Journal Pre-proof Flexible chemiresistive sensor of polyaniline coated filter paper prepared by spraying for fast and non-contact detection of nitroaromatic explosives Weiyu Zhang, Zhaofeng Wu, Jindou Hu, Yali Cao, Jixi Guo, Mengqiu Long, Haiming Duan, Dianzeng Jia
PII:
S0925-4005(19)31432-7
DOI:
https://doi.org/10.1016/j.snb.2019.127233
Reference:
SNB 127233
To appear in:
Sensors and Actuators: B. Chemical
Received Date:
27 July 2019
Revised Date:
23 September 2019
Accepted Date:
5 October 2019
Please cite this article as: Zhang W, Wu Z, Hu J, Cao Y, Guo J, Long M, Duan H, Jia D, Flexible chemiresistive sensor of polyaniline coated filter paper prepared by spraying for fast and non-contact detection of nitroaromatic explosives, Sensors and Actuators: B. Chemical (2019), doi: https://doi.org/10.1016/j.snb.2019.127233
This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain. © 2019 Published by Elsevier.
Article type: Research Paper Flexible chemiresistive sensor of polyaniline coated filter paper prepared by spraying for fast and non-contact detection of nitroaromatic explosives
Weiyu Zhang,a Zhaofeng Wu,a,b* Jindou Hu,b Yali Cao,b Jixi Guo,b Mengqiu Long,c Haiming Duan,a* Dianzeng Jiab*
a
School of Physics Science and Technology, Xinjiang University, Urumqi, Xinjiang
b
ro of
830046, China
Key Laboratory of Energy Materials Chemistry, Ministry of Education, Key
Laboratory of Advanced Functional Materials, Xinjiang University, Urumqi,
Institute of Super-microstructure and Ultrafast Process in Advanced Materials,
re
c
-p
Xinjiang 830046, China
School of Physics and Electronics, Central South University, Changsha 410083,
lP
China
na
E-mail:
[email protected] (Z. Wu),
[email protected] (H. Duan),
[email protected] (D.
ur
Jia)
The table of contents entry
Jo
Flexible sensor of flower-like PANI coated filter paper was prepared by spraying for the first time, achieving the highly sensitive and fast detection of nitroaromatic explosives. Response fluctuation does not exceed 7% during the bending process and the decreases of responses are less than 7.9% after 2,000 bends of 40o due to the interlaced flower-like PANI fibers. The spraying method is suitable for economical,
efficient and large-scale preparation of paper-based flexible sensors.
ro of
For ToC only
•The flexible sensor of flower-like PANI coated filter paper was prepared by spraying for the first time. o
The response time and recovery time to TNT, PA and DNT are no more than 8.1 and 1.9 s, and
re
-p
Highlights
o
lP
the theoretical detection limit for TNT and PA is 0.094 and 0.029 ppb,respectively.
Response fluctuation of flexible sensors does not exceed 7% in the bending process and the
ur
Abstract:
na
decreases of responses are less than 7.9% after 2,000 bends of 40o.
Jo
Both bending stability and high sensitivity are two important problems to be solved in developing flexible sensors. The flexible sensor based on flower-like polyaniline coated filter paper (PCFP) was developed by spraying for the first time, achieving the non-contact and fast detection of nitroaromatic explosives. Hierarchical structure, high permeability of filter paper and the interaction between amino groups of PANI and nitro groups of nitroaromatic explosives contributed to the sensitive and fast
response to 2, 4, 6-trinitrotoluene (TNT), picric acid (PA) and 2, 4-dinitrotoluene (DNT) at room temperature. The responses of PCFP to TNT, PA and DNT run up to about 237.7, 100.6 and 80.1%, respectively. The average response time and recovery time to TNT, PA and DNT are no more than 8.1 and 1.9 s, respectively. The theoretical limit of detection for TNT and PA is 0.094 and 0.029 ppb, respectively. More importantly, the special interlaced flower-like structures of polyaniline
ro of
contributed to the good flexural stability. The response fluctuation to TNT, PA and
DNT do not exceed 7% in the bending process and the decreases of responses are less than 7.9% after 2,000 bends of 40o. In addition, the spraying method is suitable for
re
-p
economical, efficient and large-scale preparation of paper-based flexible sensors.
1. Introduction
lP
Keywords: flexible sensor, polyaniline, filter paper, explosives detection, spraying
na
In recent years, explosive-based terrorism has grown enormously because explosive-based weapons are simple, easy to deploy, and can cause enormous
ur
damage [1-3]. As the war against terrorism in the Middle East draws to a close,
Jo
escaped terrorists are speeding up their return to the rest of the world, exacerbating the risk of explosive attacks. For example, in April 2019, a terrorist bombing in Sri Lanka killed more than 200 people and injured hundreds of others, shocking the whole world. The rapid and sensitive detection of explosives, such as 2, 4, 6-Trinitrotoluene (TNT), picric acid (PA) and 2, 4dinitrotoluene (DNT), have attracted substantial efforts, especially in the field
of chemiresistive explosive sensors[1, 4-7]. Because nitroaromatic explosives generally have very low vapour pressures at room temperature (RT), both high sensitivity and fast response are necessary for the non-contact detection of explosives in actual security checks, such as airports and hotels [1,3, 4-6]. Traditional sensing materials are mostly solid powders and need rigid substrates or flexible substrates to support them [8]. It is reported that most current
ro of
substrates including ceramics and plastics are nonbiodegradable, nonrecyclable and have poor biocompatibility [9,10]. For example, plastic requires 450 years to decompose. However, the lifetime of many sensors and flexible displays is
-p
on average 18 months [9,10]. As a result, electronic applications generate a
re
large amount of waste. Meanwhile, the poor permeability of these current substrates hinders the effective exposure of sensing materials to the target gas,
lP
thus limiting the improvement of gas sensing properties [11-13].
