Bileaflet mechanical valve (St. Jude Medical valve) replacement in long-term dialysis patients

Bileaflet mechanical valve (St. Jude Medical valve) replacement in long-term dialysis patients

Bileaflet Mechanical Valve (St. Jude Medical Valve) Replacement In Long-Term Dialysis Patients Masashi Ura, MD, Ryuzo Sakata, MD, Yoshihiro Nakayama, ...

153KB Sizes 0 Downloads 53 Views

Bileaflet Mechanical Valve (St. Jude Medical Valve) Replacement In Long-Term Dialysis Patients Masashi Ura, MD, Ryuzo Sakata, MD, Yoshihiro Nakayama, MD, and Hiroyoshi Fukui, MD Departments of Cardiovascular Surgery and Nephrology, Kumamoto Central Hospital, Kumamoto City, Japan

Background. Few reports exist on the results of bileaflet mechanical valve (St. Jude Medical prosthesis; St. Jude Medical, Inc, St. Paul, MN) replacement in long-term dialysis patients. Methods and Results. We retrospectively reviewed 12 patients, ranging in age from 50 to 86, undergoing longterm renal dialysis who had also undergone mechanical valve replacement at our institution. Operative procedures included aortic valve replacement, aortic and mitral valve replacement, aortic valve replacement and mitral annuloplasty, mitral valve replacement, and modified Bentall’s operation. There was 1 hospital death (8.3%). During the mean follow-up period of 37.1 months (range: 5– 87 months), there were 2 noncardiac late

deaths. Bleeding from the esophageal varix and from a duodenal ulcer occurred in 1 patient with end-stage liver cirrhosis. There were no other major cases of bleeding or cerebrovascular accidents. There were no valve-related complications. All the survivors demonstrated excellent clinical improvement under the NYHA functional classification. Conclusions. Our study demonstrated good early and long-term results of mechanical valve replacement in patients undergoing long-term dialysis. These favorable results support the continued use of mechanical valves in dialysis patients. (Ann Thorac Surg 1999;68:870 –3) © 1999 by The Society of Thoracic Surgeons

W

viewed. This represents 1.8% of 662 patients in total who underwent valve surgery during the same interval. The patients consisted of 6 men and 6 women with a mean age of 60.1 (range: 50 – 86). Preoperative characteristics are summarized in Table 1. Hemodynamic instability (hypotension or cardiac symptoms) during dialysis was noted in 4 patients.

ith the improvement of operative techniques and perioperative management, favorable results of cardiac operations have been reported for patients undergoing long-term renal dialysis, especially in coronary artery bypass grafting [1– 4]. In contrast, since the first report of valvular operation in 1968 [5], the number of valvular operations has been relatively small. Because of premature calcification in biological valves, mechanical valves have been commonly indicated in long-term renal dialysis patients requiring valve replacement [6 –7]. This view has recently been challenged in a report by Lucke and associates [8]. Although they conclude that the use of mechanical valve is associated with significant risk of complications, and that preference should be given to biological valve instead of mechanical valve prostheses in patients on long-term renal dialysis, little is known about the results of bileaflet mechanical valve (St. Jude Medical prosthesis; St. Jude Medical, Inc, St. Paul, MN) replacement.

Patients and Methods Twelve patients with chronic renal failure who underwent mechanical valve replacement at Kumamoto central hospital between April 1988 and March 1998 were re-

Accepted for publication March 11, 1999. Address reprint requests to Dr Sakata, Kumamoto Central Hospital, 96 Tainoshima, Tamukae-machi, Kumamoto City, 862 Japan; e-mail: [email protected].

© 1999 by The Society of Thoracic Surgeons Published by Elsevier Science Inc

Dialysis Methods Preoperatively, 10 patients were maintained on hemodialysis (HD); 2 were on continuous ambulatory peritoneal dialysis (CAPD). The mean duration of dialysis was 8.2 ⫾ 3.9 years. Patients were dialyzed the day before the operation, and, during cardiopulmonary bypass (CPB), hemofiltration (HF) was performed as described in a previous study [4] to maintain hematocrit at ⬎ 30% and a serum K ⫹ of ⬍ 4.0 mEq/L on disconnection of CPB. Maintenance dialysis was resumed the day after the operation. Nafamostat mesilate instead of heparin was selected as the anticoagulant agent for the first postoperative HD.

