Part 11: Styrene Copolymers 28. ABS Chapter Outline: 28.1 ABS 28.1 ABS Exposure medium Accelerated Weathering
Acetaldehyde
Acetamide
% Change
% Retained
Temp. (°C)
Time (days)
PDL #
63
210
2
Data from SPE ANTEC 1991 Conference Proceedings
Atlas WeatherO-Meter
7
9
Data from 1989 SPE ANTEC Conference Proceedings
Specimen: ABS with 17% Occidental Dechlorane Plus chlorinated flame retardant
"
7
2
"
Specimen: ABS with 16% Bis(tribromo phenoxy) ethane flame retardant
"
7
0
"
Specimen: ABS with 14% Octabromodiphenyl Oxide OBDPO flame retardant
Exp. medium note
Conc. (%)
ASTM D2565 xenon arc; 6300 kJ/sq-m; 18 min. water spray every 2 hrs.
Resistance note Weight
Elong.
Tensile strength
Impact strength
53
Test note
Material note
Impact retained is energy to failure
Specimen: 4.8 mm (0.19 in) thick plaque
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2
Not recommended; severe effect
Cycolac; GE Plastics
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
Woishnis and Ebnesajjad. Chemical Resistance of Thermoplastics. DOI: 10.1016/B978-1-4557-7896-6.00028-5
Acetic Acid
Exp. medium note
% Change
% Retained
Temp. (°C)
Time (days)
PDL #
5
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
5
23
7
9
Almost no change in either appearance or physical properties
5
23
7
9
No change observed
0.40]0.48
100.0]100.5
Toyolac 900; Toray Industries
5
23
7
9
No noticeable change in appearance
0.48
100
"
5
23
7
9
"
0.48
100
Toyolac 900; Toray Industries; Specimen: Transparent
10
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
10
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical
10
23
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
10
52
28
7
"
Magnum; Dow Chemical
10
52
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
25
20
9
Resistant over a period of months to years
Terluran; BASF
25
20
9
"
25
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto
25
23
7
8
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
25
50
9
Resistant over a period of months to years
Terluran; BASF
25
50
9
"
Terlux; BASF
50
20
9
"
Terluran; BASF
50
20
9
"
Terlux; BASF
50
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
50
23
7
8
Resistant - no visual change observed
Conc. (%)
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
Strained in bending fixture
Cycolac; GE Plastics
2688
Exposure medium
Starex; LG Chem
Terlux; BASF
Lustran; Monsanto
ABS
Chemical resistance per ASTM D543
Acetic Acid (cont)
Exp. medium note
% Change
% Retained
Time (days)
PDL #
50
23
7
8
Resistant - no visual change observed
50
23
7
9
No change observed
0.71
97.4
Toyolac 100; Toray Industries
50
23
7
9
"
0.71
97.4
Toyolac 300; Toray Industries
50
23
7
9
"
0.71
97.4
Toyolac 500; Toray Industries
50
23
7
9
"
0.71
97.4
Toyolac 600; Toray Industries
50
23
7
8
Slightly yellowish discoloration
0.63]0.70
101.8]102.8
Toyolac 900; Toray Industries
50
23
7
8
Slightly yellowed
0.7
102
"
50
23
7
8
"
0.7
102
Toyolac 900; Toray Industries; Specimen: Transparent
50
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical
50
23
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
50
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
50
50
4
"
Terlux; BASF
50
52
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical
50
52
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
75
23
2
Not acceptable
75
65
2
"
98
23
1
Unsuitable due to decomposition; swelling; dissolution
Starex; LG Chem
100
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
7
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2689
Temp. (°C)
Conc. (%)
ABS
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
100
20
glacial
100
23
"
100
" "
Time (days)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto
23
7
2
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical
100
23
28
2
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
100
50
1
"
Terlux; BASF
glacial
100
52
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical
"
100
52
28
2
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
"
23
7
0
Sample failed; data from Georgia Gulf PVC literature
Flexure; samples placed in 20° bend
Cycolac KJU; GE Plastics
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto
23
7
8
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Acetic Acid (cont)
2690
Exposure medium
Terlux; BASF
23
7
89.8
23
4
74.5
23
7
89.8
LNP Engineering Plastics; Filler: Glass fiber; Specimen: ASTM D1822 tensile impact samples Flexural stress
"
ABS
LNP Engineering Plastics; Filler: 30% Glass fiber
Exp. medium note
Conc. (%)
Acetic Acid (cont)
Temp. (°C)
Time (days)
Acetone
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
23
7
89.8
23
4
74.5
Flexural stress
LNP Engineering Plastics; Filler: 30% Glass fiber
23
4
74.5
"
LNP Engineering Plastics; Filler: 30% Glass fiber; Specimen: ASTM D1822 tensile impact samples
glacial
Acetic Anhydride
% Change PDL #
LNP Engineering Plastics; Filler: 30% Glass fiber; Specimen: ASTM D1822 tensile impact samples
5
Questionable; moderate effect
Cycolac; GE Plastics
2
Not recommended; severe effect
"
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
2
Not recommended; severe effect
Cycolac; GE Plastics
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
100
23
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
20
ABS
Exposure medium
"
Terlux; BASF
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
4
Softened noticeably
Starex; LG Chem
23
7
3
Swelled and partially solved
Toyolac 100; Toray Industries
2691
1
23
Exp. medium note
Conc. (%)
Acetone (cont)
% Retained
Time (days)
PDL #
23
7
3
Swelled and partially solved
Toyolac 300; Toray Industries
23
7
3
"
Toyolac 500; Toray Industries
23
7
3
"
Toyolac 600; Toray Industries
23
7
0
Dissolved
Toyolac 900; Toray Industries
23
7
0
"
Toyolac 900; Toray Industries; Specimen: Transparent
50
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
50 75
1
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
1
"
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
2
Not recommended; severe effect
Cycolac; GE Plastics Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
100
23
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
Acetonitrile
Acetophenone
% Change
Temp. (°C)
2692
Exposure medium
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
Exp. medium note
Conc. (%)
Time (days)
Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
2
Not recommended; severe effect
Cycolac; GE Plastics
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
"
3M 468
23
7
Weld-On 1001
23
7
9
"
"
"
Weld-On 10-2
23
7
4
"
"
"
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
90
9
Maximum continuous service temperature is HDT
Toyolac 300; Toray Industries
91
9
"
Toyolac 100; Toray Industries
91
9
"
Toyolac 600; Toray Industries
94
9
"
Toyolac 500; Toray Industries
96
9
"
Toyolac 300; Toray Industries
98
9
"
Toyolac 100; Toray Industries
98
9
"
Toyolac 600; Toray Industries
99
9
"
Toyolac 500; Toray Industries
Adipic Acid
Air
Aircraft Fuels
% Retained
Resistance note
1
Acrylonitrile Adhesives
% Change PDL #
50
Acetophenone (cont)
Acetylsalicylic Acid
Temp. (°C)
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
2
Severe attack; softened in few hrs
"
2693
aviation gasoline
ABS
Exposure medium
Exp. medium note
PDL #
23
7
9
No noticeable change in appearance
23
7
7
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
"
23
7
2
"
"
"
with ammonia; multi surface cleaner
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
multi surface cleaner
3
Almond Oil
Weight
0.09
Elong.
Tensile strength
Impact strength
Test note
100
Material note Toyolac 900; Toray Industries; Specimen: Transparent
2
Poor resistance
RTP 600; RTP Company
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
2
Not resistant; plastic severely crazed; softened or dissolved
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
50
1
"
Terlux; BASF
20
1
"
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
20
9
Resistant over a period of months to years
Terluran; BASF
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
20
9
Resistant over a period of months to years
"
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
50
9
Resistant over a period of months to years
"
23
Allyl Mustard Oil
Resistance note
20
Alcohols Allyl Alcohol
% Retained
Time (days)
Aircraft Turbine Oils Ajax
% Change
Temp. (°C)
Conc. (%)
7
2694
Exposure medium
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
ABS
Exp. medium note
Conc. (%)
Almond Oil (cont)
Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
50
9
Resistant over a period of months to years
"
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
2
"
"
"
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
9
100
52
28
9
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
saturated solution
23
8
Resistant - no visual change observed
solution
50
9
Resistant over a period of months to years
"
7
50
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
9
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
2695
Aluminum Hydroxide
% Retained
Resistance note
solution
Aluminum Chloride
Aluminum Fluoride
% Change PDL #
7
alpha-Methylnaphthalene
Aluminum Alum
Time (days)
23
alphaChloronaphthalene
Aluminum Acetate
Temp. (°C)
ABS
Exposure medium
Aluminum Hydroxide (cont) Aluminum Potassium Sulfate
Exp. medium note
% Change
% Retained
Temp. (°C)
Time (days)
PDL #
52
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
saturated
23
28
9
Plastic was unaffected for duration of test
"
"
52
28
9
"
"
100
23
28
9
"
"
100
52
28
9
"
"
Conc. (%) 100
Aluminum Sulfate
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
saturated
23
8
Resistant - no visual change observed
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
7
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
10
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
10
23
7
9
Almost no change in either appearance or physical properties
Starex; LG Chem
NH3 water
10
23
7
9
No change observed
0.40]0.53
97.0]98.0
Toyolac 900; Toray Industries
ammonia water
10
23
7
9
No noticeable change in appearance
0.53
97
Toyolac 900; Toray Industries; Specimen: Transparent
25
20
9
Resistant over a period of months to years
25
20
9
"
Terlux; BASF
25
50
9
"
Terluran; BASF
Ammonia
2696
Exposure medium
Terluran; BASF
25
50
9
"
NH3 water
28
23
7
8
Slightly yellowish discoloration
0.55]0.65
100.0]100.8
Toyolac 900; Toray Industries
Terlux; BASF
ammonia water
28
23
7
8
Slightly yellowed
0.65
100
Toyolac 900; Toray Industries; Specimen: Transparent
50
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
ABS
Exp. medium note
Ammonia (cont)
Ammonium Acetate
Time (days)
PDL #
100
23
28
7
100
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Very slight clouding/ discoloration; expected life: months to years
Material note Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
52
28
7
"
aqueous solution
23
7
8
Resistant - no visual change observed
saturated
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
Ammonium Carbonate
" Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
52
28
9
"
"
100
23
28
9
"
"
100
52
28
9
"
"
9
Resistant over a period of months to years
Terluran; BASF
solution
20
"
20 23
7
9
"
8
Resistant - no visual change observed
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
Ammonium Chloride
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Specimen: In accordance with ASTM D543-84
100
23
28
9
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
Magnum; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
saturated
23
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
28
2697
Ammonium Fluoride
% Change
Temp. (°C)
Conc. (%)
ABS
Exposure medium
Ammonium Fluoride (cont) Ammonium Hydroxide
Exp. medium note
% Change
% Retained
Temp. (°C)
Time (days)
PDL #
52
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
10
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
10
75
1
2
Poor resistance; loss of mechanical properties; swelling
"
10
81
3
67.4
LNP Engineering Plastics; Filler: Glass fiber; Specimen: ASTM D1822 tensile impact samples
10
81
3
67.4
LNP Engineering Plastics; Filler: 30% Glass fiber; Specimen: ASTM D1822 tensile impact samples
28
23
7
8
0.95
99.3
Toyolac 100; Toray Industries
28
23
7
8
0.95
99.3
"
28
23
7
8
0.95
99.3
Toyolac 300; Toray Industries
28
23
7
8
0.95
99.3
"
28
23
7
8
0.95
99.3
Toyolac 500; Toray Industries
28
23
7
8
0.95
99.3
"
28
23
7
8
0.95
99.3
Toyolac 600; Toray Industries
28
23
7
8
0.95
99.3
"
29
23
7
29
23
7
30
23
28
30
23
28
30
52
28
Conc. (%)
saturated
Resistance note Weight
7
Slightly yellowish discoloration
Slightly yellowish discoloration
Slightly yellowish discoloration
Slightly yellowish discoloration
Exposure stress is the critical stress (level at which part stress cracks)
Elong.
Tensile strength
Impact strength
Test note
Material note
Strained in bending fixture
Cycolac; GE Plastics
"
"
2698
Exposure medium
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84 7
Very slight clouding/ discoloration; expected life: months to years
"
ABS
"
Exp. medium note
% Change
% Retained
Temp. (°C)
Time (days)
PDL #
30
52
28
3
Considerable change; expected life: days
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
50
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
concentrated
23
7
"
23
7
"
23
28
"
23
28
Ammonium Hydroxide (cont)
Conc. (%)
Resistance note Weight
8
Elong.
Tensile strength
Resistant - no visual change observed
5
23
2
57
23
5
78.2
23
2
57
"
52
28
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
"
"
" 78.2
28
Material note
Chemical resistance per ASTM D543
Moderate effect; expected life: weeks to months
5
52
Test note
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
23
concentrated
Impact strength
ABS
Exposure medium
LNP Engineering Plastics; Filler: Glass fiber; Specimen: ASTM D1822 tensile impact samples Flexural stress
" LNP Engineering Plastics; Filler: 30% Glass fiber; Specimen: ASTM D1822 tensile impact samples
Flexural stress
" Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
3
Considerable change; expected life: days
" Cycolac; GE Plastics
Ammonium Molybdate
Ammonium m-Phosphate
Acceptable; minor effect
" Terluran; BASF
solution
20
9
Resistant over a period of months to years
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
100
23
28
9
"
"
2699
Ammonium Nitrate
7
Exp. medium note
Conc. (%) 100
Ammonium Nitrate (cont)
PDL #
52
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
9
"
Terlux; BASF
100
50 23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
Ammonium Sulfate
9
"
Terlux; BASF
100
50 23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
9
Resistant over a period of months to years
Terluran; BASF
solution
20
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
"
Terlux; BASF
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
n-amyl acetate
100
23
28
2
Severe attack; softened in few hrs
"
"
100
23
28
2
"
Magnum; Specimen: In accordance with ASTM D543-84
"
100
52
28
2
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
2
"
Magnum; Specimen: In accordance with ASTM D543-84
ABS
9
100
Ammonium Thiocyanate
Amyl Acetate
% Retained
Time (days)
solution
Ammonium Persulfate
Ammonium Rhodanide
% Change
Temp. (°C)
2700
Exposure medium
Exp. medium note
Conc. (%)
Amyl Acetate (cont)
Amyl Alcohol
Temp. (°C)
Time (days)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac
23
7
2
"
"
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
2
"
"
Lustran; Specimen: 50.8 mm (2 in) diameter discs
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
n-amyl alcohol
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
23
28
9
"
Magnum; Specimen: In accordance with ASTM D543-84
"
100
52
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
2
"
Magnum; Specimen: In accordance with ASTM D543-84
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
n-amyl alcohol
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
"
23
7
8
"
"
Lustran; Specimen: 50.8 mm (2 in) diameter discs
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
50
ABS
Exposure medium
Terluran; BASF
2701
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
50
Amyl Alcohol (cont)
Amyl Chloride
Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
7
Acceptable; minor effect
Cycolac
7
"
Cycolac; GE Plastics
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
20
1
"
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
Amyl Mercaptan
50 n-amyl phthalate
23
7
1
"
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Terlux; BASF
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
2
"
100
23
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
Amylamine Aniline
% Retained
Resistance note
100
Amyl Cinnamaldehyde
Amyl Phthalate
% Change PDL #
20
20
2702
Exposure medium
"
1
"
Terlux; BASF
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
23
7
0
Dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
Toyolac 900; Toray Industries
Exp. medium note
Conc. (%)
Aniline (cont)
Anise Oil
PDL #
23
7
0
Dissolved
Toyolac 900; Toray Industries; Specimen: Transparent
50
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
2
Not recommended; severe effect
Cycolac; GE Plastics
1
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
lard
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
9
"
"
"
22
1
6
Exposure strain is critical strain - level where stress cracks first appear
Variable strain bending form
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
"
23
7
4
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
"
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
20
20
Terluran; BASF
1
"
2
Not resistant; plastic severely crazed; softened or dissolved
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
20
9
Resistant over a period of months to years
Terluran; BASF
23
7
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2703
Aniseed
% Retained
Time (days)
75
Animal Fats
% Change
Temp. (°C)
ABS
Exposure medium
Exp. medium note
Conc. (%)
Aniseed (cont)
Antifreeze
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
20
9
Resistant over a period of months to years
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
7
4
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac
"
23
7
4
"
"
Cycolac; GE Plastics
7
Acceptable; minor effect
Cycolac
7
"
Cycolac; GE Plastics
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
Aqua Regia
100
23
28
7
100
52
28
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
2
100
52
28
2
"
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
concentrated
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
52
28
9
"
"
powder
23
28
9
"
"
"
52
28
9
"
"
9
Resistant over a period of months to years
Terluran; BASF
20
ABS
Atropine Sulfate
% Change PDL #
23
Apple Juice
Aspirin
Time (days)
Dowgard Permanent
Antimony Trichloride
Arsenic
Temp. (°C)
2704
Exposure medium
Exp. medium note
Conc. (%)
Atropine Sulfate (cont)
Temp. (°C)
Time (days)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
20
9
Resistant over a period of months to years
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
4
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
Automotive Polish
DuPont 7
23
Barium Bromide
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
Barium Carbonate
100
23
28
9
100
52
28
9
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
9
Resistant over a period of months to years
23
solution
7
50
"
Barium Chloride
50
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
9
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
9
Resistant over a period of months to years
Terluran; BASF
solution
20
"
20 23
solution
7
50
"
50 100
23
28
9
"
8
Resistant - no visual change observed
9
Resistant over a period of months to years
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
9
"
Terlux; BASF
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
2705
Barium Hydroxide
7
ABS
Exposure medium
Exp. medium note
Barium Hydroxide (cont) Barium Sulfate Barium Sulfide
PDL #
100
52
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
9
"
"
100
52
28
9
"
"
100
23
28
9
"
"
100
52
28
Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
9
"
"
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
9
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
23
7
7
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
7
Acceptable; minor effect
23
7
8
Resistant - no visual change observed
7
Acceptable; minor effect
Cycolac; GE Plastics
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
over 3.2% alcohol
Beet Juice
Beet Sugar Liquors
undiluted
Resistance note
20
50
Benzaldehyde
% Retained
Time (days)
Beef Tallow
Beer
% Change
Temp. (°C)
Conc. (%)
100
23
28
2
100
52
28
"
Cycolac; GE Plastics Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
2
Not resistant; plastic severely crazed; softened or dissolved
23
7
2706
Exposure medium
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
Exp. medium note
Conc. (%)
Benzaldehyde (cont)
Benzene
Temp. (°C)
Time (days)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
2
Not recommended; severe effect
Cycolac; GE Plastics
100
23
28
100
23
28
100
52
28
100
52
28
ABS
Exposure medium
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84 0
Solvent
" "
0
Solvent
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
23
1
23
7
23
7
23
7
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
23
7
4
Softened noticeably
23
7
23
7
23
7
23
7
23
7
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
"
"
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
"
"
Starex; LG Chem Toyolac 100; Toray Industries
3
Swollen
" Toyolac 300; Toray Industries
3
Swollen
" Toyolac 500; Toray Industries
Swollen
"
2707
3
Exp. medium note
Conc. (%)
Benzene (cont)
% Change
% Retained
Temp. (°C)
Time (days)
23
7
23
7
23
7
23
7
23
7
23
7
0
Dissolved
"
50
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
0
Sample dissolved or severely tackified
LNP Engineering Plastics; Filler: Glass fiber; Specimen: ASTM D1822 tensile impact samples
75
1
81
PDL #
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
2708
Exposure medium
Toyolac 600; Toray Industries 3
Swollen
" Toyolac 900; Toray Industries
0
Dissolved
" Toyolac 900; Toray Industries; Specimen: Transparent
81
LNP Engineering Plastics; Filler: 30% Glass fiber; Specimen: ASTM D1822 tensile impact samples
81
0
Sample dissolved or severely tackified
" Cycolac; GE Plastics
Benzenesulfonic Acid
Benzoic Acid
2
Not recommended; severe effect
"
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
9
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
ABS
Exp. medium note
Conc. (%)
Benzoic Acid (cont) crystals
crystals
% Change
% Retained
Temp. (°C)
Time (days)
PDL #
23
7
8
Resistant - no visual change observed
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
52
28
9
Plastic was unaffected for duration of test
Benzonitrile
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Benzyl Acetate
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
2
Not resistant; plastic severely crazed; softened or dissolved
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
23
7
50
50
Benzyl Alcohol
Chemical resistance per ASTM D543
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
1
"
Terlux; BASF
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
20 23
50
7
"
2
Not resistant; plastic severely crazed; softened or dissolved
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
2709
1
ABS
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
50
Benzyl Alcohol (cont)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
2
Not recommended; severe effect
Cycolac; GE Plastics
Benzyl Benzoate
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Benzyl Chloride
23
7
2
"
"
"
Tests were conducted on a variable strain fixture which exhibits chemical resistance of a part under stress
Lustran ABS 248; Monsanto
Betadine
beta-Naphthol
liquid
23
8
Resistant
solution
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
"
20
4
"
Terlux; BASF
"
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
"
Bismuth Carbonate
Bismuth Chloride
Bismuth Subnitrate
"
Terlux; BASF
23
50 28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
"
20
9
"
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
7
Acceptable; minor effect
Cycolac; GE Plastics
Chlorox
ABS
Bleach
1
100
2710
Exposure medium
% Change
% Retained
Temp. (°C)
Time (days)
PDL #
Bluing
23
7
8
Resistant - no visual change observed
Bone Oil
20
9
Resistant over a period of months to years
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
Borax
Exp. medium note
Conc. (%)
Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
solution
20
9
"
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
Boric Acid
9
"
Terlux; BASF
100
50 23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
9
Resistant over a period of months to years
23
solution
Boron Trifluoride
7
50
"
Brake Fluids
Resistance note
50
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
9
"
Terlux; BASF
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
ATE
20
"
20
ABS
Exposure medium
1
"
Terlux; BASF
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
2711
Exp. medium note
Conc. (%)
Brake Fluids (cont)
Temp. (°C)
Time (days)
Weight
Elong.