na
To overcome these drawbacks, the paper-based gas sensors have been developed and used as simple, multipurpose, flexible and disposable alternative
ur
device systems because of the easy biodegradation, high permeability and low cost. In this context, Liu et al. constructed the flexible NO2 gas sensors by spin
Jo
coating the colloidal PbS quantum dots onto Al 2O3, polyethylene terephthalate (PET) and paper, respectively. The paper-based gas sensors showed the highest gas-sensing response to 50 ppm of NO2, because of the higher porosity from porous and rough nature of paper [11]. Manohar et al. reported that chemiresistive sensor based on single walled carbon nanotubes (SWCNTs) on
cellulosics (paper and cloth) could detect aggressive oxidizing vapours such as NO2 and chlorine at 250 and 500 ppb, respectively. The sensors of CNTs on 100% acid-free paper displayed a higher sensitivity than dip-coated films on plastic substrates [14]. Swager et al. mechanically drew CNTs on different type of papers to detect NH3, showing a theoretical limit of detection (LOD) of 0.36 ppm [15]. Swager et al. also reported a rapid prototyping of chemically
ro of
functionalized CNTs on paper to produce sensor arrays, achieving the
discriminative detection of several volatile organic compounds (VOCs) [16]. Similar to CNTs, polyaniline (PANI) also was widely studied as promising
-p
candidates for flexible organic semiconductors in developing flexible
re
electronics and sensors [17, 18]. What's more, PANI has the advantage of tunable morphology, scalable preparation, easy doping and low cost over CNTs
lP
[8, 19, 20]. Recently, Rutledge et al. fabricated gas sensors using electrospun
na
PANI fibers doped with different levels of sulfonic acid [21]. The doped and undoped PANI fibers were excellent NH3 and NO2 sensors, respectively. Wan
ur
et al. successfully fabricated gas sensors using a transparent conducting film of hierarchically PANI networks on a PET substrate for the sensitive detection of
Jo
NH3 [8]. Wang et al. adopted a paper loaded with PANI to selectively and sensitively detect TNT (in solution) down to 14 ng/cm2 using the photothermal effect of PANI [22]. However, there has been no report that the flexible chemiresistive PANI-based sensor has been used to detect explosives up to now. This may be
related to the fact that the common nitroaromatic explosives are very difficult to detect due to the low vapour pressures [1, 23, 24]. Recently, spraying deposition, a low-cost and large-scale technique to rapidly coat a polymer solution on a variety of substrates to prepare polymer films with micro-nanostructures, has been developed [25-27]. The spraying method provides a fast, convenient and low-cost scheme for fabricating flexible
ro of
sensors. Considering the dual requirements of anti-explosive attacks and
environmental protection, we developed the flexible chemiresistive sensor
-p
based on polyaniline coated filter paper (PCFP) by spraying for the first time. As far as we know, this is the first report on the preparation of PCFP by
lP
chemiresistive PCFP sensor.
re
spraying and the detection of nitroaromatic explosives using a flexible
2. Materials and methods
na
2.1 Chemicals and Reagents
Aniline (99%, Alfa Aesar) was distilled before use and stored at 4 °C.
ur
Ammonium persulfate (98%) and HCl (38%) were purchased from Sinopharm Chemical Reagent Co., Ltd., Beijing, China. Qualitative filter papers (7 cm in
Jo
diameter) were purchased from Fuyang North wood pulp and Paper Co., Ltd. Picric acid (PA) and 2, 4-dinitrotoluene (DNT) purchased from national standard substance center were recrystallized and dried to produce saturated vapour at RT. The methanol solution of 2, 4, 6-Trinitrotoluene (1 mg/mL, TNT) was purchased from Sinopharm Chemical Reagent Co., Ltd., (Shanghai China),
and TNT was recrystallized to produce saturated vapour at RT. Caution: The highly explosive TNT and other nitro-explosives used in the present study should be used are highly explosive and should be handled only in small quantities [5]. 2.2 Preparation of flexible PCFP First, 5 mL of aniline and 5 mL of HCl were added to 90 mL of deionized
ro of
water and magnetically stirred for 10 min. Second, 5 g of ammonium persulfate was dissolved by stirring to 10 mL of deionized water. Third, the two solutions
-p
were cooled by ice water mixture to 0◦C and mixed evenly by the quick stirring. Fourth, the mixed solution was immediately sprayed onto the filter paper by
re
spraying equipment for 30s and after 24 h the filter paper was soaked in
lP
deionized water for about 10 min to remove unreacted residues. Finally, PCFP was dried slowly at RT and cut into strips (with size of 20×5 mm 2) as sensing
na
chips.
