Corrigendum to “CO2 absorption into aqueous potassium salts of lysine and proline: Density, viscosity and solubility of CO2” [Fluid Phase Equilib. 399 (2015) 40–49]

Corrigendum to “CO2 absorption into aqueous potassium salts of lysine and proline: Density, viscosity and solubility of CO2” [Fluid Phase Equilib. 399 (2015) 40–49]

Fluid Phase Equilibria 435 (2017) 131 Contents lists available at ScienceDirect Fluid Phase Equilibria j o u r n a l h o m e p a g e : w w w . e l s...

230KB Sizes 0 Downloads 35 Views

Fluid Phase Equilibria 435 (2017) 131

Contents lists available at ScienceDirect

Fluid Phase Equilibria j o u r n a l h o m e p a g e : w w w . e l s e v i e r . c o m / l o c a t e / fl u i d

Corrigendum

Corrigendum to “CO2 absorption into aqueous potassium salts of lysine and proline: Density, viscosity and solubility of CO2” [Fluid Phase Equilib. 399 (2015) 40e49] Shufeng Shen a, b, *, Ya-nan Yang a, Yong Wang a, Shaofeng Ren a, b, Jiangze Han a, Aibing Chen a a b

School of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China Hebei Research Center of Pharmaceutical and Chemical Engineering, Shijiazhuang 050018, China

The authors regret that some errors were printed in the above article. On page 46, in the section of “3.3.2 CO2 solubility ”, the concentration of LysK in the runs of equilibrium CO2 solubility should be 2.27 M (m1 ¼ 3.186 mol kg1 H2O) instead of 2.50 M. Accordingly, the CO2 loadings, a (mol CO2/mole AAS), in Table 8 and Fig. 12 (page 48), were recalculated and represented. The correct data in Table 8 and Fig. 12 are reprinted below. The authors would like to apologize for any inconvenience caused.

Table 8 Equilibrium solubility of CO2 in aqueous solutions of 2.27 M potassium lysinate at 313 and 333K.a Equilibrium partial pressure of CO2, P*CO2, (kPa)

a (mol CO2/mole 2.27 M potassium lysinate

Fig. 12. CO2 equilibrium partial pressures over amino acid salt solutions and 30 wt% MEA at 313 K and 333 K.

DOI of original article: http://dx.doi.org/10.1016/j.fluid.2015.04.021. * Corresponding author.School of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China. E-mail addresses: [email protected], [email protected] (S. Shen). http://dx.doi.org/10.1016/j.fluid.2017.01.009 0378-3812

313 K a (mol CO2/mole AAS)

333 K

AAS) 1.128 1.099 1.096 1.102 1.097 1.091 1.064 1.052 1.026 1.019 0.998 0.912 0.901 0.884

17.444 14.235 12.354 10.082 8.770 6.657 4.962 3.353 2.412 2.156 1.169 0.209 0.152 0.104

16.088 3.359 2.121 1.807 0.812 0.433 0.320 0.254 0.182 0.140 0.108 0.069

1.031 0.961 0.953 0.914 0.898 0.830 0.774 0.782 0.743 0.744 0.711 0.681

a The measurement uncertainties u are u(T) ¼ 0.1 K, u(a) ¼ 0.002, u(P*CO2) ¼ 0.02 kPa. Measurements were performed at 103.3 ± 2.0 kPa.