Tensile strength
2
50.9
23
1
6.3
23
2
50.9
23
1
6.3
1
Impact strength
Test note
Material note LNP Engineering Plastics; Filler: Glass fiber; Specimen: ASTM D1822 tensile impact samples
Flexural stress
" LNP Engineering Plastics; Filler: 30% Glass fiber; Specimen: ASTM D1822 tensile impact samples
Flexural stress
"
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
ATE
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
"
50
1
"
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
81
2
Sample crazed or cracked
LNP Engineering Plastics; Filler: Glass fiber; Specimen: ASTM D1822 tensile impact samples
81
2
"
LNP Engineering Plastics; Filler: 30% Glass fiber; Specimen: ASTM D1822 tensile impact samples
20
9
Resistant over a period of months to years
Terluran; BASF
75
Brandy
1
20
Bromine
% Retained
Resistance note
23
50
Brines
% Change PDL #
2712
Exposure medium
9
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
10
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
10
50
1
2
"
"
75
1
2
"
"
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
ABS
10 100
Exp. medium note
Conc. (%) 100
Bromine (cont)
liquid
% Change
% Retained
Temp. (°C)
Time (days)
PDL #
52
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
"
20
bromine liquid
23
liquid
"
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
1
"
2
Not resistant; plastic severely crazed; softened or dissolved
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
50
1
"
Terlux; BASF
2
Not recommended; severe effect
Cycolac; GE Plastics
7
wet
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
Bromobutane
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Bromohexane
23
7
2
"
"
"
Butane
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
7
Acceptable; minor effect
23
7
butanes
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2-Butoxyethanol
23
7
8
Resistant - no visual change observed
"
"
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
5
Exposure strain is critical strain - level where stress cracks first appear
22
1
Variable strain bending form
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
2713
Butanethiol
Butter
ABS
Exposure medium
Exp. medium note
Conc. (%)
Butter (cont)
Time (days)
PDL #
23
7
8
Resistant - no visual change observed
9
Resistant over a period of months to years
50 50
Buttermilk Butyl Acetate
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
9
"
Terlux; BASF
7
Acceptable; minor effect
Cycolac; GE Plastics
7
"
"
n-butyl acetate
100
23
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
0
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
20 n-butyl acetate
Butyl Alcohol
% Change
Temp. (°C)
1
"
2
Not resistant; plastic severely crazed; softened or dissolved
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
23
7
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
n-butanol
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
2
Severe attack; softened in few hrs
"
9
Resistant over a period of months to years
Terluran; BASF
20 20 n-butyl alcohol
9
"
8
Resistant - no visual change observed
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
50
4
"
Terlux; BASF
23
7
2714
Exposure medium
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
Exp. medium note
% Change
Temp. (°C)
Time (days)
PDL #
Butyl Butyrate
23
7
2
Butyl Chloride
23
7
Butyl Ether
23
Butyraldehyde
Butyric Acid
Conc. (%)
% Retained
Resistance note
Test note
Material note
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2
"
"
"
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
100
23
28
2
"
"
100
52
28
Weight
Elong.
Tensile strength
Impact strength
2
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
2
Not recommended; severe effect
Cycolac; GE Plastics
Butyric Anhydride
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Butyryl Chloride
23
7
2
"
"
"
Cadmium Bromide
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
2715
solution
ABS
Exposure medium
Cadmium Bromide (cont) Caffeine
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
solution
50
9
Resistant over a period of months to years
Terlux; BASF
"
20
9
"
Terluran; BASF
"
20
9
"
Terlux; BASF
saturated
23
8
Resistant - no visual change observed
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
Calcium Bromide
7
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
Calcium Carbonate
Calcium Chlorate Calcium Chloride
2716
Exposure medium
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
100
23
28
9
"
"
100
52
28
9
"
10
23
7
9
No change observed
0.35]0.40
98.1]99.2
Toyolac 900; Toray Industries
10
23
7
9
No noticeable change in appearance
0.4
98
Toyolac 900; Toray Industries; Specimen: Transparent
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
saturated solution
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution
50
9
Resistant over a period of months to years
Terluran; BASF
ABS
23
Calcium Chloride (cont)
Calcium Hydroxide
Calcium Hypochlorite
Calcium Nitrate Calcium Oxide
Exp. medium note
Conc. (%)
Temp. (°C)
solution
50
saturated solution
52
concentrated
Time (days)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
9
Resistant over a period of months to years
Terlux; BASF
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
7
Acceptable; minor effect
Cycolac; GE Plastics
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
52
28
7
"
"
solid
20
9
Resistant over a period of months to years
Terluran; BASF
solution
20
9
"
"
solid
20
9
"
Terlux; BASF
solution
20
9
"
"
powder
23
7
8
Resistant - no visual change observed
saturated solution
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solid
50
9
Resistant over a period of months to years
Terluran; BASF
solution
50
9
"
"
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
solid
50
9
"
Terlux; BASF
solution
50
9
"
"
saturated solution
52
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
9
Plastic was unaffected for duration of test
"
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
23
7
Chemical resistance per ASTM D543
ABS
Exposure medium
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2717
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
Calcium Oxide (cont) Calcium Sulfate
Camphor
crystals
crystals
Caprylic Acid
Caraway Seed
% Retained
Resistance note Weight
5
Questionable; moderate effect
Elong.
Tensile strength
Impact strength
Test note
Material note Cycolac; GE Plastics
25
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
Very slight clouding/ discoloration; expected life: months to years
"
5
Questionable; moderate effect
Cycolac; GE Plastics
20
9
Resistant over a period of months to years
Terluran; BASF
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
5
Moderate resistance-some visual change (discoloration/crazing/ checking) occurs
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
50
9
Resistant over a period of months to years
Terluran; BASF
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
52
28
7
Very slight clouding/ discoloration; expected life: months to years
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ground
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
20
9
"
Terluran; BASF
ABS
Carbazole
% Change PDL #
2718
Exposure medium
Exp. medium note
Conc. (%)
Carbazole (cont)
Carbon Bisulfide Carbon Dioxide
Temp. (°C)
Carbon Tetrachloride wet
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
20
9
Resistant over a period of months to years
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
23
2
Not acceptable
65
2
"
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
23
Carbon Monoxide
Time (days)
7
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
100
23
28
7
100
52
28
7
"
"
100
23
28
2
Severe attack; softened in few hrs
"
100
52
28
2
"
"
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Cycolac; GE Plastics
23
7
2
"
23
7
5
Moderate resistance-some visual change (discoloration/crazing/ checking) occurs
23
7
5
"
Strained in bending fixture
ABS
Exposure medium
" Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Chemical resistance per ASTM D543
"
2719
Exp. medium note
Cardamom
% Retained
PDL #
23
7
1
Unsuitable due to decomposition; swelling; dissolution
Starex; LG Chem
23
7
3
Swollen
Toyolac 100; Toray Industries
23
7
3
"
Toyolac 300; Toray Industries
23
7
3
"
Toyolac 500; Toray Industries
23
7
3
"
Toyolac 600; Toray Industries
23
7
0
Dissolved
Toyolac 900; Toray Industries
23
7
0
"
Toyolac 900; Toray Industries; Specimen: Transparent
wet
50
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
"
75
1
2
"
"
81
2
Sample crazed or cracked
LNP Engineering Plastics; Filler: Glass fiber; Specimen: ASTM D1822 tensile impact samples
81
2
"
LNP Engineering Plastics; Filler: 30% Glass fiber; Specimen: ASTM D1822 tensile impact samples
2
Not recommended; severe effect
Cycolac; GE Plastics
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
20
9
Resistant over a period of months to years
Terluran; BASF
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
ABS
Time (days)
Carbon Tetrachloride (cont)
Carbonil Sulfide
% Change
Temp. (°C)
Conc. (%)
2720
Exposure medium
Exp. medium note
Conc. (%)
Cardamom (cont)
Carnauba Wax
Carrot Juice Castor Oil
Temp. (°C)
Time (days)
Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
9
Resistant over a period of months to years
Terluran; BASF
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
20
9
"
Terluran; BASF
20
9
"
Terlux; BASF
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
9
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
9
Almost no change in either appearance or physical properties
Starex; LG Chem
9
Resistant over a period of months to years
Terluran; BASF
7
50 50
ketchup; Heinz
% Retained
Resistance note
50
23
Catsup
% Change PDL #
"
Terlux; BASF
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
22
1
9
No fail @ 1.2% outer fiber strain
Variable strain bending form
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
23
7
7
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
7
Acceptable; minor effect
Cycolac; GE Plastics
2721
9
100
ABS
Exposure medium
Exp. medium note
Cellosolve
Time (days)
PDL #
2-ethoxyethanol
23
7
2
ethylene glycol monoethyl ether
23
7
100
23
100
52
Cellosolve Acetate
Cellosolve Butyl
Cellosolve Ethyl
Cellosolve Methyl
Cetyl Alcohol
% Retained
Resistance note
Test note
Material note
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2
"
"
"
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
28
2
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
20
1
"
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
20
1
"
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
Weight
Elong.
Tensile strength
Impact strength
50
1
"
Terlux; BASF
20
1
"
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
Cellosolve Propyl
Cesium Bromide
% Change
Temp. (°C)
Conc. (%)
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
ABS
100
2722
Exposure medium
Exp. medium note
Conc. (%)
Cetyl Alcohol (cont)
Temp. (°C)
Time (days)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
Chamomile Extract
20
9
"
Terluran; BASF
9
"
Chicken Soup
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Chlordane
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
20
Chlorinated Lime
50
Chlorine
Terlux; BASF
9
"
Terlux; BASF
in air
10
23
28
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
wet
10
23
28
2
Severe attack; softened in few hrs
"
in air
10
52
28
5
Moderate effect; expected life: weeks to months
"
wet
10
52
28
2
Severe attack; softened in few hrs
"
100
23
28
2
"
"
100
52
28
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
"
20
1
"
Terlux; BASF
wet
23
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
2723
2
liquid or gaseous
1
ABS
Exposure medium
Chlorine (cont)
Exp. medium note
Chlorobenzene
% Retained
Time (days)
PDL #
wet
50
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
liquid or gaseous
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
"
50
wet
75
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
1
"
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
100
23
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
2
"
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
Chlorine Water
Chloroacetic Acid
% Change
Temp. (°C)
Conc. (%)
1
100
23
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
20 23
7
"
2
Exposure stress is the critical stress (level at which part stress cracks)
Terlux; BASF Strained in bending fixture
Cycolac; GE Plastics
ABS
1
2724
Exposure medium
Exp. medium note
Conc. (%)
Chlorobenzene (cont)
% Retained
Time (days)
PDL #
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
50
1
"
Terlux; BASF
2
Not recommended; severe effect
Cycolac; GE Plastics
mono
Chloroform
% Change
Temp. (°C)
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
20
ABS
Exposure medium
1
"
Terlux; BASF
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
4
Softened noticeably
Starex; LG Chem
23
7
0
Dissolved
Toyolac 900; Toray Industries
23
7
0
"
Toyolac 900; Toray Industries; Specimen: Transparent
50
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
2725
Exp. medium note
% Change
% Retained
Temp. (°C)
Time (days)
PDL #
Chloroform (cont)
75
1
2
Poor resistance; loss of mechanical properties; swelling
Chloropropane
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chlorosulfonic Acid
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
7
Acceptable; minor effect
Cycolac; GE Plastics Lastilac; LATI Industria Termoplastici S.p.a.
Conc. (%)
5
Chromic Acid
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note Lastilac; LATI Industria Termoplastici S.p.a.
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
10
23
1
7
Good resistance
20
23
7
8
Resistant - no visual change observed
20
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
20
52
28
7
"
"
50
23
1
5
Fair resistance
Lastilac; LATI Industria Termoplastici S.p.a.
50
23
28
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
50
52
28
5
"
"
5
Questionable; moderate effect
Cycolac; GE Plastics
50
2726
Exposure medium
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
solution
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
"
20
4
"
Terlux; BASF
2
Not acceptable
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
"
50
4
"
Terlux; BASF
65
2
Not acceptable
ABS
23 solution
Exp. medium note
Conc. (%)
Cinammon
Time (days)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
50
4
"
Terluran; BASF
50
4
"
Terlux; BASF
apple
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
Chromosulfuric Acid
Cider
Temp. (°C)
"
50
9
"
"
sticks
20
9
"
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
Cineol
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Cinnamaldehyde
23
7
2
"
"
"
Cinnamic Aldehyde
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
ground
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
Cinnamon
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
10
23
1
7
Good resistance
10
23
7
8
Resistant - no visual change observed
Citraconic Anhydride Citric Acid
Chemical resistance per ASTM D543
ABS
Exposure medium
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Lastilac; LATI Industria Termoplastici S.p.a.
Chemical resistance per ASTM D543
2727
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Exp. medium note
Citric Acid (cont)
% Retained
Time (days)
PDL #
10
23
7
9
No change observed
0.33]0.40
98.2]99.2
Toyolac 900; Toray Industries
10
23
7
9
No noticeable change in appearance
0.4
98
Toyolac 900; Toray Industries; Specimen: Transparent
10
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
10
52
28
7
"
"
20
23
7
8
Resistant - no visual change observed
50
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Chemical resistance per ASTM D543
Material note
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
23
7
9
Almost no change in either appearance or physical properties
Starex; LG Chem
crystals
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
crystals
52
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
5
Questionable; moderate effect
Cycolac; GE Plastics
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
4
Exposure stress is the critical stress (level at which part stress cracks)
Citronella
Clorox
% Change
Temp. (°C)
Conc. (%)
Chlorox
23
28
7
Strained in bending fixture
2728
Exposure medium
Cycolac; GE Plastics
ABS
Exp. medium note
Cloves
PDL #
23
7
8
Surface appearance unchanged; data from Georgia Gulf PVC literature
23
7
9
Data taken from Georgia Gulf PVC literature
Chlorox
23
7
8
Resistant - no visual change observed
"
23
7
86.9
"
23
6
82.9
"
23
7
86.9
"
23
6
82.9
"
81
3
66.6
LNP Engineering Plastics; Filler: Glass fiber; Specimen: ASTM D1822 tensile impact samples
"
81
3
66.6
LNP Engineering Plastics; Filler: 30% Glass fiber; Specimen: ASTM D1822 tensile impact samples
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
20
1
"
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
Coca Cola
% Retained
Time (days)
Clorox (cont)
Clove Oil
% Change
Temp. (°C)
Conc. (%)
Resistance note Weight
0.1
Elong.
110
Tensile strength
Impact strength
Test note
Material note
Flexure; samples placed in 20° bend
Cycolac KJU; GE Plastics
96
ABS
Exposure medium
" Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs LNP Engineering Plastics; Filler: Glass fiber; Specimen: ASTM D1822 tensile impact samples
Flexural stress
" LNP Engineering Plastics; Filler: 30% Glass fiber; Specimen: ASTM D1822 tensile impact samples
Flexural stress
"
"
7
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
Terlux; BASF
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2729
1
23
Exp. medium note
Coca Cola (cont)
extract
Conc. (%)
Cocoa Butter
Coconut Oil
Cod Liver Oil
% Retained
Time (days)
PDL #
23
7
8
Resistant - no visual change observed
20
9
Resistant over a period of months to years
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
5
Questionable; moderate effect
Cycolac; GE Plastics
23
Coffee
% Change
Temp. (°C)
7
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ground
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
cream, sucaryl
2730
Exposure medium
7
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
23
Exp. medium note
Coffee (cont)
Time (days)
PDL #
cream, sugar
23
7
8
dry powder
23
7
liquid
23
7
paste
23
ground
23
"
Material note
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
8
"
"
"
8
"
"
"
7
8
"
"
"
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
"
52
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
28
50
Copper Nitrate Copper Oxide
Resistance note Weight
Elong.
Tensile strength
Impact strength
9
"
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
PAM
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
Crisco
23
7
4
"
"
"
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
25
23
7
8
"
"
"
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
100
23
28
9
"
"
100
52
28
9
"
"
23
7
8
Resistant - no visual change observed
Colloidal Sulfur
Copper Chloride
% Retained Test note
Coffee Extract
Cooking Oils
% Change
Temp. (°C)
Conc. (%)
ABS
Exposure medium
Terlux; BASF
Chemical resistance per ASTM D543
2731
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Exp. medium note
Copper Sulfate
% Retained
Time (days)
PDL #
10
23
1
7
Good resistance
25
23
7
8
Resistant - no visual change observed
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note Lastilac; LATI Industria Termoplastici S.p.a.
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
23
Corn Oil
% Change
Temp. (°C)
Conc. (%)
7
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
Mazola
100
"
100
23
28
52
28
20
9
"
"
9
Resistant over a period of months to years
Terluran; BASF
Mazola
23
7
4
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
"
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
8
"
"
23
8
92.5
"
23
6
83.2
"
23
8
92.5
"
23
6
83.2
50
9
" LNP Engineering Plastics; Filler: Glass fiber; Specimen: ASTM D1822 tensile impact samples
Flexural stress
" LNP Engineering Plastics; Filler: 30% Glass fiber; Specimen: ASTM D1822 tensile impact samples
Flexural stress
" Terluran; BASF
ABS
Mazola
Resistant over a period of months to years
2732
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
Corn Oil (cont) Corn Syrup
Karo
Cottage Cheese Cottonseed Oil
% Retained
Resistance note Weight
5
Questionable; moderate effect
Elong.
Tensile strength
Impact strength
Test note
Material note Cycolac; GE Plastics
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
"
22
1
9
No fail @ 1.2% outer fiber strain
Variable strain bending form
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
with oleic acid
50
21.1
1
6
Exposure strain is critical strain - level where stress cracks first appear
"
"
"
50
22
1
3
"
"
"
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
5
Questionable; moderate effect
Cycolac; GE Plastics
23
Cresol
cresolic compounds
7
Chemical resistance per ASTM D543
7
2
Exposure stress is the critical stress (level at which part stress cracks)
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
2
Not recommended; severe effect
8
Resistant - no visual change observed
23
7
Strained in bending fixture
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
Creme Fish Lure
Crisco
% Change PDL #
ABS
Exposure medium
Chemical resistance per ASTM D543
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Cycolac; GE Plastics
Chemical resistance per ASTM D543
2733
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Exp. medium note
Cuprous Oxide
cutting oils; Trimco
Cyanoacrylate
Loctite
Cyclohexane
% Retained
Time (days)
PDL #
100
23
28
9
100
52
28
9
"
23
7
8
Resistant - no visual change observed
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture "
Curry
Cutting Fluids
% Change
Temp. (°C)
Conc. (%)
7
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Plastic was unaffected for duration of test
Material note Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84 "
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Cycolac; GE Plastics
2
23
23
7
2
"
100
23
28
2
Severe attack; softened in few hrs
100
52
28
2
"
"
9
Resistant over a period of months to years
Terluran; BASF
20 20
2734
Exposure medium
" Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
9
"
Terlux; BASF
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
23
7
8
Resistant - no visual change observed
23
7
9
No noticeable change in appearance
0.25
99
Toyolac Parel TP10; Toray Industries; Specimen: Antistatic
23
7
9
No change observed
0.26
98.4
Toyolac 100; Toray Industries
23
7
9
"
0.26
98.4
Toyolac 300; Toray Industries
23
7
9
"
0.26
98.4
Toyolac 500; Toray Industries
23
7
9
"
0.26
98.4
Toyolac 600; Toray Industries
23
7
5
Slightly whitened
3.00]3.65
85.0]87.5
Toyolac 900; Toray Industries
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
Exp. medium note
Conc. (%)
Cyclohexane (cont)
PDL #
23
7
5
Slightly whitens
2
Not resistant; primarily used as solvent to bond to substrates such as PVC tubing
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
9
Resistant over a period of months to years
Terluran; BASF
50
75
1
1
20 20
Resistance note Weight
3.65
Elong.
Tensile strength
Impact strength
Test note
85
Material note Toyolac 900; Toray Industries; Specimen: Transparent
Tests were conducted on a variable strain fixture which exhibits chemical resistance of a part under stress
Lustran ABS 248; Monsanto
9
"
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
8
"
"
Lustran; Specimen: 50.8 mm (2 in) diameter discs
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
50
50
Cyclohexanone
% Retained
Time (days)
23
Cyclohexanol
% Change
Temp. (°C)
Terlux; BASF
Terluran; BASF
"
Terlux; BASF
23
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
2735
4
100
20
ABS
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
20
Cyclohexanone (cont)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
Lastilac; LATI Industria Termoplastici S.p.a.
