-FU increased. This trend may occur because 5-FU is hydrophobic.
AC
The P0 patch degraded very slowly: WD decreased by 29% over 120 days. The combination of increased hydrophobicity due to the loaded 5-FU, and slow degradation of the P0 patch suggests that degradation of the patches containing 5-FU should be slow. However, the weight loss of the patches increased with the loading amount of 5-FU (Fig. 4C). We assume that this phenomenon was due to the increased net loss, including both loss of polymers and 5-FU.
19
TE
D
MA
NU
SC R
IP
T
ACCEPTED MANUSCRIPT
CE P
Fig. 4. Release, swelling, and degradation profiles of 3D-printed PLGA/PCL/5-FU patches. (A) Cumulative 5-FU release (Cum. Rel.) profile of latticed, slanted, triangular patches and
AC
4- and 8-layered lattice patches for 6 days. (B) Cum. Rel. profile of P10, P50, P100, and P150 patches for 32 days. The amount of 5-FU released was normalized with the initial weight. (C) Degrees of swelling and (D) residual weight profiles of the patches for 96 h and 4 months, respectively.
3.4. Therapeutic effects in vitro MIA-PaCa-2 cells exposed to the serially diluted 5-FU died in a dose-dependent manner 20
ACCEPTED MANUSCRIPT (Fig. 5A). The relative cell viabilities of 5-FU treatment groups decreased slightly at low concentration of 5-FU, but decreased steeply at concentrations >1 μg/ml. The IC50 was 55.90
IP
T
μg/ml.
SC R
We then examined the cytotoxic and therapeutic effects of the 3D-printed patches on the hASCs and the MIA PaCa-2 cells. We estimated the concentrations of released 5-FU from the patches to be above the IC50–value in 200 μl of culture medium (Table S1). All kinds of the
NU
PLGA/PCL/5-FU patches inhibited the proliferation of MIA PaCa-2 cells to less than 50% (Fig. 5B). From the hASCs, although the significant decreases in the cell viability were
MA
observed from the P100 and P150 patches, the overall cell viability was maintained >50% in all kinds of patches (Fig. 5B). Thus, the 5-FU dosages loaded in the patches were effective
AC
CE P
TE
D
on the pancreatic cancer cell rather than on the non-malignant cell.
21
CE P
TE
D
MA
NU
SC R
IP
T
ACCEPTED MANUSCRIPT
Fig. 5. Therapeutic and cytotoxic effects of the 3D-printed patches. (A) Relative cell viability
AC
(Rel. cell viability) of MIA-PaCa-2 cells against the serial dilution of 5-FU. (B) Rel. cell viabilities of MIA-PaCa-2 cells and hASCs against the released 5-FU from P10, P50, P100, and P150 for 24 h.
3.5. Therapeutic effects in vivo The release study conducted for 4 weeks indicated that the concentration of 5-FU released decreased after the burst release and equilibrated after 1 week. Thus, the inhibitory effect of 22
ACCEPTED MANUSCRIPT 5-FU released from the patches should be examined for the same period as the release study. As we aimed to deliver the highly concentrated drug to cancer sites using the patches, we
T
selected P100 and P150 patches for in vivo study. A previous study that applied a high dose
IP
of 5-FU (132mg) showed effective treatment of cancer without the tissue damage in vivo [21].
SC R
Thus, we assumed that the survival of the non-malignant cells would be different in in vivo conditions, although the P100 and P150 patches showed some cytotoxicity on the non-
NU
malignant cells (56% and 62% of cell viability, respectively) in vitro. The patch was attached under the tumor (Fig. 6A). Tumor size significantly decreased in
MA
mice that received P100 or P150 patches compared to the P0 patch group (Fig. 6B). The size of the excised tumors from the mice implanted with P100 and P150 patches were much
D
smaller than those of no treatment and P0 patch groups at four weeks (Fig. 6C). Interestingly,
TE
the tumor growth was inhibited more significantly in the mice implanted with P100 patch
CE P
than in the mice implanted with P150 patch at 24 and 28 days (Fig. 6B). P150 decreased the tumor size more than the P100 did in the first 5 days, but thereafter the decrease in size was
AC
insignificant, whereas P100 decreased the tumor size constantly.
