Pergamon
PII:
Solar Energy Vol. 69(Suppl.), Nos. 1–6, pp. 117–129, 2000 2001 Elsevier Science Ltd S 0 0 3 8 – 0 9 2 X ( 0 1 ) 0 0 0 6 5 – 2 All rights reserved. Printed in Great Britain 0038-092X / 00 / $ - see front matter
www.elsevier.com / locate / solener
DESIGN OF ANIDOLIC ZENITHAL LIGHTGUIDES FOR DAYLIGHTING OF UNDERGROUND SPACES SIMONE C. MOLTENI † , G. COURRET ‡ , B. PAULE, L. MICHEL and J. L. SCARTEZZINI Solar Energy Laboratory, EPFL, CH-1015 Lausanne, Switzerland Received 20 June 2000; revised version accepted 28 May 2001 Communicated by VOLKER WITTWER
Abstract—Due to the congestion of contemporary large cities, the exploitation of the basement is strongly increasing. This is why, after subways and car parks, new public spaces like concert halls and auditoriums are getting common in downtowns’ basements. For this kind of building typologies, where windows are inadequate and skylights unsuitable, zenithal lightguides can be used to provide daylight. Their luminous performance can be improved by using sunlight trackers or static concentrators, which generally reduce the incoming of daylight during overcast conditions. The theory of anidolic optics (non-imaging optics), was used to overcome this difficulty. Scale models were used to assess their performances thanks to a scanning sky simulator. It was shown that the adjunction of an anidolic element to a plain zenithal lightguide improves its luminous performance: it provides an optimal concentration of sunlight for clear sky and a moderate reduction of the illuminance for overcast conditions. User-friendly abacuses were set up to support the design of anidolic zenithal lightguides in practice, including the shaping and the dimensioning of the device. 2001 Elsevier Science Ltd. All rights reserved.
Daylight can offer, on the other hand, much more than simple energy savings: it corresponds to a physiological need for human beings. Natural light stimulates hormonal regulation, provides significant relief of the feeling of isolation (Bouchet and Fontoynont, 1996), has good effects on some physical and psychological diseases and assists people in shift and computer VDU work (Liberman, 1991). Adequate visual comfort has sometimes a relevant cost but leads to increased motivations and productivity in work. Smiley reports that students attending a daylit school achieved better examination results (14% higher marks) and higher attendance rates than those in non-daylit schools, including newly built ones (Smiley, 1996). Zenithal lightguides can provide a significant contribution of daylight in buildings where no direct communication with the outside is available. Even if lightguides, whose dimensions are comprised in between those of narrow and long lightguides (daylight chimney) or large and shallow lightwells (daylight shafts), are characterized by important losses (internal reflections absorb an important fraction of the entering light flux), they lead to sufficient horizontal illuminance into underground buildings, in case of high external
1. INTRODUCTION
Since the Industrial Revolution, the discovery of new building materials and technologies has allowed the realization of projects which were considered infeasible in the past. Nowadays, underground transportations and car parks, as well as skyscrapers and huge buildings, are common urban typologies. Modern downtowns being fully exploited in large cities, the need of new spaces leads to a higher exploitation of the underground, where space appears endless. Public car parks and underground stations, but also shopping centers, concert halls and offices, are consequently partially or totally placed underground. Lighting is, of course, one of the biggest problems to be solved in these cases. Since vertical openings are insufficient or not feasible and skylights often unsuitable (multi-storey buildings or thick structural slab, f.i.), artificial lighting is generally found as the unique solution.