23
1
2
Poor resistance; loss of mechanical properties; swelling
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
50
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
50
1
"
Terlux; BASF
75
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
Cyclohexylamine
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Dairy Products
20
9
Resistant over a period of months to years
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
Decahydronaphthalene
Decyl Alcohol
Degreasing Cleaners
metal degreaser; Magnus 105
Chemical resistance per ASTM D543
2736
Exposure medium
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
9
"
Terlux; BASF
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
7
4
Softened noticeably
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Starex; LG Chem
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
ABS
23 23
Exp. medium note
Conc. (%)
Dehydroacetic Acid
Dekalin
Deodorants
Dial
Ban
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
50
4
"
Terluran; BASF
50
4
"
Terlux; BASF
7
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
7
Cycolac; GE Plastics
23
7
4
"
"
"
22
3
8
Resistant - no visual change observed
"
Lustran; Specimen: Bar specimen
22
3
8
"
"
Lustran; Monsanto; Specimen: Bar specimen
7
Acceptable; minor effect
Cycolac
7
"
Cycolac; GE Plastics
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
Not resistant; plastic severely crazed; softened or dissolved
Diacetone Alcohol
23
7
2
100
23
28
2
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
Dibenzyl Ether
1,2-Dibromopropane
Time (days)
20
23
Detergents
Diacetone
Temp. (°C)
Chemical resistance per ASTM D543
ABS
Exposure medium
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2737
Dibutyl Phthalate
Exp. medium note
% Retained
Time (days)
PDL #
100
23
28
2
Severe attack; softened in few hrs
Magnum; Specimen: In accordance with ASTM D543-84
100
23
28
2
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
Magnum; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Specimen: 50.8 mm (2 in) diameter discs
23
7
2
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
Not resistant; plastic severely crazed; softened or dissolved
23
7
2
100
23
28
0
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
23
7
2
Dibutylamine
1,2-Dichlorobenzene
% Change
Temp. (°C)
Conc. (%)
Chemical resistance per ASTM D543
Chemical resistance per ASTM D543
2738
Exposure medium
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
% Change
% Retained
Temp. (°C)
Time (days)
PDL #
1,4-Dichlorobenzene
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Dichlorobenzene
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
1,2-Dichloroethane
Exp. medium note
Conc. (%)
Diethanolamine
Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
100
23
28
2
100
52
28
2
23
7
2
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
8
"
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84 "
2
Not recommended; severe effect
Cycolac; GE Plastics
Softened noticeably
Starex; LG Chem
23
7
4
100
23
28
2
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
100
23
28
9
Plastic was unaffected for duration of test
"
100
52
28
9
"
"
9
Resistant over a period of months to years
Terluran; BASF
Dichloroethane 1,1-Dichloroethylene
Resistance note
20 20
9
"
8
Resistant - no visual change observed
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
23
7
ABS
Exposure medium
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2739
Exp. medium note
PDL #
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Diethyl Hexyl Phthalate
Diethyl Ketone
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
23
7
2
"
23
2
Not acceptable
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
65
2
Not acceptable
20
9
Resistant over a period of months to years
Terluran; BASF
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
50
4
"
Terluran; BASF
50
4
"
Terlux; BASF
20
9
Resistant over a period of months to years
Terluran; BASF
50
Diethyl Phthalate
% Retained
Time (days)
Diethyl Carbonate Diethyl Ether
% Change
Temp. (°C)
Conc. (%)
Chemical resistance per ASTM D543
"
"
"
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
ABS
9
100
20
2740
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
20
Diethyl Phthalate (cont)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
2
Not resistant; plastic severely crazed; softened or dissolved
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
23
7
Terlux; BASF
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Diethylamine
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Diethylene Chloride
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
"
"
Diethylene Dioxide
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
Diethylene Glycol
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
50
1
2
"
"
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
9
Resistant over a period of months to years
Terluran; BASF
2741
75
20
ABS
Exposure medium
Diethylene Glycol (cont)
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
20
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
9
Resistant over a period of months to years
8
Resistant - no visual change observed
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
7
Acceptable; minor effect
2
Not resistant; plastic severely crazed; softened or dissolved
23
7
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Cycolac; GE Plastics
Diisobutyl Ketone
23
Diisodecyl Phthalate
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
20
4
"
Terlux; BASF
50
4
"
Terluran; BASF
50
4
"
Terlux; BASF
20
4
"
Terluran; BASF
20
4
"
Terlux; BASF
50
4
"
Terluran; BASF
50
4
"
Terlux; BASF
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
2
Not resistant; plastic severely crazed; softened or dissolved
Dimethyl Diglycol Phthalate
Dimethyl Phthalate
23
7
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
Dimethyl Sulfate
7
2742
Exposure medium
Exp. medium note
Conc. (%)
Dimethylformamide
Dinonyl Phthalate
Dioctyl Phthalate
1,4-Dioxane
Diphenylamine
Time (days)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
50
4
"
Terluran; BASF
50
4
"
Terlux; BASF
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
2
100
52
28
2
"
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
100
23
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
"
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
Diphenyl Ether
Diphenyl Oxide
Temp. (°C)
ABS
Exposure medium
" Strained in bending fixture
Chemical resistance per ASTM D543
Cycolac; GE Plastics
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
100
23
28
2
"
"
100
52
28
2
"
"
2743
100
Exp. medium note
Conc. (%)
Diphenylamine (cont)
Dipropylene Glycol
Dishwashing Detergents
Time (days)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
9
100
52
28
9
"
Ivory liquid
3
23
7
7
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
Joy liquid
5
23
7
7
"
"
"
"
7
9
"
10
23
Cascade
10
81
3
64.4
LNP Engineering Plastics; Filler: Glass fiber; Specimen: ASTM D1822 tensile impact samples
"
10
81
3
64.4
LNP Engineering Plastics; Filler: 30% Glass fiber; Specimen: ASTM D1822 tensile impact samples
"
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Ivory liquid
23
7
4
"
"
"
Joy liquid
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
9
No change observed
0.52
98.1
Toyolac 100; Toray Industries
23
7
9
"
0.52
98.1
Toyolac 300; Toray Industries
23
7
9
"
0.52
98.1
Toyolac 500; Toray Industries
23
7
9
"
0.52
98.1
Toyolac 600; Toray Industries
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
adhesive
Exposure stress is the critical stress (level at which part stress cracks)
"
Cascade 707 liquid detergent
Distilled Water
Eastman 910
Temp. (°C)
2744
Exposure medium
Strained in bending fixture
Cycolac; GE Plastics
ABS
Exp. medium note
% Retained
Time (days)
PDL #
23
7
9
Almost no change in either appearance or physical properties
90
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
Ethers
Ethyl Acetate
% Change
Temp. (°C)
Conc. (%)
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note Starex; LG Chem
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
85]88
23
28
0
Solvent
"
85]88
52
28
0
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
20
ABS
Exposure medium
1
"
Terlux; BASF
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
23
7
4
Softened noticeably
Starex; LG Chem
23
7
2
Partly dissolved
Toyolac Parel TP10; Toray Industries; Specimen: Antistatic
23
7
3
Swelled and partially solved
Toyolac 100; Toray Industries
23
7
3
"
Toyolac 300; Toray Industries
23
7
3
"
Toyolac 500; Toray Industries
23
7
3
"
Toyolac 600; Toray Industries
23
7
0
Dissolved
Toyolac 900; Toray Industries
23
7
0
"
Toyolac 900; Toray Industries; Specimen: Transparent
50
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
Strained in bending fixture
Cycolac; GE Plastics
2745
Exp. medium note
Conc. (%)
Ethyl Acetate (cont)
Temp. (°C)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
2
Not recommended; severe effect
Cycolac; GE Plastics
2
Not resistant; plastic severely crazed; softened or dissolved
75
23
Ethyl Acetoacetate
Time (days)
1
7
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
40
20
9
Resistant over a period of months to years
Terluran; BASF
40
20
9
"
Terlux; BASF
40
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical
40
23
28
9
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
40
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
40
50
9
Resistant over a period of months to years
Terlux; BASF
40
52
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical
40
52
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
in water
50
22
1
4
Exposure strain is critical strain - level where stress cracks first appear
Variable strain bending form
Lustran; Monsanto
"
50
22
1
4
"
"
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
50
23
7
4
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
50
23
7
9
Almost no change in either appearance or physical properties
Ethyl Alcohol
2746
Exposure medium
Starex; LG Chem
ABS
Ethyl Alcohol (cont)
Exp. medium note
% Change
% Retained
Temp. (°C)
Time (days)
PDL #
50
23
7
9
No change observed
0.46
99.3
Toyolac 100; Toray Industries
50
23
7
9
"
0.46
99.3
Toyolac 300; Toray Industries
50
23
7
9
"
0.46
99.3
Toyolac 500; Toray Industries
50
23
7
9
"
0.46
99.3
Toyolac 600; Toray Industries
50
23
7
9
"
0.48]0.56
102.5]103.6
Toyolac 900; Toray Industries
50
23
7
9
No noticeable change in appearance
0.56
102
"
50
23
7
9
"
0.56
102
Toyolac 900; Toray Industries; Specimen: Transparent
85
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
85
50
1
2
"
"
85
75
1
2
"
"
95
20
9
Resistant over a period of months to years
Terluran; BASF
95
20
9
"
Terlux; BASF
95
23
7
8
Surface appearance unchanged; data from Georgia Gulf PVC literature
95
23
7
2
Data taken from Georgia Gulf PVC literature
95
23
7
9
Almost no change in either appearance or physical properties
Starex; LG Chem
95
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
95
50
4
"
Terlux; BASF
100
22
1
2
Exposure strain is critical strain - level where stress cracks first appear
Variable strain bending form
Lustran; Monsanto
100
22
1
2
"
"
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
Conc. (%)
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Flexure; samples placed in 20° bend 13
221
121
Material note
ABS
Exposure medium
Cycolac KJU; GE Plastics
"
2747
Exp. medium note
% Change
Temp. (°C)
Time (days)
PDL #
23
7
2
2B absolute
23
7
"
23
denaturated "
Ethyl Alcohol (cont)
Conc. (%)
% Retained
Resistance note
Test note
Material note
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto
7
2
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
2
"
"
Lustran; Monsanto
23
7
2
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
7
Slightly whitens
1.2
92
Toyolac Parel TP10; Toray Industries
23
7
8
No change observed
1.29
99.3
Toyolac 100; Toray Industries
23
7
8
"
1.29
99.3
Toyolac 300; Toray Industries
23
7
8
"
1.29
99.3
Toyolac 500; Toray Industries
23
7
8
"
1.29
99.3
Toyolac 600; Toray Industries
23
7
4
Slightly softened and whitened
2.85]4.10
71.5]79.2
Toyolac 900; Toray Industries
Weight
Elong.
Tensile strength
Impact strength
7
3
Softens; whitens
4.1
72
"
7
3
"
4.1
72
Toyolac 900; Toray Industries; Specimen: Transparent
23
7
7
Slightly whitens
1.2
92
Toyolac Parel TP10; Toray Industries; Specimen: Antistatic
absolute
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical
"
23
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
52
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical
"
52
28
2
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
ABS
23 23
2748
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
Ethyl Alcohol (cont) Ethyl Benzoate
Elong.
Tensile strength
Impact strength
Test note
Material note
7
Acceptable; minor effect
Cycolac; GE Plastics
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
28
2
100
52
28
2
"
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
2
"
"
"
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543 "
23
Ethyl Chloroacetate
7
23
7
2
"
100
23
28
2
Severe attack; softened in few hrs
100
52
28
2
"
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
100
23
28
0
Solvent
100
52
28
Ethyl Salicylate
n-ethylaniline
Ethylbenzene
Weight
23
Ethyl Chloride
Ethylaniline
% Retained
Resistance note
100
Ethyl Bromide Ethyl Butyrate
% Change PDL #
ABS
Exposure medium
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs " Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84 "
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
0
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
2749
Exp. medium note
Conc. (%)
Ethylbenzene (cont)
% Change
Temp. (°C)
Time (days)
PDL #
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
50
50
Weight
1
"
8
Resistant - no visual change observed
Elong.
Tensile strength
Impact strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
Terlux; BASF
2-Ethylbutyric Acid
23
Ethylene Chloride
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
Ethylene Chlorohydrin
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
100
23
28
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
Severe attack; softened in few hrs
"
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
23
7
9
Almost no change in either appearance or physical properties
Starex; LG Chem
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
Very slight clouding/ discoloration; expected life: months to years
"
9
Resistant over a period of months to years
Terluran; BASF
Ethylene Glycerol Ethylene Glycol
7
% Retained
Resistance note
20
2750
Exposure medium
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
23
7
8
Resistant - no visual change observed
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
8
"
Chemical resistance per ASTM D543
"
ABS
23
Exp. medium note
Conc. (%)
Ethylene Glycol (cont)
PDL #
23
7
9
No change observed
20.22
99.6
Toyolac 100; Toray Industries
23
7
9
"
20.22
99.6
Toyolac 300; Toray Industries
23
7
9
"
20.22
99.6
Toyolac 500; Toray Industries
23
7
9
"
20.22
99.6
Toyolac 600; Toray Industries
23
7
9
"
20.15 - 20.10
99.1]99.7
Toyolac 900; Toray Industries
23
7
9
No noticeable change in appearance
0.15
99
Toyolac 900; Toray Industries; Specimen: Transparent
23
7
6
Slightly whitens
1.6
90
Toyolac Parel TP10; Toray Industries; Specimen: Antistatic LNP Engineering Plastics; Filler: Glass fiber; Specimen: ASTM D1822 tensile impact samples
12
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
23
9
95.9
23
8
90.8
23
9
95.9
LNP Engineering Plastics; Filler: 30% Glass fiber; Specimen: ASTM D1822 tensile impact samples
23
8
90.8
"
23
8
90.8
50
9
Resistant over a period of months to years
Terluran; BASF
5
Fair resistance
Lastilac; LATI Industria Termoplastici S.p.a.
1
Flexural stress
Flexural stress
"
"
81
6
84.7
LNP Engineering Plastics; Filler: Glass fiber; Specimen: ASTM D1822 tensile impact samples
81
6
84.7
LNP Engineering Plastics; Filler: 30% Glass fiber; Specimen: ASTM D1822 tensile impact samples
49
7
Acceptable; minor effect
6
Tested 6 months after exposure; retains 57% of dart impact
Cycolac; GE Plastics 75
104
120
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Magnum 343; Dow Chemical; Specimen: Preconditioned @ 38°C for 8 hrs, aerated 16 hrs @ 32°C
2751
1 cycle for 6 hours minimum @60%RH; with 88% Freon @ 660 mg/l
% Retained
Time (days)
75
Ethylene Oxide
% Change
Temp. (°C)
ABS
Exposure medium
Ethylene Oxide (cont)
Exp. medium note 5 cycles for 6 hours minimum @60%RH; with 88% Freon @ 660 mg/l
Conc. (%)
Temp. (°C)
Time (days)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
27
98
136
Test note
Material note
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Magnum 343; Dow Chemical; Specimen: Preconditioned @ 38°C for 8 hrs, aerated 16 hrs @ 32°C
12
49
4
Tested 6 months after exposure; retains 45% of dart impact
12
49
5
Residual ethylene oxide level after 7 aeration days - 169
12
49
4
Tested 6 months after exposure; retains 45% of dart impact
27
98
136
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Magnum 343; Dow Chemical; Specimen: Preconditioned @ 38°C for 8 hrs, aerated 16 hrs @ 32°C
12
49
6
Tested 6 months after exposure; retains 57% of dart impact
75
104
120
"
"
12
49
5
Residual ethylene oxide level after 7 aeration days - 169
12
49
6
Tested 2 weeks after exposure; retains 149% of dart impact
45
107
92
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Magnum 9020; Dow Chemical; Specimen: Preconditioned @ 38°C for 8 hrs, aerated 16 hrs @ 32°C
12
49
7
Tested 6 months after exposure; retains 178% of dart impact
63
105
91
"
"
1 cycle for 6 hours minimum @60%RH; with 88% Freon @ 660 mg/l
12
49
7
"
63
105
91
"
"
5 cycles for 6 hours minimum @60%RH; with 88% Freon @ 660 mg/l
12
49
6
Tested 2 weeks after exposure; retains 149% of dart impact
45
107
92
"
"
12
49
8
Residual ethylene oxide level after 7 aeration days - 104
1 cycle for 6 hours minimum @60%RH; with 88% Freon @ 660 mg/l
2752
Exposure medium
Magnum 343; Dow Chemical; Specimen: Extraction done with 100% HPLC acetone, analysis by gas chromatography
Magnum 343; Dow Chemical; Specimen: Extraction done with 100% HPLC acetone, analysis by gas chromatography
Magnum CLR95; Dow Chemical; Specimen: Extraction done with 100% HPLC acetone, analysis by gas chromatography
ABS
Exp. medium note
Ethylene Oxide (cont)
Ethylene Propylene Rubber Ethylenediamine
Eucalyptus Oil
Conc. (%)
Temp. (°C)
Time (days)
% Change PDL #
49
9
Test note
Material note
105
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Magnum CLR95; Dow Chemical; Specimen: Preconditioned @ 38°C for 8 hrs, aerated 16 hrs @ 32°C
119
"
Tensile strength
Impact strength
Tested 2 weeks after exposure
100
101
Weight
12
% Retained
Resistance note Elong.
12
49
8
"
1 cycle for 6 hours minimum @60%RH; with 88% Freon @ 660 mg/l
12
49
8
Residual ethylene oxide level after 7 aeration days - 104
"
12
49
9
Tested 2 weeks after exposure
100
105
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Magnum CLR95; Dow Chemical; Specimen: Preconditioned @ 38°C for 8 hrs, aerated 16 hrs @ 32°C
5 cycles for 6 hours minimum @60%RH; with 88% Freon @ 660 mg/l
12
49
8
"
101
119
"
"
100
23
28
2
Severe attack; softened in few hrs
100
52
28
2
"
"
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
50
1
2
"
"
75
1
2
"
"
23
7
7
Exposure stress is the critical stress (level at which part stress cracks)
100
23
28
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
Severe attack; softened in few hrs
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
50
4
"
Terluran; BASF
Parker Seal E803-70
ABS
Exposure medium
" Magnum CLR95; Dow Chemical; Specimen: Extraction done with 100% HPLC acetone, analysis by gas chromatography
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
Strained in bending fixture
Cycolac; GE Plastics
2753
Exp. medium note
Conc. (%)
% Change PDL #
% Retained
Resistance note Weight
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Elong.
Tensile strength
Impact strength
Test note
Material note Terlux; BASF
Downy
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
"
23
7
8
Surface appearance unchanged; data from Georgia Gulf PVC literature
Flexure; samples placed in 20° bend
Cycolac KJU; GE Plastics
"
23
7
7
Data taken from Georgia Gulf PVC literature
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
23
7
8
Resistant - no visual change observed
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
Very slight clouding/ discoloration; expected life: months to years
"
100
23
28
9
Plastic was unaffected for duration of test
"
100
52
28
7
Very slight clouding/ discoloration; expected life: months to years
"
5
Questionable; moderate effect
Cycolac; GE Plastics
Ferric Chloride
Ferric Nitrate
Ferric Sulfate
Ferrous Chloride
0.5
270
96
"
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
Very slight clouding/ discoloration; expected life: months to years
"
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
8
"
"
"
saturated
25
ABS
Ferrous Sulfate
Time (days)
50
Eucalyptus Oil (cont)
Fabric Softener
Temp. (°C)
2754
Exposure medium
Exp. medium note
Ferrous Sulfate (cont)
Fertilizers
Time (days)
PDL #
100
23
28
9
100
52
28
Elong.
Tensile strength
Impact strength
Test note
Plastic was unaffected for duration of test
Material note Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
9
"
"
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
9
"
Terlux; BASF
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
100
23
28
2
Severe attack; softened in few hrs
"
100
52
28
2
"
"
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
50
1
2
"
"
75
1
2
"
"
lindane
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Kester # 1544
23
8
91.7
"
23
6
80.7
30
20
9
Resistant over a period of months to years
Terluran; BASF
30
20
9
"
Terlux; BASF
30
23
7
8
Resistant - no visual change observed
30
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
30
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
30
50
4
"
Terlux; BASF
Fluorine
Formaldehyde
Weight
20
"
Flux
% Retained
Resistance note
salts
Fluoboric Acid
Fluoronitrobenzene
% Change
Temp. (°C)
Conc. (%)
50
ABS
Exposure medium
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs LNP Engineering Plastics; Specimen: ASTM D1822 tensile impact samples
Flexural stress
Chemical resistance per ASTM D543
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2755
Exp. medium note
Formaldehyde (cont)
formalin
Formalin
Formic Acid
% Change
% Retained
Temp. (°C)
Time (days)
PDL #
30
52
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
37
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
37
23
7
9
No noticeable change in appearance
37
23
28
3
Considerable change; expected life: days
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
37
50
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
37
52
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
37
75
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
23
7
9
Almost no change in either appearance or physical properties
Starex; LG Chem
37
23
7
9
No change observed
0.32
98.8
Toyolac 100; Toray Industries
37
23
7
9
"
0.32
98.8
Toyolac 300; Toray Industries
37
23
7
9
"
0.32
98.8
Toyolac 500; Toray Industries
37
23
7
9
"
0.32
98.8
Toyolac 600; Toray Industries
37
23
7
9
"
0.28]0.35
100.5]101.3
Toyolac 900; Toray Industries
10
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
10
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
10
52
28
7
"
"
25
23
28
5
Moderate effect; expected life: weeks to months
"
25
52
28
5
"
"
Conc. (%)
Resistance note Weight
0.35
Elong.
Tensile strength
100
Impact strength
Test note
Material note
2756
Exposure medium
Toyolac 900; Toray Industries; Specimen: Transparent
ABS
Exp. medium note
Formic Acid (cont)
Formula 409
spray cleaner
Conc. (%)
Temp. (°C)
Time (days)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
40
20
9
Resistant over a period of months to years
Terluran; BASF
40
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
40
50
4
"
Terluran; BASF
40
50
4
"
Terlux; BASF
50
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
50
23
28
3
Considerable change; expected life: days
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
50
52
28
3
"
80
23
7
5
Slightly whitened
5.77
87.6
Toyolac 100; Toray Industries
80
23
7
5
"
5.77
87.6
Toyolac 300; Toray Industries
80
23
7
5
"
5.77
87.6
Toyolac 500; Toray Industries
80
23
7
5
"
5.77
87.6
Toyolac 600; Toray Industries
80
23
7
3
Slightly softened and whitened
14.85]15.56
55.0]60.0
Toyolac 900; Toray Industries
80
23
7
2
Softens; whitens
15.56
55
Toyolac 900; Toray Industries; Specimen: Transparent
85
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
85
20
4
"
Terlux; BASF
85
50
4
"
Terluran; BASF
ABS
Exposure medium
"
Terluran; BASF
85
50
4
"
Terlux; BASF
98]100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
98]100
52
28
2
"
"
23
7
8
Surface appearance unchanged; data from Georgia Gulf PVC literature
Flexure; samples placed in 20° bend
Cycolac KJU; GE Plastics
2757
Exp. medium note
Formula 409 (cont)
spray cleaner
Freon 11
Freon 113
Freon 114
Freon 12
Conc. (%)
% Change
% Retained
Temp. (°C)
Time (days)
PDL #
23
7
6
Data taken from Georgia Gulf PVC literature
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
Resistance note Weight
Elong.
