Please cite this article as: P. Rattanarat, A. Suea-Ngam, N. Ruecha, W. Siangproh, C.S. Henry, M. Srisa-Art, O. Chailapakul, Graphene-Polyaniline Modified Electrochemical Droplet-Based Microfluidic Sensor for High-throughput Determination of 4-Aminophenol, Analytica Chimica Acta (2016), doi: 10.1016/j.aca.2016.03.010. This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
ACCEPTED MANUSCRIPT 1
Graphene-Polyaniline Modified Electrochemical Droplet-Based Microfluidic Sensor for
2
High-throughput Determination of 4-Aminophenol
3
Poomrat Rattanarat,a Akkapol Suea-Ngam,a Nipapan Ruecha,c Weena Siangproh,d Charles S.
5
Henry,e,f, Monpichar Srisa-Art, a,b and Orawon Chailapakul a,g,*
6
RI PT
4
7
a
8
Chemistry, Faculty of Science, Chulalongkorn University, Patumwan, Bangkok 10330,
9
Thailand.
M AN U
SC
Electrochemistry and Optical Spectroscopy Research Unit (EOSRU), Department of
10
b
11
Faculty of Science, Chulalongkorn University, Patumwan, Bangkok 10330, Thailand.
12
c
13
Patumwan, Bangkok 10330, Thailand.
14
d
15
Wattana, Bangkok 10110, Thailand.
16
e
17
States.
18
f
19
United States.
20
g
21
Chulalongkorn University, Patumwan, Bangkok 10330, Thailand.
Chromatography and Separation Research Unit (ChSRU), Department of Chemistry,
TE D
Program in Macromolecular Science, Faculty of Science, Chulalongkorn University,
Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23,
EP
Department of Chemistry, Colorado State University, Fort Collins, CO 80523, United
AC C
School of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523,
National Center of Excellent of Petroleum, Petrochemicals and Advanced Materials,
22 23 24
*Corresponding authors at: E-mail address:
[email protected]
ACCEPTED MANUSCRIPT GRAPHICAL ABSTRACT
RI PT
1
2
RESEARCH HIGHLIGHTS
4
• A novel combination of G-PANI/CPE and droplet-based microfluidic device for
5
determination of 4-AP was achieved.
6
• G-PANI nanocomposite increases the surface area and improved electrochemical sensitivity
7
of the electrode.
8
• This novel droplet-based system was successfully applied for 4-AP monitoring in
9
commercial PA samples.
M AN U
TE D
EP AC C
10
SC
3
ACCEPTED MANUSCRIPT 1
ABSTRACT We report herein the first development of graphene-polyaniline modified carbon paste
3
electrode (G-PANI/CPE) coupled with droplet-based microfluidic sensor for high-throughput
4
detection of 4-aminophenol (4-AP) in pharmaceutical paracetamol (PA) formulations. A
5
simple T-junction microfluidic platform using an oil flow rate of 1.8 µL/min and an aqueous
6
flow rate of 0.8 µL/min was used to produce aqueous testing microdroplets continuously.
7
The microchannel was designed to extend the aqueous droplet to cover all 3 electrodes,
8
allowing for electrochemical measurements in a single droplet. Parameters including flow
9
rate, water fraction, and applied detection potential (Edet) were investigated to obtain optimal
10
conditions. Using G-PANI/CPE significantly increased the current response for both cyclic
11
voltammetric detections of ferri/ferrocyanide [Fe(CN)6]3-/4- (10 times) and 4-AP (2 times),
12
compared to an unmodified electrode. Using the optimized conditions in the droplet system,
13
4-AP in the presence of PA was selectively determined. The linear range of 4-AP was 50-
14
500 µM (R2 = 0.9972), limit of detection (LOD, S/N=3) was 15.68 µM, and limit of
15
quantification (LOQ, S/N=10) was 52.28 µM. Finally, the system was used to determine 4-
16
AP spiked in commercial PA liquid samples and the amounts of 4-AP were found in good
17
agreement with those obtained from the conventional capillary zone electrophoresis/UV-
18
Visible spectrophotometry (CZE/UV-Vis).