23
CE P
TE
D
MA
NU
SC R
IP
T
ACCEPTED MANUSCRIPT
AC
Fig. 6. Therapeutic effects of 3D-printed PLGA/PCL/5-FU patches on pancreatic cancer. (A) Photographs of the subcutaneous pancreatic cancer xenograft (T) before and after implantation of the patch (black arrowheads) at the bottom of the tumor. Scale bar: 1 cm. (B) Changes of relative tumor size of mice that received P100 and P150 patches against that of the P0 patch implantation group. *: P < 0.05 between P100 and P150 groups. (C) Photographs of the excised tumors and the patches at four weeks after implantation. The arrow indicates the flexibility of the implanted P150 patch. Scale bar: 2 mm.
24
ACCEPTED MANUSCRIPT We stained tissue sections of excised tumors to evaluate the effect of the released drug on cell morphology and proliferation in the tumors. In H&E histology, the tissue sections of both
T
no treatment and P0 patch-implanted groups show the typical pattern of demarcated, densely-
IP
cellular neoplasm, and central hypoxia at 1 week (Fig. 7A). In immunofluorescence images
SC R
(Fig. 7B), the human pancreatic cancer cells were detected by staining with h-lamin. The hlamin-positive cells and h-lamin-negative cells were also distinguishable in the two groups at
NU
1 week, showing demarcated tumor formation.
Ki-67 is a nuclear protein that is associated with cellular proliferation. The tumors of the no
MA
treatment and P0 patch-implanted groups exhibited large numbers of Ki-67-positive nuclei in both the tumor and the surrounding normal tissues. The tumors developed their invasive
D
morphology in H&E and immunofluorescence images at 4 weeks. In H&E histology,
TE
hematoxylin-unstained nuclei indicate apoptotic cells were detected near the implanted patch
CE P
in both P100 and P150 groups. The area of apoptotic cells was less extensive in the P100 group then that in the P150 group at 1 week. The P100 group also showed a narrow region of
AC
Ki-67-negative and h-lamin-positive cells near the patch. However, the tendency of P100 versus P150 on the apoptotic cells was reversed at 4 weeks. The P150 group showed strong staining of the nuclei in the tumor near the patch and showed damaged tissue of the skin on top of the tumor in H&E staining. Relatively more Ki-67positive nuclei were observed in the tumors of the P150 group than in those of the P100 group. In contrast, the tumor mass on top of the patch was weakened and the extent over which Ki-67-positive nuclei of h-lamin-negative cells was observed in the P100 group; these results suggest that damage to the surrounding normal tissue was minimized. As we observed 25
ACCEPTED MANUSCRIPT from the in vitro results (Fig. 5B), the P150 patch has the higher toxicity on the nonmalignant cells, compared to the P100 patch has, which may induce the tissue damage on the
AC
CE P
TE
D
MA
NU
SC R
IP
T
skin on top of the tumor.
Fig. 7. Morphology and proliferation in tumors at 1 and 4 weeks after the implantation of the 3D-printed patches. (A) H&E staining of tissue sections. Scale bar: 250 μm. (B) Immunofluorescence staining against Ki67 in green and human lamin (h-lamin) in red. Nuclei were stained with DAPI (blue). Scale bar: 100 μm. T: tumor. P: implanted patch. Red arrows: non-proliferating tumor cells near the implanted patch. Green arrows: proliferating non-malignant cells near the implanted patch. 26
ACCEPTED MANUSCRIPT 3.6. Evaluations of systemic toxicity The rhodamine B administrated to the mice was visualized using in vivo imaging analysis.
IP
T
The injected rhodamine B spread over the whole-body right after the injection was shown
SC R
with the highest fluorescent intensity at 30 min, and rapidly diminished for 6 days (Fig. 8A and C). On the other hand, the rhodamine B released from the 3D-printed patches was detected only in the patch implanted region and with the similar intensity levels at 1 and 4
NU
weeks (Fig. 8B, D). The released rhodamine B was not shown on the internal organs except
MA
for the P150’ at 1 week.