†
Author to whom correspondence should be addressed. Tel.: 141-21-6935-557, fax: 141-21-6932-722; e-mail:
[email protected] ‡ EIVD, Route des Cheseaux 1, CH 1400, Yverdon. 117
118
S. C. Molteni et al.
illuminance (tens of thousands lux), even for modest daylight factor values (1–2%).
transmittance of a lightguide (without collector nor diffuser) is given by Zastrow–Wittwer (Zastrow and Wittwer, 1986) as: T 5 R (l ?tanu ) / d eff
(1)
2. MAIN FEATURES OF LIGHTGUIDES
A lightguide is schematically constituted by three main elements: the external collector, the funnel and the internal diffuser (see Fig. 1). Their corresponding tasks are respectively: 1. the collection of the daylight flux; 2. the transportation of the flux; 3. the distribution of the flux into the building. Each of these elements can have different shapes, but internal surfaces should always offer a high coefficient of reflection (anodized aluminium or plastic films providing total internal reflection, for instance). The collector can considerably improve the lightguide performances, allowing a rather high concentration of the light flux at the entrance. The funnel can be straight or curved; its section can have different shapes. Its efficiency depends on many parameters, like the aspect ratio, the section geometry and the internal reflectance. A simple equation that may be used to estimate the
where l is the length of the lightguide, d eff is a generated diameter depending on the section shape (d eff 5pd / 4 for a circular funnel of diameter d). The diffuser contributes to redirect or distribute the light more uniformly in the room and has, then, a secondary role in determining lightguides’ performances. On the top of the lightguide, a transparent dome or a glazing is also placed in order to avoid rain and dust penetration. Its presence obviously influences the lightguide performances, since even transparent layers partially reflect and absorb solar rays. In order to focus on the most important elements of the system, lightguides are always considered in this project without diffuser nor transparent closing; depending on the solutions adopted, therefore, the illuminance levels presented here would be slightly reduced in the reality. It is believed, however, that the luminous performance achieved without these elements are significant enough, to justify this assumption.
3. EXTERNAL COLLECTOR
Fig. 1. Schema of a lightguide (Fontoynont and Paule, 1988).
Different sorts of collectors can be found in the state of the art. They can be fixed or mobile mirror systems, that allow sunlight to be piped into the lightguide. Many different shapes can be found, depending on the goal to achieve. Barcelona’s building ‘‘Club Desportes HispanoFranzes’’, for example, has lightguides equipped with collectors rejecting sunlight in summer (high risk of overheating) and accepting solar rays in winter or mid-seasons. These collectors, adapted to the warm local climate, are made of three plain mirror surfaces whose tilt angles redirect solar rays into the funnel and in a direction parallel to its axis (to achieve a minimum number of reflections) only on the winter solstice at 9 a.m., 12 am. and 15 p.m. At summer solstice, on the other hand, no sunrays are allowed to enter. While these kinds of collectors are mostly used to select sunlight (i.e. the period when sunlight can enter), others can also perform light flux concentration to rise the daylight flux entering in the lightguide. For Central Europe climates, characterized by
Design of anidolic zenithal lightguides for daylighting of underground spaces
frequent overcast conditions, the use of external concentrators could seem not fully appropriate, a plain zenithal opening achieving better luminous performances than a concentrator in case of a perfectly diffuse daylight (Molteni, 1999). The aim of this work was to design an external collector, whose luminous performances are satisfactory all year round, achieving an optical geometric configuration for both clear and cloudy sky conditions. The deliberate choice of a fixed external system clearly makes the problem more complicated, when compared with a mobile tracker. This feature is essential, lightguides being at the end integrated into a building. As a building component, the cost and the frequency of its ordinary handling should be minimized; its life cycle must be comparable with the building one (at least 10 years). Mobile systems necessarily need mechanical and electric components that cannot fulfill these conditions, even if, for a specific sun position, they can provide better instantaneous performances. Following other applications in the field of daylighting (Courret, 1999) and solar concentration (Welford and Winston, 1989), the theory of anidolic optics (non-imaging optics) was used to design the external collector, accounting for its capability of concentrating daylight in a very efficient manner. The method used to design these collectors is given hereafter.