Tensile strength
0.8
424
95
Impact strength
Test note
Material note Cycolac KJU; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Specimen: 50.8 mm (2 in) diameter discs
23
7
2
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
50
4
"
Terlux; BASF
2
Not recommended; severe effect
Cycolac; GE Plastics
2
"
Cycolac
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
50
4
"
Terluran; BASF
50
4
"
Terlux; BASF
20
4
"
Terluran; BASF
20
4
"
Terlux; BASF
50
4
"
Terluran; BASF
50
4
"
Terlux; BASF
20
4
"
Terluran; BASF
20
2758
Exposure medium
4
"
Freon 12:22
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Specimen: 50.8 mm (2 in) diameter discs
Terlux; BASF
"
23
7
8
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
% Change PDL #
% Retained
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
50
4
"
Terlux; BASF
wet
7
Acceptable; minor effect
Cycolac; GE Plastics
"
7
"
Cycolac
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
20
1
"
Terluran; BASF
Freon 12 (cont)
Freon 21
Freon 22
20
1
"
8
Resistant - no visual change observed
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
9
No fail @ 1.2% outer fiber strain
Fuels
2
Poor resistance
RTP 600; RTP Company
2-Furaldehyde
2
Not recommended; severe effect
Cycolac; GE Plastics
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
Freon 12:22
Fruit Juices
23
fruit cocktail
22
Furfural
Furfuryl Alcohol
100
23
7
1
28
ABS
Exposure medium
Terlux; BASF Chemical resistance per ASTM D543
Variable strain bending form
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
2759
Exp. medium note
Conc. (%) 100
Furfuryl Alcohol (cont)
% Retained
Time (days)
PDL #
52
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
20
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
4
"
2
Not resistant; plastic severely crazed; softened or dissolved
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
10 megarads Cobalt 60, tested 1 day stored in dark after exposure
0
ΔE color change of 19
Magnum 343; Dow Chemical
10 megarads Cobalt 60, tested 1 day stored in UV light after exposure
0
"
"
2.5 megarads Cobalt 60, tested 1 day after exposure
2
ΔE color change of 11.5
Magnum 9020; Dow Chemical
2.5 megarads Cobalt 60, tested 1 year stored in dark after exposure
5
Retains 202% of instrumented dart impact energy
60
104
67
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Magnum 9020; Dow Chemical; Specimen: 3.2351 mm (0.12532 in) injection molded discs, ASTM Type I tensile bars
2.5 megarads Cobalt 60, tested 2 weeks stored in dark after exposure
6
ΔE color change of 4.5; retains 216% of dart impact
84
100
72
"
"
23
Gallic Acid
Gamma Radiation
% Change
Temp. (°C)
7
2760
Exposure medium
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
Gamma Radiation (cont)
2.5 megarads Cobalt 60, tested 2 weeks stored in UV light after expos.
6
ΔE color shift - 4.5; storage in light does not affect color change
Magnum 9020; Dow Chemical
2.5 megarads Cobalt 60, tested 35 days stored in dark after exposure
6
ΔE color change of 3.6
"
10 megarads Cobalt 60, tested 1 year stored in dark after exposure
6
Retains 106% of instrumented dart impact energy
73
111
88
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Magnum 343; Dow Chemical; Specimen: 3.2351 mm (0.12532 in) injection molded discs, ASTM Type I tensile bars
10 megarads Cobalt 60, tested 2 weeks stored in dark after exposure
4
ΔE color change of 13.5; retains 117% of dart impact
61
109
80
"
"
10 megarads Cobalt 60, tested 2 weeks stored in UV light after expos.
3
ΔE color shift - 11; property change similar to samples stored in dark
Magnum 343; Dow Chemical
10 megarads Cobalt 60, tested 35 days stored in dark after exposure
3
ΔE color change of 9.7
"
10 megarads Cobalt 60, tested 35 days stored in UV light after expos.
6
ΔE color shift - 3.2; property change similar to samples stored in dark
"
10 megarads Cobalt 60, tested 4 days stored in UV light after exposure
0
ΔE color shift - 17; property change similar to samples stored in dark
"
10 megarads Cobalt 60, tested 6 months stored in dark after exposure
7
Retains 124% of instrumented dart impact energy
PDL #
Resistance note Weight
Elong.
75
Tensile strength
112
Impact strength
96
Test note
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Material note
2761
Magnum 343; Dow Chemical; Specimen: 3.2351 mm (0.12532 in) injection molded discs, ASTM Type I tensile bars
ABS
Time (days)
% Retained
Exp. medium note
Conc. (%)
Temp. (°C)
% Change
Exposure medium
Gamma Radiation (cont)
2.5 megarads Cobalt 60, tested 1 day after exposure
1
ΔE color change of 15
2.5 megarads Cobalt 60, tested 1 year stored in dark after exposure
8
Retains 175% of instrumented dart impact energy
87
109
104
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Magnum 343; Dow Chemical; Specimen: 3.2351 mm (0.12532 in) injection molded discs, ASTM Type I tensile bars
2.5 megarads Cobalt 60, tested 2 weeks stored in dark after exposure
8
ΔE color change of 5; retains 163% of dart impact
97
103
96
"
"
2.5 megarads Cobalt 60, tested 2 weeks stored in UV light after expos.
7
ΔE color shift - 2.6; property change similar to samples stored in dark
Magnum 343; Dow Chemical
2.5 megarads Cobalt 60, tested 35 days stored in dark after exposure
6
ΔE color change of 4
"
2.5 megarads Cobalt 60, tested 35 days stored in UV light after expos.
9
ΔE color shift - 1; property change similar to samples stored in dark
"
2.5 megarads Cobalt 60, tested 4 days stored in UV light after exposure
2
ΔE color shift - 12; property change similar to samples stored in dark
"
2.5 megarads Cobalt 60, tested 6 months stored in dark after exposure
8
Retains 188% of instrumented dart impact energy
10 megarads Cobalt 60, tested 1 day stored in dark after exposure
0
ΔE color change of 18.5
PDL #
Resistance note Weight
Elong.
Tensile strength
Impact strength
Test note
Material note
2762
Time (days)
% Retained
Exp. medium note
Conc. (%)
Temp. (°C)
% Change
Exposure medium
Magnum 343; Dow Chemical
87
106
92
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Magnum 343; Dow Chemical; Specimen: 3.2351 mm (0.12532 in) injection molded discs, ASTM Type I tensile bars Magnum 9020; Dow Chemical
ABS
Time (days)
Gamma Radiation (cont)
10 megarads Cobalt 60, tested 1 year stored in dark after exposure
4
10 megarads Cobalt 60, tested 2 weeks stored in dark after exposure
PDL #
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
% Change
Exposure medium
% Retained
Resistance note
Test note
Material note
44
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Magnum 9020; Dow Chemical; Specimen: 3.2351 mm (0.12532 in) injection molded discs, ASTM Type I tensile bars
45
"
"
Elong.
Tensile strength
Impact strength
Retains 106% of instrumented dart impact energy
60
105
3
ΔE color change of 12.5; retains 159% of dart impact
60
104
10 megarads Cobalt 60, tested 2 weeks stored in UV light after expos.
2
ΔE color shift - 12.5; storage in light doesn't affect color change
Magnum 9020; Dow Chemical
10 megarads Cobalt 60, tested 35 days stored in dark after exposure
4
ΔE color change of 8
"
10 megarads Cobalt 60, tested 35 days stored in UV light after expos.
4
ΔE color shift of 8; storage in light doesn't affect color change
"
10 megarads Cobalt 60, tested 6 months stored in dark after exposure
4
Retains 138% of instrumented dart impact energy
2.5 megarads Cobalt 60, tested 35 days stored in UV light after expos.
6
ΔE color shift - 3.6; storage in light does not affect color change
2.5 megarads Cobalt 60, tested 6 months stored in dark after exposure
4
Retains 183% of instrumented dart impact energy
10 megarads Cobalt 60, tested 1 day after exposure
7
Weight
50
105
42
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Magnum 9020; Dow Chemical; Specimen: 3.2351 mm (0.12532 in) injection molded discs, ASTM Type I tensile bars Magnum 9020; Dow Chemical
60
109
67
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Magnum 9020; Dow Chemical; Specimen: 3.2351 mm (0.12532 in) injection molded discs, ASTM Type I tensile bars Magnum CLR95; Dow Chemical
2763
Gamma Radiation (cont)
10 megarads Cobalt 60, tested 2 weeks stored in dark after exposure
7
10 megarads Cobalt 60, tested 2 weeks stored in UV light after expos.
5
10 megarads Cobalt 60, tested 35 days stored in dark after exposure
7
10 megarads Cobalt 60, tested 35 days stored in UV light after expos.
1
2.5 megarads Cobalt 60, tested 1 day after exposure
7
2.5 megarads Cobalt 60, tested 2 weeks stored in dark after exposure
8
2.5 megarads Cobalt 60, tested 2 weeks stored in UV light after expos.
6
2.5 megarads Cobalt 60, tested 35 days stored in dark after exposure
7
2.5 megarads Cobalt 60, tested 35 days stored in UV light after expos.
6
Storage in light does not affect the bleach-back in optical properties
"
7
Good resistance
RTP 600; RTP Company
PDL #
Resistance note Weight
Storage in light does not affect the bleach-back in optical properties
Elong.
Test note
Material note
77
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Magnum CLR95; Dow Chemical; Specimen: 3.2351 mm (0.12532 in) injection molded discs, ASTM Type I tensile bars
77
"
"
Tensile strength
Impact strength
100
100
2764
Time (days)
% Retained
Exp. medium note
Conc. (%)
Temp. (°C)
% Change
Exposure medium
Magnum CLR95; Dow Chemical
Storage in light does not affect the bleach-back in optical properties
"
"
Storage in light does not affect the bleach-back in optical properties
100
96
Tensile strength per ASTM D638-84; 10 mil notched Izod per ASTM D256-84
Magnum CLR95; Dow Chemical; Specimen: 3.2351 mm (0.12532 in) injection molded discs, ASTM Type I tensile bars
101
88
"
"
Magnum CLR95; Dow Chemical
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Garlic
Gasoline
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
powder
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
regular
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
white
100
23
28
9
"
"
regular
100
52
28
3
Considerable change; expected life: days
"
white
100
52
28
5
Moderate effect; expected life: weeks to months
"
premium unleaded
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
standard unleaded
20
4
"
"
premium unleaded
20
4
"
Terlux; BASF
standard unleaded
20
4
"
"
pure
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Cycolac; GE Plastics
23
7
2
"
ethyl
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
"
23
7
2
"
regular
23
7
2
"
"
23
7
2
"
white gas
23
7
2
"
Strained in bending fixture
" Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Chemical resistance per ASTM D543
" "
Chemical resistance per ASTM D543
" "
2765
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Gasoline (cont)
white gas
Elong.
Tensile strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Impact strength
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
23
7
6
Slight change; but considered acceptable for minimal exposure only
23
7
5
Slightly dark discoloration
3.58
81.8
Toyolac 100; Toray Industries
23
7
5
"
3.58
81.8
Toyolac 300; Toray Industries
23
7
5
"
3.58
81.8
Toyolac 500; Toray Industries
23
7
5
"
3.58
81.8
Toyolac 600; Toray Industries
23
7
5
Slightly black
3.6
82
Toyolac Parel TP10; Toray Industries; Specimen: Antistatic LNP Engineering Plastics; Specimen: ASTM D1822 tensile impact samples
Starex; LG Chem
23
1
29.9
23
1
25.9
pure
50
premium unleaded
"
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
standard unleaded
50
1
"
"
premium unleaded
50
1
"
Terlux; BASF
standard unleaded
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
"
pure
75
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
ground
20
1
Flexural stress
2
81
Ginger
% Retained
1
1
2766
Exposure medium
30.4
LNP Engineering Plastics; Specimen: ASTM D1822 tensile impact samples
Not recommended; severe effect
Cycolac; GE Plastics
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
ABS
2
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Ginger (cont)
Glucose
Test note Elong.
Tensile strength
Material note
Impact strength
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
"
50
4
"
Terluran; BASF
"
50
4
"
Terlux; BASF
Windex
w/ water; D5W
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
4
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
Tests were conducted on a variable strain fixture which exhibits chemical resistance of a part under stress
Lustran ABS 248; Monsanto
5
23
8
Resistant
30
20
9
Resistant over a period of months to years
Terluran; BASF
30
20
9
"
Terlux; BASF
30
23
8
Resistant - no visual change observed
30
50
9
Resistant over a period of months to years
Terluran; BASF
30
50
9
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
7
Acceptable; minor effect
Cycolac; GE Plastics
2
Not recommended; severe effect
"
7
Glues Glycerin
% Retained
ground
Ginger Ale Glass Cleaners
ABS
Exposure medium
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
2767
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Glycerin (cont)
powder
Grape Juice
Test note
Material note
Impact strength
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
9
Almost no change in either appearance or physical properties
23
7
9
No change observed
20.24
99.6
Toyolac 100; Toray Industries
23
7
9
"
20.24
99.6
Toyolac 300; Toray Industries
23
7
9
"
20.24
99.6
Toyolac 500; Toray Industries
23
7
9
"
20.24
99.6
Toyolac 600; Toray Industries
9
Resistant over a period of months to years
Starex; LG Chem
Terluran; BASF
9
"
Terlux; BASF
5
Questionable; moderate effect
Cycolac; GE Plastics
powder
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Cellosolve
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
"
"
23
28
7
Very slight clouding/ discoloration; expected life: months to years
100
100
Grapefruit Juice
Tensile strength
7
50
Glycol Ether
Elong.
23
50
Glycine
% Retained
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
52
28
7
"
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
7
Acceptable; minor effect
"
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
9
Resistant over a period of months to years
Terluran; BASF
20 20 23
7
9
"
7
Exposure stress is the critical stress (level at which part stress cracks)
2768
Exposure medium
" Strained in bending fixture
Cycolac; GE Plastics
Terlux; BASF Strained in bending fixture
Cycolac; GE Plastics
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
23
Grapefruit Juice (cont)
7
ABS
Exposure medium
% Retained Elong.
Tensile strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Impact strength
8
Resistant - no visual change observed
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
9
Exposure stress is the critical stress (level at which part stress cracks)
Cycolac; GE Plastics
23
Gravy
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
beef gravy
Greases
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
Chevron FM
23
7
9
"
"
"
Chevron SMI
23
7
7
"
"
"
23
7
"
Lubriplate 105
Clairol
Hand Lotions Vaseline Intensive Care
Heating Oils
7
Amoco Rykon 2 EP
Gum Tragacanth
Hair Spray
23
7
Strained in bending fixture
Graphite
4
"
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
22
1
9
No fail @ 1.2% outer fiber strain
Variable strain bending form
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
2769
23
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
20
Heptane
4
20
Material note
Impact strength
Terluran; BASF
Limited resistance: some swelling; solvation or environmental stress cracking is possible
4
"
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
23
7
9
Almost no change in either appearance or physical properties
Starex; LG Chem
50
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
50
4
"
Terlux; BASF
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
1
50
9
"
23
7
8
Resistant - no visual change observed
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
Very slight clouding/ discoloration; expected life: months to years
"
Hexachlorophene Hexane
Tensile strength
1
75
Hexachlorobenzene
Test note Elong.
23
50
Heptyl Alcohol
% Retained
2770
Exposure medium
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Hexane (cont)
20
4
20
Hexyl Alcohol
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
Terluran; BASF
Limited resistance: some swelling; solvation or environmental stress cracking is possible
4
"
23
7
7
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
3
Stress cracking observed; data from Georgia Gulf PVC literature
Flexure; samples placed in 20° bend
Cycolac KJU; GE Plastics
23
7
4
Data taken from Georgia Gulf PVC literature
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
2
Not recommended; severe effect
Cycolac; GE Plastics
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
20
9
"
Terluran; BASF
20
9
"
Terlux; BASF
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
50
Hexanetriol
ABS
Exposure medium
50
4
"
2
Not resistant; plastic severely crazed; softened or dissolved
0.8
230
87
" Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Honey
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
7
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2771
Hexyl Ether
23
23
7
Terlux; BASF
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Honey (cont)
Horseradish
Hydrobromic Acid
Tensile strength
Material note
Impact strength
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
7
Acceptable; minor effect
Cycolac; GE Plastics
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
7
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
detergent; solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
Fantastik spray cleaner
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
Formula 409 all purpose cleaner
23
7
2
"
"
"
Pinesol
23
7
2
"
"
"
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
100
52
28
7
"
"
2
Poor resistance
RTP 600; RTP Company Lastilac; LATI Industria Termoplastici S.p.a.
Hydrocarbons Hydrochloric Acid
Test note Elong.
50
23
Household Cleaners
% Retained
2772
Exposure medium
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
10
23
1
7
Good resistance
10
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto
10
23
7
8
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
10
23
7
9
No change observed
0.32
98.8
Toyolac 100; Toray Industries
10
23
7
9
"
0.32
98.8
Toyolac 300; Toray Industries
10
23
7
9
"
0.32
98.8
Toyolac 500; Toray Industries
10
23
7
9
"
0.32
98.8
Toyolac 600; Toray Industries
23
7
9
"
0.20]0.26
98.0]99.5
Toyolac 900; Toray Industries
23
7
9
No noticeable change in appearance
0.26
98
"
10
23
7
9
"
0.26
98
Toyolac 900; Toray Industries; Specimen: Transparent
10
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical
ABS
10 10
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Hydrochloric Acid (cont)
28
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
10
23
10
23
6
80.9
10
23
6
83.7
10
52
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical
10
52
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
10
75
1
5
Fair resistance
Lastilac; LATI Industria Termoplastici S.p.a.
10
81
5
15
20
9
15
20
9
"
Terlux; BASF
15
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
15
50
4
"
Terlux; BASF
20
23
9
Almost no change in either appearance or physical properties
Starex; LG Chem
7
Acceptable; minor effect
Cycolac; GE Plastics
7
20
9
ABS
Exposure medium
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84 LNP Engineering Plastics; Specimen: ASTM D1822 tensile impact samples Flexural stress
76.5
"
LNP Engineering Plastics; Specimen: ASTM D1822 tensile impact samples
Resistant over a period of months to years
Terluran; BASF
Strained in bending fixture
"
25
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
35
23
1
7
Good resistance
35
23
7
8
Slightly whitens
0.72
98
Toyolac 900; Toray Industries
35
23
7
8
"
0.72
98
Toyolac 900; Toray Industries; Specimen: Transparent
35
23
7
7
Slightly whitened
0.60
89.3
Toyolac 100; Toray Industries
35
23
7
7
"
0.60
89.3
Toyolac 300; Toray Industries
35
23
7
7
"
0.60
89.3
Toyolac 500; Toray Industries
Lastilac; LATI Industria Termoplastici S.p.a.
2773
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Hydrochloric Acid (cont)
Tensile strength
Material note
Impact strength
23
7
7
Slightly whitened
0.60
89.3
Toyolac 600; Toray Industries
35
23
7
8
"
0.61]0.72
98.0]99.0
Toyolac 900; Toray Industries
37
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical
37
23
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
37
52
28
7
"
Magnum; Dow Chemical
37
52
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
5
Questionable; moderate effect
Cycolac; GE Plastics
38
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto
38
23
7
8
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
38
23
7
9
Almost no change in either appearance or physical properties
Starex; LG Chem
concentrated
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
"
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
"
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
5
Moderate effect; expected life: weeks to months
"
10
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
ABS
Hydrofluoric Acid
Test note Elong.
35
37
Hydrocyanic Acid
% Retained
2774
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Hydrofluoric Acid (cont)
Hydrofluorosilicic Acid
Hydrogen
Hydrogen Peroxide
23
40
7
% Retained Elong.
Tensile strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Impact strength
8
Resistant - no visual change observed
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
40
20
4
"
Terlux; BASF
40
50
4
"
Terluran; BASF
40
50
4
"
Terlux; BASF
48
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
50
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
5
Moderate effect; expected life: weeks to months
"
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
100
52
28
7
"
"
100
23
28
9
Plastic was unaffected for duration of test
"
100
52
28
9
"
"
1
23
28
9
"
"
1
52
28
9
"
"
3
20
9
Resistant over a period of months to years
Terluran; BASF
3
20
9
"
Terlux; BASF
3
23
7
8
Resistant - no visual change observed
3
23
7
9
Almost no change in either appearance or physical properties
3
23
7
9
No noticeable change in appearance
0.44
96
Toyolac 900; Toray Industries; Specimen: Transparent
3
23
7
8
Slightly whitened
0.51
98.1
Toyolac 100; Toray Industries
Chemical resistance per ASTM D543
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Starex; LG Chem
2775
aq.
25
ABS
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Hydrogen Peroxide (cont)
Hydrogen Sulfide
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
aq.
3
23
7
8
Slightly whitened
0.51
98.1
Toyolac 300; Toray Industries
"
3
23
7
8
"
0.51
98.1
Toyolac 500; Toray Industries
"
3
23
7
8
"
0.51
98.1
Toyolac 600; Toray Industries
0.35]0.44
96.0]97.2
Toyolac 900; Toray Industries
3
23
7
9
No change observed
3
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
3
50
9
Resistant over a period of months to years
Terluran; BASF
3
50
9
"
Terlux; BASF
3
52
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
30
20
9
Resistant over a period of months to years
Terluran; BASF
30
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
30
23
1
5
Fair resistance
Lastilac; LATI Industria Termoplastici S.p.a.
30
23
28
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
30
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
30
52
28
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
90
23
28
5
"
"
90
52
28
28
2776
Exposure medium
5
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
23
8
Excellent resistance - no recognizable attack
65
8
"
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Hydroquinone
Test note Elong.
Tensile strength
Material note
Impact strength
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
powder
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
saturated solution
23
28
7
"
"
solution
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
"
50
4
"
Terlux; BASF
powder
52
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
saturated solution
52
28
3
Considerable change; expected life: days
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
50
4
"
"
Hypochlorous Acid
Insect Spray
% Retained
solution
Hydroxyacetone
Inks
ABS
Exposure medium
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
writing
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
Porlon
23
2
Exposure stress is the critical stress (level at which part stress cracks)
writing
50
9
Resistant over a period of months to years
7
Strained in bending fixture
Cycolac; GE Plastics
Terluran; BASF
50
9
"
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
Terlux; BASF
Ortho Isotex
23
7
2
"
"
"
2777
" Johnsons No Roach
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Iodine
Iron (II) Sulfate
Iron (III) Chloride
Test note Elong.
