Estimation of musculotendon kinematics under controlled tendon indentation

Estimation of musculotendon kinematics under controlled tendon indentation

Journal of Biomechanics ∎ (∎∎∎∎) ∎∎∎–∎∎∎ Contents lists available at ScienceDirect Journal of Biomechanics journal homepage: www.elsevier.com/locate...

1MB Sizes 3 Downloads 34 Views

Journal of Biomechanics ∎ (∎∎∎∎) ∎∎∎–∎∎∎

Contents lists available at ScienceDirect

Journal of Biomechanics journal homepage: www.elsevier.com/locate/jbiomech www.JBiomech.com

Estimation of musculotendon kinematics under controlled tendon indentation Matthieu K. Chardon a,n, Yasin Y. Dhaher a,b,c, Nina I. Suresh b, Giselle Jaramillo b, W. Zev Rymer a,b,c a

Department of Biomedical Engineering, McCormick School of Engineering and Applied Science, Northwestern University, Evanston, IL, USA Sensory Motor Performance Program, Rehabilitation Institute of Chicago, Chicago, IL, USA c Department of Physical Medicine and Rehabilitation, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA b

art ic l e i nf o

a b s t r a c t

Article history: Accepted 21 July 2015

The effects of tendon indentation on musculotendon unit mechanics have been left largely unexplored. Tendon indentation is however routinely used in the tendon reflex exam to diagnose the state of reflex pathways. Because muscle mechanoreceptors are sensitive to mechanical changes of the musculotendon unit, this gap in knowledge could potentially impact our understanding of these neurological exams. Accordingly, we have used ultrasound (US) imaging to compare the effects of tendon indentation with the effects angular rotation of the elbow in six neurologically intact individuals. We used sagittal ultrasound movies of the biceps brachii to compare length changes induced by each of these perturbations. Length changes were quantified using a pixel-tracking protocol. Our results show that a 20 mm indentation of the distal tendon is broadly equivalent to a 15° elbow rotation. We also show that within the imaging window the strain differences between the two stretching protocols are statistically insignificant. Finally, we show that there exists a significant linear relationship between the two stretching techniques and that this relationship spans a large rotational angle to indentation depth. We have used a novel tendon probe to administer controlled tendon indentations as a way to characterize musculotendon kinematics. Using this probe, we confirm that tendon indentation can be physiologically equated with joint rotation, and can thus be used as an input for muscle stretching protocols. Furthermore, this is potentially a simpler and more practical alternative to externally imposed angular joint motion. & 2015 Elsevier Ltd. All rights reserved.

Keywords: Tendon indentation Joint rotation Kinematics Musculotendon unit Skeletal muscle stretch

1. Introduction In the course of the standard neurological exam, a clinician records myotatic reflexes by stretching muscles in two ways: by rotating a joint, or by tapping a tendon with a reflex hammer. Both techniques stretch the muscle, and both stimulate the muscle receptors that trigger the reflex responses. To the best of our knowledge, however, the kinematic relationship between each stretching paradigm has not been explored. Furthermore, the muscle kinematics recorded in response to tendon indentation alone are also largely unexplored, potentially hindering our basic understanding of stretch reflex mechanisms.

n Correspondence to: Rehabilitation Institute of Chicago, 345 East Superior St, Suite 1714, Chicago, IL 60611, USA. Tel.: þ1 3122381173; fax: þ1 3122388121. E-mail address: [email protected] (M.K. Chardon).

We now know that the tendon reflex response is dependent on several controllable factors, such as the amplitude of the tendon tap and the frequency with which the tap is delivered (Voerman et al., 2005). More recently, we have shown that controlling the depth of tendon indentation prior to the tap also elicits reflex patterns resembling ones found for progressive whole limb rotation (Chardon et al., 2014). Accordingly, there is potentially a strong correlation between the parameters impacting the tendon reflex and the kinematics of the muscle prior, during and after the tendon tap. However, we do not currently know how much stretch is delivered by tendon indentation, and how this stretch compares with that generated by a standard angular joint rotation. Presently, global musculotendon unit movements are routinely studied using ultrasound (US) medical imaging, because of its unparalleled ability to record tissue motion in vivo. However, the majority of the studies stretch a muscle using controlled joint rotation (Blemker et al., 2007). In contrast, tissue indentation protocols

http://dx.doi.org/10.1016/j.jbiomech.2015.07.024 0021-9290/& 2015 Elsevier Ltd. All rights reserved.

Please cite this article as: Chardon, M.K., et al., Estimation of musculotendon kinematics under controlled tendon indentation. Journal of Biomechanics (2015), http://dx.doi.org/10.1016/j.jbiomech.2015.07.024i

M.K. Chardon et al. / Journal of Biomechanics ∎ (∎∎∎∎) ∎∎∎–∎∎∎

2

are often used to assess local muscle mechanics. When applied in cadaveric specimens (Palevski et al., 2006; Van Loocke et al., 2006, 2008) or on muscle belly (Iivarinen et al., 2011; Leonard et al., 2001; Uchiyama et al., 2000), the indenter is used to record compression force and the associated tissue displacement, recorded either from the indenter motion, or from imaging techniques (Moerman et al., 2011; Zheng and Mak, 1996). While extremely important, these indentation paradigms can only provide insights about local rather than global musculotendon unit mechanics. There is also no way currently to integrate findings drawn from joint rotation with those derived from tissue indentation. In this study, we explore and compare whole muscle kinematics of the biceps brachii (BIC) muscle under tendon indentation and during a standard joint rotation at the elbow. We plan to use US imaging as a tool to record internal muscle deformation. We further seek to demonstrate whether muscle length changes during tendon indentation can be equated with joint rotation, and whether such tendon indentation produces physiologically meaningful changes in muscle length. We chose the BIC as our model system because it has an easily accessible distal tendon. For our muscle kinematics measures, we used B-mode US imaging.

