Corrigendum to “A correlation for interfacial area concentration in high void fraction flows in large diameter channels” [Chem. Eng. Sci. 131 (2015)172–186] J.P. Schlegel a,n, T. Hibiki b a b

Department of Mining and Nuclear Engineering, Missouri University of Science and Technology, 222 Fulton Hall, 301W 14th St, Rolla, MO 65409, USA School of Nuclear Engineering, Purdue University, 400 Central Dr., West Layafette, IN 47907-2017, USA

Two of the equations in this paper were published incorrectly, Eqs. (19) and (34). The corrected equations should be N vr ¼ 

vm ¼

ϵ1=3 Lo1=3 σ g Δρ=ρ2f

1=4

ρg jg þ ρf jf ρm

The authors would like to apologize for this oversight.

n

DOI of original article: http://dx.doi.org/10.1016/j.ces.2015.04.004 Corresponding author. Tel.: þ 1 573 341 7703. E-mail address: [email protected] (J.P. Schlegel).

http://dx.doi.org/10.1016/j.ces.2015.10.014 0009-2509/& 2015 Elsevier Ltd. All rights reserved.

ð19Þ