NHS Bowel Cancer Screening Programme Accreditation Assessment

NHS Bowel Cancer Screening Programme Accreditation Assessment

Abstracts and adequate were defined as the diminishing of haziness. The total duration of colonoscopy, the side effect of medication and the endoscop...

58KB Sizes 1 Downloads 23 Views

Abstracts

and adequate were defined as the diminishing of haziness. The total duration of colonoscopy, the side effect of medication and the endoscopist and patient satisfaction were compared between 2 groups. Endoscopist satisfaction was evaluated by questionnaires. Visual analog scale (0-10) was used for rating patient satisfaction and the side effect of medication. Data analysis was performed by Student’s t test or Chi-square test as appropriate. Results: The demographic data of the 2 groups were comparable. 58% and 41.8% underwent colonoscopy due to the presence of symptoms and screening purpose, respectively. Colonoscopic findings revealed polyps in 48.4%, cancer 3.3% and normal 27.1%. Colonoscopy was not completed in 2 patients (1 from each group). Sodium phosphate plus simethicone, comparing to sodium phosphate plus placebo, improved visibility by diminishing the air bubbles (1.6% vs. 57.6%, P ! 0.0001) but simethicone failed to demonstrate the diminishing of haziness (9.8% vs. 18.6%, P Z 0.15). Endoscopist and patient satisfaction was increased in the simethicone group (95.1% vs. 42.4% (P ! 0.0001) and 8.7 þ 1.8 vs. 7.5þ1.9 (P Z 0.0004), respectively). However, there was no difference in the total duration of colonoscopy (25.0 þ 13.1 vs. 27.5 þ 13.0 minutes) and the side effect of medication (1.37 þ 2.3 vs. 1.79 þ 2.2). Conclusions: The addition of simethicone to sodium phosphate is showed to be benefit for colonoscopic bowel preparation. Simethicone diminishes air bubbles resulting in enhancing visibility and improving the quality of colonoscopy. Endoscopist and patient satisfaction is also heightened by simethicone.

239 Accrediting Competence in Colonoscopy: Validity and Reliability of the UK Joint Advisory Group/NHS Bowel Cancer Screening Programme Accreditation Assessment Roger Barton After national UK audit demonstrated very variable quality of colonoscopy, the introduction of the NHS Bowel Cancer Screening Programme prompted the introduction of a searching assessment to select the screening programme’s future colonoscopists. Leading endoscopists, trainers and the JAG collaborated to develop an appropriate assessment tool after consultation with clinical educationalists in the UK, USA, and Holland. This comprised performance data, a knowledge test (MCQ), and a DOPS (Direct Observation of Procedural Skills) assessment. The aims were to determine the validity and reliability of the assessment. A true/false 30 item x 5 answer MCQ was devised covering key issues. To ensure both professional and educational input, DOPS forms from two national training centres were reviewed by the Trainers Group appointed under the NHS National Endoscopy Training Programme, and important colonoscopy skills were identified and amalgamated into domains. Detailed descriptors for all skill levels were written for each domain. An outline curriculum was published, and assessors underwent both the assessment and detailed assessor training. Performance and demographic data, as well as assessment data both from the MCQ and DOPS over two cases by two assessors were collected prospectively from candidates. Semi-structured questionnaires were collected from candidates and assessors on the validity of the assessment. Colonoscopists submitted performance data and attempted the assessment. In more than 3000 paired judgments on over 100 candidates during more than 200 cases, there was 96% congruence of agreement across the pass/ fail divide (98% for major domains), and between 60-83% absolute congruence across individual domains between assessors, e.g. demonstrates awareness of patient’s consciousness and pain 73%; adequate mucosal visualisation 81%. An expert global opinion agreed with the grading system in 97% of cases. The grading correlated weakly with self-reported caecal intubation rates and MCQ scores (r Z 0.24 & 0.27, p ! 0.01) respectively. No correlation was seen between the grading and colonoscopy numbers in previous year. Of the candidates 93% felt the DOPS assessment was fair or very fair overall, whilst 86% felt the MCQ was fair or very fair. Of the assessors, 75% felt the DOPS was valid or very valid, others felt it was not testing enough nor reliably assessing therapy, whilst 100% of them overall felt the process was fair or very fair. The DOPS accreditation has good face and content validity, and high reliability across the crucial pass/fail divide. Work is in place improving the MCQ.