US-T3

US-T2 US-T4

US-T1

Tap-T2

US-T5

Tap-T1

Arm-R1 Tap-T4 Tap-T3

2. Method 2.1. Participants

US-Pitch

FUS

US-Pitch

Imag e Plan e

Six neurologically intact individuals, of age 31 75.2 years, were recruited and their dominant side was tested once. All participants gave informed consent via protocols approved by the Institutional Review Board under the Office for the Protection of Human Subjects at Northwestern University. 2.2. Experimental setup

Muscle US-Yaw

Each subject was seated in a Biodex chair and the forearm was braced to a custom arm rotation device (Fig. 1A). The subject’s position was adjusted such that shoulder-abduction was 10°, shoulder-flexion 10°, elbow-flexion was 120° and forearm-supination was 0°. The arm brace was also adjusted such that the axis of rotation of the elbow was collinear to the axis of rotation of the rotation device. The US probe and tendon tapper were placed near to the distal muscle–tendon junction of the BIC, identified using US and marked by tape (Fig. 1). Specifically, using the 8 adjustments of a custom US probe holder, we placed the probe orthogonal to the shorter axis of the BIC (sagittal-plane), closest to the distal tendon at 1 cm distance. We then used the rotational adjustments to increase the reflectivity of the tissue below and further ensured that the muscle could be tracked throughout the range of angles. We then placed the tendon tapper such that its tip indented the distal end of the BIC muscle at an angle of attack 90° to the humerus. Each protocol had 5 trials. In a single rotation trial, the forearm was extended at a PID controlled velocity (0.08 rad/s) from 120° elbow flexion to 150° and then rotated back after a 5 s pause. For a single indentation trial, the tendon tapper was lowered onto the tendon at a PID controlled velocity (5 mm/s) from skin (0 mm) to a distance of 20 mm and was then returned after a 5 s pause. Subjects were instructed to keep their muscles quiescent during the trials. The US movies were collected using a GE-Logiq9-R6.0.5 and a GE-M12L probe set at a frequency of 14 MHz, gain of 63 dB at a recording depth of 30 mm and width of 50 mm. For each rotation and tendon indentation cycle, we stored for later analysis (533  436) grayscale DICOM movies. We used Matlab-xPC-2011a to collect, to control the trajectories of motors and to synchronize the motors with the US machine.

2.3. Data analysis 2.3.1. Motion tracking – X, Y and Total Distance The motion or kinematics of the BIC for each stretching protocol was estimated by tracking features within the US images by eye. Prior to tracking, two feature of interest (FOIs) were identified along the main axis of the muscle along the aponeurosis (dashed middle white line in Fig. 2A) at an ultrasound image width location of 5 mm and

US-Roll

X

Tendon Tapper

Y

Ultrasound Probe GE M12L

Proximal

Skin Adipose Tissue Tape

Tape MUSCLE

Image Plane

Distal

Fig. 1. Experimental setup. (A) Schematic of the whole experimental setup. There are four parts to the schematic. ① The cutout of the subject’s arm. ② The rotational motor to which is attached the brace for the lower arm. ③ The ultrasound probe holder with the probe. ④ The tendon tapper holder with the tendon tapper. (B) Close up of the schematic of the end effector of the ultrasound probe holder. The design allows the probe to be adjusted in the roll, pitch and yaw to optimize for the quality of the ultrasound image. (C) The interaction force – FUS – with the skin and muscle. (D) Schematic of the placement of the different probes relative to the biceps brachii. From left to right, the tendon tapper is set above the tendon–muscle junction. A piece of clear tape from the tendon tapper, acts as the reference for the ultrasound probe.

35 mm. In order to qualify, the FOI had to be present in both protocols and had to remain trackable for all movie frames (f = 1,2, … , m). Given the FOIs, the US movies were analyzed by hand by two different raters using a custom script. Each rater was given the location of the FOI only for the initial frame. The first rater reanalyzed the US movies at a later date to test within-rater repeatability. Subsequent to tracking, the raw pixel vectors [Xf,Yf] of the FOI (Fig. 2A) were offset from their initial positions and converted into metric units. Given the protocol, the [Xf,Yf] pairs were synchronized

Please cite this article as: Chardon, M.K., et al., Estimation of musculotendon kinematics under controlled tendon indentation. Journal of Biomechanics (2015), http://dx.doi.org/10.1016/j.jbiomech.2015.07.024i

M.K. Chardon et al. / Journal of Biomechanics ∎ (∎∎∎∎) ∎∎∎–∎∎∎

3

Subject 6 - Indentation Protocol Subject 6 Data Analysis 0

Subject 6 FOI @35 mm

Adipose Layer FOI @5 mm

Aponeurosis

XDistance (mm)