Tensile strength
Material note
Impact strength
crystals
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
2
"
"
tincture
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
"
20
4
"
Terlux; BASF
solution
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
USP, tincture
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
solution
50
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
"
75
1
2
"
"
2
Not recommended; severe effect
Cycolac; GE Plastics
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
solid
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
solution
20
9
"
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
20
9
"
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
Iron Ammonium (II) Sulfate
Iron Dichloride
% Retained
2778
Exposure medium
20
9
"
Terluran; BASF
20
9
"
"
solid
20
9
"
Terlux; BASF
ABS
solid solution
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Iron Dichloride (cont)
Iron Nitrate
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
solution
20
9
Resistant over a period of months to years
Terlux; BASF
solid
50
9
"
Terluran; BASF
solution
50
9
"
"
solid
50
9
"
Terlux; BASF
solution
50
9
"
"
"
20
9
"
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
Isoamyl Acetate
Isoamyl Alcohol
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
23
7
4
Softened noticeably
Starex; LG Chem
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
50
4
"
Terlux; BASF
23
7
4
Softened noticeably
Starex; LG Chem
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
5
Moderate effect; expected life: weeks to months
"
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
Isobutyl Acetate Isobutyl Alcohol
ABS
Exposure medium
20
20 23 50
7
"
8
Resistant - no visual change observed
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
2779
4
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Isobutyl Alcohol (cont)
50
Isobutyronitrile
23
7
100
23
100
52
Isooctane
Tensile strength
Material note
Impact strength
Terlux; BASF
Limited resistance: some swelling; solvation or environmental stress cracking is possible
7
Acceptable; minor effect
2
Not resistant; plastic severely crazed; softened or dissolved
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
28
2
Severe attack; softened in few hrs
"
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
Cycolac; GE Plastics Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
2
Not resistant; plastic severely crazed; softened or dissolved
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF Cycolac; GE Plastics
23
Isopropyl Alcohol
Test note Elong.
4
20
Isopropyl Acetate
% Retained
7
isopropanol
50
23
7
4
Exposure stress is the critical stress (level at which part stress cracks)
"
50
23
7
4
"
2780
Exposure medium
Chemical resistance per ASTM D543
Strained in bending fixture
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
"
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
95
Isopropyl Alcohol (cont)
0.042
1
Data from Novacor Zylar brochure
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
20
Specimen: Transparent
isopropanol
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
2
Severe attack; softened in few hrs
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
9
Resistant over a period of months to years
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
23
1
5
Fair resistance
Lastilac; LATI Industria Termoplastici S.p.a.
isopropanol
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Cycolac; GE Plastics
"
23
7
2
"
23
7
8
Resistant - no visual change observed
23
7
8
"
23
7
9
No noticeable change in appearance
0.3
97
Toyolac 900; Toray Industries; Specimen: Transparent
23
7
9
No change observed
0.26]0.30
97.0]98.0
Toyolac 900; Toray Industries
50
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
isopropanol
75
1
Strained in bending fixture
" Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Chemical resistance per ASTM D543
"
2781
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Kerosene
Kraton
Lactic Acid
Elong.
Tensile strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Impact strength
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
100
23
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
"
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
100
52
28
7
"
"
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
23
7
4
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
9
Almost no change in either appearance or physical properties
23
7
9
No change observed
0.07
98.8
Toyolac 100; Toray Industries
23
7
9
"
0.07
98.8
Toyolac 300; Toray Industries
23
7
9
"
0.07
98.8
Toyolac 500; Toray Industries
23
7
9
"
0.07
98.8
Toyolac 600; Toray Industries
7
Acceptable; minor effect
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
Isopropyl Amine Isopropylbenzene
% Retained
Shell
Starex; LG Chem
Cycolac; GE Plastics Strained in bending fixture
"
20
9
Resistant over a period of months to years
Terluran; BASF
10
20
9
"
Terlux; BASF
10
23
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
10
50
9
Resistant over a period of months to years
Terluran; BASF
10
50
9
"
Terlux; BASF
10
52
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
28
ABS
10
28
2782
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Lactic Acid (cont)
Lactose
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
80
20
9
Resistant over a period of months to years
Terluran; BASF
80
20
9
"
Terlux; BASF
80
50
9
"
Terluran; BASF
80
50
9
"
Terlux; BASF
85
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
85
52
28
9
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
Lanolin
Lard
ABS
Exposure medium
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
5
Questionable; moderate effect
Cycolac; GE Plastics
7
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture "
animal fat
Laundry Detergents
Woolite
1
Tide
3
9
"
Laurel
ground
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
Lauryl Alcohol
23
7
23
7
50
"
"
9
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
2783
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Lauryl Alcohol (cont)
Lauryl Sulfate
Lead Acetate
Test note Elong.
Tensile strength
Material note
Impact strength
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
saturated
23
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
saturated
52
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
9
Plastic was unaffected for duration of test
"
100
52
28
Lead Nitrate
28
9
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
20
9
"
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
solution
20
9
"
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
Lead Stearate
Lead Sulfate
% Retained
2784
Exposure medium
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Lemon Grass Oil
Lemon Juice
Material note
Impact strength
Terluran; BASF
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
9
Resistant over a period of months to years
23
7
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
9
"
Terlux; BASF
100
23
28
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
3
Considerable change; expected life: days
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
50
4
"
Terluran; BASF
50
4
"
Terlux; BASF
2
23
6
2
23
3
23
7
4
23
7
2
"
"
"
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
81.2
3
62 Exposure stress is the critical stress (level at which part stress cracks)
LNP Engineering Plastics; Specimen: ASTM D1822 tensile impact samples Flexural stress
"
Strained in bending fixture
Cycolac; GE Plastics
2785
Lighter Fluid
Tensile strength
1
50
naphtha
Test note Elong.
20
50
Lestoil
% Retained
100
fresh
Lemon Oil
ABS
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Ligroin
Lime Juice
Test note Elong.
Tensile strength
Material note
Impact strength
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
concentrated
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
52
28
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
50
9
Resistant over a period of months to years
Terluran; BASF
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
Lime Water
Lindane
% Retained
g-benzene hexachloride
Linseed Oil
raw
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
23
7
Chemical resistance per ASTM D543
Chemical resistance per ASTM D543 95.3
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
9
23
6
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
83.9
2786
Exposure medium
LNP Engineering Plastics; Specimen: ASTM D1822 tensile impact samples Flexural stress
"
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
81
Linseed Oil (cont)
Lipids
fatty
23
Machining Oils
Tensile strength
Material note
Impact strength
79.8
LNP Engineering Plastics; Specimen: ASTM D1822 tensile impact samples
5
Questionable; moderate effect
Cycolac; GE Plastics
8
Resistant
Tests were conducted on a variable strain fixture which exhibits chemical resistance of a part under stress
Lustran ABS 248; Monsanto
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
8
Resistant - no visual change observed
saturated
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
52
28
7
"
"
7
Acceptable; minor effect
Cycolac; GE Plastics
Sunoco Sunvis 931
2,4-Lutidine
Mace
Test note Elong.
7
Lubricants Lubricating Oils
% Retained
23
Liquid Wrench Lithium Bromide
5
ABS
Exposure medium
23
7
4
Exposure stress is the critical stress (level at which part stress cracks)
23
7
9
Almost no change in either appearance or physical properties
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
Strained in bending fixture
"
Starex; LG Chem
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ground
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
50
4
"
23
7
8
Resistant - no visual change observed
No. 120
23
7
9
Almost no change in either appearance or physical properties
23
7
9
No change observed
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Starex; LG Chem
0.02
98.8
Toyolac 600; Toray Industries
2787
" light
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Machining Oils (cont)
100
Magnesium Bromide
100
100
Magnesium Carbonate
100
Test note Elong.
Tensile strength
Material note
Impact strength
23
7
9
No noticeable change in appearance
0.08
102
Toyolac 900; Toray Industries; Specimen: Transparent
23
7
9
No change observed
0.02
98.8
Toyolac 100; Toray Industries
23
7
9
"
0.02
98.8
Toyolac 300; Toray Industries
23
7
9
"
0.02
98.8
Toyolac 500; Toray Industries
23
7
9
"
20.08 20.05
102.0]104.0
Toyolac 900; Toray Industries
23
7
9
No noticeable change in appearance
99
Toyolac Parel TP10; Toray Industries; Specimen: Antistatic
23
28
7
Very slight clouding/ discoloration; expected life: months to years
52
28
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
23
28
52
28
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
Magnesium Chloride
% Retained
2788
Exposure medium
9
"
Terlux; BASF
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Magnesium Hydroxide
Magnesium Iodide Magnesium Nitrate Magnesium Sulfate
Mandarin Orange Oil
Test note Elong.
Tensile strength
Material note
Impact strength
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
100
23
28
7
"
"
100
52
28
7
"
"
100
23
28
7
"
"
100
52
28
7
"
"
100
23
28
7
"
"
100
52
28
7
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
20
9
"
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
Malic Acid
% Retained
100
Maize Oil
Maleic Acid
ABS
Exposure medium
9
"
Terlux; BASF
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
10
20
9
Resistant over a period of months to years
Terluran; BASF
10
20
9
"
Terlux; BASF
10
50
9
"
Terluran; BASF
10
50
9
"
Terlux; BASF
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
50
4
"
Terluran; BASF
50
4
"
Terlux; BASF
2789
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Mannitol Alcohol
Marjoram
ground
Mayonnaise
Tensile strength
Material note
Impact strength
23
28
3
Considerable change; expected life: days
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
Severe attack; softened in few hrs
"
23
7
8
Resistant - no visual change observed
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
7
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
20
9
"
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
20
9
"
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
7
Exposure stress is the critical stress (level at which part stress cracks)
9
Resistant over a period of months to years
Marmelade
Mascara
Test note Elong.
100
Maple Syrup Margarine
% Retained
Maybelline
23
7
20 20 22
1
9
"
5
Exposure strain is critical strain - level where stress cracks first appear
2790
Exposure medium
Strained in bending fixture
Cycolac; GE Plastics
Terluran; BASF Terlux; BASF Variable strain bending form
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
23
Mayonnaise (cont)
23
m-Cresol
Menthol
Acceptable; minor effect
2
Exposure stress is the critical stress (level at which part stress cracks)
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Impact strength
Cycolac; GE Plastics Strained in bending fixture
"
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
"
10
20
4
"
Terlux; BASF
"
10
50
4
"
Terluran; BASF
"
10
50
4
"
Terlux; BASF
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
9
"
Terlux; BASF
100
50 23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
23
7
8
Resistant - no visual change observed
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
100
23
28
7
"
"
100
52
28
Mercury
100
" Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
23
28
2791
Mesityl Oxide
7
Tensile strength
20
Mercurochrome
Mercurous Nitrate
Resistant - no visual change observed
Elong.
10
"
Mercurous Chloride
7
8
% Retained
in ethanol
Mercuric Chloride
Mercuric Cyanide
7
ABS
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Mesityl Oxide (cont)
100
52
Test note Elong.
Tensile strength
Material note
Impact strength
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
2
Not resistant; plastic severely crazed; softened or dissolved
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
23
28
% Retained
7
50
50
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
1
"
Metalub 555
23
7
7
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
2-Methoxyethanol
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
82
23
28
2
"
"
82
52
28
2
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
2
Not recommended; severe effect
Cycolac; GE Plastics
2
Not resistant; plastic severely crazed; softened or dissolved
Methoxyethyl Oleate
Methyl Acetate
Methyl Acetophonone
23
7
2792
Exposure medium
Terlux; BASF
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Methyl Alcohol
100
23
28
100
23
28
100
52
28
100
52
28
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84 3
Considerable change; expected life: days
" "
2
Severe attack; softened in few hrs
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
1
23
7
23
7
23
7
23
7
2
23
7
2
23
7
3
23
7
1
23
7
1
23
7
2
23
7
3
23
7
2
23
7
3
23
7
2
23
7
3
2
Exposure stress is the critical stress (level at which part stress cracks)
Not resistant; plastic severely crazed; softened or dissolved
Slightly softened and whitened
Softens; whitens
Slightly softened and whitened
Slightly softened and whitened
Slightly softened and whitened
Strained in bending fixture
Cycolac; GE Plastics
"
"
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
"
"
8.57
71.3
Toyolac 600; Toray Industries
8.57
71.3
"
13.1
33
Toyolac 900; Toray Industries; Specimen: Transparent
13.1
33
"
8.57
71.3
Toyolac 100; Toray Industries
8.57
71.3
"
8.57
71.3
Toyolac 300; Toray Industries
8.57
71.3
"
8.57
71.3
Toyolac 500; Toray Industries
8.57
71.3
"
2793
23
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Methyl Alcohol (cont)
23
7
1
23
7
2
23
Slightly softened and whitened
3
23
1
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
10.3]13.1
33.0]37.0
Toyolac 900; Toray Industries
10.3]13.1
33.0]37.0
"
67.1
LNP Engineering Plastics; Specimen: ASTM D1822 tensile impact samples
38.2
Flexural stress
"
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
65
3
50
75
1
1
2794
Exposure medium
67.1
LNP Engineering Plastics; Specimen: ASTM D1822 tensile impact samples Lastilac; LATI Industria Termoplastici S.p.a.
2
Poor resistance; loss of mechanical properties; swelling
2
Not recommended; severe effect
"
Cycolac; GE Plastics
Methyl Amyl Alcohol
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Methyl Benzoate Methyl Bromide
Methyl Bromoacetate Methyl Butyl Alcohol
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
2
"
"
100
23
28
2
"
"
100
52
28
2
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
ABS
liquid @ 20 psi
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
50
Methyl Butyl Alcohol (cont)
4
50
Methyl Chloride
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
Terluran; BASF
Limited resistance: some swelling; solvation or environmental stress cracking is possible
4
"
Terlux; BASF
liquid @ 65%
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
2
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
Methyl Ethyl Ketone
ABS
Exposure medium
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
100
23
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF Lastilac; LATI Industria Termoplastici S.p.a.
23
1
2
Poor resistance; loss of mechanical properties; swelling
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
3
Swelled and partially solved
Toyolac 600; Toray Industries
23
7
3
"
Toyolac 100; Toray Industries
23
7
3
"
Toyolac 300; Toray Industries
23
7
3
"
Toyolac 500; Toray Industries
23
7
0
Dissolved
Toyolac 900; Toray Industries
2795
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Methyl Ethyl Ketone (cont)
Tensile strength
Material note
Impact strength
7
0
Dissolved
Toyolac 900; Toray Industries; Specimen: Transparent
23
7
2
Partly dissolved
Toyolac Parel TP10; Toray Industries; Specimen: Antistatic
2
Not resistant; primarily used as solvent to bond to substrates such as PVC tubing
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
2
Not recommended; severe effect
Cycolac; GE Plastics
50
75
Methyl Isobutyl Ketone
Test note Elong.
23
23
Methyl Eugenol
% Retained
1
1
2796
Exposure medium
Tests were conducted on a variable strain fixture which exhibits chemical resistance of a part under stress
Lustran ABS 248; Monsanto
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
100
23
28
0
Solvent
Magnum; Specimen: In accordance with ASTM D543-84
100
23
28
0
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
Magnum; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
ABS
100
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Methyl Isobutyl Ketone (cont)
Methyl Isopropyl Ketone
Methyl Salicylate
% Retained Elong.
Tensile strength
Test note
Material note
Impact strength
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac
23
7
2
"
"
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Specimen: 50.8 mm (2 in) diameter discs
23
7
2
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
2
Not recommended; severe effect
Cycolac
2
"
Cycolac; GE Plastics
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
7
2
Not resistant; plastic severely crazed; softened or dissolved
100
23
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2797
23
Methyl Laurate Methyl Propyl Ketone
ABS
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
100
Methyl Salicylate (cont)
52
28
Methylcyclohexane
Test note Elong.
Tensile strength
Material note
Impact strength
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
Methylal
% Retained
1
"
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
conc. formaldehyde
23
28
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Methylene Bromide
100
100
52
28
2
"
"
Methylene Chloride
100
23
28
2
"
"
100
52
28
2
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
20 23
1
50
1
50
2798
Exposure medium
1
"
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
"
"
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
ABS
2 1
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
50
Methylene Chloride (cont)
Methylene Chlorobromide
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
75
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
100
52
28
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
powder
20
9
"
"
powder; moisture
20
9
"
"
20
9
"
Terlux; BASF
powder
20
9
"
"
powder; moisture
20
9
"
"
Methylene Iodide
Milk
22
1
4
Embrittlement only at air/ milk interface (fat)
Variable strain bending form
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
23
7
7
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
2799
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
% Retained Elong.
Tensile strength
Test note
Material note
Impact strength
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
paste
23
7
8
"
"
"
powdered
23
7
"
Milk (cont)
8
"
50
9
Resistant over a period of months to years
Terluran; BASF
"
powder
50
9
"
"
powder; moisture
50
9
"
"
50
9
"
Terlux; BASF
powder
50
9
"
"
powder; moisture
50
9
"
"
7
Acceptable; minor effect
Cycolac; GE Plastics
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Mineral Spirits
23
7
8
"
"
"
m-Nitrotoluene
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
"
"
Molasses
22
1
9
No fail @ 1.2% outer fiber strain
Variable strain bending form
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
Monoamyl Phthalate
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
Mineral Oils
Morpholine
2800
Exposure medium
Terluran; BASF
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Moth Flakes
23
Motor Oils
% Retained Elong.
Tensile strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Impact strength
8
Resistant - no visual change observed
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
electric motor oils; Costan 338
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
Extra Heavy Mobil
23
7
9
"
"
"
RPM
23
7
4
"
"
"
Essolube, Tydol
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
No. 30
23
7
9
Almost no change in either appearance or physical properties
23
7
9
"
No. 40
23
7
23
6
50
9
Resistant over a period of months to years
50
9
"
81
5
Starex; LG Chem
" 85.5
83.7
LNP Engineering Plastics; Specimen: ASTM D1822 tensile impact samples Flexural stress
" Terluran; BASF Terlux; BASF
77.7
LNP Engineering Plastics; Specimen: ASTM D1822 tensile impact samples
1
6
Exposure strain is critical strain - level where stress cracks first appear
Variable strain bending form
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
23
7
4
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
Very slight clouding/ discoloration; expected life: months to years
"
9
Resistant over a period of months to years
Terluran; BASF
Scope
20
2801
22
Mouthwash
Mustard
7
ABS
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
20
Mustard (cont)
French's
9
Resistant over a period of months to years
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
Terlux; BASF
22
1
6
Exposure strain is critical strain - level where stress cracks first appear
Variable strain bending form
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
23
7
7
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
7
Acceptable; minor effect
Cycolac; GE Plastics
N,N-Diethyl-mToluidine
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
N,N-Dimethylaniline
23
7
2
"
"
"
100
23
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
"
VM&P
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Specimen: In accordance with ASTM D543-84
"
100
23
28
9
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
2
Severe attack; softened in few hrs
Magnum; Specimen: In accordance with ASTM D543-84
"
100
52
28
2
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
"
23
7
2
"
"
Cycolac; GE Plastics
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Specimen: 50.8 mm (2 in) diameter discs
23
7
8
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
N,N-Dimethylformamide
Naphtha
2802
Exposure medium
Strained in bending fixture
Cycolac
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Naphtha (cont) Naphthalene
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
5
Questionable; moderate effect
Cycolac
5
"
Cycolac; GE Plastics
solution in ethanol
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
"
20
9
Resistant over a period of months to years
"
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
"
20
9
Resistant over a period of months to years
"
crystals
23
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution in ethanol
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
"
50
1
"
Terlux; BASF
crystals
52
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
100
52
28
7
"
"
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
2
"
"
100
52
28
2
"
"
100
52
28
2
"
"
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
8
"
"
"
Natural Gas
n-Heptane
n-heptane
n-heptane
Strained in bending fixture
Cycolac; GE Plastics
2803
n-heptane
28
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
n-Heptane (cont)
n-heptane
Nickel Chloride
Nickel Nitrate Nickel Sulfate
Nitric Acid
% Retained Test note Elong.
Tensile strength
Material note
2804
Exposure medium
Impact strength
23
7
9
No change observed
0.10
98.8
Toyolac 600; Toray Industries
23
7
9
"
0.10
98.8
Toyolac 500; Toray Industries
23
7
9
"
0.10
98.8
Toyolac 100; Toray Industries
23
7
9
"
0.10
98.8
Toyolac 300; Toray Industries
23
7
8
Slightly whitened
0.28]0.35
104.0]106.0
Toyolac 900; Toray Industries
23
7
8
Slightly whitens
0.35
104
Toyolac 900; Toray Industries; Specimen: Transparent
23
7
0.35
104
"
LNP Engineering Plastics; Specimen: ASTM D1822 tensile impact samples
8
"
23
5
Fair - limited use
23
8
90.1
23
7
88.1
65
2
Not acceptable
5
Questionable; moderate effect
Cycolac; GE Plastics
Flexural stress
"
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
100
23
28
9
"
"
100
52
28
9
"
"
30
20
9
Resistant over a period of months to years
Terluran; BASF
30
20
9
"
Terlux; BASF
30
50
9
"
Terluran; BASF
30
50
9
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
5
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
5
52
28
7
"
"
10
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Nitric Acid (cont)
soln.
soln.
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
Starex; LG Chem
10
23
7
9
Almost no change in either appearance or physical properties
10
23
7
9
No change observed
0.45
98.9
Toyolac 600; Toray Industries
10
23
7
9
"
0.45
98.9
Toyolac 500; Toray Industries
10
23
7
9
"
0.45
98.9
Toyolac 100; Toray Industries
10
23
7
9
"
0.45
98.9
Toyolac 300; Toray Industries
10
23
7
9
"
0.33]0.38
101.5]103.7
Toyolac 900; Toray Industries
10
23
7
9
No noticeable change in appearance
0.38
102
Toyolac 900; Toray Industries; Specimen: Transparent
10
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
10
52
28
3
Considerable change; expected life: days
"
5
Questionable; moderate effect
Cycolac; GE Plastics Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
10 20
23
7
8
Resistant - no visual change observed
20
23
7
8
"
20
23
7
9
Almost no change in either appearance or physical properties
Starex; LG Chem
2
Not recommended; severe effect
Cycolac; GE Plastics "
20
Chemical resistance per ASTM D543
"
25
23
7
7
Exposure stress is the critical stress (level at which part stress cracks)
25
23
7
7
"
30
23
28
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
30
52
28
3
Considerable change; expected life: days
"
35
23
1
5
Fair resistance
Lastilac; LATI Industria Termoplastici S.p.a.