The drug concentration in plasma was determined after administrating 5-FU into the mice
D
through the i.v. injection, and implantation of P100 and P150 patches. The high level of 5-FU
TE
was detected in each group at the initial day of the implantation surgery (Fig. 8E). However, the 5-FU level in plasma significantly decreased in the patch-implanted mice at 1 and 4
CE P
weeks, except for i.v. group. The high level of 5-FU also influenced the liver function. While the mice in i.v. group showed constantly abnormal level of GOT for 4 weeks, the mice
AC
implanted with P100 and P150 patches showed similar levels to that of the P0 patchimplanted mice from 1 week (Fig. 8F). There was no significant change in the kidney function (Fig. 8G). The weights of the tumor-bearing mice increased in all groups; this observation indicates that the mice could tolerate highly concentrated 5-FU released from the patches and suffer no obvious toxicity. Besides, no mice died in any group during the experiment period. Therefore, taken together, we demonstrated that the 3D-printed patch facilitates highly-localized drug delivery and minimization of systemic toxicity.
27
AC
CE P
TE
D
MA
NU
SC R
IP
T
ACCEPTED MANUSCRIPT
Fig. 8. Analysis of the drug release in vivo. Time-dependent visualization of rhodamine B administrated by (A) the i.v. injection and (B) 3D-printed patch implantation. Time28
ACCEPTED MANUSCRIPT dependent changes of fluorescence intensities in (C) the i.v. injection and (D) the P100’ and P150 patch implantation groups. (E) 5-FU concentration (5-FU Conc.), and (F) GOT and (G)
T
BUN levels in the plasma harvested at the initial day, 1 week, and 4 weeks. (H) Changes in
IP
body weight of tumor-bearing mice with no treatment, P0, 100, and 150 patches. *: P < 0.05
Discussion
NU
4.
SC R
vs. i.v. group. #: P < 0.05 vs. P0 group.
MA
Here, we are exploring 3D-printed patches for the delivery of an anti-cancer drugs to specific regions near tumors. 3D printing technology provides a facile and versatile way to
D
fabricate drug delivery platforms [22]. The diverse shapes of the printed patches suggest that
TE
extrusion printing would facilitate design effectively tailored to cover the margin of the diseased area. Additionally, as shown in Fig. 4A, the 3D printing process to control the pore
CE P
shapes and total thickness of the patch allows specific modification of the release characteristics by altering the S:V ratio, which affects the diffusion rate. Goyanes et al. also
AC
reported that the various 3D geometries influenced the drug release due to the alterations of S:V ratio [23]. Whereas the porosity of microspheres is determined by adjusting the use of solvents or emulsion process [24, 25], 3D printing technology allows the direct manipulation of the geometry according to a specific purpose [26, 27]. Currently, Particle Replication in Nonwetting Templates (PRINT) technology can produce the anti-cancer drug loaded particles by layer-by-layer process and can control the release profile by changing the particle’s geometry or size or chemical composition as in 3D printing technology [28]. PLGA/PCL blend was chosen for our approach, because it accrues both advantages of 29
ACCEPTED MANUSCRIPT PLGA and PCL. Although the chemical and mechanical characteristics of PLGA are tunable by altering the lactide:glycolide ratio [29], PLGA alone cannot achieve both a long drug
T
release time and flexibility simultaneously. This is because the increased lactide proportion
IP
not only prolongs the release and degradation time frame, but also enhances the rigidity of
SC R
the material. Therefore, the PLGA/PCL blended polymer has been widely studied for biomedical applications. Cha et al. demonstrated the remarkably prolonged release and
NU
degradation time from the PLGA/PCL blend [30]. The inherent ductility of PCL could allow the 3D-printed PLGA/PCL/5-FU patch to be flexible and deformable to attach on the
MA
contours of soft tissue.
5-FU was used as a prototype drug in the present study because it has been broadly used in
D
gastrointestinal cancers, head and neck cancers, and central nervous system cancers [21, 31].