YDistance (mm)

Biceps Brachii

10

FOI @35 mm Biceps Brachii Brachialis

8 6 4 2 0

30 0

5

35

50

Proximal/Shoulder XDirection(mm)

0

Distal/ Elbow

5

15

20

Subject 6 FOI @35 mm

Subject 6 FOI @35mm 10

10

TotalDistance(mm)

YDistance (mm)

10

Indentation Position (mm)

8 6 4 2 0

8 6 4 2 0

0

5

10

15

20

0

IndentationPosition (mm)

5

10

15

20

IndentationPosition (mm)

trial 1

trial 3

trial 5

trial 2

trial 4

average

Fig. 2. Example of tracking features of interest (FOI) using ultrasound movies for the indentation protocol. (A) Initial ultrasound image prior to being indented. The image is 50 mm wide and 30 mm deep with the depth starting at the top (i.e. skin-US probe layer). The biceps brachii is sectioned by the upper and lower dotted white lines. The adipose layer is above the upper dotted white line and the brachialis is below the dotted white line. The center dotted white line follows the aponeurosis of the biceps brachii. Along the aponeurosis are the FOI @5 mm and the FOI @35 mm shown by red dots and referenced to the image width by vertical dotted lines. Superimposed on the FOIs, in color, are the five different tracking trajectories during the 20 mm indentation of the distal tendon from skin. (B, C) Displacement/Indentation Position plots of the Y and X pixel as the distal tendon is being indented. (D) Distance/Indentation Position plots of the FOI as the distal tendon is being indented. (For interpretation of the references to color in this figure legend, the reader is referred to the web version of this article.)

with the rotation angle or the indentation position giving two (f  2) vectors [Pf,Xf] and [Pf,Yf] where P is either rotation angle or the indentation position (ex: vectors plotted against each other (Fig. 2B and C)). Finally, the Total Distance (TD) vector [Pf,TDf] traveled by the FOI was calculated with the following cumulative sum equation: f

TDf =



(xi − xi − 1)2 + yi − yi − 1

(

i=2

2

)

⎧ ⎪ TD1 = 0 with ⎨ ⎪ ⎩ (f = 2, …, m)

(1)

where x i and yi are the sequential pixels in the X and Y direction (Fig. 2D). 2.3.2. Rotation–Indentation Map The Rotation–Indentation Map relates joint angle to tendon indentation position. The map was calculated by finding the matching distances traveled by the FOI for each protocol and subsequently matching their respective rotation angle and indentation position (Fig. 3C). 2.3.3. Regional strain Regional strain provides an estimate of the strain registered along the main axis of the imaged BIC for each stretch protocol. It is estimated using the following equation:

ϵ regional = TDmax @35

max TDmax @35 − TD@5 0 0 − L @5 L @35

.

(2) TDmax @5

is the maximum TD traveled by the FOI@40 mm, is 0 the maximum TD traveled by the FOI@5 mm, L @35 is the initial X

0 position of the FOI@35 mm and L @5 is the initial X position of the FOI@5 mm.

2.4. Statistical analysis 2.4.1. Models For each data set (5-trials), we fit three models: a linear curve ( f (x ) = p1x + p2), an exponential ( f (x ) = p1e p2x ), and a piecewise continuous function as described by Quapp and Weiss (1998):

⎧ a e b1x + c , 1 f (x) = ⎨ 1 ⎩ a2x + c2, ⎪



x ≤ x1 x > x1

such that

⎧ a e b1x1 + c = a x + c 1 2 1 2 ⎪ 1 ⎪ a1b1e b1x1 = a2 ⎨ ⎪ b1 > 0 ⎪ f (0) = a1 + c1 ⎩ (3)

where a1, b1, c1, a2 and c2 are parameters to be optimized and x1 is the connection point between the two curves. For each data set, we retained the model with the lowest Akaike information criteria (AIC) (Kullback and Leibler, 1951). The confidence interval of each of the piecewise parameters was estimated by a 1E4 iteration bootstrap of the fit using the residuals of the fit with largest R2 in a 500 random initial conditions search (Table 1). 2.4.2. Statistical tests To test the significance between parameters we either used a paired t-test within 5% or determined if their distribution spanned

Please cite this article as: Chardon, M.K., et al., Estimation of musculotendon kinematics under controlled tendon indentation. Journal of Biomechanics (2015), http://dx.doi.org/10.1016/j.jbiomech.2015.07.024i

M.K. Chardon et al. / Journal of Biomechanics ∎ (∎∎∎∎) ∎∎∎–∎∎∎

4

Subject 5 Rotation Protocol

Indetation Protocol

10 5

X -Rotation Angle (°)

XDistance (mm)

15 10 5 0

0

5

10

15

0

20

Indentation Position (mm)

20

30 20 10 0

30

0

Rotation Angle (°)

5

10

15

20

X - Indentation Position (mm)

20 YDistance (mm)

20 YDistance (mm)

10

15 10 5

15 Raw Data

10

Average Data 5 0

0 0

5

10

15

0

20

Indentation Position (mm)

10

20

30

Rotation Angle (°)