35
50
1
2
Poor resistance; loss of mechanical properties; swelling
"
Strained in bending fixture
"
2805
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Nitric Acid (cont)
soln.
Test note Elong.
Tensile strength
Material note
Impact strength
Lastilac; LATI Industria Termoplastici S.p.a.
35
75
1
2
Poor resistance; loss of mechanical properties; swelling
40
23
7
8
Slightly yellowish discoloration
0.73
98.1
Toyolac 600; Toray Industries
40
23
7
8
"
0.73
98.1
Toyolac 500; Toray Industries
40
23
7
8
"
0.73
98.1
Toyolac 100; Toray Industries
40
23
7
8
"
0.73
98.1
40
23
7
6
"
1.25]1.50
40
23
7
7
Slightly yellowed
1.5
102
Toyolac 900; Toray Industries; Specimen: Transparent
40
23
7
5
"
3.1
83
Toyolac Parel TP10; Toray Industries; Specimen: Antistatic
2
Not recommended; severe effect
Cycolac; GE Plastics
50
Toyolac 300; Toray Industries Toyolac 900; Toray Industries
65
23
28
3
Considerable change; expected life: days
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
65
52
28
2
Severe attack; softened in few hrs
"
70
23
7
8
Resistant - no visual change observed
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
70
23
7
8
"
concentrated
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
"
50
4
"
Terluran; BASF
"
50
4
"
Terlux; BASF
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20 concentrated
% Retained
23
7
2806
Exposure medium
Chemical resistance per ASTM D543
"
1
"
Terlux; BASF
2
Not resistant; plastic severely crazed; softened or dissolved
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Nitric Acid (cont)
% Retained Elong.
Tensile strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Impact strength
concentrated
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
"
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
2
Not recommended; severe effect
Cycolac; GE Plastics
concentrated
52
28
concd.
Nitrobenzene
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
dark; ground
20
"
20 23
Nitroglycerin
ABS
Exposure medium
7
1
"
2
Not resistant; plastic severely crazed; softened or dissolved
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
dark; ground
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
"
50
1
"
Terlux; BASF
2
Not recommended; severe effect
Cycolac; GE Plastics
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
Severe attack; softened in few hrs
"
2807
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Elong.
Tensile strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Impact strength
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
100
23
28
2
"
"
100
52
28
2
"
"
n-nonanol
100
23
28
9
Plastic was unaffected for duration of test
"
"
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
50
9
Resistant over a period of months to years
Terluran; BASF
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
2
Not resistant; plastic severely crazed; softened or dissolved
2
Not recommended; severe effect
8
Resistant - no visual change observed
Nitromethane
Nitrosyl Chloride
Nitrous Acid Nonyl Alcohol
% Retained
23
n-Pentane
7
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Cycolac; GE Plastics
Nujol
23
Nutmeg
20
9
Resistant over a period of months to years
Terluran; BASF
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
"
20
9
Resistant over a period of months to years
Terlux; BASF
light; ground
7
2808
Exposure medium
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Nutmeg (cont)
"
Terluran; BASF
"
"
"
Terlux; BASF
50 50
4 4
"
"
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
n-octane
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
2
"
"
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Octanoyl Chloride Octyl Alcohol
Material note
Impact strength
4
50 light; ground
o-Chlorobenzaldehyde Octane
Tensile strength
4
4
50
Test note Elong.
Terlux; BASF
20
light; ground
% Retained
Limited resistance: some swelling; solvation or environmental stress cracking is possible
light; ground
Nutmeg Oil
ABS
Exposure medium
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
7
Very slight clouding/ discoloration; expected life: months to years
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
2809
n-octanol
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
23
Octyl Alcohol (cont)
Octyl Cresol
Elong.
Tensile strength
Test note
Material note
Strained in bending fixture
Cycolac; GE Plastics
Impact strength
2
Exposure stress is the critical stress (level at which part stress cracks)
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
2
100
52
28
2
"
"
23
7
4
Softened noticeably
Starex; LG Chem
9
Resistant over a period of months to years
Terluran; BASF
o-Dichlorobenzene Oils
7
% Retained
diesel
20
"
20
9
"
Mobil DTE 26
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
Mobil S126
23
7
9
"
"
"
cylinder; No. 20
23
7
9
Almost no change in either appearance or physical properties
Starex; LG Chem
turbine; No. 140
23
7
1
Unsuitable due to decomposition; swelling; dissolution
"
diesel
50
9
Resistant over a period of months to years
Terluran; BASF
"
Oleic Acid
with cottonseed oil
with cottonseed oil
50
2810
Exposure medium
Terlux; BASF
9
"
50
21.1
1
6
Exposure strain is critical strain - level where stress cracks first appear
Variable strain bending form
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
Terlux; BASF
50
21.1
1
6
"
"
"
50
22
1
3
"
"
"
50
22
1
3
"
"
"
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Oleic Acid (cont)
Oleum 100
Olive Oil
100
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
9
Almost no change in either appearance or physical properties
23
7
9
No change observed
20.03
99.4
Toyolac 500; Toray Industries
23
7
9
"
20.03
99.4
Toyolac 100; Toray Industries
23
7
9
"
20.03
99.4
Toyolac 300; Toray Industries
23
7
9
"
20.03
99.4
Toyolac 600; Toray Industries
Starex; LG Chem
23
7
9
"
0.00]0.05
102.5]103.5
Toyolac 900; Toray Industries
23
7
9
No noticeable change in appearance
0.05
103
Toyolac 900; Toray Industries; Specimen: Transparent
23
7
9
"
20.2
98
Toyolac Parel TP10; Toray Industries; Specimen: Antistatic
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
50
4
"
Terlux; BASF
7
Acceptable; minor effect
Cycolac; GE Plastics
23
2
Not acceptable
65
2
"
9
Plastic was unaffected for duration of test
23
28
52
28
Terluran; BASF
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
9
"
"
powder
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
7
9
No change observed
20.03
99.3
Toyolac 500; Toray Industries
23
7
9
"
20.03
99.3
Toyolac 100; Toray Industries
23
7
9
"
20.03
99.3
Toyolac 300; Toray Industries
23
7
9
"
20.03
99.3
Toyolac 600; Toray Industries
23
7
9
"
Toyolac 900; Toray Industries
23
7
9
No noticeable change in appearance
Toyolac 900; Toray Industries; Specimen: Transparent
2811
23
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
23
Olive Oil (cont)
No noticeable change in appearance
Tensile strength
Material note
Impact strength
99
Toyolac Parel TP10; Toray Industries; Specimen: Antistatic
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
20
9
"
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
oPhenylphenol
Orange Juice
Outdoor Weathering
9
Test note Elong.
powder
Onions
Orange Oil
7
% Retained
100
23
28
2
100
52
28
2
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
22
1
9
No fail @ 1.2% outer fiber strain
Variable strain bending form
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
solution
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
"
20
4
"
Terlux; BASF
"
50
4
"
Terluran; BASF
"
50
4
"
Terlux; BASF
Arizona (hot & dry); inclined 45° south; no insulative backing
182
5
ΔE color change (CIE lab) of 2.8; data from BFGoodrich Geon literature
Florida (hot & humid); inclined 45° south; no insulative backing
182
7
ΔE color change (CIE lab) of 2.7; data from BFGoodrich Geon literature
66
100
2812
Exposure medium
58
Tensile strength retained at yield; dart impact - ASTM D4226 C.125 dart method A
Specimen: 3.2 mm (0.125 in) thick for impact, natural color samples
87
"
Specimen: 3.2 mm (0.125 in) thick samples for impact
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Outdoor Weathering (cont)
ABS
Exposure medium
% Retained Elong.
Tensile strength
Test note
Material note
47
Tensile strength retained at yield; dart impact - ASTM D4226 C.125 dart method A
Specimen: 3.2 mm (0.125 in) thick for impact, natural color samples
22
"
"
Impact strength
Ohio (temperate, pollution); 45 degrees south; no insulative backing
182
4
ΔE color change (CIE lab) of 2.1; data from BFGoodrich Geon literature
Arizona (hot & dry); inclined 45° south; no insulative backing
365
4
ΔE color change (CIE lab) of 10.7; data from BFGoodrich Geon literature
Florida (hot & humid); inclined 45° south; no insulative backing
365
6
ΔE color change (CIE lab) of 2.9; data from BFGoodrich Geon literature
75
"
Specimen: 3.2 mm (0.125 in) thick samples for impact
Ohio (temperate, pollution); 45 degrees south; no insulative backing
365
3
ΔE color change (CIE lab) of 5.8; data from BFGoodrich Geon literature
53
"
Specimen: 3.2 mm (0.125 in) thick for impact, natural color samples
West Virginia
365
7
84
81
Impact retained is Izod; modulus retained is flexural modulus
Cycolac L; GE Plastics; Specimen: Natural color
"
365
7
104
93
"
Cycolac L; GE Plastics
61
105
365
8
102
85
"
Cycolac T; GE Plastics
365
7
101
75
"
Cycolac T; GE Plastics; Specimen: Natural color
Arizona (hot & dry); inclined 45° south; no insulative backing
730
2
ΔE color change (CIE lab) of 16.5; data from BFGoodrich Geon literature
8
Tensile strength retained at yield; dart impact - ASTM D4226 C.125 dart method A
Specimen: 3.2 mm (0.125 in) thick for impact, natural color samples
Florida (hot & humid); inclined 45° south; no insulative backing
730
4
ΔE color change (CIE lab) of 2.9; data from BFGoodrich Geon literature
58
"
Specimen: 3.2 mm (0.125 in) thick samples for impact
Ohio (temperate, pollution); 45 degrees south; no insulative backing
730
1
ΔE color change (CIE lab) of 13.7; data from BFGoodrich Geon literature
43
"
Specimen: 3.2 mm (0.125 in) thick for impact, natural color samples
88
2813
" "
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Outdoor Weathering (cont)
Oxalic Acid
Tensile strength
Impact strength
Test note
Material note
Cycolac L; GE Plastics; Specimen: Natural color
730
5
72
69
Impact retained is Izod; modulus retained is flexural modulus
"
730
6
107
89
"
Cycolac L; GE Plastics
"
730
6
92
61
"
Cycolac T; GE Plastics; Specimen: Natural color
"
730
6
104
74
"
Cycolac T; GE Plastics
"
1095
6
85
52
"
Cycolac T; GE Plastics; Specimen: Natural color
"
1095
5
62
59
"
Cycolac L; GE Plastics; Specimen: Natural color
"
1095
7
109
86
"
Cycolac L; GE Plastics
"
1095
6
104
68
"
Cycolac T; GE Plastics
"
1826
3
51
50
"
Cycolac L; GE Plastics; Specimen: Natural color
"
1826
6
111
83
"
Cycolac L; GE Plastics
"
1826
6
104
63
"
Cycolac T; GE Plastics
"
1826
5
81
45
"
Cycolac T; GE Plastics; Specimen: Natural color
23
28
7
52
28
100
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
Oxymethylfurfurol
Elong.
West Virginia
100
o-Xylene
% Retained
2814
Exposure medium
9
"
Terlux; BASF
100
23
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
28
100
52
0
"
"
,0.00005
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
,0.00005
20
1
"
Terlux; BASF
,0.00005
50
1
"
Terluran; BASF
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Oxymethylfurfurol (cont)
Ozone
Palamoll 644
,0.00005
50
100
23
100 ,0.0005
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
52
28
7
"
"
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
based on adipic acid
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
"
20
1
"
Terlux; BASF
"
50
1
"
Terluran; BASF
"
50
1
"
Terlux; BASF
20
1
"
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
Palamoll 646
50
Palm Oil
"
Terlux; BASF
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
20
9
"
Terluran; BASF
20
9
"
Terlux; BASF
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
20
Palmitic Acid powder
23
28
2815
1
100
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Palmitic Acid (cont)
Paprika
p-Cresol
Tensile strength
Material note
Impact strength
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
52
ground
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
28
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
5
100
52
28
5
"
"
paraffin oil
100
23
28
9
Plastic was unaffected for duration of test
"
"
100
52
28
5
Moderate effect; expected life: weeks to months
"
23
7
8
Resistant - no visual change observed
Paraffin Oil
Paraldehyde
Test note Elong.
powder
Parachlordine
Paraffin
% Retained
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
7
Acceptable; minor effect
Cycolac; GE Plastics
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
2
100
52
28
2816
Exposure medium
"
"
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
ABS
2
20
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Tensile strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Impact strength
2
Not resistant; plastic severely crazed; softened or dissolved
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
solution
20
9
"
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
20
9
"
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
Peanut Oil
Penicillin
50
9
"
Terlux; BASF
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
5
Moderate effect; expected life: weeks to months
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
Pentane
3-Pentanone
Elong.
7
Peanut Butter
Pentachlorophenol
% Retained
23
p-Cymene
Pectin
ABS
Exposure medium
100
23
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
"
2817
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
3-Pentanone (cont)
Pentene Pepper
Peppermint Oil
Perchloric Acid
Perchloroethylene
% Retained Elong.
Tensile strength
Test note
Material note
Impact strength
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
2
"
"
"
ground
100
23
28
3
Considerable change; expected life: days
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
3
"
"
black or white; ground
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
"
50
4
"
Terluran; BASF
"
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
7
100
52
28
7
"
"
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
2818
Exposure medium
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
20
Perchloroethylene (cont)
Permatex
Petroleum Ether
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
50
1
2
"
"
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
50
4
"
Terlux; BASF Lastilac; LATI Industria Termoplastici S.p.a.
75
1
2
Poor resistance; loss of mechanical properties; swelling
Permatex Lock Nut
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
Permatex Forma-Gasket #1
23
7
4
"
"
"
7
Acceptable; minor effect
"
9
Almost no change in either appearance or physical properties
Starex; LG Chem
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
No change observed
Petrolatum Petroleum
ABS
Exposure medium
unleaded
23
7
23
7
9
23
7
9
"
23
7
9
"
23
7
9
"
23
7
8
23
7
50
0.19
99.0
Toyolac 500; Toray Industries
0.19
99.0
Toyolac 100; Toray Industries
0.19
99.0
Toyolac 300; Toray Industries
0.19
99.0
Toyolac 600; Toray Industries
Slightly yellowish discoloration
0.10]0.15
103.0]106.0
Toyolac 900; Toray Industries
8
Slightly yellowed
0.15
103
Toyolac 900; Toray Industries; Specimen: Transparent
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
2819
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
50
Petroleum Ether (cont)
Petroleum Jelly
carbolated
Phenacetin
% Retained Test note Elong.
Tensile strength
Material note
2820
Exposure medium
Impact strength
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
9
Resistant over a period of months to years
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
20
9
Resistant over a period of months to years
"
7
7
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
8
"
"
"
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
9
Resistant over a period of months to years
"
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
50
9
Resistant over a period of months to years
"
20
9
"
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
ABS
23
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Phenol
ABS
Exposure medium
% Retained Elong.
Tensile strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Impact strength
5
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
5
23
7
9
Almost no change in either appearance or physical properties
5
23
7
2
Slightly dark discoloration and partially disintegrated
15.6
65.7
Toyolac 500; Toray Industries
5
23
7
2
"
15.6
65.7
Toyolac 100; Toray Industries
5
23
7
2
"
15.6
65.7
Toyolac 300; Toray Industries
5
23
7
2
"
15.6
65.7
Toyolac 600; Toray Industries
5
23
7
3
Softens and becomes white
10.5]12.0
69.5]73.0
Toyolac 900; Toray Industries
5
23
7
2
Softens; whitens
12
70
Toyolac 900; Toray Industries; Specimen: Transparent
5
23
7
2
Slightly blackened; partially dissolved
15
66
Toyolac Parel TP10; Toray Industries; Specimen: Antistatic
5
23
28
2
Severe attack; softened in few hrs
Starex; LG Chem
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
5
52
28
2
"
"
concentrated
23
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
"
50
1
2
"
"
75
1
"
2
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
2
Not acceptable
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
2821
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
50
Phenol (cont)
1
65
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
Terlux; BASF
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
2
Not acceptable
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
100
23
28
9
Plastic was unaffected for duration of test
"
100
52
28
9
"
2-Phenoxyethanol
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Phenylacetonitrile
23
7
2
"
"
"
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
Phenolsulfonic Acid
Phenoxyacetic Acid
Phenylethyl Alcohol
20
20
Phenylhydrazine
Phosphoric Acid
"
1
"
2
Not resistant; plastic severely crazed; softened or dissolved
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
23
7
2822
Exposure medium
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
28
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
Severe attack; softened in few hrs
"
1
20
9
Resistant over a period of months to years
Terluran; BASF
1
20
9
"
Terlux; BASF
ABS
100
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Phosphoric Acid (cont)
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
1
50
9
Resistant over a period of months to years
Terluran; BASF
1
50
9
"
Terlux; BASF
23
7
9
No change observed
0.33]0.37
102.0]103.3
Toyolac 900; Toray Industries
23
7
9
No noticeable change in appearance
0.37
102
Toyolac 900; Toray Industries; Specimen: Transparent
10
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
10
52
28
7
"
"
25
23
28
7
"
"
25
52
28
7
"
"
30
20
9
Resistant over a period of months to years
Terluran; BASF
30
20
9
"
Terlux; BASF
30
50
9
"
Terluran; BASF
30
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
85
20
9
Resistant over a period of months to years
Terluran; BASF
85
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
85
23
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
85
50
9
Resistant over a period of months to years
Terluran; BASF
85
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
85
52
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
0]40
5
Questionable; moderate effect
Cycolac; GE Plastics
40]100
2
Not recommended; severe effect
"
28
28
2823
10 10
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
23
Phosphoric Acid (cont)
7
crude
Phosphoric Anhydride
Phosphorus Oxychloride Phosphorus Pentachloride Phosphorus Trichloride Phthalic Acid
Phthalic Anhydride
Elong.
Tensile strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Impact strength
8
Resistant - no visual change observed
2
Not recommended; severe effect
Cycolac; GE Plastics
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
7
100
52
28
7
"
"
100
23
28
2
Severe attack; softened in few hrs
"
100
52
28
2
"
"
100
23
28
2
"
"
100
52
28
2
"
"
100
23
28
2
"
"
100
52
28
2
"
"
Resistant over a period of months to years
Terluran; BASF Terlux; BASF
solution
20
9
"
20
9
"
23
6
Good - minor attack
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
65
6
Good - minor attack
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
Phthaloyl Chloride Picric Acid
% Retained
2824
Exposure medium
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Pimento
Test note Elong.
Tensile strength
Material note
Impact strength
Terluran; BASF
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
"
20
4
"
Terlux; BASF
"
50
4
"
Terluran; BASF
"
50
4
"
Terlux; BASF
pine needle oil
pine needle oil
Pineapple Juice
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
3
Considerable change; expected life: days
"
100
52
28
2
Severe attack; softened in few hrs
"
100
52
28
2
"
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Novus #1
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
Novus #2
23
7
4
"
"
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Piperidine
Plastomoll DOA
% Retained
ground
Pine Oil
Plastic Polish
ABS
Exposure medium
20
Terlux; BASF
" Terluran; BASF
2825
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Plastomoll DOA (cont)
Polyethylene Glycol Monolaurate
polyethylene glycol 400 monolaurate "
Pork Lard
50
Potassium Aluminum Sulfate
Potassium Bicarbonate
Potassium Bisulfate
Test note Elong.
Tensile strength
Material note
Impact strength
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
50
4
"
Terluran; BASF
50
4
"
Terlux; BASF
3
Exposure strain is critical strain - level where stress cracks first appear
Variable strain bending form "
21.1
1
22
1
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
2
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50 50
Potassium Aluminum Chloride
% Retained
23
28
52
28
"
9
"
Terlux; BASF
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
9
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
23
7
8
Resistant - no visual change observed
5
Questionable; moderate effect
Cycolac; GE Plastics
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
100
23
28
52
28
2826
Exposure medium
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
"
"
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
ABS
9
20
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
50
Potassium Bisulfate (cont)
9
50
Potassium Borate
Potassium Bromate
Potassium Bromide
Potassium Carbonate Potassium Chlorate Potassium Chloride
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
Resistant over a period of months to years
Terluran; BASF
9
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
9
Resistant over a period of months to years
Terluran; BASF
solution
20
"
20
saturated solution
23
solution
50
"
50
saturated solution
52
solution
28
9
"
Terlux; BASF
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
9
Resistant over a period of months to years
Terluran; BASF
9
"
Terlux; BASF
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
saturated solution
23
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
saturated solution
52
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
9
Plastic was unaffected for duration of test
"
100
52
28
9
"
"
100
23
28
9
"
"
100
52
28
9
"
"
25
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
28
28
Strained in bending fixture
Cycolac; GE Plastics
2827
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Potassium Chloride (cont)
Tensile strength
Material note
Impact strength
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
7
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
5
Questionable; moderate effect
Cycolac; GE Plastics Terluran; BASF
solution
20
9
Resistant over a period of months to years
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
Potassium Cyanide
Potassium Dichromate
Test note Elong.
100
23
Potassium Chromate
% Retained
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
Resistant over a period of months to years
Terluran; BASF Terlux; BASF
solution
20
9
20
9
"
23
6
Good - minor attack
solution
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
"
50
4
"
Terlux; BASF
saturated solution
65
5
Fair - limited use
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
saturated
23
28
ABS
" saturated solution
Potassium Ferricyanide
2828
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
50
Potassium Ferricyanide (cont)
9
50
Potassium Fluoride
Potassium Hydroxide
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
Resistant over a period of months to years
Terluran; BASF
9
"
Terlux; BASF
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
10
20
9
"
Terluran; BASF
10
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
10
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
10
23
7
8
Resistant - no visual change observed
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
10
23
7
8
"
10
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
10
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
30
23
7
8
Resistant - no visual change observed
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
30
23
7
8
"
40
23
7
9
Almost no change in either appearance or physical properties
Starex; LG Chem
50
20
9
Resistant over a period of months to years
Terluran; BASF
saturated
52
solution
28
Chemical resistance per ASTM D543
Chemical resistance per ASTM D543
"
"
2829
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Potassium Hydroxide (cont)
Test note Elong.