Jo
ur
2.3 Bending sensing tests
Fig. 1. Diagram of bending sensing tests of flexible PCFP sensor. A 500 mL of conical bottle containing solid explosive particles is sealed and heated at 40 °C for 24 h, then cooled at RT (25 ± 1 °C) for 24 h to obtain saturated explosive vapour at RT. The gas sensing performances of PCFP to the vapours of TNT, DNT and PA were tested at RT (25 ± 1 °C) by an electrochemical workstation (CIMPS-2, ZAHER ENNIUM) with a bias voltage
ro of
of 1 V. The temperature and humidity of the testing room were controlled at 25 ± 1 °C and 35% ± 2% respectively by an air conditioning system. As shown in
Fig. 1, to facilitate sensing tests, the flexible PCFP was fixed on the ruler by the
-p
metal clip and adhesive tape, so that the sensor can be stably moved into
re
different atmosphere (target gas and reference gas) by moving the ruler from the target gas to the reference gas. When the flexible PCFP was inserted into
lP
the saturated vapour of an explosive from the reference gas, the electric current
na
changed. After the electric current reached a new constant value, the PCFP was then inserted into a same size conical flask full of air to recover. The response
ur
in electric current is defined as, Response=-ΔI/Ia=(Ig-Ia)/Ia×100%, where Ia and Ig are the electric current of the sensor in air and in explosive vapour. The
Jo
response time is defined as the period in which the electric current of the sensor reaches 90% of the response value upon exposure to the explosive vapour, while the recovery time is defined as the period in which the electric current of the sensor changes to 10% of the response value after the explosive vapour is removed. The bending test of flexible PCFP was shown in Scheme S1. The
length of the PCFP is 2.00 cm and the width of the electrode clip is 0.25 cm. When the PCFP is fixed on the ruler with an electrode clip, the length of the exposed flexible sensor is 1.50 cm. When the bending angle is 0o, the flexible PCFP is laid flat on the ruler and the distance between the two clips is just 1.50 cm (Scheme S1b). When the flexible PCFP is bent, the exposed part of the flexible PCFP becomes an isosceles triangle, and the distance between the two
ro of
clips is the bottom of the isosceles t0riangle. Therefore, the distances between
clips are 0.60 cm and 0.35 cm, respectively, corresponding to the bending angle
-p
of 40o and 80o (Scheme S1c, d). 2.4 Characterization
re
Surface properties of pure filter paper and PCFP were tested by fourier
lP
transform infrared (FT-IR) spectrometer (Bruker VERTEX 70, Germany) using the attenuated total reflection mode. Meanwhile, the UV-vis absorbance spectra
na
of samples were recorded with a UV-3900H spectrometer (Hitachi, Japan). The morphology of PCFP was observed by field emission scanning electron
ur
microscopy (FE-SEM, S-4800, Hitachi, Japan). In addition, the Raman spectra
Jo
of samples were recorded by SENTERRA Compact Raman Microscope (Brooker, Germany).
3. Results and Discussion 3.1 Morphology and Surface Properties of PCFP
ro of
-p
Fig. 2. (a) SEM images of pure filter paper, (b-d) SEM images with different magnification of PCFP.
re
It can be seen from the SEM images that the pure filter paper has a rough
lP
fiber structure (Fig. 2a,b), so it has good permeability due to the porous structure (Fig. S1). Macroscopically, PANI fibers are clustered and larger pores
na
exist between island-like clusters (the dotted arrows in Fig. 2b). More careful observation shows that the combinations of micro/nano PANI fibers produce
ur
good permeability (Fig. 2c, d). One-dimensional structure of PANI and high
Jo
permeability are very conducive to the penetration of target gas molecules and the rapid transfer of charges. In addition, one can see that PANI fibers are firmly rooted on the fibers of filter paper (Fig. S2). The flower-like interlaced PANI fibers and close connection between PANI and filter paper could contribute to the good bending stability for repeated mechanical bending.
ro of -p re lP
na
Fig. 3. (a) UV-vis spectrum, inset: photographs of pure filter paper and PCFP, (b) ATR-FTIR spectrum, (c) Raman spectrum of pure filter paper and PCFP.
ur
PANI loaded on filter paper can also be proved by the change of surface properties of filter paper before and after spraying. As shown in Fig. 3a, compared
Jo
with pure filter paper, the UV-vis intensity of the PCFP in the ultraviolet-visible region increased significantly, especially in the visible region. The obvious contrast in UV-vis spectrum is consistent with the sharp contrast of the insets in Fig. 3a. In addition, the photograph of PCFP also reflects macroscopically the uniform growth of PANI on filter paper. As shown in Fig. 3b, compared with the pure filter paper, the
new peaks at about 1572 cm-1 and 1495 cm-1 appear in the FTIR spectrum of PCFP, which belong to C=C stretching-quinoid rings and C=C stretching-benzenoid rings of PANI, respectively [28]. Similarly, as shown in Fig. 3c, the Raman spectrum of the filter paper before and after spraying change significantly, which is consistent with the results reflected by UV-vis spectrum and ATR-FTIR spectrum. These results
na
lP
re
-p
3.2 Gas Sensitive Performances of Flexible PCFP
ro of
indicate that the preparation of PCFP by spraying is simple, economical and feasible.
Fig. 4. Flexible sensor based on PCFP (a) the electric currents of the sensor in air
ur
under different bending angles, Inset: image of the bent sensor, Response curves of the sensor to the saturated vapors of (b) TNT (9.1 ppb), (c) PA (0.97 ppb) and (d)
Jo
DNT (411 ppb) at RT when tested under different bending angles. The sensing performances of flexible sensors based on PCFP at different
bending degrees were shown in Fig. 4. When the bending angle reaches 90o, it is equivalent to completely folding the flexible sensor. The electrical currents of the sensor showed negligible changes at different bending angles up to 90o (Fig.