Total Distance (mm)

20 15 10 5

20 15 10 5 0

0 0

5

10

15

Indentation Position (mm)

20

0

10

20

Rotation Angle (°)

30

Total Distance - Rotation Angle (°)

XDistance (mm)

15

0

Total Distance (mm)

Rotation-Indentation Map

20

20

30 20 10 0 0

5

10

15

20

Total Distance - Indentation Position (mm)

Fig. 3. Example of the average results obtained from tracking the feature of interest (FOI) for the indentation of the distal tendon of the biceps (A), the rotation of the elbow (B) and the Rotation–Indentation Map (C) for a single subject. These results are the average of the five measured cycles – in/out for indentation or extend/flex for rotation. (A, B – top) The FOI’s distance traveled in the x direction relative to the indentation position and the rotation angle. (A, B – middle) The FOI’s distance traveled in the y direction relative to the indentation position and the rotation angle. (A, B – bottom) The FOI’s Total Distance traveled in the x and y direction relative to the indentation position and the rotation angle. (C – top and bottom) The Rotation–Indentation Map in the x direction and for the Total Distance. This map is created by combining the data displayed in A and B – top and bottom (see Section 2.3.2).

0 within 95%, Bonferroni corrected for multiple comparison (Motulsky and Christopoulos, 2004). 2.4.3. Rater consistency and reliability Rater performance was assessed using the intraclass correlation coefficient (ICC) (McGraw 1996). The in-between-rater ICC as well as the within-rater ICC was very high, with an average of 0.94 (70.03) and 0.97( 70.01) respectively. Detailed rater analysis results can be found in Table 2.

 the “Lowest AIC” describes which model best fits the displacement of the FOI and,

 the “Direction Ratio” is the percentage of the displacement that is in the X direction. The definitions, statistics and estimates of these values are described in Table 1 and Fig. 4. 3.1. Rotation protocol

We analyzed successive frames of US movies, to quantify motion of the FOI in a muscle, as the muscle is being stretched by elbow rotation, or as it is being stretched by tendon indentation at the elbow. To evaluate and compare each stretch condition we extracted the following parameters from the US-images:

For the rotation protocol, the FOI of all the subjects moved measurably in the X (longitudinal) direction. Conversely, in 4/6 subjects, the FOI did not move more than 0.3 mm in the Y direction and 0.7 mm for the remaining 2. These results are reflected in the direction ratios, in which the X direction is responsible for 96% of the TD. From here, we will only report on the TD for the model fits as X data mirrors the TD. The model that best fit the rotation data, with the lowest AIC score, is a line for all the subjects tested. The individual slopes are significantly different from each other, but lie within the same order of magnitude averaging 0.40(70.11)°/mm.

 the “Maximum Distance” is the maximum distance traveled by

3.2. Indentation protocol

3. Results

 

the FOI, the “Slope” is the rate of rise of the linear portion of the displacement of the FOI, the “Transition Point” is the indentation location at which the displacements transitions to a linear behavior,

For the indentation protocol, the FOI of all the subjects moved significantly in the X direction. In contrast to the rotation protocol, the FOI of 5/6 subjects moved more than 1.5 mm in the Y direction, and reached 2 mm for one subject. The direction ratios reflect these

Please cite this article as: Chardon, M.K., et al., Estimation of musculotendon kinematics under controlled tendon indentation. Journal of Biomechanics (2015), http://dx.doi.org/10.1016/j.jbiomech.2015.07.024i

M.K. Chardon et al. / Journal of Biomechanics ∎ (∎∎∎∎) ∎∎∎–∎∎∎

5

Table 1 Pooled results along the X, Y and Total Distance directions for the Rotation and Indentation protocol, as well as the rotation to indentation map.a

results in that 92% of the TD is due to the displacement in the X direction. The indentation protocol is best fit, with the lowest AIC score, by a piecewise continuous model for all the subjects tested. Focusing on the linear portion of the model, we found that the transition points between the non-linear and linear portion of the fit were not statistically different from each other for 4/6 subjects and lay, on average, at 10.95( 71.42) mm. The individual slopes statistics suggests two different groups; however they are all within the same order of magnitude 0.57( 70.14) mm/mm.

3.3. Rotation–Indentation Map We established a Rotation–Indentation Map for all the subjects tested. The model that best fits the map, with the lowest AIC score, was piecewise continuous. The transition points between the nonlinear and linear portion of the fit were not statistically different from each other for 4/6 subjects and were on average 11.41(70.93) mm. The slopes of the linear portion of the fit were found to group similarly to indentation and are of the same order of magnitude. Our main result is that there exists a linear relationship between joint rotation and tendon indention with a 1.34(70.23)°/mm ratio.

Please cite this article as: Chardon, M.K., et al., Estimation of musculotendon kinematics under controlled tendon indentation. Journal of Biomechanics (2015), http://dx.doi.org/10.1016/j.jbiomech.2015.07.024i

M.K. Chardon et al. / Journal of Biomechanics ∎ (∎∎∎∎) ∎∎∎–∎∎∎

6

4. Discussion

Furthermore, this linear relationship applies over 50% of the indentation range, and is equivalent to a 14.94(72.16)° elbow rotation for a 20 mm indentation.