19
employed for a high-throughput screening (at least 60 samples h-1) of pharmaceutical purity
20
requiring low sample and reagent consumption.
SC
M AN U
TE D
EP
The proposed microfluidic device could be
AC C
21
RI PT
2
22
KEYWORDS:
droplet-based
microfluidics,
23
polyaniline, 4-aminophenol, paracetamol
electrochemical
detection,
graphene,
ACCEPTED MANUSCRIPT 1
1. INTRODUCTION
2 3
Since the mid-1940s, paracetamol (PA, acetaminophen or N-acetyl-p-
4
aminophenol) has been commonly used as an antipyretic and analgesic drug around
5
the world [1-2].
6
suppositories, have been available and highly effective for a variety of patients
7
including children, pregnant women, and the elderly. Unfortunately, 4-aminophenol
8
(4-AP) residue might be present as an impurity in PA formulations obtained from its
9
synthesis or as a result of degradation [3]. Consuming 4-AP unintentionally can cause
10
numerous pathologies (e.g. nephrotoxicity and hepatotoxicity) [3-5]. The European,
11
United States, British, German, and Chinese Pharmacopoeias have set the maximum
12
allowable limit of 4-AP in the PA drug formulations at 50 ppm (0.005% w/w) [5].
13
Several analytical approaches to determine 4-AP in PA formulations have been
14
developed including high performance liquid chromatography (HPLC) coupled with
15
UV-visible [6-7] or fluorescence [8] detection, electrochemical detection [9], capillary
16
electrophoresis [10-11], and flow-based analytical techniques [4, 12]. Although these
17
techniques offer highly selective, and sensitive quantification of 4-AP in PA
18
formulations, these techniques are time consuming, have high operation costs, and are
19
available only in sophisticated laboratories.
RI PT
SC
M AN U
TE D
EP
AC C
20
Many PA formulations, such as tablets, syrups, injections, and
Recently, droplet microfluidic systems have held great promise for analytical
21
measurements due to their portability, fast analysis time, low manufacturing cost, low
22
reagent/sample
23
microfluidic systems are capable of generating and manipulating small droplets
24
encapsulated by an immiscible phase. Among other microfluidic platforms, droplet
25
microfluidics has gained attention because of superior mixing efficiency and low
consumption,
and
high-throughput
screening
[13].
Droplet
ACCEPTED MANUSCRIPT dispersion and adsorption of sample within the microchannel [14]. The utility of
2
droplet-based technology has been demonstrated for many applications, such as
3
biomedical diagnosis [15-16], food safety [17-18], and environmental monitoring [19].
4
Other demonstrated applications include protein crystallization [20] and enzymatic
5
kinetic assays [21], emulsion-based polymerase chain reaction [22], chemical
6
synthesis [23-24], and single cell-based analysis [25].
7
microfluidics, various detection methods have been used for content detection
8
including
9
spectroscopy [28], absorption spectroscopy [29], and bright-field microscopy [30].
10
Although these techniques offer highly selective, sensitive and accurate quantification,
11
the main disadvantage of these techniques are high equipment cost and challenge of
12
coupling them with miniaturized systems for on-site applications.
fluorescence
[26],
mass
For detection in droplet
spectrometry
[27],
Raman
M AN U
SC
laser-induced
RI PT
1
Electrochemical detection is an attractive and alternative detection method for
14
microfluidics because it is low cost, high speed, high sensitivity, cost-effectiveness,
15
and independence of sample turbidity or optical path length [31]. Currently, there
16
have been a few reports on electrochemical detection for droplet microfluidic systems.
17
For example, Liu et al. used chronoamperometry for the detection of droplet contents
18
and characterization of droplet generation (e.g. frequency, size and velocity) [32].