4a). The inset shows the flexible sensors based on PCFP being bent. Fig. 4b-d shows the sensing response of the sensors to the saturated vapours of TNT, PA and DNT at RT when bent at different angles. It can be seen from Fig. 4b-d that
-p
ro of
the flexible PCFP exhibits good flexural stability at different bending angles.
re
Fig. 5. (a) Sensing responses, (b) response times, (c) recovery times and standard
lP
deviation over three continuous responses of flexible PCFP, (d) sensing mechanism of TNT, PA and DNT interacted with HCl-doped PANI.
na
Statistical data in Fig. 5a further show that these changes of responses to 9.1 ppb of TNT, 0.97 ppb of PA and 411 ppb of DNT do not exceed 7% during the
ur
bending process from 0o to 80o, displaying the good bending stability. The
Jo
responses to TNT, PA and DNT run up to about 237.7, 100.6 and 80.1%, respectively, displaying the excellent sensitivity to nitroaromatic explosives. With the change of the bending degrees, the changes of response time and recovery time is no more than 11.8% (Fig. 5b, c). Importantly, the response time and recovery time of flexible PCFP to three nitroaromatic explosives are no more than 8.1 s and 1.9 s, respectively, showing the fast response and
recovery. This means that at RT the PCFP can detect explosives once in 10.0 s. Fast response-recovery speed, high sensitivity and excellent bending stability imply that the PCFP has potential application prospects. Although the concentration of saturated TNT vapour at RT is not the highest, the PCFP has the highest response to TNT. This may be because TNT has three nitro groups, whereas DNT has only two nitro groups, so TNT has the stronger ability to
ro of
seize electrons from PANI (Fig. 5d). As reported, TNT is able to form
Meisenheimer complexes and acid-base pair complexes with amino groups,
even in the gas phase [29,30]. Thus, although the concentration of TNT (9.1
-p
ppb) is lower than that of DNT (411 ppb) [31], the PCFP still shows the
re
maximum response to TNT. Similarly, PA with three nitro groups also has the strong ability to seize electrons (Fig. 5d). When PANI was exposed to PA
lP
vapour, the PA adsorbed on PANI rich in imino and took electrons from PANI.
na
This process is equivalent to increasing the hole carrier of PANI and improves the conductivity. In addition, it is reported that PA having strong acidity can be
ur
used as dopant to improve the conductivity of PANI [32, 33]. The PA adsorbed on the surface of PANI may act as an acidic dopant, thus improving the
Jo
conductivity of PANI. Although the saturated concentration of PA at RT is only 0.97 ppb [34], the above two reasons contributed to the highly sensitive response of PANI to PA.
ro of
Fig. 6. Sensing curves of the PCFP tested before and after bending 1000 and
2000 times with a bending angle of 40° (a) 9.1 ppb of TNT, (b) 0.97 ppb of PA
-p
and (c) 411 ppb of DNT under different bending times, (d) sensing responses of
re
TNT, PA and DNT under different bending times.
Accurate control of repeated mechanical bending with an angle of 40° of
lP
flexible PCFP was implemented by vernier calipers (Scheme S2). The flexural
na
stability for the repeated mechanical bending was displayed in Fig. 6. When subjected to 2000 bending, the PCFP shows the decreases of 7.9, 7.9 and 7.2%
ur
in responses for TNT, PA and DNT, respectively. After bending 2000 times, the morphology of the PCFP has hardly changed from macroscopic to
Jo
microcosmic (Fig. S3), compared with that in Fig. 2b, c. The PANI fibers rooted on fibers of filter paper contributed to the good flexural stability, beneficial for preserving its sensing performance to a large extent. The LOD to TNT and PA was estimated to better evaluate the sensing performances of the PCFP.
re
-p
ro of
3.3 Detection limit, reproducibility and selectivity
lP
Fig. 7. Relation between responses of flexible PCFP and vapor concentrations at RT of (a) TNT, (c) PA, (e) DNT; the fitting plots of response vs concentration of (b) TNT,
na
(d) PA, (f) DNT.
Detection limit is an important parameter for estimating gas sensors. The
ur
relation between responses and vapour concentrations at RT were shown in Fig.
Jo
7. For TNT, PA and DNT, a nearly linear dependency between the response and the concentration was observed (Fig. 7b, d, f). The linear relationship shows that the adsorption of explosives on PANI fibers has not yet reached saturation. According to the fitting results in Fig. 7b, d, f, the estimated LOD (defined as LOD = 3 SD/m, where m is the slope of the linear part of the calibration curve and SD is the standard deviation of noise in the response
curve) for TNT, PA and DNT is determined to be 0.094, 0.029 and 15.04 ppb, respectively. These results show the high sensitivity of the PCFP to TNT and
-p
ro of
PA.
re
Fig. 8. Sensing curves of four different flexible PCFP to (a) 9.1 ppb of TNT, (b) 0.97 ppb of PA and (c) 411 ppb of DNT at 0o bending angle, (d) average sensing
lP
responses and standard deviation over three continuous responses.
na
To determine the reproducibility of different flexible PCFPs, the sensing curves of four different flexible PCFP to 9.1 ppb of TNT, 0.97 ppb of PA and 411 ppb of
ur
DNT at 0o bending angle were evaluated in Fig. 8. As shown in the Fig. 8a-c, the sensing curves of four different flexible PCFPs to TNT, PA and DNT
Jo
displayed good repeatability. Using these data, average sensing responses and standard deviation over three continuous responses of four different flexible PCFPs to TNT, PA and DNT were shown in Fig. 8d. This is shown more detail in the column statistics of the average responses of the four PCFPs (Fig. 8d) and the average responses to TNT, PA and DNT were 239.9±4.7, 101.7±2.8 and 82.3
±2.2, respectively. Good repeatability should be attributed to the uniform and firm growth of PANI fibers on filter paper. Selectivity and anti-interference capability are also important parameters for explosive sensors. Aniline, benzene, ethylenediamine, acetone and toluene are common VOCs and may interfere with the detection of explosives. These vapors are used to test the antiinterference ability of flexible PCFP. As shown in Fig. S4a-e, the responses of
ro of
flexible PCFP to 1000 ppm of aniline, benzene, ethylenediamine, acetone and
toluene did not exceed -36%. It can be seen that the responses of flexible PCFP to these common VOCs are downward (negative) and relatively small, which
-p
shows that it has good anti-interference ability to common VOCs. Nitrobenzene
re
and 2, 4-dinitrophenol have similar structures to TNT, PA and DNT, so they are used to evaluate the selectivity. The responses of flexible PCFP to the saturated
lP
vapour of nitrobenzene (300 [35] or 400 [36] ppm) and 2, 4-dinitrophenol at RT
na
reached 32.6% and 24.5% (Fig. S4g, h), respectively, which were much smaller than the responses to TNT, DNT and PA, showing the good selectivity.