The goal of this study was to determine whether muscle length changes induced by tendon indentation were broadly comparable to those induced by elbow joint rotation. Our rationale was threefold:

3.4. Regional strain The regional strain (see Eq. (2)) provides an estimate of the strain registered along the main axis of the BIC for each stretch protocol. As illustrated in the bar plots in Fig. 5B, we find that along its main axis the average BIC strains 0.05( 70.014) under rotation and 0.051( 70.014) under indentation. These strains show statistically insignificant differences.

1. tendon indentation is commonly used clinically as part of the neurological exam,

Distance Difference (mm)

Total Distance Difference b/w FOI @35 mm & FOI @5 mm

Table 2 Intraclass Correlation Coefficient (ICC). The ICC chosen is based on the analysis of variance using a two-way mixed effect model with row and column interaction. Rater vs. original

Protocol

ICC method

ICC

Rating

Subj 1

Rater 1 Redo

Indentation Rotation Indentation Rotation Indentation Rotation Indentation Rotation Indentation Rotation Indentation Rotation Indentation Rotation Indentation Rotation Indentation Rotation Indentation Rotation Indentation Rotation Indentation Rotation

A-k A-k A-k A-k A-k A-k A-k A-k A-k A-k A-k A-k A-k A-k A-k A-k A-k A-k A-k A-k A-k A-k A-k A-k

0.94 0.98 0.92 0.97 0.96 0.99 0.94 0.91 0.95 0.97 0.95 0.96 0.95 0.96 0.93 0.89 0.98 0.96 0.99 0.91 0.96 0.98 0.95 0.95

Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent Excellent

Rater 2 Subj 2

Rater 1 Redo Rater 2

Subj 3

Rater 1 Redo Rater 2

Subj 4

Rater 1 Redo Rater 2

Subj 5

Rater 1 Redo Rater 2

Subj 6

Rater 1 Redo Rater 2

ICC value 0.0 r ICC o0.4 0.4 r ICCo 0.6 0.6 r ICC o0.75 0.75 r ICC o1

Rating Poor Fair Good Excellent

0

4 2 0 5

10

15

20

Rotation-IndentationMap

10 5 0

0

5

10

15

20

25

30

Rotation Angle (°) subj 2

subj 3

Indentation

Fig. 5. Bar plots of the maximum distance difference and regional strain as calculated from the FOI @ 35 mm and the FOI @5 mm. The solid black line above the bars represent the statistical link between the bars and ns stands for: not significant. (A) The Maximum Distance difference between the FOI @35 mm and the FOI @5 mm for both the rotation and Indentation protocol. (B) The same information as (A) however the information has been normalized by the initial length between the two FOIs of 30 mm.

15

Indentation Position (mm) subj 1

Rotation

TotalDistance- RotationAngle (°)

TotalDistance (mm)

6

Indentation

Regional Strain ns

Rotation Protocol

8

0

Rotation

0.05

20

10 TotalDistance (mm)

1.5

0.1

ICC method A-k is defined as: “the degree of absolute agreement for measurements that are based on k independent measurements made under the fixed levels of the column factor” (McGraw and Wong, 1996).

Indentation Protocol

95%

0

Regional Strain

Subject

Max Distance Difference ns

3

subj 4

subj 5

30 25 20 15 10 5 0 0

5

10

15

20

Total Distance -Indentation Position (mm) subj 6

transition point & std

Fig. 4. Results for all subjects. (A) The piecewise continuous fits for the Total Distance traveled for each subject under the Indentation protocol. (B) The linear fits for the Total Distance traveled for each subject under the rotation protocol. (C) The rotation–indentation piecewise continuous maps for the Total Distance traveled for each subject.

Please cite this article as: Chardon, M.K., et al., Estimation of musculotendon kinematics under controlled tendon indentation. Journal of Biomechanics (2015), http://dx.doi.org/10.1016/j.jbiomech.2015.07.024i

M.K. Chardon et al. / Journal of Biomechanics ∎ (∎∎∎∎) ∎∎∎–∎∎∎

Using B-mode US movies, we estimated local muscle kinematics for each stretch condition by tracking a FOI in that muscle. We produced FOI distance results and used them to compare each protocol.

15 Total Distance (mm)

2. better description could improve the study of the musculotendon unit, and 3. indentation could substitute for joint rotation in motion sensitive imaging.

7

Adipose Zone

Exp Zone

Linear Zone

I

II

III

10

5

0 0

4.1. Physiological meaning for the X and Y distance

5

10

15

20

Indentation Position (mm)