4. DESIGN OF ANIDOLIC COLLECTORS FOR LIGHTGUIDES
CPCs (Compound Parabolic Concentrators) are systems that allow transmitting a determined rectangular optical extent with a moderate number of internal reflections, allowing to achieve an optimum light flux concentration. The CPC’s acceptance sector is chosen as the first step of the collector design (in the meridian section it is defined by two angles [uin sup , uin inf ], ] ] defining the part of the sky which is accepted as light source. Rays entering with an inclination included in this range will be transmitted through the CPC within a given angular interval [uout sup , uout inf ], ] ] while all the others will be reflected back to the entrance. For classical symmetrical CPCs, characterized by a maximal exit angle of it radians, the concentration factor C is given by the following expression:
C 5 1 / sin uin
119
(2)
where the acceptance angle is 2?uin (Welford and Winston, 1989). This means that higher concentration factors are obtained for small values of uin . Small uin values make the collector cumbersome and accepting light from only a small part of the sky (defined by an angular opening of 2?uin ). Two categories of anidolic collector were designed, with the following acceptance angles: Series (1): [158, 958]; Series (2): [158, 678]. All profiles in both series are made of classical CPCs (exit angles are equal to p / 2); all collectors are oriented towards South to view the solar trajectory. The lower admission angle (158) is chosen because obstacles are common in urban contexts † and, in any case, luminances are weak near the horizon. Fig. 2 shows the anidolic collector profiles corresponding to series (1). The first series has a larger input angle and can transmit rays coming also from the zenith, where, for a ‘‘CIE overcast sky’’, the luminance is 3 times higher than on the horizon. Since collectors should be at each moment pointed towards the strongest sky luminances, this first series viewing the zenith supplies higher lighting levels for overcast conditions, comparing with series (2). The second series (see Fig. 3), is more aiming at collecting direct sunlight. Actually, the higher acceptance angle of 678 corresponds to the maximum solar height (noon time, at summer solstice) observed at a latitude of 47.5 LN (Lausanne, CH). The acceptance range is smaller, inducing a higher concentration factor (see Table 1). This solution presents in consequence better performances for clear sky but lower ones for overcast conditions. Thanks to the edge rays’ principle (Ries and Rabl, 1994), the design of particular CPC profiles is reduced to a bidimensional geometric problem, where only two edge rays (corresponding to the two acceptance angles) have to be taken into account. Applying CPC profiles to lightguides, of course, means transforming this bidimensional profile to a tridimensional shape. Two solutions were considered, each one involving constraints on the funnel section form. The first solution (from now on the ‘‘2D’’ solution), consists in extruding the CPC profile and closing it with two †
Of course a lower admission angle of 158 would probably be insufficient in very dense urban contexts.
120
S. C. Molteni et al.
Fig. 2. CPC profiles of series (1) (acceptance sector in the North South meridian: 15–958). On the top is the profile used to realize the 2D collector and on the bottom is reported the CPC used for the 3D symmetrical collector.
plain mirrors: in this case the funnel section should be rectangular (or squared). The second solution (from now on the ‘‘3D’’ solution), needs a symmetrical CPC profile, made through a 3608 rotation around its symmetry axe. This solution leads to a truncated revolution paraboloid, where entrance and exit surfaces are circular and parallel. The funnel section should then be circular too and a connection device should be foreseen. In the 2D solution the CPC profile can be asymmetrical (see Figs. 2 and 3) and then designed directly on the funnel upper surface: in this way, no connection device is needed (but notice
Fig. 3. CPC profiles of series (2) (acceptance sector in the North South meridian: 15–678). On the top is the profile used to realize the 2D collector and on the bottom is reported the CPC used for the 3D symmetrical collector.
