Water Research 36 (2002) 3165–3169
Research note
Effect of ultrasound on the removal of copper from the model solutions for copper electrolysis process Robina Farooqa,*, Y. Wanga, F. Lina, S.F. Shaukatb, J. Donaldsonc, A.J. Chouhdaryc a
College of Resources and Environmental Engineering, East China University of S & T, Shanghai 200237, China b Department of Physics, East China University of S & T, Shanghai 200237, China c Institute of Physical and Environmental Sciences Brunel University, Uxbridge, UB8 3PH, UK Received 23 July 2001; received in revised form 21 November 2001; accepted 4 December 2001
Abstract A novel combination of an ultrasonic field with electrolysis for the removal of copper is studied. In the ultrasonic field, cavitation acts as jets and agitates the solution and breaks the barrier layer between the cathode surface and the bulk of the solution, thus increases the metal deposition on the cathode surface. The results show that an ultrasonic field is successful for the removal of low copper concentrations in solution. r 2002 Elsevier Science Ltd. All rights reserved. Keywords: Ultrasound; Copper removal; Electrolysis; Ultrasonic electrolysis
1. Introduction One of the most promising areas for recycling nonferrous metals undoubtedly lies with the metal finishing and electronics industries. The volume of metal-containing waste water from these industries, without providing new ore sources, can yield metal concentrations high enough to favour recovery or removal. The adsorption, cementation, electrolysis, ion exchange, membrane separation, precipitation and solvent extraction techniques have been applied to the separation and recovery of metals from aqueous solutions [1,2]. The benefits of electroplating under the influence of ultrasonic field have been studied over the last 30–40 years [3–6]. Ultrasound affects on electrochemical factors such as current efficiency and energy consumption. The microhardness, wear, rate of deposition, grain size, brightness, porosity, surface topography and internal stress of electrodeposits have been studied [5]. Here, in this research work a novel technique of
*Corresponding author. Tel.: +86-21-6424-8568. E-mail address: robina
[email protected] (R. Farooq).
ultrasound combined with an electrochemical cell has been used successively to recover copper from its dilute solutions. The work was focused on studying the effects of ultrasonic fields on the electrodeposition of copper in the following main areas: 1. Effect of ultrasound on the removal of copper 2. Effect of concentration of copper 3. Effect of cathode type.
2. Materials and methods Electrodeposition of copper with and without an ultrasonic field was carried out in a 24 cm 11 cm 31 cm (l w h) perspex reaction vessel with walls of 0.6 cm thickness. The reaction vessel was designed to be placed in an ultrasonic bath and to accommodate 5 electrodes with 12 mm spacing, shown in Fig. 1. The ultrasonic bath used was a Camlab Transonic Series T780/H with a volume of 12.75 dm3 operating at a frequency of 35 kHz. Detergent was added to the ultrasonic bath solution to lower the surface tension of the water. The reaction vessel was
0043-1354/02/$ - see front matter r 2002 Elsevier Science Ltd. All rights reserved. PII: S 0 0 4 3 - 1 3 5 4 ( 0 1 ) 0 0 5 4 6 - 2
3166
R. Farooq et al. / Water Research 36 (2002) 3165–3169
Fig. 1. Layout of the electrolytic reaction vessel used with ultrasound.