TE
In particular, the combination of 5-FU with high intensity focused ultrasound (HIFU) has
CE P
been reported to enhance the efficiency of the drug delivery [32]. 5-FU has also been studied for use in the local drug delivery systems, but the investigation of therapeutic efficacy of these systems has yet to be exhibited [21, 33]. Therefore, additional efforts are encouraged to
AC
explore advanced drug delivery systems that enable localized therapeutic effects. To establish proof-of-concept for delivering an anticancer-drug via a 3D-printed patch, we generated a pancreatic cancer model. Only less than 20% patients are candidates for surgical resection, because pancreatic cancers are usually detected at late stage when the cancer has already metastasized to other organs [34]. Moreover, among the patients received surgical resection, the residual cancer cells easily cause the local recurrence [35]. Thus, implantation of a local drug delivery system during the surgery would be ideal to suppress the remnant 30
ACCEPTED MANUSCRIPT microscopic tumor, and to inhibit the tumor recurrence. Indeed, for the treatment of brain tumor, Gliadel Wafer®, a carmustine incorporating biodegradable wafer, has been utilized to
T
implant in the resection cavity following surgical removal. Similarly, we expect that the 3D-
SC R
IP
printed patch can also be directly implanted onto the tumor-removed region. In particular, 3D printing technology provides many advantages to generate local drug delivery systems. Because this technology allows to build a construct as desired, the 3D-
NU
printed patch can be fabricated with a specific shape that is fit to the tumor-resected site; thereby, it may benefit palliative effect as well as improving the quality of life for some
MA
patients suffering from late-stage pancreatic cancer [3]. Furthermore, the 3D-printed patch can be also applied to other types of cancer including prostate, colon, uterine corpus, and
D
female breast cancer, which are diagnosed at early locoregional stage. Despite surgical
TE
resection, these cancers leave undetected microscopic cancer cells, which lead to cancer
kinds of cancer.
CE P
recurrence. Thus, the 3- printed patch can be also be effective for local therapy for these
AC
The important requisites for designing this application are the prolonged and sustained release of the drug, and administration of a dosage within the therapeutic window without inducing systemic toxicity [3]. In this study, the printed PLGA/PCL patches released approximately 20% of 5-FU over 4 weeks and degraded over 4 months. Although a further release study is required to track the total loss of the drug, the P100 and P150 patches showed therapeutic effects during the experiment period. Interestingly, the administered concentration of 5-FU by attaching a single P100 patch (180 mg/kg of mouse weight) is approximately 3 times that of intravenous bolus injection (60 mg/kg), while the mice showed 31
ACCEPTED MANUSCRIPT no obvious side effectss such as decreased liver function and weight loss. The 3D-printed PLGA/PCL/5-FU patch have potential as an effective vehicle for delivering drugs to achieve
T
both high efficacy and minimized systemic toxicity for cancer treatment by enabling precise
SC R
Conclusions
NU
5.
IP
control of the amount and location of drug loaded.
We developed a biodegradable patch that contains a high concentration of an anti-cancer
MA
drug for a localized administration of the drug to the exact site of a tumor. 3D printing of the porous patches with the diverse shapes demonstrated the ability to manipulate the drug
D
release by altering the surface area. Besides, the PLGA/PCL/5-FU patches exhibited the
TE
attachable flexibility, prolonged release period, and a significant suppressive effect on the growth of a subcutaneous pancreatic cancer xenograft with minimized side effects. These
CE P
results indicate that use of 3D-printed patches will allow effectively localized delivery of
AC
anti-cancer drugs while achieving an ideal pharmacokinetics.
Acknowledgment
This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIP) (No. 2010-0018294) and by a grant from the Korean Health Technology R & D Project, Ministry of Health & Welfare, Republic of Korea (grant no. HI14C2640).
32
ACCEPTED MANUSCRIPT References [1] M. Loos, J. Kleeff, H. Friess, M.W. Büchler, Surgical treatment of pancreatic cancer,
IP
T
Annals of the New York Academy of Sciences, 1138 (2008) 169-180.
SC R
[2] S.F. Sener, A. Fremgen, H.R. Menck, D.P. Winchester, Pancreatic cancer: a report of treatment and survival trends for 100,313 patients diagnosed from 1985–1995, using the National Cancer Database, Journal of the American College of Surgeons, 189 (1999) 1-7.
NU
[3] J.B. Wolinsky, Y.L. Colson, M.W. Grinstaff, Local drug delivery strategies for cancer treatment: gels, nanoparticles, polymeric films, rods, and wafers, Journal of controlled release,
MA
159 (2012) 14-26.
[4] E.A. Murphy, B.K. Majeti, L.A. Barnes, M. Makale, S.M. Weis, K. Lutu-Fuga, W.
D
Wrasidlo, D.A. Cheresh, Nanoparticle-mediated drug delivery to tumor vasculature
TE
suppresses metastasis, Proceedings of the National Academy of Sciences, 105 (2008) 9343-
CE P
9348.
[5] K. Matthes, M. Mino-Kenudson, D.V. Sahani, N. Holalkere, K.D. Fowers, R. Rathi, W.R. Brugge, EUS-guided injection of paclitaxel (OncoGel) provides therapeutic drug
448-453.