19
Han et al. developed an amperometric droplet microfluidic device to investigate the
20
kinetics of enzymatic decomposition of H2O2 using catalase [33]. Gu et al. used a Pt-
21
black modified electrochemical droplet-based microfluidic sensor for enzymatic
22
glucose assays in biological fluids [34]. Itoh et al. demonstrated a novel droplet-based
23
microdevice with an electrochemical ATP-sensing function for fish freshness
24
determination [35].
AC C
EP
TE D
13
ACCEPTED MANUSCRIPT The use of nanomaterials to improve electrode performance in microfluidic
2
devices has drawn increasing attention in recent years. Numerous nanomaterials (e.g.
3
gold nanoparticles, silver nanoparticles, single-wall carbon nanotubes, and multi-wall
4
carbon nanotubes) are currently available and can increase active surface area of the
5
working electrode, leading to enhanced electrochemical sensitivity and conductivity
6
[34, 36-38]. Graphene (G) has received substantial attention for chemical modification
7
of electrodes [39], owing to its large surface area, extraordinary electrical
8
conductivity, high mechanical strength and potentially low manufacturing cost. In
9
addition, G has been also used to modify electrode surface in order to improve the
10
electrochemical properties of the electrodes. One problem associated with G-based
11
electrode modification is the potential for self-agglomeration of pure G on the
12
electrode surface. One solution is use of a nanocomposite consisting of conducting
13
polymer and G to increase the distribution of graphene [40].
14
polymers, polyaniline (PANI) has been widely used for electrode modification because
15
of its inherent electrochemical properties, biocompatibility and stability [41-42].
16
Previous reports have used G-PANI hybrid modified electrochemical sensors for
17
electrochemiluminescent detection of luminol [43], voltammetric determination of
18
dopamine [41] and dobutamine [44], and electrochemical immunoassays for estradiol
19
[45] and salbutamol [46]. To the best of our knowledge, there are no previous reports
20
combining a novel G-PANI modified electrodes and droplet microfluidics for
21
electrochemical determination of 4-AP.
Among conducting
AC C
EP
TE D
M AN U
SC
RI PT
1
22
Herein, the aim of this work is to develop a high-throughput and sensitive
23
method using G-PANI modified electrochemical droplet-based microfluidic sensor for
24
determination of 4-AP in pharmaceutical PA products. An improved selectivity for 4-
25
AP was achieved using G-PANI modified carbon-paste electrodes (G-PANI/CPE)
ACCEPTED MANUSCRIPT operating at the optimized detection potential for highly selective detection of 4-AP in
2
the presence of PA. This system offers an alternative method to measure 4-AP level in
3
acceptable concentration range. Finally, this approach was successfully applied for the
4
determination of 4-AP in commercial PA liquid samples, giving high correlation with
5
a CZE/UV-Vis method. Accordingly, measurements using this approach can provide
6
a fast and high-throughput route and could be an ideal platform for screening of purity
7
in pharmaceutical products with small sample consumption.
8
development of this microfluidic model can be further extended to various applications
9
such as medical testing, environmental monitoring and quality control of foods or
SC
beverages.
11 12
Furthermore, the
2. EXPERIMENTAL
M AN U
10
RI PT
1
2.1 Materials and chemicals
14
The following materials were used as received: poly(dimethylsiloxane)
15
(PDMS) Sylgard 184 eleastomer kit (Dow Corning, USA), mineral oil (Perkin Elmer,
16
Thailand), silver paint (SPI supplies, USA), graphite powder (≤20 µm, Sigma-Aldrich,
17
Singapore), and graphene (A.C.S Medford, USA).
18
grade: sodium chloride (NaCl: Merck, Thailand), disodium hydrogen phosphate
19
(Na2HPO4: Merck, Thailand), potassium dihydrogen phosphate (KH2PO4: Carlo
20
ERBA, Thailand), potassium chloride (KCl: Ajax Finechem, Thailand), and ethanol
21
(Merck, Thailand). Potassium ferricyanide (K3[Fe(CN)6]) and potassium ferrocyanide
22
(K4[Fe(CN)6]) were obtained from Sigma-Aldrich (Singapore).