The distance values in the X and Y direction do not have physiological meaning in themselves, as they are points extracted from an image that has no fixed relation to the underlying anatomy of the BIC. To assign meaning to these values we looked first at the distances traveled in the X and Y direction for the physiologically normal muscle stretch (or the rotation protocol). Our results show that the morphology of the distance traveled by the FOI in both the X and the Y direction is best fit by a two parameter linear regression. In the X direction the slope relating angular rotation of the BIC joint to the distance traveled is 0.37 (7 0.09) mm/°. In the Y direction however, the slope is on average, 0.02( 70.04) mm/° and is not significantly different from zero (p o0.05). This suggests that in this experimental setup, the data most representative of normal physiological stretching are reflected by pixel motion in the X direction. 4.2. Evaluation of the rotation protocol We compared the results obtained for the rotation protocol with data in the literature that most closely resembled our experimental setup. These data came from Murray et al. (1995) who reported the displacement of the BIC, at the tip of the distal tendon, in human cadavers relative to elbow rotation. We also used OpenSim-3.0, implementing the Stanford VA upper limb model (Holzbaur et al., 2005). For an equivalent elbow extension (120–150°), the BIC is stretched 16.02( 70.3) mm for Murray et al. (1995) and 15.72 mm for OpenSim compared to our average 10.17( 71.10) mm in the X direction and 10.60( 7 1.09) mm for the TD. This  30% difference is multifaceted in origin. First, though previous data was collected using fresh cadaveric BIC, the muscle was detached from its surrounding tissue thus allowing for greater motion. Second, since the US probe is fixed relative to the muscle, its field of view behaves just like a flow field. Therefore being 1/3 distance of the total muscle away from the tip of the distal tendon, the probe’s field captured roughly 2/3 of the stretching effects assuming an ideal linear muscle. The proportion of each effect on the results is not known however both could explain the  30% difference. The morphology of the Murray et al. (1995) and OpenSim data matches ours. The model that best fits both data sets, with the lowest AIC score, is a linear curve (R2 Z 99%) and both data sets have a 0.97 correlation coefficient with the X and TD data. 4.3. Evaluation of the indentation protocol In comparison to the rotation protocol, the displacement– indentation relationship of the indentation protocol is nonlinear and has three distinctive parts. The first is a proposed “adiposezone” in which the displacement is minimal. The second is an “exponential-zone” in which the displacement quickly increases. And the third is a “linear-zone” in which the displacement grows linearly (Fig. 6). We believe that these indentation zones are related to the soft tissue configuration underneath the indenter, as

Skin Adipose Tissue

Tendon Tapper

MUSCLE X Y Skin Adipose Tissue

Tendon Tapper

MUSCLE

Proximal

Distal

Fig. 6. Physiology of the indentation protocol. (A) The Total Distance traveled by the FOI under the indentation protocol overlaid atop the three possible physiological zones. (B) Schematic of the indentation protocol. The initial condition (top) shows the indenter at the skin above the tendon–muscular junction. The full indentation condition (bottom) shows the deformation of the layers under the indenter.

identified from our US-images as two layers: the skin-adipose layer and the tendon–muscle layer. The “adipose-zone” can be explained by the mechanics of the combined skin-adipose layer. From a biomechanics point of view, the indenter compresses the skin and adipose layer in the Y direction as if under a uniaxial unconfined compression test at low strain rates (ε~̇ 0.25 s−1). Under such conditions, the nominal stress–strain relationship of adipose tissue has been shown, for strains ε r10%, to behave linearly, to have a bulk modulus 1.15E3 Pa and to have 1E3– 2E3 Pa stress at 10% strain (Comley and Fleck, 2009; Miller-Young et al., 2002). Given these properties and the surface area of our indenter, 25π mm2, the first 10% of the indentation will generate a  0.15 N force which is too small to displace the tendon–muscle layer given its combined 8.8E6 Pa bulk modulus (Blemker et al., 2005; Weiss et al., 2002). The “exponential-zone” can be explained by two phenomena. First, as the indenter continues beyond the 10% strain, the stresses on the adipose layer increase exponentially until they become large enough to displace the tendon–muscle layer (Comley and Fleck, 2009). Second, as the force increases, the combined strain of the tendon–muscle layer will increase exponentially as the collagen fibers of the tendon, together with fibers and muscle connective tissue begin to straighten (Quapp and Weiss, 1998; Zajac, 1988). In the “linear-zone”, the tendon and muscle fibers have reached a length where their combined strains behave linearly relative to stress. Work on whole muscle mechanics, performed primarily in in-vivo animal preparations, has shown a similar trends (Joyce et al., 1969; Matthews, 1959). Even though direct evidence of the effect of indentation of the skin–adipose–tendon–muscle complex is not available, we believe that the morphology of the displacement–indentation relationship of the indentation protocol is consistent with known passive material properties.

Please cite this article as: Chardon, M.K., et al., Estimation of musculotendon kinematics under controlled tendon indentation. Journal of Biomechanics (2015), http://dx.doi.org/10.1016/j.jbiomech.2015.07.024i