Operative Procedures All the operations were performed using standard CPB with moderate hypothermia (30°C–32°C). All the valves were St. Jude Medical valves. Operative procedures are summarized in Table 2. Concomitant procedures included coronary artery bypass grafting in 3, LV aneurysmectomy in 1, and De Vega’s tricuspid annuloplasty in 1. Postoperative oral anticoagulation therapy was started in most cases on the second or third postoperative day. We 0003-4975/99/$20.00 PII S0003-4975(99)00553-6

Ann Thorac Surg 1999;68:870 –3

871

URA ET AL SJM REPLACEMENT IN DIALYSIS PATIENTS

Table 1. Preoperative Characteristics

Table 3. Operative Results

Characteristics

Results

Variable

60.1 ⫾ 10.4 (53– 86) 6:6 8 (66.7%) 5 (41.7%) 2 (16.7%) 2 (16.7%) 4 (33.3%)

Mean age Gender (male:female) Hypertension Diabetes mellitus Cerebrovascular accident ASO Hemodynamic instability during dialysis Method of dialysis Hemodialysis Peritoneal dialysis Preoperative heart rhythm Sinus rhythm af AV-block

10 2

af ⫽ atrial fibrillation; ASO ⫽ arteriosclerosis obliterans; block ⫽ atrioventricular block.

Stay of ICU (day) Duration of intubation (hour) Postoperative hospital stay (day) Postoperative complication Granulocytopenia Gastric ulcer Sepsis, MOF Bradycardia Superficial sternal wound infection Hospital death ICU ⫽ Intensive care unit;

9 (75.0%) 1 (8.3%) 2 (16.7%)

Results 3.9 ⫾ 1.9 20 ⫾ 8.3 25.1 ⫾ 11.2 1 (8.3%) 1 (8.3%) 1 (8.3%) 1 (8.3%) 1 (8.3%) 1 (8.3%)

MOF ⫽ multiple organ failure.

Results AV-

Operative Results

attempted to anticoagulate patients with warfarin sodium, with the thrombotest maintained between 10% and 25%. An antiplatelet regimen of dipyridamole (200 mg daily) and aspirin (81 mg daily) was added to warfarin.

One operative death (8.3%) occurred. A 68-year-old man (case 5) who was doing well after a double valve replacement and TAP died 29 days after the operation of sepsis and subsequent multiple organ failure following ordinary maintenance dialysis. All the patients were extubated within 48 hours, with a mean intubation time of 20.0 ⫾ 8.3 hours. Postoperative complications are summarized in Table 3.

Late Follow-Up

Late Follow-Up

Late follow-up information was collected from the patients’ most recent clinical visits, supported by telephone interviews with home physicians or patients. All traced patients were evaluated for valve-related complications and New York Heart Association (NYHA) class at the time of late follow-up.

All 11 of the survivors were traced. There were 2 late deaths among the operative survivors during the mean follow-up of 37.1 months (range: 5– 87 months). One patient (case 3) died of liver cirrhosis 65 months after the operation and another (case 6) died of gastric cancer 24 months after the operation (Table 4).

Table 2. Operative Procedures Case

Age

Sex

Disease

Operation

1 2 3 4 5 6 7 8 9 10 11

59 55 50 58 68 86 71 54 60 57 50

F F M F M M M M F M F

ASR, MSR AR ASR AS ASR, MSR, TR AS, IHD AS AAE ASR, IHD ASR MR, IHD, LV aneurysm.

12

53

F

AR, MR

AVR, MVR AVR AVR AVR AVR, MVR, TAP. AVR, CABG (Ao-LAD) AVR Modified Bentall AVR, CABG (Ao-LAD, RCA. Ao-CX.) AVR MVR, LV aneurysmectomy, CABG (LITA-LAD, RITA-CX,Ao-CX) AVR, MAP

Aortic cross clamp time (min) ⫽ 99 ⫾ 23;

Method of Dialysis

Duration of Dialysis (years)

HD HD HD CAPD HD HD HD CAPD HD HD HD

9 15 9 3 8 10 9 0.58 7 13 7

HD

8

Extra corporeal circulation time (min) ⫽ 138 ⫾ 29.

Ao ⫽ aorta; AR ⫽ aortic valve regurgitation; AS ⫽ aortic valve stenosis; AVR ⫽ aortic valve replacement; CABG ⫽ coronary artery bypass grafting; CAPD ⫽ continuous ambulatory peritoneal dialysis; CX ⫽ circumflex artery; HD ⫽ hemodialysis; IHD ⫽ ischemic heart disease; ITA ⫽ internal thoracic artery; LAD ⫽ left anterior descending artery; LV ⫽ left ventricle; MR ⫽ mitral valve regurgitation; MS ⫽ mitral valve stenosis; MVR ⫽ mitral valve replacement; TAP ⫽ tricuspid annuloplasty; TR ⫽ tricuspid valve regurgitation.