that in this case the pipe section needs to be either square or rectangular). In the 3D case, two tilted circles (the collector exit surface and the funnel entrance area), have to be connected with minimum light losses (i.e. no Table 1. Concentration factors [2] of the different collectors designed Collector type
Concentration of series n. 1: 15–958
Concentration of series n. 2: 15–678
2D 3D
2.06 2.44
4.86 5.31
Design of anidolic zenithal lightguides for daylighting of underground spaces
light ray should be reflected back and useless internal reflections should be avoided). The geometrical solution of this problem is given by a truncated portion of torus. The virtue of rotational symmetry allows to reject no radiation, even if the incoming radiation is almost completely diffuse (Collares-Pereira et al., 1995). 5. EXPERIMENTAL VERIFICATION
Scale models of the different lightguides were realized in order to test their performances under different sky conditions. This task was carried out using a scanning artificial sky of new generation (Michel, 1997b). 2D collectors were realized with a foil of anodized aluminium (reflectance: 90%) and wood layers for the profiles cuts. 3D collectors and tows sections were realized thanks to a computer-controlled lathe working on aluminium blocks. Worked surfaces have then be smoothed with glass paper and polished with a solvent in order to attain a better reflectance. Scaled funnels of many different aspect ratios were realized, both with a square section (to be used with 2D collectors) and circular section (to be used with the 3D collectors).
121
The different lightguides were tested following two main goals: 1. to compare their performances (varying the collector and the aspect ratio); 2. to supply a method to design lightguides. Two kinds of indicators were assessed experimentally: candlepower distribution at the exit plane of the zenithal lightguide and illuminance profiles on the ground.
5.1. Candlepower distributions In order to get this first performance indicator, a simple device had to be manufactured (see Fig. 4). It consists in a quarter of a circle inside a cubic box having totally absorbing internal surfaces (black velvet, reflectance ,2%). Eight sensors (illuminance-meters) were fixed on the circle with constant angle step (12.788). A hole was made on the top of the cube where the exit area of a lightguide mode was positioned, allowing its exiting light flux to enter the cube. The proportion of the hole side and circle radius (their ratio is equal to 1 / 8) was considered sufficient to consider the hole as a point source. The intensity of the flux was obtained directly from the illuminance measured by the sensors, thanks to the following relation:
Fig. 4. Schema of the «photogoniometric cube» realized. This device has totally absorbing internal surfaces and was used to get the candlepower distribution of lightguides models.
122
Ik 5 Ek ? R 2
S. C. Molteni et al.
(3)
where Ik is the intensity emitted from the exit hole in the direction relative of the luxmeter k, Ek is the illuminance [lux] measured by the kth sensor, R is the circle radius (i.e. the distance from the hole, constant for all the sensors). When the emitting source (i.e. the exiting surface of the lightguide) is not lambertian, several measures were necessary to have a complete spatial description of the light flux. When a simple circular lightguide without collector is tested under a symmetrical sky (isotropic or CIE Overcast sky), a single measure is sufficient. If the lightguide is not symmetrical (presence of a collector, f.i.) or the sky is asymmetrical (in case of a clear sky, fi.), several measures must be performed because every meridian of the hemisphere behaves differently. In these complex cases, however, only some relevant sections or meridians were considered. Once these candlepower distributions are available in an a dimensionalized form, any lightguide can be described as a single light source. Then it is possible to use a lighting software to calculate the corresponding performances, like the illuminance in a particular room. This kind of simulations would allow a precise description of a specific building: exact photometrical data (such as furniture and wall reflectances), could be defined.