8

M.K. Chardon et al. / Journal of Biomechanics ∎ (∎∎∎∎) ∎∎∎–∎∎∎

4.4. Is the indentation stretch physiologically relevant? Our results suggest three major finding with respect to the physiology of the tendon stretch. First, large scale tendon indentation of the BIC substantially stretches the muscle, because the TD traveled by the FOI is on average only 32% smaller than the TD traveled by the FOI during a rotational stretch. This result is partially confounded by the “adipose zone” in which there is an indentation region where the displacement of the FOI is minimal. However, using the linear portion of the piecewise curve that best fits the indentation data (Table 1), we calculated the theoretical maximum TD if the “adipose-zone” did not exist and found that the 32% difference in TD traveled disappears between the two protocols. This means basically that the indentation actions can be ignored until the tendon–muscle complex is loaded, and begins to move with increasing indentation. The second major finding is that 92% of the TD traveled during the indentation protocol is in the longitudinal or X direction. The X direction is most representative of normal physiological displacement, because we recorded no significant displacements in the Y direction during the rotation protocol. Furthermore, because the FOI motion had large displacements values in the X direction in both protocols, we can conclude that the physiology of a tendon stretch is broadly analogous to normal physiological stretch. Third, on average our estimate of the regional strain along the main axis of the muscle for both stretching protocols shows insignificant statistical differences, suggesting that the tendon indentation and joint rotation will strain the muscle similarly along the main axis of the muscle. Considering that muscle receptors respond to local strain this finding indicates that an equivalent amount of proprioceptive feedback will presumably reach the spinal cord, regardless of stretching protocol. We do expect however, that the strain rate will be different for each protocol, due to the non-linear kinematics of tendon indentation. While the static information of the proprioceptive information will presumably be equivalent, we expect the dynamic information to differ in its delivery rate. Therefore, to truly match the two protocols, rotational and indentation speed must be taken into account. On a regional analysis however, the non-linear behavior of the indentation kinematics disappears, further supporting the premise that each protocol stretches the muscle equivalently. The results presented strongly indicate that a 20 mm indentation of the region above the distal tendon of the BIC is broadly equivalent to a 15° elbow rotation. By removing the “adiposezone”, the relationship becomes linear with a 1/2 indentation– rotation ratio. Furthermore, each stretching protocol strains the main axis of the muscle equivalently. 4.5. Benefits and limitations of this stretching technique Even though further validation is needed, tendon indentation has multiple benefits for the study muscle–tendon mechanics. It allows for the exploration of a muscle’s properties without needing large-scale joint rotation which is particularly useful in pathological states. It allows for the study of muscles associated with joints having range of motion too large for certain imaging techniques. Finally tendon indentation allows the exploration of the mechanics of muscles spanning a joint independently of joint motion, or in concert. A limitation of this technique is that it is best-suited to muscles with an accessible tendon allowing for indentation (i.e. away from bone). Joints can be adjusted to maximize the indentation distance; however this technique would thus far exclude deep muscles. Finally, although our approach enables direct comparison between two stretching techniques, (rotation and indentation) it does not encompass musculotendon kinematics during a tendon tap. The high

velocity nature of a tap should introduce highly nonlinear features into the system in part due to muscle stiction, tendon and extracellular matrix properties. To capture such events warrants high speed medical imaging. This topic warrants further study. 4.6. Methodological considerations 4.6.1. Choice of feature of interest In order to be consistent across subjects, we chose the FOIs to be in similar regions of the muscle, as well as being visible in both stretch protocols. The FOIs were chosen to be along the axis of the aponeurosis (Fig. 2A) and we chose the @5 mm location to be as proximal as possible and the @35 mm location in order to emulate the Murray et al. (1995) experiments which measured BIC displacement from the tip of its distal tendon. 4.6.2. Effect of US probe placement on measurements A reported source of measurement error in B-mode US imaging is US probe placement and handling (Bénard et al., 2009; Kristjansson, 2004; Kwah et al., 2013). To minimize error, we reduced the contact of the probe on the muscle to its sensing surface and leveraged gravity to control the “probe–muscle” interaction force by letting the probe freely rotate around US-pitch (Fig. 1C). We further aligned the image plane of the probe such that it would return maximum reflectivity. Finally, we constrained the subject in space and co-aligned the rotation axis of the elbow and the motor to minimize motion from the subject.

5. Conclusion Tendon indentation is the basis of many neurological tests, such as the deep tendon reflex, however its effect on muscle kinematics and subsequently on spindle receptor mechanical transduction has been largely unexplored. Understanding the effects of indentation on muscle kinematics would further our understanding of the neural control of movement. These data will also help design novel tendon tapping apparatus to refine neurological tests, gather of global musculotendon unit mechanics and perhaps serve as a surrogate to joint rotation.

Conflict of interest The authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest (such as honoraria; educational grants; participation in speakers' bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements), or non-financial interest (such as personal or professional relationships, affiliations, knowledge or beliefs) in the subject matter or materials discussed in this manuscript.

Acknowledgments We extend our gratitude to Colin Feng and to Matt Kindig for their help with experimental design; to Mehdi Mirbagheri-PhD and to Li-Qun Zhang-PhD for giving access to equipment and facilities. This work was supported by an NIH-Center-Grant-R24HD50821-07. References Bénard, M.R., Becher, J.G., Harlaar, J., Huijing, P.A., Jaspers, R.T., 2009. Anatomical information is needed in ultrasound imaging of muscle to avoid potentially

Please cite this article as: Chardon, M.K., et al., Estimation of musculotendon kinematics under controlled tendon indentation. Journal of Biomechanics (2015), http://dx.doi.org/10.1016/j.jbiomech.2015.07.024i