872

URA ET AL SJM REPLACEMENT IN DIALYSIS PATIENTS

Ann Thorac Surg 1999;68:870 –3

Table 4. Late Results Pre NYHA

Post NYHA

Bleeding Problem

1 2 3 4 6 7 8 9

4 4 3 4 4 2 4 3

1 2 2 3 1 1 1 2

N N Varix, duodenal ulcer N N N N N

10 11 12

3 3 3

1 2 1

N N N

Case

NYHA ⫽ New York Heart Association functional status;

Stopping of Anticoagulant

Follow-up Period (month)

Outcome

N N Y (due to liver cirrhosis) N N N N Y (temporarily before operation for ASO) N N N

87 75 65 48 25 36 24 21

Alive Alive Dead (due to liver dysfunction) Alive Dead (due to cancer) Alive Alive Alive

17 5 5

Alive Alive Alive

ASO ⫽ arteriosclerosis obliterans.

Bleeding Events A bleeding event occurred in 1 patient (case 3; bleeding from the gastrointestinal tract). There were no brain hemorrhages or other major bleeding incidents necessitating hospitalization.

Withdrawal of Anticoagulant Withdrawal of anticoagulant was required in 2 patients during the follow-up period. In case 3, a patient with end-stage liver cirrhosis who had recurrent bleeding from the esophageal varix and a duodenal ulcer, anticoagulant was stopped for 2.5 years. Lack of use of anticoagulant did not lead to thromboembolic events; however, the patient suffered from recurrent bleeding and eventually died of liver cirrhosis as mentioned above. In another patient (case 9), stopping of anticoagulant was necessary before elective operation for arteriosclerosis obliterans (ASO); this did not lead to complications.

Valve-Related Complications There were no valve-related complications such as thromboembolic events, prosthetic endocarditis, hemolysis, structural deterioration, or nonstructural dysfunction during the follow-up period.

Clinical Improvement All the survivors demonstrated excellent clinical improvement according to the NYHA functional classification. Five were in class IV, 5 in class III, and 1 in class II preoperatively, whereas 6 were in class I, 4 in class II, and 1 in class III postoperatively. Every patient demonstrated improved NYHA functional status.

Comment Because there have been a number of reports about premature calcification in biological valves in long-term renal dialysis patients [6 –7], mechanical valves have usually been indicated in these patients requiring valve replacement [1– 4].

This view has been recently challenged in a report by Lucke and associates [8]. The overall estimated KaplanMeier survival was 60% ⫾ 12% at 12 months and 42% ⫾ 14% at 60 months. A large number of patients died during the first 12 months after the operation. They noted that mechanical valve patients had a significantly higher rate of postoperative cerebrovascular accidents or bleeding complications (10 of 10 versus 0 of 9; ␹2 ⫽ 17.0; p ⬍ 0.001). They concluded that the use of mechanical valves was associated with significant risk of complications and that preference should be given to biological valves instead of mechanical valve prostheses in patients on long-term renal dialysis. However, this conclusion should be interpreted with caution. First, there were significantly more aortic and fewer mitral valve replacements in patients undergoing biological valve replacement. Eight of 9 biological valves were aortic, whereas only 4 of 10 mechanical valves were aortic. Thromboembolic complications were significantly higher in patients with mitral valve replacements when compared to patients with aortic valve replacements. Mitral valve prostheses tend to require a more intensive anticoagulation regimen [9 –10], which may partially explain the higher rate of postoperative cerebrovascular accidents or bleeding complications in the mechanical valve patient group in Lucke and associates’ study. Second, as pointed out in their invited commentary, the type of mechanical valves was not uniform in their study. We have used St. Jude Medical valves exclusively in renal dialysis patients. Although the excellent performance of the St. Jude medical valve has been demonstrated in various studies [9 –12], little is known about the results of bileaflet mechanical valve replacement in longterm renal dialysis patients. Lucke and associates noted that bleeding complications occurred to a significant degree in patients with mechanical valves. Bleeding at the site of the arteriovenous fistula or polytetrafluoroethylene graft occurred in 4 of 7 mechanical valve patients on hemodialysis, and