5.2. Illuminance profiles The most intuitive and fastest way for estimating the performances of a lightguide can be achieved through isolux curves or illuminance profiles in vertical sections of the room. Illuminance profiles give immediate information on the lighting level performed at a certain distance from the lightguide. The problem is that an illuminance profile depends on the characteristics of the particular room (the distance between floor and ceiling or the walls’ reflectances, for instance, play an important role in the way the incoming flux is distributed). This means that profiles obtained with certain conditions cannot be valid for any case, while the candlepower distributions are totally independent from the room characteristics and are just specific for a lightguide with a certain aspect ratio under a certain type of sky. Illuminance profiles are mostly influenced by two parameters: the height of the ceiling above the floor and the walls’ reflectances. Simulations carried out by Bouchet and Fon-
toynont showed that variations of 0.3 of the walls’ reflectances caused a diminution of the daylight factor of only about 0.5% (Bouchet and Fontoynont, 1996). The distance between ceiling and floor (from now on ‘‘u’’), on the other side, influences significantly the illuminance profile, both on quantity (lux level) and quality (shape of the profile). Thus, measuring with a single building model implies fixing the proportions between distance u, the funnel length and the dimensions of its section. Comparing lightguides with different section area would mean having several lightguide or building models, realized with different scale factors (changing the scale of the building while keeping the same lightguide has the same effect of creating a new virtual lightguide). Both solutions (especially the realization of many lightguides’ collectors) would increase the cost and the time needed for the experiments in an inappropriate way. The problem was simplified by focusing only on the cases of very large spaces, where walls have no influence on the internally reflected component of the daylight factor. Once border effects are considered negligible, only the floor and the ceiling are influencing the internal illuminance levels. A building scale model was conceived based on this principle. A box of 13130.5 [m] was built, with a hole and a lightguide support on the top (see Fig. 5). Floor and ceiling surfaces have respectively reflectances equal to 0.30 and 0. Walls, on the contrary, are totally absorbing (black velvet with reflectance ,1%), accounting for this assumption. Nine sensors (illuminance-meters) are positioned on the floor, and since this latter is mobile, distance it can be varied arbitrarily without changing the building model. Since sensors have to measure a DF they are not put directly on the floor but lifted at a certain distance from it (depending on the actual scale of the building), corresponding to a 60 cm height in the reality. By changing the distance between the sensors, while moving the box floor (i.e. changing the distance it), several configurations of lightguides can be measured.
6. EXPERIMENTAL RESULTS
Several configurations were analyzed under the scanning sky simulator, leading to many ex-
Design of anidolic zenithal lightguides for daylighting of underground spaces
123
Fig. 5. Schema of the building model with variable scale factor. This device was used to get illuminance profiles and to set up the abaci presented.
perimental results. The most significant ones are given here for different sky conditions † .
6.1. CIE overcast sky Illuminance profiles show that lightguides equipped with anidolic collectors have perform-
ances slightly lower than plain devices (the total flux is roughly reduced by 20%). This is coherent as for strongly overcast conditions daylight is mostly diffuse, collectors reducing the entering flux though their mask effect. Profiles obtained for CIE Overcast skies have typical features, with a single peak, corresponding
Fig. 6. Illuminance profiles abacus obtained for «h /u51.2, CIE Overcast Sky, a /u51 / 5» (where h is the funnel length, u the distance floor–ceiling and a is the side value of square funnels). The two indices specify the type of collector: ‘‘circ 3D 408’’ ] refers to a circular funnel surmounted by a 3D collector with 408 input angle (series 1). †
All comparisons concern a bidimensional case: illuminance profiles refer to the North–South axis.
124
S. C. Molteni et al.
to the sensor positioned exactly under the funnel axis (point E), and illuminance levels rapidly decreasing as soon as the distance from point E increases (see Fig. 6). In absence of external collector, the profiles are perfectly symmetrical, since both the sky luminance distribution and the pipe geometry are symmetrical. A symmetry is recognizable also for lightguides with collectors: this is also normal since a CIE Overcast Sky provides a pretty uniform (if compared to a CIE Clear Sky) light distribution and perfectly uniform light distributions are transmitted by CPCs on the exit plane, showing lambertian features. CIE Overcast Sky experiments show that the presence of an anidolic collector over the zenithal lightguide is acceptable for overcast conditions, the daylight factor being reduced however from 3.5 to 2.2% underneath the device (on the system axis).
