RR hysteresis lag

RR hysteresis lag

Journal of Electrocardiology Vol. 36 Supplement 2003 Estimation of the QT/RR Hysteresis Lag Esther Pueyo, BSc,*† Peter Smetana, MD,* Pablo Laguna, P...

81KB Sizes 5 Downloads 47 Views

Journal of Electrocardiology Vol. 36 Supplement 2003

Estimation of the QT/RR Hysteresis Lag

Esther Pueyo, BSc,*† Peter Smetana, MD,* Pablo Laguna, PhD,† and Marek Malik, PhD, MD*

Abstract: The process of QT interval adaptation to heart rate (HR) changes was evaluated by considering weighted averages of RR intervals to characterize the influence of previous cardiac cycles. An optimum adaptation pattern was individually derived for each patient and several descriptors of the QT/RR hysteresis were subsequently calculated. The values of these parameters showed that the QT adaptation to HR changes is highly individual and, consequently, any generalized approach may lead to inappropriate conclusions. Key words: QT/RR Hysteresis, QT lag, [QT/RR] relationship, repolarization.

preceding RR interval but to a history of previous RR interval values. A searching was performed for the window that led to the optimum [QT,RR] fit, where RR is the weighted average of preceding RR measurements. From such an individually obtained QT/RR adaptation pattern, a numerical quantification of the hysteresis lag was obtained together with a descriptor of the QT/RR hysteresis dynamicity that quantifies the velocity and profile of the QT interval adjustment.

It is known that the changes in the QT interval lag behind the changes in RR interval (QT/RR hysteresis). However, at present, only simple approaches have been implemented in some Holter systems assuming a constant duration of the QT/RR hysteresis lag in all patients. In addition, not only the duration but also the way in which QT adapts may substantially differ between subjects. Among others, the omission of the individual adaptation characteristics might result in significant errors in the estimation of heart rate corrected QT interval (QTc). We therefore investigated the QT/RR hysteresis by analyzing the dynamics in which the QT intervals adapt to the changes in the RR intervals. For this purpose, we considered RR averaging windows preceding each measured QT interval, that is to relate each QT interval not only to the immediately

Materials and Methods Study Population The study investigated a population of 866 patients taken from the EMIAT trial database (1). All subjects were survivors of acute myocardial infarction, aged ⱕ75 years, with left-ventricular ejection fraction (LVEF) ⱕ40%. Recordings available for the study were 24-hour 3-lead Holter ECGs obtained one month after treatment randomization; 462 were obtained on amiodarone and 404 on placebo.

From the *St. George’s Hospital Medical School, London, United Kingdom; and †Communications Technology Group, Arago´n Institute for Engineering Research (I3A), University of Zaragoza, Spain. Reprint requests: Marek Malik, PhD, MD, Department of Cardiological Sciences, St. George’s Hospital Medical School, Cranmer Terrace, London SW17 ORE, England e-mail: [email protected] © 2003 Elsevier Inc. All rights reserved. 0022-0736/03/03/360S-0053$30.00/0 doi:10.1016/j.jelectrocard.2003.09.056

187

188 Journal of Electrocardiology Vol. 36 Supplement 2003 Data Analysis RR and QT intervals were automatically measured on a beat-to-beat basis using a commercial Holter system (Pathfinder, Reynolds Medical Inc, Hertford, UK). In each lead, only beats with accepted QT and RR intervals were considered and, in each recording, the lead with more accepted measurements was selected. Detection of incidences in the RR signal (false positives, false negatives and ectopic beats) was carried out according to the methodology described in (2). Beats for which a preceding 300-second window included no valid measurements were rejected. QT Adaptation Pattern QT interval dependence on preceding RR intervals was characterized by an RR interval averaging window that was optimized to lead to the lowest regression residual of the [QT,RR] data, where RR is the corresponding weighted average of RR interval measurements in the window. In order to determine such an optimum weight distribution individually, a global optimization algorithm based on the Direct method (3,4) was implemented, in which the objective function to be minimized was defined at each weight vector w ⫽ (w1, . . ., wN) as the global residual from fitting any of 10 a-priori selected regression models (5) to the [QTi,RRi] data, with RRi computed for each ith beat as

冘 i

RR i ⫽

j⫽i⫺N⫹1

w j⫺i⫹N RR j

where N is the number of beats contained in preceding 300-second window within the 24-hour recording, and w ⫽ (w1, . . . , wN) are all positive and normalized such that w1 ⫹ . . . ⫹ wN ⫽ 1. As a result, 10 different combinations of weights wi and regression parameters were determined for each recording, each combination characterizing the optimum RR influence associated with one regression model. A unique pattern of averaging window was identified by selecting the model leading to the minimum residual when the RR intervals were computed from the original RR interval measurements with the regression model-specific optimum weights. QT/RR Descriptors The developed analysis of QT adaptation to RR changes provided an individual profile of the QT/RR