designed in a way that all the cathodes and anodes surface areas were below the level of the water in the ultrasonic bath. Two mesh platinum coated titanium anodes, along with one mesh titanium or stainless steel plate cathode were used [7]. Different concentrations ranging from 100 to 500 mg/l Cu2+ were prepared from reagent grade copper sulphate (CuSO4.5H2O) with 0.1 mol dm3 H2SO4 in distilled water. Five litres of aqueous solution were used in each experiment. The current used was 1.0 Ampere [8,9]. The tests were carried out in both the sonicated and nonsonicated fields. The temperature and voltage during the electrolysis process in the sonicated solutions, was measured at one hour intervals for 8 h. In the sonicated field, voltage and temperature were constantly increased, in order to maintain the same thermal conditions for nonsonicated solutions, the temperature was adjusted to match those during the sonicated process. The energy consumed during the combination of ultrasound and electrolysis process is the total energy i.e., the energy necessary for ultrasound generation and for electrolysis process. In order to determine the effect of cathode types two types of cathode mesh titanium cathode or stainless steel plate cathode were used separately. The conditions of temperature, current, volume and molarity of acid were constant in every experiment and the concentrations were changed in each couple of sonicated and nonsonicated experiments. For the detection of copper concentration in the solution, the standard method of atomic absorption is used throughout this work. To examine and compare the effectiveness of electrolysis process, the following parameters were compared for each experiment:
(a) The percentage removal, a (%) (b) The current efficiency, Z (%) (c) The energy consumption, W (kWh kg1), where, actual deposit 100 a¼ initial weightðgÞ actual depositðgÞ Z¼ 100 therotical depositðgÞ voltage current time W¼ weight depositedðgÞ
3. Results and discussion 3.1. Effect of ultrasound on the removal of copper A set of experiments was carried out to investigate the effect of sonicated field on the percentage removal of copper from 100 mg/l and 500 mg/l solutions using mesh cathode and two platinised titanium anodes. The electrolysis results are plotted as log C vs. time (t) in Fig. 2. The results of electrolysis assuming first-order of the reaction kinetics,
d½Cu2þ ¼ k½Cu2þ dt
are listed in Table 1. The electrolysis results revealed that the rate constants (k) are larger under sonicated fields than under nonsonicated ones. This indicates that the electrolysis rate is higher in sonicated field. The difference of electrolysis rate constants (k) with and without ultrasonic field in both concentrations
R. Farooq et al. / Water Research 36 (2002) 3165–3169
showed that the value of k in 100 mg/l solution is larger than in 500 mg/l solution. So, we can conclude that electrolysis with ultrasonic technology is more effective in lower concentrated solution than in higher concentrated solution. Talking about half-life of copper in different concentrations, the results showed that in 100 mg/l solution difference of half life time is almost twice in nonsonicated than sonicated field. But in higher concentration (500 mg/l) the half-life time is only 13 times more in nonsonicated field compared to sonicated one. So, the function of ultrasonic technique is more suitable for lower concentrated solution. The results showed that during electrolysis in sonicated field (ultrasound on), the percentage removal (aCu ) and current efficiency (ZCu ) were more as compared to nonsonicated field (ultrasound off). The energy consumption WCu values were lower in the case of sonicated field compared to nonsonicated for 100–500 mg/l concentrations. For very dilute solution (100 mg/l) concentration, during the removal of copper, under sonicated condition, WCu was reduced to half compared to that in nonsoincated field as shown in Table 2. Any change in the removal rate of metal deposition from dilute solution can only occur due to either a change in the diffusion layer thickness or a change in the limiting current density. The problem of thinning down the diffusion layer was solved by ultrasonically agitated 2.5
Log C
2 1.5
US off 100
3.2. Effect of copper concentration In the nonsonicated field, the aCu values were increased with increasing copper concentration and in the sonicated field, the aCu values were equal or >95%. In sonicated and nonsonicated conditions, the ZCu values were increased with increasing copper concentration. The ZCu in sonicated solution was again more as compared to nonsonicated solutions as shown in Fig. 3. The WCu in both sonicated and nonsonicated conditions were high at very low copper concentration, i.e., 100 mg/l but decreased with increasing concentration. However, this consumption is less in sonicated solution as compared to nonsonicated solution. It is shown in Fig. 4. The changes in aCu ; ZCu and WCu at different concentrations of Cu2+ in sonicated and nonsonicated fields are listed in Table 2. The effect of ultrasonic field on the aCu of copper from 500 mg/l solution showed a much smaller difference in values between the sonicated and nonsonicated
Con. (mg/l) Ultrasound on
US on 500
0.5
bath. The compression and rarefaction cycles in an ultrasonic system produce alternative regions of high and low pressure forming vacuum bubbles. These bubbles rapidly grow and implode generating high pressure/temperature hot spots which in turn reduce the diffusion layer thickness. Thus, the transport of the dilute metal species of Cu2+ is facilitated and results in increased percentage removal and current efficiency and decreased the energy consumption over conventional standard electrochemical cell.
Table 2 Effect of copper concentration using mesh cathode in the presence and absence of ultrasonic field after 8 h of electrolysis
US on 100
1
US off 500
0 0
2
3167
4
6
8
10
Time (hour)
Fig. 2. Effect of ultrasound on the electrolytic removal of copper.