6.2. CIE clear sky The significant improvement of illuminances, due to the external anidolic collector, is illustrated in Fig. 7. At summer solstice (at noon), the total flux is four times larger, compared to a lightguide without external device. Not only peak levels are increased (illuminance ratio of 29% instead of
15%), but also the average illuminance is highly improved: under the lightguide, for example, the illuminance ratio grows from less then 1% up to 17%. The anidolic collectors contribute to the improvement of the illuminance ratio even for the winter solstice (illuminance ratio moves from 2.2 to 5.2%); Fig. 8 illustrates this. A second observation can be made when comparing with overcast profiles: for clear sky, illuminance has two or more peaks placed on both sides of the lightguide. The explication is easy if we consider the simplified case of a square pipe with the sun set on its axis: the problem is then bidimensional. Light is coming from a punctual source (the sun) so that rays are all incident with the same inclination (that is the solar height). The entering light flux is split in two parts and, after several reflections, reaches the floor in two different areas, creating two different light spots, at each side of the lightguide. The central point placed on the axis of the funnel gets now less daylight than the rest; the main contribution for it being the zenith, which shows lower luminances for clear sky conditions. Figs. 9–11 show another important feature of anidolic collectors, illustrated by the so-called partial daylight factors (Michel, 1997a), which
Fig. 7. Illuminance profiles abacus obtained for «h /u51.2 CIE Clear Sky, 21 / 6, noon, a /u51 / 5» (where h is the funnel length, u the distance floor–ceiling and a is the side value of square funnels).
Design of anidolic zenithal lightguides for daylighting of underground spaces
125
Fig. 8. Illuminance profiles abacus obtained for «h /u51.2 CIE Clear Sky, 21 / 12, noon, a /u51 / 5» (where h is the funnel length, u the distance floor–ceiling and a is the side value of square funnels).
Fig. 9. Stereographic projection of the sky seen from point E (i.e. under the pipe axis), through a simple circular pipe (h /u 5 1.2, a /u 5 1 / 5). Values in each zone represent the relative «partial daylight factor», that is the influence of that zone on the DF of point E. Almost the totality of the light received by the point E comes from the zenith.
126
S. C. Molteni et al.
Fig. 10. Stereographic projection of the sky seen from point E (i.e. under the pipe axis), through a square lightguide (h /u 5 1.2, a /u 5 1 / 5), with an anidolic collector 2D, series 15–958, Point E receives light from more zones of the sky (especially on the N–S axis), than without any collector (compare with Fig. 9).
Fig. 11. Stereographic projection of the sky seen from point E (i.e. under the pipe axis), through a circular lightguide (h /u51.2, same area as square with a /u51 / 5), with an anidolic collector 3D, series 15–958. A 3D collector diffuses the entering light more than the 2D case. The 3D collector allows the point E to get light from more zones than the 2D and also spread around the N–S axis.
Design of anidolic zenithal lightguides for daylighting of underground spaces
‘‘measure’’ the contribution of each zone of the sky dome to the illumination of a given point (point E on the axis of the lightguide in this case). 3D collectors show profiles for clear and overcast sky which are closer: the B point remains one of the best illuminated ones and the two-peak structure is not recognizable. This can be explained by the higher diffusion of the lightrays which is achieved by the 3D profiles compared to the 2D profiles. An important feature has to be underlined: even if a better sampling was provided (17 sensors were placed instead of 9), experiments under clear sky are not as reliable as the previous ones. As it was said before, a punctual source creates significant discontinuities on the illuminance profile generated: if the sensor is positioned just inside or just outside the light spot, measures can vary from extremely high to almost zero. The use of a scanning artificial sky and of the 145 zone method (Michel, 1997b), considerably smoothes this risk (zones have a step of 108, i.e. the light source is proportionally more extended than the real sun), but nevertheless, measures have to be read carefully.