Ann Thorac Surg 1999;68:870 –3

they often required dialysis through an indwelling venous catheter [8]. In our experience, no such procedures were required. Although our series included 1 minor case of bleeding from the CAPD tube exit site, careful management of the anticoagulant regimen easily prevented aggravation of symptoms. Relatively longer cessation of warfarin regimen was required in only 1 terminally ill patient with liver cirrhosis. Lower intensity anticoagulation therapy has recently been demonstrated to result in lower complication rates with the St. Jude Medical prosthesis [9 –12]. Japanese patients with mechanical valve replacements tend to be kept under a lower-level warfarin treatment regimen than in the United States [13]. We attempted to anticoagulate patients with warfarin sodium, with the thrombotest maintained between 10% and 25%. Although accurate control range data based on the prothrombin time international normalized ratio (PTINR) was not available for our series, the control range for warfarin based on the PT-INR seems to be higher in most series from the United States than that noted in this series. This might explain our more successful late results. Frequent percutaneous puncture of their arteriovenous fistula for dialysis puts dialysis patients at additional risk of infection. In fact, 1 of our patients died of sepsis and subsequent multiple organ failure following ordinary maintenance dialysis. Conversion from hemodialysis to peritoneal dialysis might be beneficial for reducing the risk of infection, especially prosthetic valve endocarditis, although no definite conclusion can be drawn from such a small number of patients. Our study demonstrated the successful performance of the St. Jude medical valve in long-term renal dialysis patients. No patients experienced structural deterioration or nonstructural dysfunction during the follow-up period. The well known long-term durability of the St. Jude Medical valve [9 –13] could help high-risk renal dialysis patients to avoid the additional risk of reoperation as a result of structural deterioration of biological valves. It was noteworthy that, in contrast to previous reports, 9 of the 11 operative survivors lived longer than 2 years, and 4 patients survived longer than 4 years. During a mean follow-up of 37.1 months (maximum 87 months), only 2 patients died from noncardiac causes. Longer survival can be expected as a result of the high performance of bileaflet mechanical valves and improved management of dialysis patients.

URA ET AL SJM REPLACEMENT IN DIALYSIS PATIENTS

873

Our study demonstrated good early and long-term results after mechanical valve replacement in patients undergoing long-term dialysis. Although this study did not demonstrate the superiority of performance of bileaflet mechanical valves over biological valves in dialysis patients, our favorable results support continued use of mechanical valves in dialysis patients. This procedure should not be renounced unless the superiority of biological valves is clearly demonstrated.

References 1. Ko W, Kreiger KH, Isom OW. Cardiopulmonary bypass procedures in dialysis patients. Ann Thorac Surg 1993;55: 677– 84. 2. Kaul TK, Fields BL, Reddy MA, Kahn DR. Cardiac operations in patients with end-stage renal disease. Ann Thorac Surg 1994;57:691– 6. 3. Zamora JL, Burdine JT, Karlberg H, Shenaq SM, Noon GP. Cardiac surgery in patients with end-stage renal disease. Ann Thorac Surg 1986;42:113–7. 4. Nakayama Y, Sakata R, Ueyama K, et al. Cardiac surgery in patients with chronic renal failure on maintenance dialysis. J Jpn Assn Thorac Surg. 1997;45:1661– 6. 5. Lansing AM, Leb DE, Berman LB. Cardiovascular surgery in end-stage renal failure. JAMA 1968;204:134– 8. 6. Monson BK, Wickstrom PH, Haglin JJ, Francis G, Comty CM, Helseth HK. Cardiac operation and end-stage renal disease. Ann Thorac Surg 1980;30:267–72. 7. Lamberti JJ, Wainer BH, Fisher KA, Karunaratne HB, AlSadir J. Calcific stenosis of the porcine heterograft. Ann Thorac Surg 1979;28:28–32. 8. Lucke JC, Samy RN, Atkins BZ, et al. Results of valve replacement with mechanical and biological prostheses in chronic renal dialysis patients. Ann Thorac Surg 1997;64: 129–33. 9. Horstkotte D, Schulte HD, Bircks W, Strauer BE. Lower intensity anticoagulation therapy results in lower complication rates with the St. Jude Medical prosthesis. J Thorac Cardiovasc Surg 1994;107:1136– 45. 10. Smith JA, Westlake GW, Mullerworth MH, Skillington PD, Tatoulis J. Excellent long-term results of cardiac valve replacement with the St. Jude Medical valve prosthesis. Circulation 1993;88(part 2):49–54. 11. Baudet EM, Puel V, McBride JT, et al. Long-term results of valve replacement with the St. Jude Medical prosthesis. J Thorac Cardiovasc Surg 1995;109:858–70. 12. Czer LSC, Chaux A, Matloff JM, et al. Ten year experience with the St. Jude Medical valve for primary valve replacement. J Thorac Cardiovasc Surg 1990;100:44–55. 13. Nakano K, Koyanagi H, Hashimoto A, et al. Twelve years experience with St. Jude Medical valve prosthesis. Ann Thorac Surg 1994;57:697–703.