AC
concentrations in the porcine pancreas (with video), Gastrointestinal endoscopy, 65 (2007)
[6] J.B. Wolinsky, R. Liu, J. Walpole, L.R. Chirieac, Y.L. Colson, M.W. Grinstaff, Prevention of in vivo lung tumor growth by prolonged local delivery of hydroxycamptothecin using poly (ester-carbonate)-collagen composites, Journal of Controlled Release, 144 (2010) 280-287. [7] B.M. Wu, S.W. Borland, R.A. Giordano, L.G. Cima, E.M. Sachs, M.J. Cima, Solid freeform fabrication of drug delivery devices, Journal of Controlled Release, 40 (1996) 77-87. [8] N. Faisant, J. Benoit, P. Menei, Development of 5-FU-Loaded PLGA Microparticles for 33
ACCEPTED MANUSCRIPT the Treatment of Glioblastoma, DRUGS AND THE PHARMACEUTICAL SCIENCES, 158 (2006) 673.
T
[9] J. Liu, Z. Wang, K. Wu, J. Li, W. Chen, Y. Shen, S. Guo, Paclitaxel or 5-
IP
fluorouracil/esophageal stent combinations as a novel approach for the treatment of
SC R
esophageal cancer, Biomaterials, 53 (2015) 592-599.
[10] S.E. Moulton, G.G. Wallace, 3-dimensional (3D) fabricated polymer based drug delivery
NU
systems, Journal of Controlled Release, 193 (2014) 27-34.
[11] E.Y. Teo, S.-Y. Ong, M.S.K. Chong, Z. Zhang, J. Lu, S. Moochhala, B. Ho, S.-H. Teoh,
MA
Polycaprolactone-based fused deposition modeled mesh for delivery of antibacterial agents to infected wounds, Biomaterials, 32 (2011) 279-287.
D
[12] J.-H. Shim, M.-J. Kim, J.Y. Park, R.G. Pati, Y.-P. Yun, S.E. Kim, H.-R. Song, D.-W. Cho,
TE
Three-dimensional printing of antibiotics-loaded poly-ε-caprolactone/poly (lactic-co-glycolic
CE P
acid) scaffolds for treatment of chronic osteomyelitis, Tissue Engineering and Regenerative Medicine, 12 (2015) 283-293.
[13] J.Y. Kim, D.-W. Cho, Blended PCL/PLGA scaffold fabrication using multi-head
AC
deposition system, Microelectronic Engineering, 86 (2009) 1447-1450. [14] J.S. Lee, H.D. Cha, J.H. Shim, J.W. Jung, J.Y. Kim, D.W. Cho, Effect of pore architecture and stacking direction on mechanical properties of solid freeform fabrication‐based scaffold for bone tissue engineering, Journal of Biomedical Materials Research Part A, 100 (2012) 1846-1853. [15] T. Chandy, G. Das, G. Rao, 5-Fluorouracil-loaded chitosan coated polylactic acid microspheres
as
biodegradable
drug
carriers
microencapsulation, 17 (2000) 625-638. 34
for
cerebral
tumours,
Journal
of
ACCEPTED MANUSCRIPT [16] P. Kalantarian, A.R. Najafabadi, I. Haririan, A. Vatanara, Y. Yamini, M. Darabi, K. Gilani, Preparation of 5-fluorouracil nanoparticles by supercritical antisolvents for pulmonary
T
delivery, International journal of nanomedicine, 5 (2010) 763.
IP
[17] H. Okino, R. Maeyama, T. Manabe, T. Matsuda, M. Tanaka, Trans-tissue, sustained
SC R
release of gemcitabine from photocured gelatin gel inhibits the growth of heterotopic human pancreatic tumor in nude mice, Clinical cancer research, 9 (2003) 5786-5793.
NU
[18] D. Liu, C. Poon, K. Lu, C. He, W. Lin, Self-assembled nanoscale coordination polymers with trigger release properties for effective anticancer therapy, Nature communications, 5
MA
(2014).
[19] S. Mahoney, J. Davis, E. Murphy, J. McClellan, B. Gordon, M. Pena, Effects of 5-
D
fluorouracil chemotherapy on fatigue: role of MCP-1, Brain, behavior, and immunity, 27
TE
(2013) 155-161.