6.3. Comparison of anidolic collectors Illuminance profiles showed that more open collectors (2D or 3D but with acceptance sector of 15–958), offer preferable performances than those characterized by a narrow input sector (15–678). Even if peak values are sometimes lower (at winter solstice, f.i.), it must be emphasized that open collectors increase illuminances in a more uniform way. At noon of summer solstice, for example, peaks relative to 2D open and close collectors are almost equal, while the minimum illuminance ratio under the lightguide is 17% for the open and only 7% for the ‘‘closer’’ one. According to the theory, this should be even more evident for overcast conditions, even if in this case measures show only a very slight difference. 7. PRACTICAL DESIGN METHOD
Even if the only way to assess in an accurate way illuminance levels for lightguides implemented on a particular room is using the corresponding candlepower distribution under the funnel, it appears in practice that only very few architects or building engineers have the skills needed to use the corresponding lighting simulation software. More, this degree of precision would be useless in a phase where many building design parameters are still vague. It is exactly in this moment, however, when the
127
design of a lightguide should be considered, in order to avoid farther interferences with the building structure or with the technical equipment. Schematically, only two important characteristics of the room must be known in the first part of the project to achieve this design: 1. u (distance floor–ceiling); 2. 1 (length of the funnel). The distance of the ceiling from the floor, in fact, depends on the typology and regulation giving precise constraints, while the length of the lightguide is generally determined by the morphology of the site. Data needed, on the other side, are: 1. the area of the pipe’s section (A); 2. the distance between lightguides (D); 3. the illuminance requirements. These three parameters are sufficient to have a rough idea of the cost of the installation and of the lighting contribution of the lightguide (D is directly related to the number of lightguides). Distance D is chosen first, starting from the illuminance profiles, depending on the required level and on the degree of uniformity desired. Since only u and l values are available at the beginning, abacuses are labeled with l /u and provide profiles relative to devices with different A (l is constant, so the aspect ratio is varying). Thus, a certain lightguide can be chosen and D is calculated.
7.1. Example of application We just restrict our example to a bidimensional situation, neglecting the dimension on the East– West direction. The aim is to illuminate a subway station with the following characteristics: l53 m; u52.5 m; L59 m, where L is the depth of the unit considered (on the North–South direction). A minimum DF of 1% is required † for the most penalized case (CIE Overcast Sky). The ratio l /u is equal to 1.2, leading us to the corresponding abacus, relative to a CIE Overcast Sky. The following lightguide could be chosen as a base case, defining a corresponding illuminance profile: l 5 u / 3.3, collector CPC 2D 15–958. Once an illuminance profile is determined, D can be calculated: it is the distance from the funnel axis, which corresponds to a DF of 0.5% (since we require a minimum daylight factor of 1% and two different lightguides sum their ef†
For a very cloudy winter day the external illuminance is of about 10000 [lux]. Assuming 100 [lux] a sufficient illuminance for a subway station, we calculate the least favorable (i.e. the highest) daylight factor required as the ratio of these two illuminances (0.01).
128
S. C. Molteni et al.
fects). D(u 5 2.5 [m] is obtained in this case. In conclusion, we have considered a system of lightguides with l50.75 m (i.e. 2 lightguides on the 9 m depth), and spaced with a step of 5 m (i.e. 2?D). In order to estimate the daylighting autonomy of such a system, a simulation during a whole year was made under the scanning sky simulator, using the meterological data relative to Geneva for 1994. Assuming working hours from 9 a.m. to 5 p.m., the autonomy of the lightguides was calculated, considering different comfort setpoints (see Table 2). The results reported in the figure show that if 100 lux are required for underground passages, a good autonomy is provided also at a distance of 2 m from the lightguide axis, reaching values of 24.2% and 12.7% over the whole year. 8. CONCLUSION
The theory of anidolic optics (non-imaging optics) was used to design external collectors for lightguides, the purpose being daylighting underground spaces. A series of scaled models of the devices was tested under a scanning sky simulator. The experimental results show that these anidolic collectors improve the performances of simple lightguides on quantitative, as well as on a qualitative basis. The collector showing the optimal performance is characterized by 808 input acceptance angle: it has a reasonable performance under overcast skies (the transmitted flux is about 80% of a plain lightguide without collector), compensated by considerable gains under clear conditions Table 2. Autonomy of the natural lighting provided by the lightguide foreseen in the example a Min [lux]
Max [lux]
C: 2 m North [%]
D: 1m [%]
E: pipe axis [%]
F: 1 m [%]
G: 2 m South [%]
50 100 100 150 200 300 400
20 000 20 000 10 000 20 000 20 000 20 000 20 000
44.7 24.2 24.2 17.4 14.1 8.4 6.7
88.8 74.6 74.1 63.4 52.4 36.3 25.5
94.7 90.1 89.2 83.1 76.8 66 56.5
84.4 67.6 67.2 53.6 43.2 28.1 20.9
27.2 12.7 12.7 8.6 6.7 4.8 4.3
a
Autonomy values are calculated at different distances (sensors are placed on a North–South axis: sensor E is exactly under the lightpipe, sensor C and D are, respectively, 2 m and 1 m North from E. while sensor F and G are respectively 1 m and 2 m South from E). Autonomy values are calculated over a whole year (data relative to Geneva, year 1994), as the total percentage of time in which the conditions specified in the first two columns (minimum and maximum illuminance) are satisfied. The time horizon (corresponding to the 100% of the time) is the typical working day: it goes from 9 a.m. to 5 p.m.