ur
Nitrobenzene and 2, 4-dinitrophenol are reported to be less capable of withdrawing electrons than TNTand DNT [29, 30]. Therefore, TNT and DNT
Jo
have a higher ability to create charge-transfer complexes with the amino groups, induce a stronger conductivity change than other nitrosubstituted aromatic molecules of a less electron-withdrawing nature, contributing to the good selectivity. Relative humidity (RH) is a more common interference factor, which varies with the change of region and climate. Therefore, we focus on the
effect of varying RH on the flexible PCFP. As shown in Fig. S4f, the average response of flexible PCFP to 100% RH was less than -5.1%, and the response to 100% RH is downward. In addition, the impact of different RH on explosive
na
lP
re
-p
ro of
detection has also been assessed.
Fig. 9. Sensing curves of flexible PCFP to (a) 9.1 ppb of TNT, (b) 0.97 ppb of PA
ur
and (c) 411 ppb of DNT under different humidity environments, (d) sensing
Jo
responses, (e) response times, (f) recovery times and standard deviation over three continuous responses of flexible PCFP. The controlled humidity environments were achieved using
supersaturation aqueous solutions of different salts of MgCl2, NaCl and KNO3 in a closed glass vessel at room temperature, which yielded 33, 75, and 95% RH, respectively [37]. Solid particles of explosives were placed in the controlled
humidity environments for about 48 h to produce saturated vapors of TNT, DNT and PA at 25 ± 1 °C. At the same time, the temperature and RH of the testing room were controlled at 25 ± 1 °C and 35% ± 2% respectively by an air conditioning system. In the sensing tests, the RH of the reference air is 35%. As shown in Fig. 9 a-f, with the increase of RH, the average responses of flexible PCFP to three explosives decrease gradually, but the average response time
ro of
increases significantly. This may be that the response of flexible PCFP to
humidity is downward, while the responses to nitroaromatic explosives are
upward. Therefore, there is competition between the two sensing signals. Under
-p
the condition of constant explosive concentration, the sensing signals decreases
re
slightly with the increase of RH. At the same time, the average response time of the sensor increases correspondingly with the increase of RH due to the
lP
competition effect. This means that with the increase of RH, more time is
na
needed to achieve the same response. However, since the RH of the reference air is the same during the test, the recovery time of the sensor has hardly
ur
changed significantly. It should be pointed out that although 33% RH and 35% RH are controlled by the supersaturation aqueous solutions of MgCl2 and an air
Jo
conditioning respectively, the responses to TNT, DNT and PA are very close under two humidity environments, which proves that the controlled humidity produced by the two methods is feasible and reliable. This shows that RH does have an impact on explosive detection, especially on response time, but it has a relatively small impact on responses and recovery time.
Table 1. Comparison of the flexible PCFP and other chemiresistive sensors. Recovery Ref. time [6] -~4 s ~6.3 s ~7 s ~5 s
[38]
--
[40]
~75 s ~80 s ~100 s ~6 s ~5 s ~600s
[5]
[39]
ro of
Response Response time 20% >10 min 8% 45.5% ~4.3 s 38.9% ~5.3 s 36.1% ~4.7 s 47% ~5 s 38% 10% ~30 s 2% 6.3% ~80 s 40% ~120 s 4% ~70 s 46.9% ~4 s 45.4% ~3 s 5.51% ~400s 7 237.7% ~4.6 s 80.1% ~2.8 s 100.6% ~8.1 s
-p
Analytes/ concentration ZnO nanowire TNT, 60 ppb SWNT TNT, 8 ppb Ni-ZnO TNT, 9.1 ppb Fe-ZnO DNT, 411 ppb Fe-ZnO PA, 0.97 ppb Titania(B) nanowires TNT, 9 ppb DNT, 180 ppb GaN/TiO2hybrids TNT, 100 ppb DNT,100 ppb SiNWs TNT, 9.1 ppb array/TiO2/rGO DNT, 411 ppb PA, 0.97 ppb Mn:ZnS NCs with TNT, 9.1 ppb 2+ 5% Mn DNT, 411 ppb MWNTs-PANI PA,1ppb WO3-dopedZnO PA, PCFP TNT, 9.1 ppb DNT, 411ppb PA, 0.97 ppb
re
Sensing materials
~1.7 s ~1.9 s ~1.5 s
[4]
[2] [1]
This work
lP
In addition, the PCFP and the latest explosive sensors were compared and the results were listed in Table 1. As can be seen from Table 1, the PCFP
na
perform better both in recovery speed and sensitivity than recent explosive sensors [4-6, 38-40]. Although the response times of the PCFP are not the
ur
shortest, they are less than 8.1 s, basically achieving the real-time detection of
Jo
explosives. In particular, the PCFP is most sensitive to TNT, DNT and PA, compared with other sensors listed in table 1. The responses to saturated vapours of TNT, DNT and PA at RT are 237.7, 80.1 and 100.6%, respectively, which are about several times the responses reported in other literatures [4-6, 38-40]. It is well known that the gas sensing process occurs mainly on the surface of sensing materials [41, 42]. Therefore, the effective exposure of
sensing materials largely determines the sensor's sensing performance [43], which should be attributed to the formation process and structure of PANI prepared by spraying. After spraying, the small droplets of the PANI precursor adhered to the filter paper (Scheme S3). The precursor droplets adhered to filter paper slowly diffused on filter paper and the volume of droplets gradually decreased. The precursor then reacted to form micro/nano PANI fibers on fibers
ro of
of filter paper.
ur
na
lP
re
-p
3.4 Analysis of Possible Sensing Mechanism
Fig. 10. Illustration of high sensitivity and good bending stability of flexible PCFP.