Patients with colonic resections, poor bowel preparation and severe stricture in the colon were excluded. All procedures were performed by two experienced endoscopists who had performed more than 3000 cases and were blind to the imager view and real-time views were recorded by MEI. The instrument was video colonoscope with an in-built magnetic imaging (CF260DI, Olympus Optical Co., Ltd., Tokyo, Japan). The stiffening function was not used. No sedative medication was given. The time taken to insert the colonoscope into the cecum was measured. The degree of pain in insertion of the colonoscope into the cecum was assessed using the visual analog scale (VAS 0 Z not at all or very easy 100 Z very severe or difficult). Between the OTC-attached group and non-OTC attached group, cecal intubation time and pain in insertion of the colonoscope into the cecum were recorded and with MEI the degree of pain in each type of loop and frequency of loop formation in the sigmoid colon were retrospectively analyzed. Result: Endoscopists performed 483 patients, and 242 patients were randomly allocated to OTC-attached colonoscope and 241 patients to non OTC-attached colonoscope. The median cecal intubation time was 5.6 minutes with the OTC group and 5.9 minutes without OTC group (P Z 0.241). The examination was significantly less painful with the OTC than without OTC (22.8 mm vs. 27.1 mm; p Z 0.014). Loop formation did not occur in 34.8% of cases (168/483). N loop occurred in 47.2% (228/ 483), alpha loop in 11.6% (56/483) and reverse alpha loop in 6.1% (31/483). The degree of pain was significantly higher in reverse alpha loop (53.9mm; p ! 0.001), N loop (33.1 mm; p ! 0.001), alpha loop (38.3 mm; p ! 0.001) than in non loop (9.8mm) and the loops in the sigmoid colon (N, alpha, reverse alpha loop) significantly occurred less in OTC-attached group than in non-OTC attached group. (132/242 vs. 183/241, respectively; p Z 0.0246, by Fisher’s exact test)Conclusions: By attaching the OTC to the tip of the colonoscope, looping (N, a, reverse a) occurred less frequently and resulted in less painful examination compared with conventional colonoscope.

241 Colonoscopy in the Elderly: Worse Preparation, Better Tolerability Kinesh P. Patel, Jocelyn L. Aldridge, Kuldeep Cheent, Gautam Mehta, Neil P. Patel, Nisha Patel, Devinder S. Bansi, Andrew V. Thillainayagam Background: As demographics shift towards an aging population, the use of endoscopy in the elderly is increasing every year. Colonoscopy is safe in this population, but is technically more challenging due to difficulties with adequate bowel preparation and the safe administration of sedation. Aim/Methods: To assess the effectiveness of colonoscopy for complete colonic examination in patients over 75 years of age, all colonoscopies performed in a teaching centre over eight years were analysed for rates of complete examination, as defined by cecal intubation. Any reasons for failure were categorized and recorded. The majority of patients received 4L of polyethylene glycol (PEG) bowel preparation unless contraindicated. Results: In total, 17926 colonoscopies were performed. Under the age of 75, 14.1 per cent of patients had an incomplete examination, rising to 24.6 per cent (p ! 0.001) in those over 75. The reason for the increased failure rate in the elderly was predominantly poor bowel preparation, accounting for 35.0 per cent of unsuccessful examinations. In total, 8.6 per cent of procedures in the elderly were abandoned due to poor preparation against 4.5 per cent in those under 75 (p ! 0.0001). In contrast, only 1.9 per cent of colonoscopies in the elderly were stopped due to discomfort, compared to 3.0 per cent in the younger cohort (p Z 0.001). Conclusion: Colonoscopy in a population over 75 years of age is less successful in imaging the colon, mainly due to problems with bowel preparation. Contrary to popular belief, aborted examinations due to poor patient tolerance in the elderly are unusual; indeed these data clearly show that the elderly tolerate colonoscopy better than younger patients.Strategies to improve bowel preparation will increase the yield of colonoscopy in this population, in whom colonic pathology is common and endoscopy established as safe. Similar tolerability of PEG and sodium phosphate laxatives has been shown in the elderly: hence, further studies on bowel preparation are urgently required to optimise the safety and efficacy of colonoscopy in a vulnerable patient group in which organic pathology is common.

Under 75

240 Evaluation of Patient Pain During Colonoscopy for Types of Looping Between Hood Attached Group and Non-Hood Attached Group: An Analysis Using Magnetic Endoscope Imaging (MEI) Koichiro Sato, Koichi Hirahata, Sumio Fujinuma, Tadayoshi Kakemura, Iruru Maetani Background: Total colonoscopy is usually possible. However it remains at times a technically difficult procedure. The oblique transparent cap (OTC, Top, Tokyo, Japan) attached the tip of the colonoscope allows good visualization and makes the procedure easier by maintaing the distance between the lens and the lumen. The aim of this study was to assess the OTC during the insertion of the colonoscope into the cecum with magnetic endoscope imaging (MEI). Methods: Consecutive 483 patients were randomized to undergo colonoscopy with or without the OTC.

www.giejournal.org

Successful

Unsuccessful

TOTAL

12488

2047

14535

836 2883

3391 17926

Over 75 2555 TOTAL 15043 Colonoscopic success categorised by age

Organic Poor preparationy Discomforty diseasey Under 75 Over 75 TOTAL Causes

647(4.5%)

434(3.0%)

Technical problemsy

399(2.7%) 374(2.6%) 228 293 (8.6%) 66 (1.9%) (6.7%) 177 (5.2%) 940 500 627 551 of colonoscopic failure (% of all colonoscopies) yp

Not specifiedy TOTAL 193(1.3%) 2047(14.1%) 72 (2.1%) 836 (24.6%) 265 2883 ! 0.001

Volume 67, No. 5 : 2008 GASTROINTESTINAL ENDOSCOPY AB77