M.K. Chardon et al. / Journal of Biomechanics ∎ (∎∎∎∎) ∎∎∎–∎∎∎ substantial errors in measurement of muscle geometry. Muscle Nerve 39, 652–665. Blemker, S.S., Asakawa, D.S., Gold, G.E., Delp, S.L., 2007. Image-based musculoskeletal modeling: applications, advances, and future opportunities. J. Magn. Reson. Imaging 25, 441–451. Blemker, S.S., Pinsky, P.M., Delp, S.L., 2005. A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii. J. Biomech. 38, 657–665. Chardon, M.K., Rymer, W.Z., Suresh, N.L., 2014. Quantifying the deep tendon reflex using varying tendon indentation depths: applications to spasticity. IEEE Trans. Neural Syst. Rehabil. Eng. 22, 280–289. Comley, K., Fleck, N.A., 2009. The high strain rate response of adipose tissue. In: Proceedings of the IUTAM Symposium on Mechanical Properties of Cellular Materials, pp. 27–33. Holzbaur, K.R.S., Murray, W.M., Delp, S.L., 2005. A model of the upper extremity for simulating musculoskeletal surgery and analyzing neuromuscular control. Ann. Biomed. Eng. 33, 829–840. Iivarinen, J.T., Korhonen, R.K., Julkunen, P., Jurvelin, J.S., 2011. Experimental and computational analysis of soft tissue stiffness in forearm using a manual indentation device. Med. Eng. Phys. 33, 1245–1253. Joyce, G.C., Rack, P.M.H., Westbury, D.R., 1969. The mechanical properties of cat soleus muscle during controlled lengthening and shortening movements. J. Physiol. 204, 461–474. Kristjansson, E., 2004. Reliability of ultrasonography for the cervical multifidus muscle in asymptomatic and symptomatic subjects. Man. Ther. 9, 83–88. Kullback, S., Leibler, R.A., 1951. On information and sufficiency. Ann. Math. Stat. 22, 79–86. Kwah, L.K., Pinto, R.Z., Diong, J., Herbert, R.D., 2013. Reliability and validity of ultrasound measurements of muscle fascicle length and pennation in humans: a systematic review. J. Appl. Physiol. 114, 761–769. Leonard, C.T., Stephens, J.U., Stroppel, S.L., 2001. Assessing the spastic condition of individuals with upper motoneuron involvement: validity of the myotonometer. Arch. Phys. Med. Rehabil. 82, 1416–1420. Matthews, P.B.C., 1959. The dependence of tension upon extension in the stretch reflex of the soleus muscle of the decerebrate cat. J. Physiol. 147, 521–546. McGraw, K.O., Wong, S.P., 1996. Forming inferences about some intraclass correlations coefficients. Psychol. Methods 1, 390.

9

Miller-Young, J.E., Duncan, N. a, Baroud, G., 2002. Material properties of the human calcaneal fat pad in compression: experiment and theory. J. Biomech. 35, 1523–1531. Moerman, K.M., Sprengers, A.M.J., Simms, C.K., Lamerichs, R.M., Stoker, J., Nederveen, A.J., 2011. Validation of SPAMM tagged MRI based measurement of 3D soft tissue deformation. Med. Phys. 38, 1248. Motulsky, H., Christopoulos, A., 2004. Fitting Models to Biological Data Using Linear and Nonlinear Regression: A Practical Guide to Curve Fitting. Oxford University Press, New York, NY. Murray, W.M., Delp, S.L., Buchanan, T.S., 1995. Variation of muscle moment arms with elbow and forearm position. J. Biomech. 28, 513–525. Palevski, A., Glaich, I., Portnoy, S., Linder-Ganz, E., Gefen, A., 2006. Stress relaxation of porcine gluteus muscle subjected to sudden transverse deformation as related to pressure sore modeling. J. Biomech. Eng. 128, 782–787. Quapp, K.M., Weiss, J.A., 1998. Material characterization of human medial collateralligament. J. Biomech. Eng. 120, 757–763. Uchiyama, T., Kimura, R., Murayama, M., Kimural, R., 2000. Elastic-and viscous-like property of the upper arm estimated by the pushing method. In: Proceedings of the 22nd Annual International Conference of the IEEE, Engineering in Medicine and Biology Society, p. 583. Van Loocke, M., Lyons, C.G., Simms, C.K., 2006. A validated model of passive muscle in compression. J. Biomech. 39, 2999–3009. Van Loocke, M., Lyons, C.G., Simms, C.K., 2008. Viscoelastic properties of passive skeletal muscle in compression: stress-relaxation behaviour and constitutive modelling. J. Biomech. 41, 1555–1566. Voerman, G., Gregorič, M., Hermens, H., 2005. Neurophysiological methods for the assessment of spasticity: the Hoffman reflex, the tendon reflex, and the stretch reflex. Disabil. Rehabil. 27, 33–68. Weiss, J.A., Gardiner, J.C., Bonifasi-Lista, C., 2002. Ligament material behavior is nonlinear, viscoelastic and rate-independent under shear loading. J. Biomech. 35, 943–950. Zajac, F.E.E., 1988. Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control. Crit. Rev. Biomed. Eng. 17, 359. Zheng, Y.P., Mak, A.F., 1996. An ultrasound indentation system for biomechanical properties assessment of soft tissues in-vivo. IEEE Trans. Biomed. Eng. 43, 912–918.

Please cite this article as: Chardon, M.K., et al., Estimation of musculotendon kinematics under controlled tendon indentation. Journal of Biomechanics (2015), http://dx.doi.org/10.1016/j.jbiomech.2015.07.024i