(the flux is four times larger, at summer solstice, noon time). This corresponds to an excellent compromise for a fixed device. Simple and readyto-use abacuses were finally provided to the practitioners, in order to support the design of lightguides integrated in buildings. Lightguides are shown to be interesting devices for introducing natural daylight into buildings. They are not intended to be substitutive but complementary to artificial lighting. Their benefit, apart from energy savings, concerns an increased visual comfort, both under a physiological and a psychological point of view.
NOMENCLATURE T R A d eff l u u: uin C Ik Ek D DF
transmittance (dimensionless) reflectance (dimensionless) area of the pipe’s section (m) generated diameter (m). It depends on the section geometry (Zastrow and Wittwer, 1986) length of the funnel (m) distance floor–ceiling (m) solar height (radians) acceptance semi-angle of a CPC (radians) concentration factor (dimensionless) intensity emitted in the direction relative of the luxmeter k (Cd) illuminance measured by sensor k (lux) distance between lightguides (in) daylight factor (dimensionless)
Acknowledgements—The authors are indebted to Sergio Croce and Enrico De Angelis (Politecnico di Milano) for their support and Pierre Loesch (EPFL) for the technical assistance.
REFERENCES Bouchet B. and Fontoynont M. (1996) Daylighting of underground spaces: design rules. Energy and Buildings 23, 293–298. Collares-Pereira M., Mendes J. F., Rabl A. and Ries H. (1995) Redirecting concentrated radiation. SPIE 2538, 131–135. ` ´ naturel. Courret G., (1999) Systemes anidoliques d’ eclairage Doctoral Thesis n. 2026, EPFL, Switzerland. Fontoynont M. and Paule B. (1988) Sunlight techniques developed for the school of Colioure, France. ASES 88, Cambridge. Liberman J. (1991). Light–Medicine of the Future: How We Can Use It To Heal Ourselves Now, Bear and Co. Publ, Santa Fe, USA. ´ ´ ´ des Michel L. (1997a) Methode experimentale d’ evaluation ˆ performances lumineuses de batiments. Doctoral Thesis n. 2042, EPFL, Switzerland. Michel L. (1997b) Utilisation multizonale d’un ciel artificiel a balayage. In Proceedings of CISBAT 97, EPEL, Switzerland. Molteni S. (1999) Applicazione della teoria anidolica ai sistemi di captazione e trasporto della luce naturale. Degree thesis, Politecnico di Milano, Italy. Ries H. and Rabl A. (1994) Edge Ray Principle of NonImaging Optics, vol. 11. Optical Society of America.
Design of anidolic zenithal lightguides for daylighting of underground spaces Smiley F. (1996) Students delight in daylight. International Association for Energy Efficient Lighting Newsletter 5(2), 11–12. Welford W. T. and Winston R. (1989). High Collection Nonimaging Optics, Academic Press, New York.
129
Zastrow A. and Wittwer V. (1986) Daylight with mirror lightguides and with fluorescent planar concentrators. First results from the demonstration project Stuttgart-Hohenheim. In Proceedings, SPIE Symposium, 11–22 August, San Diego, USA.