Jo
In this way, the following three factors contribute to the highly sensitive and fast responses. First, flower-like structures effectively prevent from the aggregation of PANI fibers and produce a large number of gas passages (Fig. 10). As a result, the high permeability of filter paper and hierarchical flowerlike PANI allows explosive molecules sufficiently and rapidly to contact with
PANI fibers by the rapid diffusion through the gas passages (as shown by the red dot arrow in Scheme S3) [41, 44]. Second, micron-scale PANI fibers connecting the flower-like PANI like bridges, interlacing links between flowerlike PANI fibers and one-dimensional structure of PANI fibers facilitate the rapid transport and transfer of charges between PANI fibers and nitroaromatic explosives (Fig. 10, Fig. 2c, d) [6, 42, 43]. Third, the interaction between
ro of
electron-rich amino groups of PANI and electron-deficient nitro groups of
nitroaromatic explosives also contributes to the rapid and selective responses.
Meanwhile, it can be seen that the flower-like PANI fibers rooted on the filter
-p
paper are interlaced with each other and still interlaced with each other in the
re
process of bending, forming many stable percolation paths (Fig. 10). The interlaced flower-like structures contribute to the good flexural stability, which
lP
may also inspire the development of stretchable flexible sensors. It should be
na
pointed out that with the increase of bending degree, the PANI fibers growing on filter paper become more discrete, which is conducive to the adsorption and
ur
desorption of target gas molecules. However, from the above sensing data, the average responses and response time of flexible PCFP to target analytes do not
Jo
change significantly with the increase of bending degree. This may be due to the fact that PANI fibers growing on filter paper have formed hierarchical flower-like structures and have enough high permeability. Therefore, the enhanced permeability by the increase of bending degree hardly changes the sensing performance of
flexible PCFP. It also shows that the hierarchical flower-like structure provides a good structural basis for flexural stability of flexible sensors.
4. Conclusions In order to realize the high sensitivity and fast detection of nitroaromatic explosives and to solve the challenge brought by the traditional sensing substrates, a flexible explosive sensor based on filter paper has been prepared
ro of
by spraying for the first time. After spraying, the PANI fibers growing on the filter paper formed a special interlaced flower-like structure, providing high
permeability and flexural stability. The responses of flexible PCFP to TNT, PA
-p
and DNT run up to about 237.7, 100.6 and 80.1% respectively, and the
re
response time and recovery time are no more than 8.1 s and 1.9 s respectively. The response fluctuation of the paper-based sensor is less than 7% in the
lP
bending process and the decrease of responses is less than 7.9% after 2,000
na
bends of 40o. Furthermore, the flexible sensor shows good selectivity and antiinterference ability. Importantly, our research proves that the spraying method
ur
is suitable for economical, efficient and large-scale preparation of paper-based
Jo
flexible sensors.
Acknowledgements The authors thank the financial support from Natural Science Foundation of Xinjiang Uygur Autonomous Region (2019D01C019), China Postdoctoral Science Foundation (2017M613255), Joint Funds of NSFC-Xinjiang of China
(U1703251) and National Natural Science Foundation of China (21964016, 11664038, 61864011).
Notes The authors declare no competing financial interest.
ro of
Appendix A. Supplementary data
Supplementary material associated with this article can be found in the online
Jo
ur
na
lP
re
-p
version.
References
Jo
ur
na
lP
re
-p
ro of
[1] A. Lichtenstein, E. Havivi, R. Shacham, E. Hahamy, R. Leibovich, A. Pevzner, V. Krivitsky, G. Davivi, I. Presman, R. Elnathan, Supersensitive finger printing of explosives by chemically modified nanosensors arrays, Nat. Commun 5(2014)4195. [2] Y. Geng, M. A. Ali, A. J. Clulow, S. Fan, P. L. Burn, I. R. Gentle, P. Meredith, P. E. Shaw, Unambiguous detection of nitrated explosive vapours by fluorescence quenching of dendrimer films, Nat. Commun 6(2015)8240. [3] L. A. Pinnaduwage, A. Gehl, D. L. Hedden, G. Muralidharan, T. Thundat, R. T. Lareau, T. Sulchek, L. Manning, B. Rogers, M. Jones, Explosives: a microsensor for trinitrotoluene vapour, Nature 425(2003)474-474. [4] Z. Wu, C. Zhou, B. Zu, Y. Li, X. Dou, Contactless