Fig. 1. Determination of the effective window length for RR averaging, considering a threshold ␩ covering 90% of the sum of weights. The weight distribution wj is plotted as a solid line and its cumulative sum H(j) as a dashed line.

hysteresis, from which two parameters characterizing the adaptation process were calculated: ● Lag, describing the effective length of RR influ-

ence. It was computed from the optimum weight distribution wj by considering a cumulative sum

冘w , j

H共j兲 ⫽

k

j ⫽ 1,. . .,N

k⫽1

reaching a threshold ␩ ⫽ 0.1 defined to cover 90% of the adaptation (Fig. 1). The number of beats required to achieve the limit imposed by ␩ were counted and Lag was defined as the corresponding time in seconds, using the mean RR for conversion from beats to seconds. • ␭, inverse beat-velocity of the QT adaptation. It was determined from fitting the cumulative sum of weights H(j) with an exponential model: H(j) ⫽ eAj⫹B (Fig. 2). Correlation values above 0.91 confirmed the suitability of the fit. The ␭ parameter was defined as the time constant of the model: ␭ ⫽ 1/A. Heart Rate Correction Each of the 10 regression models was converted into a heart rate correction formula by projecting the QT interval onto a standard level of RR ⫽ 1 second. For each patient, the individualized QT correction formula was selected corresponding to the optimally determined regression model. Such a formula was optimized according to the criterion of null Pearson correlation coefficient between QTc and RR.

Estimation of the QT/RR Hysteresis Lag •

Pueyo et al. 189

Fig. 2. In (A) and (C), two different examples of optimum weight distributions corresponding to two patients in the study are represented. Their respective cumulative sums of weights are plotted in (B) and (D), which were fitted with exponential models in order to extract values of the adaptation rate (␭ ⫽ 46.52 and ␭ ⫽ 54.67 beats, respectively).

Results Evaluation of the QT adaptation lag revealed that, on average, 140 seconds of the preceding RR intervals have influence on the QT interval duration. Nevertheless, observation of weight distributions characterizing the adaptation profiles showed that the influence of the most distant RR intervals is small compared to the most recent ones. This proportion was differently expressed in different patients. Examining the individual values of the parameter Lag, we observed high inter-subject variability, as confirmed by the high standard deviation of the variable, which was around 35 seconds. In fact, the Lag values ranged from 3 to over 215 seconds. Furthermore, not only the delays in the heart rate adaptation of ventricular repolarization but also the characteristic adaptation profiles, that is the way in which QT reacts to RR changes, showed very high inter-subject variability. Mean value of ␭ was 47.6 ⫾ 8.1 beats. Figures 2A and 2C shows 2 examples representative of very different adaptation profiles, with ␭ ⫽ 46.52 beats characterizing a fast adaptation, and ␭ ⫽ 54.67 beats characterizing much slower adaptation. These results demonstrate the necessity of considering the individual QT/RR hysteresis patterns and the use of an individualized correction formula to correct the QT interval for the effects of heart rate.

Discussion and Conclusions In this study, the evaluation of the QT/RR hysteresis lag showed that, despite the strong dependence of QT on the preceding cardiac cycle, an individually variable history of heart rate also contributes to QT variations. The way QT is influenced by previous RR intervals and the interval necessary to describe the complete adaptation process varies significantly among patients. This fact enhances the importance of having obtained individual adaptation profiles representative of optimum weights assigned to past RR measurements, which should be taken into account within Holter systems. The assumption of the lag in the QT adaptation being constant for all subjects is clearly contradicted by the results of this study.

References 1. Julian DG, Camm AJ, Frangin G, et al: Randomised trial of effect of amiodarone on mortality in patients with left-ventricular dysfunction after recent myocardial infarction. EMIAT. The Lancet 349:667, 1997 2. Mateo J, Laguna P: Analysis of heart rate variability in

190 Journal of Electrocardiology Vol. 36 Supplement 2003 the presence of ectopic beats using the heart timing signal. IEEE Trans Biomed Eng 50:1099, 2002 3. Jones DR, Perttunen CD, Stuckman BE: Lipschitzian optimization without the Lipschitz constant. J Optimiz Theory App 79:157, 1993 4. Lewis RM, Torczon V, Trosset MW: Direct search

methods: then and now. Journal of Computational and Applied Mathematics 124:191–207, 2000 5. Pueyo E, Smetana P, Hnatkova K, et al: Time for QT adaptation to RR changes and relation to arrhythmic mortality reduction in amiodarone-treated patients. Comput Cardiol 29:565, 2002