Tensile strength
Material note
Impact strength
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
5
Questionable; moderate effect
Cycolac; GE Plastics
50
20
50
23
50
50
1
50
Potassium Iodate
% Retained
solution
concentrated
20
9
Resistant over a period of months to years
Terluran; BASF
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
"
"
50
1
"
Terluran; BASF
"
"
50
1
"
Terlux; BASF Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
8
Resistant - no visual change observed
23
7
8
"
saturated solution
23
7
8
"
"
23
7
8
"
concentrated
23
28
9
Plastic was unaffected for duration of test
28
2830
Exposure medium
Chemical resistance per ASTM D543
" "
Chemical resistance per ASTM D543
" Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
52
9
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Potassium Iodide
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
saturated
23
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
saturated
52
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
7
"
"
100
52
28
7
"
"
100
23
28
7
"
"
100
52
28
7
"
"
Potassium Manganate Potassium Nitrate
28
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
Potassium Permanganate
solution
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
5
Moderate effect; expected life: weeks to months
"
9
Resistant over a period of months to years
Terluran; BASF
20
"
20
saturated
23
9
"
8
Resistant - no visual change observed
solution
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
"
50
4
"
Terlux; BASF
5
Questionable; moderate effect
Cycolac; GE Plastics
7
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
2831
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Potassium Persulfate
Tensile strength
Material note
Impact strength
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
Potassium Sulfide
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
p-Phenylphenol
100
23
28
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
3
Considerable change; expected life: days
"
23
7
8
Resistant - no visual change observed
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
light process oil
Prontosil
Propane
Test note Elong.
solution
Potassium Sulfate
Process Oil
% Retained
2832
Exposure medium
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
gas
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
ABS
liquid
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Propargyl Alcohol
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
100
23
28
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
Severe attack; softened in few hrs
"
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Propionic Acid
Propyl Alcohol
ABS
Exposure medium
n-propyl alcohol
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
2
Severe attack; softened in few hrs
"
solid
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
"
50
4
"
Terluran; BASF
"
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
Propyl Dichloride
100
23
28
100
52
28
2
"
"
Propylene Dichloride
100
23
28
0
Solvent
"
100
52
28
0
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
2833
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Propylene Glycol
Propylene Oxide
Pyridine
solution
Tensile strength
Material note
Impact strength
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
23
7
4
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
50
9
Resistant over a period of months to years
50
9
"
Terlux; BASF
7
Acceptable; minor effect
Cycolac; GE Plastics
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
Terluran; BASF
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
20
1
"
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
20
9
Resistant over a period of months to years
Terluran; BASF
ABS
Pyrogallic Acid
Test note Elong.
100
Propylene Glycol Methyl Ether
1,2-Propylene Oxide
% Retained
2834
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Pyrogallic Acid (cont)
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
solution
20
9
Resistant over a period of months to years
Terlux; BASF
"
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
"
50
4
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
oleic acid
23
7
8
"
"
"
No. 150
23
7
9
Almost no change in either appearance or physical properties
Starex; LG Chem
No. 300
23
7
9
"
"
solution
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
"
20
4
"
Terlux; BASF
"
50
4
"
Terluran; BASF
"
50
4
"
Terlux; BASF
Resorcinol
saturated
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
52
28
9
"
"
Rongalit
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
Quinine Sulfate
Red Copper Oxide Red Oil Refrigerator Oil
Resorcin
Root Beer
23
Rose Oil
20
7
"
8
Resistant - no visual change observed
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
2835
9
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
Rose Oil (cont)
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
Rum
20
9
Resistant over a period of months to years
Terluran; BASF
essence
20
9
"
"
20
9
"
Terlux; BASF
essence
20
9
"
"
Kraft Miracle Whip
23
7
4
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
8
Surface appearance unchanged; data from Georgia Gulf PVC literature
Flexure; samples placed in 20° bend
Cycolac KJU; GE Plastics
23
7
8
Data taken from Georgia Gulf PVC literature
23
28
0
Solvent
Salad Dressings Salad Oil
100
Salicylaldehyde
100
Salicylic Acid
salicylic acid ointment
salicylic acid ointment
0
126
2836
Exposure medium
97
" Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
52
28
0
"
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
"
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
100
52
28
9
Plastic was unaffected for duration of test
"
100
52
28
7
Very slight clouding/ discoloration; expected life: months to years
"
Terluran; BASF
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
solution
20
9
Resistant over a period of months to years
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Tensile strength
Material note
Impact strength
7
9
No change observed
0.33]0.38
99.0]99.9
Toyolac 900; Toray Industries
10
23
7
9
No noticeable change in appearance
0.38
99
Toyolac 900; Toray Industries; Specimen: Transparent
23
8
Resistant
common; dry
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
Sassafras Oil
100
23
28
52
28
3M
Tests were conducted on a variable strain fixture which exhibits chemical resistance of a part under stress
Lustran ABS 248; Monsanto
2
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
Sea Water
Test note Elong.
23
Sandalwood Oil
Scotch Brand 5200
% Retained
10
Saline Solutions
Salts
ABS
Exposure medium
1
"
9
Exposure stress is the critical stress (level at which part stress cracks)
20
9
Resistant over a period of months to years
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
23
7
Terlux; BASF Strained in bending fixture
Cycolac; GE Plastics
Terluran; BASF
2837
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
Sea Water (cont)
50
9
Resistant over a period of months to years
Terlux; BASF
Sebacic Acid Dibutyl Ester
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
Sesame Oil
Seven Up Beverage Shampoo
Shoe Polish
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
Prell
23
7
7
"
"
"
Johnson's Baby
23
7
4
"
"
"
Johnson & Johnson Baby
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Kiwi Solid
23
7
4
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
Silicon
Dow Corning DC 230; silicon fluid
23
Silicone
fluid
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
Silicone Oil
"
50
9
"
GE Viscasil 5000
23
7
7
Exposure stress is the critical stress (level at which part stress cracks)
23
7
9
Almost no change in either appearance or physical properties
2838
Exposure medium
Terlux; BASF Strained in bending fixture
Cycolac; GE Plastics
Starex; LG Chem
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Silver Acetate
Silver Nitrate
Soaps
Sodium Acetate
Sodium Benzoate
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
saturated
23
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
saturated
52
28
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
Dial
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
"
23
7
9
"
"
Cycolac
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
saturated
23
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
saturated
52
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution
20
9
Resistant over a period of months to years
Terluran; BASF
20 23
solution "
28
28
9
"
Terlux; BASF
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
28
2839
" saturated
28
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Sodium Benzoate (cont)
Sodium Bisulfate
Sodium Bisulfite
Sodium Borate
Test note Elong.
Tensile strength
Material note
Impact strength
52
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
9
Plastic was unaffected for duration of test
"
100
52
28
9
"
"
saturated
Sodium Bicarbonate
% Retained
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF Lastilac; LATI Industria Termoplastici S.p.a.
23
1
7
Good resistance
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
7
Acceptable; minor effect
Cycolac; GE Plastics
saturated
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
52
28
9
"
"
5
Questionable; moderate effect
Cycolac; GE Plastics
9
Resistant over a period of months to years
Terluran; BASF
solution
20
"
20
9
"
saturated
23
7
8
Resistant - no visual change observed
"
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
saturated
52
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
7
Acceptable; minor effect
Cycolac; GE Plastics
28
2840
Exposure medium
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
ABS
solution
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Sodium Borate (cont)
ABS
Exposure medium
% Retained Elong.
Tensile strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Impact strength
Saturated solution
23
7
8
Resistant - no visual change observed
Borax; saturated
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
powder, Borax
23
28
9
Plastic was unaffected for duration of test
"
saturated
23
28
9
"
"
Saturated solution
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
Borax; saturated
52
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
powder, Borax
52
28
9
Plastic was unaffected for duration of test
"
saturated
52
28
9
"
"
saturated solution
52
28
7
Very slight clouding/ discoloration; expected life: months to years
"
100
23
28
9
Plastic was unaffected for duration of test
"
100
52
28
Sodium Bromate
9
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
Sodium Bromide
100
23
28
7
100
52
28
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
2841
7
solution
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
Starex; LG Chem
2
23
7
9
Almost no change in either appearance or physical properties
aq.
2
23
7
8
Slightly yellowish discoloration
0.49
97.7
Toyolac 100
"
2
23
7
8
"
0.49
97.7
Toyolac 100; Toray Industries
"
2
23
7
8
"
0.49
97.7
Toyolac 300
"
2
23
7
8
"
0.49
97.7
Toyolac 300; Toray Industries
"
2
23
7
8
"
0.49
97.7
Toyolac 500
"
2
23
7
8
"
0.49
97.7
Toyolac 500; Toray Industries
"
2
23
7
8
"
0.49
97.7
Toyolac 600
"
2
23
7
8
"
0.49
97.7
Toyolac 600; Toray Industries
Sodium Carbonate
2
23
7
9
No change observed
0.32]0.39
96.0]97.0
Toyolac 900
2
23
7
9
No noticeable change in appearance
0.39
96
Toyolac 900; Specimen: Transparent
2
23
7
9
No change observed
0.32]0.39
96.0]97.0
Toyolac 900; Toray Industries
2
23
7
9
No noticeable change in appearance
0.39
96
Toyolac 900; Toray Industries; Specimen: Transparent
10
23
7
9
Almost no change in either appearance or physical properties
Starex; LG Chem
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Specimen: In accordance with ASTM D543-84
100
23
28
9
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
Magnum; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
saturated solution
2842
Exposure medium
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Specimen: 50.8 mm (2 in) diameter discs
23
7
8
"
"
"
23
7
8
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
23
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Sodium Carbonate (cont)
ABS
Exposure medium
% Retained Elong.
Tensile strength
Test note
Material note
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Impact strength
saturated solution
23
7
8
Resistant - no visual change observed
"
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Specimen: In accordance with ASTM D543-84
"
23
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
saturated solution
52
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Specimen: In accordance with ASTM D543-84
"
52
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
5
Questionable; moderate effect
Cycolac
5
"
Cycolac; GE Plastics
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
10
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
aq.
10
23
7
8
Slightly yellowish discoloration
0.39
98.8
Toyolac 100; Toray Industries
"
10
23
7
8
"
0.39
98.8
Toyolac 300; Toray Industries
"
10
23
7
8
"
0.39
98.8
Toyolac 500; Toray Industries
"
10
23
7
8
"
0.39
98.8
Toyolac 600; Toray Industries
25
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
100
23
28
9
Plastic was unaffected for duration of test
100
52
28
Sodium Chlorate
Sodium Chloride
Strained in bending fixture
Cycolac; GE Plastics
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
solution
20
9
"
"
2843
9
dry
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Sodium Chloride (cont)
Sodium Chloroacetate
Sodium Chromate
Test note Elong.
Tensile strength
Material note
Impact strength
dry
20
9
Resistant over a period of months to years
Terlux; BASF
solution
20
9
"
"
Resistant - no visual change observed
Chemical resistance per ASTM D543 "
23
7
8
saturated
23
7
8
"
dry
50
9
Resistant over a period of months to years
Terluran; BASF
solution
50
9
"
"
dry
50
9
"
Terlux; BASF
solution
50
9
"
"
7
Acceptable; minor effect
Cycolac; GE Plastics
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs "
saturated
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
52
28
9
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
23
8
Excellent resistance - no recognizable attack
65
8
"
Sodium Cyanide Sodium Dichromate
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
saturated
23
28
9
"
"
"
52
28
7
Very slight clouding/ discoloration; expected life: months to years
"
100
23
28
9
Plastic was unaffected for duration of test
"
100
52
28
9
"
"
Sodium Ferricyanide Sodium Fluoride
% Retained
2844
Exposure medium
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Sodium Fluoride (cont)
saturated
23
solution
Sodium Hydroxide
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
saturated
52
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
Sodium Hydrosulfite
28
ABS
Exposure medium
28
1
23
7
9
No change observed
0.33]0.39
98.5]99.5
Toyolac 900; Toray Industries
1
23
7
9
No noticeable change in appearance
0.39
99
"
1
23
7
9
"
0.39
99
Toyolac 900; Toray Industries; Specimen: Transparent
10
23
1
7
Good resistance
10
23
7
3
Stress cracking observed; data from Georgia Gulf PVC literature
10
23
7
7
Data taken from Georgia Gulf PVC literature
10
23
7
9
Almost no change in either appearance or physical properties
10
23
7
8
Slightly yellowish discoloration
0.36
97.4
Toyolac 100; Toray Industries
10
23
7
8
"
0.36
97.4
Toyolac 300; Toray Industries
10
23
7
8
"
0.36
97.4
Toyolac 500; Toray Industries
10
23
7
8
"
0.36
97.4
Toyolac 600; Toray Industries
10
23
7
9
No change observed
0.30]0.34
97.6]98.4
Toyolac 900; Toray Industries
10
23
7
9
No noticeable change in appearance
0.34
98
"
10
23
7
9
"
0.34
98
Toyolac 900; Toray Industries; Specimen: Transparent
Lastilac; LATI Industria Termoplastici S.p.a. Flexure; samples placed in 20° bend 0.3
194
104
Cycolac KJU; GE Plastics
" Starex; LG Chem
2845
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Sodium Hydroxide (cont)
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
10
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical
10
23
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
10
52
28
7
"
Magnum; Dow Chemical
10
52
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
5
Questionable; moderate effect
Cycolac; GE Plastics
20
2846
Exposure medium
25
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
"
40
23
7
9
Almost no change in either appearance or physical properties
40
23
7
9
Slightly yellowish discoloration
20.16
99.2
Toyolac 100; Toray Industries
40
23
7
9
"
20.16
99.2
Toyolac 300; Toray Industries
40
23
7
9
"
20.16
99.2
Toyolac 500; Toray Industries
40
23
7
9
"
20.16
99.2
Toyolac 600; Toray Industries
40
23
7
9
No change observed
0.05]0.09
97.0]97.8
Toyolac 900; Toray Industries
40
23
7
9
No noticeable change in appearance
0.09
97
"
40
23
7
9
"
0.09
97
Toyolac 900; Toray Industries; Specimen: Transparent
40
23
7
7
Slightly yellowed
1.1
94
Toyolac Parel TP10; Toray Industries
40
23
7
7
"
1.1
94
Toyolac Parel TP10; Toray Industries; Specimen: Antistatic
50
20
9
Resistant over a period of months to years
50
20
9
"
Terlux; BASF
50
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
50
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical
Starex; LG Chem
Terluran; BASF
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Sodium Hydroxide (cont)
50
23
50
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
50
9
Resistant over a period of months to years
Terluran; BASF
50
50
9
"
Terlux; BASF
50
52
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical
50
52
28
9
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
50
5
Questionable; moderate effect
Cycolac; GE Plastics
80
5
"
"
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical
100
23
28
9
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
65
28
9
"
"
100
Sodium Hypochlorite
28
ABS
Exposure medium
65
28
9
"
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Magnum; Dow Chemical Lustran; Monsanto
23
7
8
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
15
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
15
52
28
7
"
"
solution with 12% chlorine
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
5% chlorine
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution with 12% chlorine
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
2847
23
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Sodium Hypochlorite (cont)
5% chlorine
Sodium Nitrate
Sodium Nitrite
Test note Elong.
Tensile strength
Material note
Impact strength
52
28
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
100
52
28
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
20
Sodium Perborate
% Retained
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
Sodium Phosphate
2848
Exposure medium
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
tert; solution
20
9
"
"
sec; solution
20
9
"
Terlux; BASF
tert; solution
20
9
"
"
ABS
sec; solution
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Sodium Phosphate (cont)
Sodium Salicylate
sec; solution
50
9
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
Resistant over a period of months to years
Terluran; BASF
tert; solution
50
9
"
"
sec; solution
50
9
"
Terlux; BASF
tert; solution
50
9
"
"
powder
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
52
28
7
"
"
100
23
28
7
"
"
100
52
28
7
"
"
100
23
28
9
Plastic was unaffected for duration of test
"
100
52
28
9
"
"
9
Resistant over a period of months to years
Terluran; BASF
Sodium Silicate Sodium Sulfate solution
20
"
20 23
solution
50
"
Sodium Sulfide
7
50
9
"
8
Resistant - no visual change observed
9
Resistant over a period of months to years
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
9
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
Sodium Sulfite
9
"
Terlux; BASF
100
23
50 28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
2849
solution
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Sodium Sulfite (cont) Sodium Thiosulfate
Solder Flux
% Retained Test note Elong.
Tensile strength
Material note
2850
Exposure medium
Impact strength
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
aq.
10
23
7
9
No change observed
0.47
98.3
Toyolac 100
"
10
23
7
9
"
0.47
98.3
Toyolac 100; Toray Industries
"
10
23
7
9
"
0.47
98.3
Toyolac 300
"
10
23
7
9
"
0.47
98.3
Toyolac 300; Toray Industries
"
10
23
7
9
"
0.47
98.3
Toyolac 500
"
10
23
7
9
"
0.47
98.3
Toyolac 500; Toray Industries
"
10
23
7
9
"
0.47
98.3
Toyolac 600
"
10
23
7
9
"
0.47
98.3
Toyolac 600; Toray Industries
10
23
7
7
"
0.32]10.28
98.3]99.1
Toyolac 900
10
23
7
9
No noticeable change in appearance
0.32
98
Toyolac 900; Specimen: Transparent
10
23
7
7
No change observed
0.32]10.28
98.3]99.1
Toyolac 900; Toray Industries
10
23
7
9
No noticeable change in appearance
0.32
98
Toyolac 900; Toray Industries; Specimen: Transparent
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
saturated
23
28
9
Plastic was unaffected for duration of test
Magnum; Specimen: In accordance with ASTM D543-84
"
23
28
9
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
saturated
52
28
9
Plastic was unaffected for duration of test
Magnum; Specimen: In accordance with ASTM D543-84
"
52
28
9
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
Allen
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Solvents
organic
Sorbitol
Spearmint
Sperm Oil
Stannic Chloride
Stannous Chloride
Tensile strength
Material note
Impact strength
0
Poor resistance; soluble in ketones and esters; aromatic and chlorinated hydrocarbons
RTP 600; RTP Company
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
100
52
28
9
"
"
spearmint oil
100
23
28
2
Severe attack; softened in few hrs
"
"
100
52
28
2
"
"
100
23
28
9
Plastic was unaffected for duration of test
"
100
52
28
9
"
"
9
Resistant over a period of months to years
Terluran; BASF
20
Spruce Oil
Test note Elong.
23
20
Spermaceti
% Retained
100
Soya Oil
Soybean Oil
ABS
Exposure medium
"
Terlux; BASF
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
100
23
28
2
Severe attack; softened in few hrs
"
100
52
28
2
"
"
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
100
52
28
7
"
"
100
23
28
7
"
"
100
52
28
7
"
"
2851
9
100
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Steak Sauce
Tensile strength
Test note
Material note
Impact strength
23
7
7
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
Worcestershire
23
7
7
"
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
crystals
23
28
crystals
52
28
5
Moderate effect; expected life: weeks to months
white spirits
23
7
4
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
"
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
7
Acceptable; minor effect
7
Exposure stress is the critical stress (level at which part stress cracks)
7
Good resistance; attacked by oxidizing acids
23
STP Oil Treatment
7
Strong Acids
Strontium Bromide
Cycolac; GE Plastics Strained in bending fixture
"
RTP 600; RTP Company
9
Excellent resistance
"
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
Strong Alkalis
20
50
Strontium Salicylate
Elong.
A-1
Stearic Acid
Stoddard Solvents
% Retained
2852
Exposure medium
"
Terlux; BASF
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
saturated
23
28
9
"
"
ABS
9
powder
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Strontium Salicylate (cont)
Tensile strength
Material note
Impact strength
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
saturated
52
28
7
Very slight clouding/ discoloration; expected life: months to years
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
9
100
52
28
9
"
"
7
Acceptable; minor effect
Cycolac; GE Plastics Terluran; BASF
liqs. solution
30
20
9
Resistant over a period of months to years
"
30
20
9
"
Terlux; BASF
"
30
50
9
"
Terluran; BASF
"
30
50
9
"
Terlux; BASF
sulfur ointment
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
9
Resistant over a period of months to years
Terluran; BASF
23
1
50 50
Sulfur Chloride
Sulfur Dioxide
Test note Elong.
52
Sucrose
Sulfur
% Retained
powder
Strychnine
Sugars
ABS
Exposure medium
dry
"
Terlux; BASF
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
2853
9
100
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Sulfur Dioxide (cont)
Tensile strength
Material note
Impact strength
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
moist
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
dry
100
52
28
7
"
"
liquid @ 46 psi
100
52
28
2
Severe attack; softened in few hrs
"
moist
100
52
28
7
Very slight clouding/ discoloration; expected life: months to years
"
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2
Not recommended; severe effect
Cycolac; GE Plastics
9
Resistant over a period of months to years
Terluran; BASF
20
Sulfur Hexafluoride
20
Sulfuric Acid
Test note Elong.
liquid @ 46 psi
moist
Sulfur Trioxide
% Retained
9
"
Terlux; BASF
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
1
23
7
9
No change observed
0.35]0.42
100]101.8
Toyolac 900; Toray Industries
1
23
7
9
No noticeable change in appearance
0.42
100
"
1
23
7
9
"
0.42
100
Toyolac 900; Toray Industries; Specimen: Transparent
3
23
7
9
Almost no change in either appearance or physical properties
Starex; LG Chem
10
20
9
Resistant over a period of months to years
Terluran; BASF
10
20
9
"
Terlux; BASF
10
23
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
1
2854
Exposure medium
"
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Sulfuric Acid (cont)
10
23
7
8
Surface appearance unchanged; data from Georgia Gulf PVC literature
10
23
7
7
Data taken from Georgia Gulf PVC literature
0.1
10
23
7
9
No change observed
10
23
7
9
10
23
7
10
23
7
10
23
10
ABS
Exposure medium
% Retained Elong.