CE P
[20] G.M. Zentner, R. Rathi, C. Shih, J.C. McRea, M.-H. Seo, H. Oh, B. Rhee, J. Mestecky, Z. Moldoveanu, M. Morgan, Biodegradable block copolymers for delivery of proteins and water-insoluble drugs, Journal of Controlled Release, 72 (2001) 203-215.
AC
[21] P. Menei, M.C. Venier, E. Gamelin, J.P. Saint‐André, G. Hayek, E. Jadaud, D. Fournier, P. Mercier, G. Guy, J.P. Benoit, Local and sustained delivery of 5‐fluorouracil from biodegradable microspheres for the radiosensitization of glioblastoma, Cancer, 86 (1999) 325-330. [22] P. Rattanakit, S.E. Moulton, K.S. Santiago, S. Liawruangrath, G.G. Wallace, Extrusion printed polymer structures: a facile and versatile approach to tailored drug delivery platforms, International journal of pharmaceutics, 422 (2012) 254-263. [23] A. Goyanes, P.R. Martinez, A. Buanz, A.W. Basit, S. Gaisford, Effect of geometry on 35
ACCEPTED MANUSCRIPT drug release from 3D printed tablets, International journal of pharmaceutics, 494 (2015) 657663.
T
[24] G. Crotts, T.G. Park, Preparation of porous and nonporous biodegradable polymeric
IP
hollow microspheres, Journal of Controlled Release, 35 (1995) 91-105.
SC R
[25] Y.-Y. Yang, T.-S. Chung, X.-L. Bai, W.-K. Chan, Effect of preparation conditions on morphology and release profiles of biodegradable polymeric microspheres containing protein
NU
fabricated by double-emulsion method, Chemical Engineering Science, 55 (2000) 2223-2236. [26] J.W. Jung, H.-G. Yi, T.-Y. Kang, W.-J. Yong, S. Jin, W.-S. Yun, D.-W. Cho, Evaluation of
MA
the effective diffusivity of a freeform fabricated scaffold using computational simulation, Journal of biomechanical engineering, 135 (2013) 084501.
D
[27] N. Yang, K. Zhou, Effective method for multi-scale gradient porous scaffold design and
TE
fabrication, Materials Science and Engineering: C, 43 (2014) 502-505.
CE P
[28] J. Xu, D.H. Wong, J.D. Byrne, K. Chen, C. Bowerman, J.M. DeSimone, Future of the particle replication in nonwetting templates (PRINT) technology, Angewandte Chemie International Edition, 52 (2013) 6580-6589.
AC
[29] Z. Tang, N. Rhodes, J. Hunt, Control of the domain microstructures of PLGA and PCL binary systems: importance of morphology in controlled drug release, Chemical Engineering Research and Design, 85 (2007) 1044-1050. [30] Y. Cha, C. Pitt, The biodegradability of polyester blends, Biomaterials, 11 (1990) 108112. [31] J.S. Kovach, C.G. Moertel, A.J. Schutt, R.G. Hahn, R.J. Reitemeier, A controlled study of combined 1, 3‐bis‐(2‐chloroethyl)‐1‐nitrosourea and 5‐fluorouracil therapy for advanced gastric and pancreatic cancer, Cancer, 33 (1974) 563-567. 36
ACCEPTED MANUSCRIPT [32] H.-Y. Ge, L.-Y. Miao, L.-L. Xiong, F. Yan, C.-S. Zheng, J.-R. Wang, J.-W. Jia, L.-G. Cui, W. Chen, High-intensity focused ultrasound treatment of late-stage pancreatic body
T
carcinoma: optimal tumor depth for safe ablation, Ultrasound in medicine & biology, 40
IP
(2014) 947-955.
SC R
[33] H. Gao, Y. Gu, Q. Ping, The implantable 5-fluorouracil-loaded poly (l-lactic acid) fibers prepared by wet-spinning from suspension, Journal of Controlled Release, 118 (2007) 325-
NU
332.
[34] Cancer Facts & Figures 2014, Atlanta: American Cancer Society, (2014).
MA
[35] T. Manabe, H. Okino, R. Maeyama, K. Mizumoto, M. Tanaka, T. Matsuda, New infusion device for trans‐tissue, sustained local delivery of anticancer agent to surgically resected
D
tissue: Potential use for suppression of local recurrence of pancreatic cancer, Journal of
AC
CE P
TE
Biomedical Materials Research Part B: Applied Biomaterials, 73 (2005) 203-207.
37