and Rapid Discrimination of Improvised Explosives Realized by Mn2+ Doping Tailored ZnS Nanocrystals, Adv. Funct. Mater 26 (2016)4578-4586. [5] Z. Yang, X. Dou,S. Zhang, L. Guo, B. Zu, Z. Wu, H. Zeng, A HighPerformance Nitro‐Explosives Schottky Sensor Boosted by Interface Modulation, Adv. Funct. Mater 25(2015)4039-4048. [6] P. C. Chen, S. Sukcharoenchoke, K. Ryu, L. G. D. Arco, A. Badmaev, C. Wang, C. Zhou, 2,4,6-Trinitrotoluene (TNT) Chemical Sensing Based on Aligned Single-Walled Carbon Nanotubes and ZnO Nanowires, Adv. Mater 22 (2010)1900-1904. [7] J. M. Schnorr, D. V. D. Zwaag, J. J. Walish, Y. Weizmann, T. M. Swager, Sensory Arrays of Covalently Functionalized Single-Walled Carbon Nanotubes for Explosive Detection, Adv. Funct. Mater 23(2013)5285-5291. [8] S. Bai, C. Sun, P. Wan, C. Wang, R. Luo, Y. Li, J. Liu, X. Sun, Transparent conducting films of hierarchically nanostructured polyaniline networks on flexible substrates for high-performance gas sensors. Small 11(2015)306-310. [9] B. H. Robinson, E-waste: an assessment of global production and environmental impacts, Sci. Total. Environ 408(2009)183-191. [10] L. Wang, D. Chen, K. Jiang, G. Shen, New insights and perspectives into biological materials for flexible electronics,Chem. Soc. Rev 46(2017)67646815. [11] H. Liu, M. Li, O. Voznyy, L. Hu, Q. Fu, D. Zhou, Z. Xia, E. H. Sargent, J. Tang, Physically Flexible, Rapid-Response Gas Sensor Based on Colloidal Quantum Dot Solids, Adv. Mater 26(2014)2718-2724. [12] S. Ammu, V. Dua, S. R. Agnihotra, S. P. Surwade, A. Phulgirkar, S. Patel, Manohar, S. K. all-organic chemiresistor for detecting chemically aggressive vapors, J. Am. Chem. Soc 134(2012)4553-4556. [13] J. K. Zhang, L. Huang, Y. J. Lin, L. Chen, Z. Y. Shen, Q. Chen, W. Z. Shi, Pencil-trace on printed silver interdigitated electrodes for paper-based NO2 gas sensors,Appl. Phys. Lett 106(2015)143101.
Jo
ur
na
lP
re
-p
ro of
[14] S. Ammu, V. Dua, S. R. Agnihotra, S. P. Surwade, A. Phulgirkar, S. Patel, S. K. Manohar, Flexible, All-Organic Chemiresistor for Detecting Chemically Aggressive Vapors, J. Am. Chem. Soc 134(2012)4553-4556. [15] K. A. Mirica, J. G. Weis, J. M. Schnorr, B. Esser, T. M. Swager, Mechanical Drawing of Gas Sensors on Paper, Angew. Chem. Int. Edit 51(2012)1074010745. [16] K. A. Mirica, J. M. Azzarelli, J. G. Weis, J. M. Schnorr, T. M. Swager, Rapid prototyping of carbon-based chemiresistive gas sensors on paper, P. Natl. Acad. Sci. USA 110(2013)E3265-E3270. [17] L. R. Shobin, S. Manivannan, Carbon nanotubes on paper: Flexible and disposable chemiresistors, Sens. Actuators, B 220(2015)1178-1185. [18] X. Dou, J. Wang, X. Lu, M. Zhang, Y. Qin, Y. Wang, P. Zhang, Z. X. Guo, A convenient approach to producing a sensitive MWCNT-based paper sensor, RSC Adv 6(2016)112241-112245. [19] J. Fei, Y. Cui, X. Yan, Y. Yang, K. Wang, J. Li, Controlled fabrication of polyaniline spherical and cubic shells with hierarchical nanostructures, Acs Nano 3(2009)3714-3718. [20] S. Cho, O. Kwon, S. You, J. Jang, Shape-controlled polyaniline chemiresistors for high-performance DMMP sensors: effect of morphologies and charge-transport properties, J. Mater. Chem. A 1(2013)5679-5688. [21] Y. Zhang, J. J. Kim, D. Chen, H. L. Tuller, G. C. Rutledge, Electrospun Polyaniline Fibers as Highly Sensitive RT Chemiresistive Sensors for Ammonia and Nitrogen Dioxide Gases, Adv. Funct. Mater 24(2014)40054014. [22] S. Huang, Q. He, S. Y. Xu, L. Y. Wang, Polyaniline-Based Photothermal Paper Sensor for Sensitive and Selective Detection of 2,4,6-Trinitrotoluene, Anal. Chem 87(2015)5451-5456. [23] Z. C. Hu, B. J. Deibert, J. Li, Luminescent metal-organic frameworks for chemical sensing and explosive detection, Chem. Soc. Rev 43(2014)58155840. [24] F. Akhgari, H. Fattahi, Y. M. Oskoei, Recent advances in nanomaterial-based sensors for detection of trace nitroaromatic explosives, Sens. Actuators, B 221(2015)867-878. [25] P. N. Manoudis, I. Karapanagiotis, A. Tsakalof, I. Zuburtikudis, Panayiotou C.Superhydrophobic composite films produced on various substrates, Langmuir 24(2008)11225–11232. [26] I. S. Bayer, A. Steele, P. J. Martorana, E. Loth, L. Miller, Superhydrophobic cellulose-based bionanocomposite films from Pickering emulsions. Appl. Phys. Lett 94(2009)163902. [27] Z. F. Wu, H. Wang, X. Y. Tian, P. Cui, X. Ding, X. Z Ye. Facile preparation of superhydrophobic surfaces with enhanced releasing negative air ions by a simple spraying method, Compos. Sci. Technol 94 (2014)111-116.