160
Tensile strength
Test note
Material note
Flexure; samples placed in 20° bend
Cycolac KJU; GE Plastics
Impact strength
97
"
0.44
97.4
Toyolac 100; Toray Industries
"
0.44
97.4
Toyolac 300; Toray Industries
9
"
0.44
97.4
Toyolac 500; Toray Industries
9
"
0.44
97.4
Toyolac 600; Toray Industries
7
9
"
0.24]0.30
97.5]99.0
Toyolac 900; Toray Industries
23
7
9
No noticeable change in appearance
0.3
97.5
"
10
23
7
9
"
0.3
97.5
Toyolac 900; Toray Industries; Specimen: Transparent
10
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical
10
23
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
10
23
8
10
23
5
10
50
9
Resistant over a period of months to years
Terluran; BASF
10
50
9
"
Terlux; BASF
10
52
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical
10
52
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
25
23
7
7
Exposure stress is the critical stress (level at which part stress cracks)
30
23
7
9
Almost no change in either appearance or physical properties
30
23
7
9
No change observed
0.17
99.1
Toyolac 100; Toray Industries
30
23
7
9
"
0.17
99.1
Toyolac 300; Toray Industries
90.3
76.9
LNP Engineering Plastics; Specimen: ASTM D1822 tensile impact samples Flexural stress
Strained in bending fixture
"
Cycolac; GE Plastics
Starex; LG Chem
2855
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
30
23
7
9
No change observed
0.17
99.1
Toyolac 500; Toray Industries
30
23
7
9
"
0.17
99.1
Toyolac 600; Toray Industries
30
23
7
9
Slightly yellowish discoloration
0.05]0.07
101.0]102.1
Toyolac 900; Toray Industries
30
23
7
8
Slightly yellowed
0.07
101
"
30
23
7
8
"
0.07
101
Toyolac 900; Toray Industries; Specimen: Transparent
30
23
7
7
No noticeable change in appearance
1.2
93
Toyolac Parel TP10; Toray Industries
30
23
7
7
"
1.2
93
Toyolac Parel TP10; Toray Industries; Specimen: Antistatic
30
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical
30
23
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
30
52
28
7
"
Magnum; Dow Chemical
30
52
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
35
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
battery acid
38
20
9
Resistant over a period of months to years
Terluran; BASF
"
38
20
9
"
Terlux; BASF
Sulfuric Acid (cont)
"
38
50
9
"
Terluran; BASF
"
38
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
50
20
9
Resistant over a period of months to years
Terluran; BASF
50
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
50
23
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical
28
2856
Exposure medium
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Sulfuric Acid (cont)
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
50
9
Resistant over a period of months to years
Terluran; BASF
50
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
50
52
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical
50
52
28
7
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
80
23
28
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical
80
23
28
5
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
80
52
28
5
"
Magnum; Dow Chemical
80
52
28
5
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
90
23
28
3
Considerable change; expected life: days
Magnum; Dow Chemical
90
23
28
3
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
90
52
28
3
"
Magnum; Dow Chemical
90
52
28
3
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
98
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical
98
23
28
2
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
98
65
28
2
"
Magnum; Dow Chemical
98
65
28
2
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
7
Acceptable; minor effect
Cycolac; GE Plastics
23
50
10]75
28
2857
7
50
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
0]10
Sulfuric Acid (cont)
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
7
Acceptable; minor effect
Cycolac; GE Plastics
concentrated
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
"
20
1
"
Terlux; BASF
"
50
1
"
Terluran; BASF
"
50
1
"
Terlux; BASF
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto
23
7
8
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
concentrated
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
"
Lustran; Monsanto
"
23
7
2
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
6
23
28
5
Moderate effect; expected life: weeks to months
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
6
52
28
5
"
"
23
28
5
"
"
Sulfurous Acid
concentrated "
52
28
5
"
"
100
23
28
2
Severe attack; softened in few hrs
"
100
52
28
2
"
"
Coppetone
23
7
4
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
simple sugar
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
7
Acceptable; minor effect
Talcum Powder
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
Tannic Acid
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
Sulfuryl Chloride Suntan Lotion
Syrups
2858
Exposure medium
Cycolac; GE Plastics Strained in bending fixture
"
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Tannic Acid (cont)
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
powder
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
saturated
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
powder
52
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
saturated
52
28
5
Moderate effect; expected life: weeks to months
"
10
23
1
7
Good resistance
Lastilac; LATI Industria Termoplastici S.p.a.
50
23
1
7
"
"
Tartaric Acid
Tea
ABS
Exposure medium
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
saturated solution
23
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
saturated solution
52
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
28
instant
100
23
28
9
"
"
moist leaves
100
23
28
9
"
"
instant
100
52
28
9
"
"
moist leaves
100
52
28
7
Very slight clouding/ discoloration; expected life: months to years
"
instant
20
9
Resistant over a period of months to years
Terluran; BASF
leaves; moist
20
9
"
"
20
9
"
Terlux; BASF
20
9
"
"
2859
instant leaves; moist
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
23
Tea (cont)
Test note
Material note
Strained in bending fixture
Cycolac; GE Plastics
Impact strength
9
Resistant over a period of months to years
Terluran; BASF
leaves; moist
50
9
"
"
instant
50
9
"
Terlux; BASF
9
"
"
100
50 23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
4
Softened noticeably
Starex; LG Chem
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
23
Tetrachloromethane
Exposure stress is the critical stress (level at which part stress cracks)
Tensile strength
50
20
Tetrachloroethene
9
Elong.
instant
leaves; moist
Tetrachloroethane
7
% Retained
7
2860
Exposure medium
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
2
Not recommended; severe effect
Cycolac; GE Plastics
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Tetrahydrofuran
Tensile strength
Material note
Impact strength
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
20
1
"
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
1
"
Terlux; BASF
100
23
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
Tetralin
20
1
"
Terlux; BASF
4
Softened noticeably
Starex; LG Chem
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
23
Thionyl Chloride
Test note Elong.
23
50
Thioglycolic Acid
% Retained
100
Tetrahydrofurfurol
Tetrahydronaphthalene
ABS
Exposure medium
7
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
100
23
28
2
Severe attack; softened in few hrs
"
100
52
28
2
"
"
2861
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Thionyl Chloride (cont)
Thiophene
Tin (IV) Chloride
Tensile strength
Material note
Impact strength
Terluran; BASF
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
20
1
"
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
1
"
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
"
20
1
"
Terlux; BASF
"
50
1
"
Terluran; BASF
"
50
1
"
Terlux; BASF
20
1
"
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
Titanium Tetrachloride
Toluene
Test note Elong.
20
Thymol
Tin (II) Chloride
% Retained
2862
Exposure medium
100
23
28
0
Solvent
Magnum; Dow Chemical
100
23
28
0
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
Magnum; Dow Chemical
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Toluene (cont)
100
52
28
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF Lastilac; LATI Industria Termoplastici S.p.a.
1
2
Poor resistance; loss of mechanical properties; swelling
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto
23
7
2
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
9
Almost no change in either appearance or physical properties
Starex; LG Chem
23
7
0
Dissolved
Toyolac 900; Toray Industries; Specimen: Transparent
23
7
3
Swollen
Toyolac 100; Toray Industries
23
7
3
"
Toyolac 300; Toray Industries
23
7
3
"
Toyolac 500; Toray Industries
23
7
3
"
Toyolac 600; Toray Industries
23
7
0
Dissolved
Toyolac 900; Toray Industries
23
7
4
Swelled
Toyolac Parel TP10; Toray Industries
23
7
4
"
Toyolac Parel TP10; Toray Industries; Specimen: Antistatic
50
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
2863
23
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
75
Toluene (cont)
1
toluene, toluol
Tomato Juice
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
2
Not recommended; severe effect
Cycolac; GE Plastics
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
9
Resistant over a period of months to years
Terluran; BASF
Crest
9
"
8
Resistant - no visual change observed
50
9
Resistant over a period of months to years
50
9
"
Terlux; BASF
7
Acceptable; minor effect
Cycolac; GE Plastics
2
Exposure stress is the critical stress (level at which part stress cracks)
20
9
Resistant over a period of months to years
20
9
"
Terlux; BASF
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
50
4
"
Terlux; BASF
23
Transformer Oils
7
7
Terlux; BASF Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Terluran; BASF
Strained in bending fixture
"
Terluran; BASF
100
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
23
28
2
"
"
"
crystals "
1,2,4-Trichlorobenzene
Material note
Impact strength
28
23
Trichloroacetic Acid
Tensile strength
23
20
Tribromoethylbenzene
Test note Elong.
100
20
Toothpaste
% Retained
2864
Exposure medium
52
28
2
100
23
28
2
"
"
100
52
28
2
"
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Trichlorobenzene
Trichloroethane
Trichloroethene
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
Terluran; BASF
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
100
23
28
0
Solvent
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical
100
23
28
2
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
0
Solvent
Magnum; Dow Chemical
100
23
28
0
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical
100
52
28
2
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
0
Solvent
Magnum; Dow Chemical
100
52
28
0
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
2865
100
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Trichloroethene (cont)
Material note
Impact strength
Lastilac; LATI Industria Termoplastici S.p.a.
2
Poor resistance; loss of mechanical properties; swelling
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto
23
7
2
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
50
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
75
1
1
"
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
2
Not recommended; severe effect
Cycolac; GE Plastics
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
2
100
52
28
2
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
2
Not recommended; severe effect
Cycolac; GE Plastics
Trichloropropane 23
7
2
Not resistant; plastic severely crazed; softened or dissolved
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
Trichloropropene Tricresyl Phosphate
Tensile strength
1
50
Trichlorophenol
Test note Elong.
23
50
2,4,5-Trichlorophenol
% Retained
2866
Exposure medium
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Tricresyl Phosphate (cont)
Triethanolamine
Triethylene Glycol
ABS
Exposure medium
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
Terluran; BASF
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Specimen: In accordance with ASTM D543-84
100
23
28
9
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
Magnum; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Specimen: 50.8 mm (2 in) diameter discs
23
7
8
"
"
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
50
9
Resistant over a period of months to years
Terluran; BASF
50
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
23
7
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
2867
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Triethylenetetramine
Trisodium Phosphate
Material note
Impact strength
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
23
28
7
100
52
28
7
"
"
powder
23
28
9
Plastic was unaffected for duration of test
"
saturated
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
powder
52
28
9
Plastic was unaffected for duration of test
"
saturated
52
28
5
Moderate effect; expected life: weeks to months
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
D- or L-
20
9
"
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50 23
Turbine Oil
Turpentine
Tensile strength
23
Trypaflavin
Tryptophane
Test note Elong.
100
Triglycol Acetate
Tripropylene Glycol
% Retained
7
2868
Exposure medium
9
"
9
No change observed
Terlux; BASF
5
Questionable; moderate effect
Cycolac; GE Plastics
0.05]0.09
100.0]100.5
Toyolac 900; Toray Industries
23
28
2
Severe attack; softened in few hrs
Magnum; Specimen: In accordance with ASTM D543-84
100
23
28
2
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
Magnum; Specimen: In accordance with ASTM D543-84
ABS
100
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
100
Turpentine (cont)
52
Tensile strength
Material note
Impact strength
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terluran; BASF
20
4
"
Terlux; BASF
2
Exposure stress is the critical stress (level at which part stress cracks)
7
Strained in bending fixture "
Cycolac
23
7
2
"
pine oil
23
7
8
No noticeable change in appearance
0.55
104
Toyolac 900; Toray Industries; Specimen: Transparent
turpentine oil
23
7
9
No change observed
0.40]0.55
104.0]104.9
Toyolac 900
pine oil
23
7
8
No noticeable change in appearance
0.55
104
Toyolac 900; Specimen: Transparent
turpentine oil
23
7
9
No change observed
0.40]0.55
104.0]104.9
Toyolac 900; Toray Industries
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Cycolac; GE Plastics
Terluran; BASF
50
4
"
Terlux; BASF
20
9
Resistant over a period of months to years
Terluran; BASF
20
4
Limited resistance: some swelling; solvation or environmental stress cracking is possible
Terlux; BASF
50
4
"
Terluran; BASF
50
4
"
Terlux; BASF
D- or L-
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
Turpentine Substitute
Undecyl Alcohol
Test note Elong.
Severe attack; softened in few hrs
50
Tyrosine
% Retained
2
23
28
ABS
Exposure medium
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
9
"
"
2869
1-undecanol
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Undecyl Alcohol (cont)
Urea
Tensile strength
Material note
Impact strength
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
8
Resistant - no visual change observed
23
7
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
solution
20
9
Resistant over a period of months to years
Terluran; BASF
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
2
Poor resistance
RTP 600; RTP Company
UV Radiation UV Weathering
Test note Elong.
solution
Uric Acid Urotropin
% Retained
2870
Exposure medium
tested indoors, 6 feet from a fluorescent light with 4 40 watt bulbs
30
9
ΔE color change (CIE lab) of 0.07
Cycolac KJB; GE Plastics; Specimen: Sample originally matched to a standard tan color
"
30
9
ΔE color change (CIE lab) of 0.09
Cycolac KJM; GE Plastics; Specimen: Sample originally matched to a standard tan color
"
30
9
ΔE color change (CIE lab) of 0.08
Cycolac KJU; GE Plastics; Specimen: Sample originally matched to a standard tan color
"
30
9
ΔE color change (CIE lab) of 0.17
Cycolac KJW; GE Plastics; Specimen: Sample originally matched to a standard tan color
"
182
9
ΔE color change (CIE lab) of 0.44
Cycolac KJB; GE Plastics; Specimen: Sample originally matched to a standard tan color
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
UV Weathering (cont)
Tensile strength
Material note
Impact strength
9
ΔE color change (CIE lab) of 0.85
Cycolac KJM; GE Plastics; Specimen: Sample originally matched to a standard tan color
"
182
9
ΔE color change (CIE lab) of 0.26
Cycolac KJU; GE Plastics; Specimen: Sample originally matched to a standard tan color
"
182
9
ΔE color change (CIE lab) of 0.75
Cycolac KJW; GE Plastics; Specimen: Sample originally matched to a standard tan color
"
365
8
ΔE color change (CIE lab) of 1.18
Cycolac KJB; GE Plastics; Specimen: Sample originally matched to a standard tan color
"
365
6
ΔE color change (CIE lab) of 3.11
Cycolac KJM; GE Plastics; Specimen: Sample originally matched to a standard tan color
"
365
9
ΔE color change (CIE lab) of 0.53
Cycolac KJU; GE Plastics; Specimen: Sample originally matched to a standard tan color
"
365
6
ΔE color change (CIE lab) of 3.6
Cycolac KJW; GE Plastics; Specimen: Sample originally matched to a standard tan color
7
7
Exposure stress is the critical stress (level at which part stress cracks)
9
Resistant over a period of months to years
Valerian Drops
20 20
Strained in bending fixture
Cycolac; GE Plastics
Terluran; BASF
9
"
Terlux; BASF
vanilla extract
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
"
100
52
28
5
Moderate effect; expected life: weeks to months
"
23
7
8
Resistant - no visual change observed
100
23
28
9
Plastic was unaffected for duration of test
100
52
28
9
"
"
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
"
Verbena Oil
Test note Elong.
182
23
Vaseline
% Retained
tested indoors, 6 feet from a fluorescent light with 4 40 watt bulbs
V-8 Juice
Vanilla
ABS
Exposure medium
20
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
2871
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
20
Verbena Oil (cont)
1
50
Vinegar
Heinz
Vinyl Chloride
Walnut Oil
Water distilled
distilled
Test note Elong.
Tensile strength
1
"
23
7
9
Exposure stress is the critical stress (level at which part stress cracks)
100
23
28
9
Plastic was unaffected for duration of test
52
28
Material note
Impact strength
Terlux; BASF
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
5
100
% Retained
" Strained in bending fixture
Cycolac; GE Plastics
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
22
1
9
No fail @ 1.2% outer fiber strain
Variable strain bending form
Lustran; Monsanto; Specimen: 6.4 mm (0.25 in) samples
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
50
9
Resistant over a period of months to years
Terluran; BASF
50
9
"
Terlux; BASF
7
Acceptable; minor effect
Cycolac; GE Plastics
23
28
2
Severe attack; softened in few hrs
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
2
"
"
100
23
28
9
Plastic was unaffected for duration of test
"
100
52
28
9
"
"
100
23
28
9
"
"
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
100
52
28
9
Plastic was unaffected for duration of test
"
100
52
28
7
Very slight clouding/ discoloration; expected life: months to years
"
9
Resistant over a period of months to years
Terluran; BASF
ABS
100
20
2872
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
20
Water (cont) distilled, all concentrations
Test note Elong.
Tensile strength
Material note
Impact strength
Terlux; BASF
7
8
Resistant - no visual change observed
23
7
9
Almost no change in either appearance or physical properties
23
7
9
No noticeable change in appearance
0.42
100
Toyolac 900; Toray Industries; Specimen: Transparent
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs Starex; LG Chem
23
7
9
No change observed
0.30]0.42
100]103
Toyolac 900; Toray Industries
23
7
6
No noticeable change in appearance
2.5
84
Toyolac Parel TP10; Toray Industries; Specimen: Antistatic
50
9
Resistant over a period of months to years
50
9
"
Terlux; BASF
7
Acceptable; minor effect
Cycolac; GE Plastics
fresh
Terluran; BASF
9
Acceptable; no effect
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
9
Acceptable; no effect
Cycolac; GE Plastics
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
bleached
20
9
"
Terluran; BASF
"
20
Aero Floor Care Formula
23
Water Colors
lab grade 7
Water Glass
Waxes
Resistant over a period of months to years
% Retained
23
acid, mine
Water Distilled
9
ABS
Exposure medium
7
9
"
2
Exposure stress is the critical stress (level at which part stress cracks)
Terlux; BASF Strained in bending fixture
Cycolac; GE Plastics
23
7
7
"
"
"
carnauba wax
23
7
8
Resistant - no visual change observed
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
bleached
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
2873
liquid carnauba
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
23
Tensile strength
Test note
Material note
Strained in bending fixture
Cycolac; GE Plastics
Impact strength
Exposure stress is the critical stress (level at which part stress cracks)
Weak Acids
9
Excellent resistance
RTP 600; RTP Company
Weak Alkalis
9
"
"
Whale Oil
100
Whiskey
100
bourbon
White Oil
Wintergreen Oil
7
Elong.
7
WD 40
spray lube
% Retained
23
7
9
No noticeable change in appearance
0.15
101
Toyolac 900; Toray Industries; Specimen: Transparent
23
7
9
No change observed
0.26
98.4
Toyolac 100; Toray Industries
23
7
9
"
0.26
98.4
Toyolac 300; Toray Industries
23
7
9
"
0.26
98.4
Toyolac 500; Toray Industries
23
7
9
"
0.26
98.4
Toyolac 600; Toray Industries
23
7
9
"
0.10]0.15
100.8]101.5
Toyolac 900; Toray Industries
23
28
5
Moderate effect; expected life: weeks to months
52
28
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
5
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
8
Resistant - no visual change observed
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
20
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
20
1
"
Terlux; BASF
50
1
"
Terluran; BASF
50
1
"
Terlux; BASF
9
Exposure stress is the critical stress (level at which part stress cracks)
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
23
Witco Punshield 20
23
Xylene
20
7
7
2874
Exposure medium
Chemical resistance per ASTM D543
Strained in bending fixture
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
Cycolac; GE Plastics
Terluran; BASF
ABS
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
20
Xylene (cont)
Zinc Bromide
% Retained Test note Elong.
Tensile strength
Material note
Impact strength
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terlux; BASF
Lastilac; LATI Industria Termoplastici S.p.a.
23
1
2
Poor resistance; loss of mechanical properties; swelling
23
7
2
Exposure stress is the critical stress (level at which part stress cracks)
Strained in bending fixture
Cycolac; GE Plastics
23
7
2
Not resistant; plastic severely crazed; softened or dissolved
Chemical resistance per ASTM D543
Lustran; Monsanto; Specimen: 50.8 mm (2 in) diameter discs
23
7
9
Almost no change in either appearance or physical properties
Starex; LG Chem
50
1
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
50
1
Not resistant: severe swelling; decomposition; solvation or environmental stress cracking
Terluran; BASF
50
1
"
Terlux; BASF
2
Poor resistance; loss of mechanical properties; swelling
Lastilac; LATI Industria Termoplastici S.p.a.
2
Not recommended; severe effect
Cycolac; GE Plastics
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
75
Yeast
ABS
Exposure medium
1
23
28
9
100
52
28
9
"
"
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
"
100
52
28
7
"
"
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
20
2875
100
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
Zinc Hydrosulfite
Tensile strength
Material note
Impact strength
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
solution
20
9
"
Terluran; BASF
20
9
"
Terlux; BASF
23
28
9
Plastic was unaffected for duration of test
Magnum; Specimen: In accordance with ASTM D543-84
"
23
28
9
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
solution
50
9
Resistant over a period of months to years
Terluran; BASF
"
50
9
"
Terlux; BASF
saturated solution
52
28
9
Plastic was unaffected for duration of test
Magnum; Specimen: In accordance with ASTM D543-84
"
52
28
9
"
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
10
23
28
9
"
"
10
52
28
9
"
"
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
20
9
"
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
50
9
"
Terlux; BASF
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
Zinc Ointment
100
23
28
ABS
" saturated solution
Zinc Nitrate
Zinc Oxide
Test note Elong.
100
Zinc Carbonate
Zinc Chloride
% Retained
2876
Exposure medium
Exp. medium note
Conc. (%)
Temp. (°C)
Time (days)
PDL #
Resistance note
% Change Weight
100
Zinc Oxide (cont)
52
28
Test note Elong.
Tensile strength
Material note
Impact strength
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
20
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
9
"
Terlux; BASF
100
23
28
7
Very slight clouding/ discoloration; expected life: months to years
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
7
"
"
9
Resistant over a period of months to years
Terluran; BASF
20
9
"
Terlux; BASF
50
9
"
Terluran; BASF
20
50
Zinc Sulfate
% Retained
9
50
Zinc Stearate
ABS
Exposure medium
9
"
Terlux; BASF
100
23
28
9
Plastic was unaffected for duration of test
Magnum; Dow Chemical; Specimen: In accordance with ASTM D543-84
100
52
28
9
"
" Terluran; BASF
solution
20
9
Resistant over a period of months to years
"
20
9
"
Terlux; BASF
"
50
9
"
Terluran; BASF
"
50
9
"
Terlux; BASF
2877