100 200 300 400 500
Ultrasound off
aCu (%) ZCu (%) WCu
aCu (%) ZCu (%) WCu
94.6 95.5 98.3 97.5 97.3
55.1 63.1 93.0 93.0 93.1
4.9 10.1 15.5 20.6 25.6
24.5 11.3 10.5 8.8 7.05
2.9 6.6 14.7 18.8 24.5
51.49 18.03 11.47 10.28 7.5
Table 1 Effect of ultrasound on copper removal by electrolysis Initial Concent. C0 (mgl1 )
100 500
Ultrasound on
Ultrasound off
Half life time t1=2 (min)
Electrolysis Constant k (min1)
Correlation coefficient
Half life time T1=2 (min)
Electrolysis constant k (min1)
Correlation coefficient
240 120
2.19 103 3.38 103
0.948 0.984
420 180
6.75 104 2.52 103
0.986 0.989
Current Efficiency
60
US US US US
50 40
o n (1 0 0 ) o ff (1 0 0 ) o n (5 0 0 ) o ff (5 0 0 )
30 20 10 0
0
2
4
6
8
10
Time (h)
Energy Consumption
60
US on (100) US off (100) US on (500) US off (500)
50 40 30 20 10 0 2
4
Time (h)
110 100 90 80 70 60 50 40
Plate, US on Mesh, US on Plate, US off Mesh, US off 0
Fig. 3. Effect of ultrasonic field in combination with mesh cathode on the ZCu of copper from 100 and 500 mg/l solutions.
0
Percentage Removal
R. Farooq et al. / Water Research 36 (2002) 3165–3169
3168
6
8
10
Fig. 4. Effect of ultrasonic field in combination with mesh cathode on the WCu of copper from 100 and 500 mg/l solutions.
fields as compared to the data for the concentration of 100 mg/l. The reason is that the process of electrolysis requires the transport of ions from the bulk of the solution to the surface of the electrode. In concentrated solutions there are plenty of ions approaching the surface of the electrodes but in dilute solutions there are few ions reaching to the electrode surface. In this situation, all three processes, i.e. diffusion, migration and convection contribute to ion-transfer conditions. If the concentration of ions reaching at the electrode is small compared to the concentration of the ions in the solution, as is the case in dilute solutions, then the effects of ionic migration and convection are negligible compared to diffusion. The force of adhesion between the electrodes and the layer of the solution reduces the hydrodynamic flow in the immediate vicinity of the electrodes to zero. Thus there is no mass transport by convection in this region. Migration by itself is not sufficient to transport ions across the barriers of the boundary layer to the surface of the electrode. The electrolyte concentration is the controlling and limiting factor in the electrolysis process. In dilute solutions the only way in which ion can be transported across the boundary layer to the electrodes is by diffusion. The rate of diffusion in the boundary layer can be increased by the use of ultrasonic field. It transfers the ions from the bulk of solution to the surface of electrode during the process of acoustic cavitation. Acoustic cavitation is the growth and
100
200
300
400
500
600
Concentration (mg/l) Fig. 5. Comparison of cathode type (Plate and Mesh) in the absence and presence of ultrasonic field on the percentage removal of copper after 8 h of electrolysis.
collapse of bubbles in solution induced by ultrasonic waves which impose a sinusoidal pressure variation in the transmitting medium, alternately decreasing (rarefaction) or increasing (compression) the local density of the molecules. Microscopic bubbles grow in size during the ‘‘rarefaction’’ half cycle of the sound wave and implode during the compression half cycle on the surface of the cathode [10]. This suggests that the ultrasonic field acts as an agitating medium which is effective at more dilute concentrations, where the diffusion problem is greatest due to less number of ions near the surface of cathodes and thus increase the rate of removal. In more concentrated solutions, a large number of metal ions are already present near the cathode surface, in the ultrasonic field the movement of ions are also increased towards the cathode surface and thus the number of collisions between the already present ions and the incoming ions from the bulk of the solution increased which in turn decrease the rate of removal and deposition.