Jo
ur
na
lP
re
-p
ro of
[28] M. Irimia-Vladu, N. Marjanovic, A. Vlad, A. M. Ramil, G. Hernandez-Sosa, R. Schwoödiauer, S. Bauer, N. S. Sariciftci, Vacuum-Processed PolyanilineC60 Organic Field Effect Transistors, Adv. Mater 20(2008)3887-3892. [29] Y. Engel, R. Elnathan, A. Pevzner, G. Davidi, E. Flaxer, F. Patolsky, Supersensitive Detection of Explosives by Silicon Nanowire Arrays, Angew Chem Int Edit 49(2010) 6830-6835. [30] J. Yinon, J. V. Johnson, U. R. Bernier, R. A. Yost, H. T. Mayfield, W. C. Mahone, C. Vorbeck, Reactions in the mass spectrometry of a hydride meisenheimer complex of 2,4,6-trinitrotoluene (TNT), J Mass Spectrom 30 (1995) 715-722. [31] H. Östmark, S. Wallin, H. G. Ang, Vapor Pressure of Explosives: A Critical Review, Propell. Explos. Pyrot 37(2012)12-23. [32] C. D. C. Dhivya, S. A. A. Vandarkuzhali, R. S. N. Radha, Synthesis and Characterisation of Polyaniline Using Picric Acid as an Organic Dopant, Indian J. Appl. Res 3(2011)62-65. [33] S. M.Ahmed,Preparation and degradation of highly conducting polyaniline doped with picric acid, Eur. Polym. J 38(2002)1151-1158. [34] J. E. Brady, J. L. Smith, C. E. Hart, J. Oxley, Estimating Ambient Vapor Pressures of Low Volatility Explosives by Rising-Temperature Thermogravimetry, Propell. Explos. Pyrot 37(2012)215-222. [35] Y. Y. Lv, W. Xu, F. W. Lin, J. Wu, Z. K. Xu, Electrospun nanofibers of porphyrinated polyimide for the ultra-sensitive detection of trace TNT, Sens. Actuators, B 184(2013)205-211. [36] R. Y. Tu,B. H. Liu, Z. Y. Wang, D. M. Gao, F. Wang, Q. L. Fang, Z. P. Zhang, Amine-capped ZnS-Mn2+ nanocrystals for fluorescence detection of trace TNT explosive, Anal. Chem 80(2008)3458-3465. [37] Z. Li, H. Zhang, W. Zheng, W. Wang, H. Huang, C. Wang, A. G. MacDiarmid, Y. Wei, Highly Sensitive and Stable Humidity Nanosensors Based on LiCl Doped TiO2 Electrospun Nanofibers, J Am Chem Soc 130 (2008) 5036-5037. [38] J. Qu, Y. Ge, B. Zu, Y. Li, X. Dou, Transition-Metal-Doped p-Type ZnO Nanoparticle-Based Sensory Array for Instant Discrimination of Explosive Vapors, Small 12(2016)1369-1377. [39] D. Wang, A. Chen, S. H. Jang, H. L.Yip, A. K. Y. Jen, Sensitivity of titania(B) nanowires to nitroaromatic and nitroamino explosives at RT via surface hydroxyl groups, J. Mater.Chem 21(2011)7269-7273. [40] G. S. Aluri, A. Motayed, A. V. Davydov, V. P. Oleshko, K. A. Bertness, N. A. Sanford, M. V. Rao, Highly selective GaN-nanowire/TiO2-nanocluster hybrid sensors for detection of benzene and related environment pollutants, Nanotechnology 22(2011)295503. [41] M. E. Franke, T. J. Koplin, U. Simon, Metal and metal oxide nanoparticles in chemiresistors: Does the nanoscale matter?, Small 2(2006)36-50.
Jo
ur
na
lP
re
-p
ro of
[42] Z. Yang, X. Dou, Emerging and Future Possible Strategies for Enhancing 1D Inorganic Nanomaterials‐Based Electrical Sensors towards Explosives Vapors Detection, Adv. Funct. Mater 26(2016)2406-2425. [43] T. Shaymurat, Q. X. Tang, Y. H. Tong, L. Dong, Y. C. Liu, Gas Dielectric Transistor of CuPc Single Crystalline Nanowire for SO2 Detection Down to Sub-ppm Levels at RT, Adv. Mater 25(2013)2269-2273. [44] J. H. Lee, Gas sensors using hierarchical and hollow oxide nanostructures: Overview, Sens. Actuators, B 140(2009)319-336.
Biographies
Weiyu Zhang is a postgraduate student in School of Physics Science and Technology, Xinjiang University.
ro of
Zhaofeng Wu received the Ph.D. Degree (2014) from the Institute of Solid State Physics, Chinese Academy of Sciences and afterwards he worked as a postdoc at Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences (2014-2016). Since June 2016, Dr. Wu has been an associate professor, master instructor in Xinjiang University. His research are mainly engaged in the nanofunctional materials and composite materials.
-p
Haiming Duan is a professor, at School of Physics Science and Technology, Xinjiang University and head of School of Physics Science and Technology. He received his Master Degree (1995) from Xinjiang University and Ph.D. Degree of condensed matter physics (2001) from the Institute of Solid State Physics, Chinese Academy of Sciences, respectively.
re
Dianzeng Jia is a doctor, professor and doctoral supervisor in Xinjiang University. Prof. Jia is also the director of key laboratory of energy materials chemistry, ministry of education, vice president of Xinjiang University.
lP
Yali Cao is a doctor, professor and doctoral supervisor in Xinjiang University. Prof. Cao is mainly engaged in the research of nano-functional materials, including nanophotocatalysts, nano-electrode materials, nano-gas sensing materials, etc.
na
Jixi Guo is a doctor, professor and doctoral supervisor in Xinjiang University. Prof. Guo is mainly engaged in photoelectric functional materials, etc.
Jo
ur
Mengqiu Long is a doctor, professor and doctoral supervisor in Central South University. Prof. Long is engaged in theoretical research on the electronic structure and charge transport properties of nanostructures and materials.