3.3. Effect of cathode type The results on aCu ; ZCu and WCu in different types of cathodes during sonicated and nonsonicated fields showed that mesh cathode was better than plate cathode for the removal of copper from 100 to 500 mg/l solutions as shown in Figs. 5–7, respectively. It is known that the deposition of metal on the cathode surface is affected by the stirring rate. High stirring rates increase the percentage removal because of more efficient mixing of the solution during electrolysis process. This mixing breaks the diffusion layer around the cathode surface and aids movement of cations towards the surface of the cathode (Walker, 1990). This mixing rate is higher in mesh cathode compared to plate cathode, which in turn increases the percentage removal. Secondly, the higher removal rate of copper on mesh cathode because of high surface area of the metal compared to plate cathode.
Current Efficiency
R. Farooq et al. / Water Research 36 (2002) 3165–3169 30
Plate, US on
25
Mesh, US on Plate, US off
20 15
Mesh, US off
10 5 0 0
100
200
300
400
500
600
Concentration (mg/l)
Energy Consumption
Fig. 6. Comparison of cathode type (Plate and Mesh) in the absence and presence of ultrasonic field on the current efficiency of copper after 8 h of electrolysis.
70
Plate, US on
60
Mesh, US on
50
Plate, US off
40
Mesh, US off
30 20
3169
(1) An electrolytic reactor, combined with an ultrasonic field provides higher ion-transfer conditions during electrolysis by breaking up the barrier layer at the electrode, thus enabling metal to be removed efficiently from dilute solution. It was observed that the energy cost reduced to half compared to general electrolysis. (2) The use of sonication as an agitating medium proved much more effective for the removal of copper at very dilute concentrations (100 mg/l), compared with less dilute concentrations (500 mg/ l). The energy consumption also decreased with increasing copper concentration. (3) The rate of copper deposition and current efficiency values for mesh cathode were higher than that for plate cathode, while mesh cathodes consumed less energy than plate cathode irrespective the presence or absence of ultrasonic field. These results show that by applying this ultrasonic technique the beneficial effects of increased deposition rates can be achieved from dilute solutions and in this way, the stringent environmental irregularities can be overcome.
10 0
0
100
200
300
400
500
600
Concentration (mg/l) Fig. 7. Comparison of cathode type (Plate and Mesh) in the absence and presence of ultrasonic field on the energy consumption of copper after 8 h of electrolysis.
The results showed that ultrasonic field is effective in breaking diffusion layer. The comparison can be done between the mixing devise (mesh cathode) during simple electrolysis process in the absence of ultrasonic field with plate cathode in the presence of ultrasonic field. The results revealed that the percentage of removal in the presence of ultrasonic field is more as compared with the mesh cathode during simple electrolysis (Fig. 5). This can be explained by the fact that in the ultrasonic field when cavitation occurs near the cathode surface, enormous energy released on bubble collapse which force ion species towards the electrode.
4. Conclusions The conclusion of research on the novel technology of electrolysis with an ultrasonic field is summarised as follows:
References [1] Nippon Minning, 1986. Electrolytic copper removal from solution. Japanese Patent 57185996. [2] Bin W, et al. Comprehensive utilization of residues produced in the hydrometallurgical processing of copper anode slimes. Kuangye Gongcheng 1986;6:46–9. [3] Prasad PBSNV, Vasudevan R, Seshadri SK. Recovering molybdenum and copper from wastewater in producing phalocyanine pigments. Tran Indian Inst Met 1993;46: 44–7. [4] Zhang HH, Coury LA. Copper recovery from copper or its alloy treating solutions. Anal Chem 1992;65(11):1552–8. [5] Prasad PBSNV, et al. Seeding of electroless copper waste for copper removal and recovery as elemental copper. J Mater Sci Lett 1994;13:15–6. [6] Seryanov YV, Kvyatkovskaya LM, Grishanin VA. Electrolytic recovery of precious metals from dilute solutions. Russian J Electrochem 1994;30(3):364–5. [7] Lickiss PD, et al. Fundamental aspects of sonochemistry. Chem Br 1996;73:47–51. [8] Hart EJ, Henglein A. Sonochemistry of aqueous solutions: H2–O2 combustion in cavitation bubbles. J Phys Chem 1993;91:3654–6. [9] Cataldo F. Electrochemical treatment of bimetallic wastes. J Electroanal Chem 1992;332:325–31. [10] Mason TJ. Sonochemistry: the uses of ultrasound in chemistry. The Roy Soc Chem 1990;47:60–1.