23
camphor-10-sulfonic acid (C10H16O4S) were purchased from Merck (Darmstadt,
24
Germany). N-Methyl-2-pyrrolidone (NMP), 4-aminophenol (4-AP) and paracetamol
25
(PA) were purchased from Sigma-Aldrich (Singapore).
All chemicals were analytical
AC C
EP
TE D
13
Polyaniline and
Commercial PA drugs
ACCEPTED MANUSCRIPT consisting of Infants’ TYLENOL® (Janssen-Cilag, Ltd., Thailand), TEMPRA®
2
(Taisho Pharmaceutical Co., Ltd., Thailand), SARA® (Thai Nakorn Patana Co., LTD,
3
Thailand) were purchased from a local pharmacy in Thailand. For droplet generation,
4
a 10:2 (v/v) mixture of perfluorodecalin (mixture of cis and trans, 95%, Sigma-
5
Aldrich, Germany) and 1H, 1H, 2H, 2H-perfluoro-1-octanol (97%, Sigma-Aldrich,
6
Germany) was used as an oil solution. All aqueous solutions were prepared using
7
deionized water (18.0 MΩ cm. Milli-Q Gradient System, Millipore, Thailand).
8
Phosphate buffer saline (PBS) pH 7.4 at a concentration of 0.1 M was used as a
9
supporting electrolyte for all experiments.
SC
RI PT
1
To prepare 0.1 M PBS, the mixture
comprising of 2.0 g NaCl, 0.05 g KCl, 0.36 g Na2HPO4 and 0.06 g KH2PO4 was
11
dissolved in a 250 mL volumetric flask using deionized water. All aqueous stock
12
standards of 4-AP and PA were prepared in 0.1 M PBS.
M AN U
10
13
2.2 Fabrication of patterned PDMS
15
In this work, solutions were pumped through the device using syringe pumps
16
(Harvard Apparatus PHD 2000, Harvard Apparatus, Holliston, MA). Both aqueous
17
and oil phases were prepared and stored in 1 mL plastic syringes (Nipro, Thailand).
18
Polyethylene tubing (0.38 mm I.D., 1.09 mm O.D., PORTEX, Belgium) connecting
19
the inlets of microfluidic device with syringe pumps was secured using commercial
20
epoxy. For microfluidic experiments, a T-junction microchannel and electrode layout
21
originally published by Liu et al. was used [47].
22
photoresist was coated onto a silicon wafer using a spin coater and then baked at 95 oC
23
for 45 min. Next, the transparency film containing the microchannel and electrode
24
pattern was placed over the coated wafer, and exposed to ultra-violet (UV) light for
25
pattern. The final SU-8 template was obtained by washing with the SU-8 developer
AC C
EP
TE D
14
Briefly, the SU-8 negative
ACCEPTED MANUSCRIPT and isopropanol, respectively.
Microchannel platforms were fabricated using the
2
traditional soft lithography using a 10:1 ratio of the PDMS precursor to curing agent
3
(Sylgard 184, Dow Corning) [48-49]. The mixture was degassed under vacuum to
4
remove dissolved air. The PDMS mixture was poured onto the SU-8 master and
5
baked in the oven at 65 oC for 3 hrs. The cross-linked PDMS was peeled off the mold,
6
and inlets were created using a circular biopsy puncher.
7
containing the microchannel layer and the electrode layer were obtained. The depth of
8
all microchannels was 100 µm. For upper PDMS layer, the main channel of 500 µm
9
width (having two inlets and one outlet) was narrowed to be a confined channel (50
RI PT
1
SC
Two PDMS replicas
µm width and 1 cm length).
11
channels (100 µm depth and 500 µm width) with a spacing between each electrode of
12
500 µm were used according to previous reports [48, 50].
13
For lower electrode layer, three parallel electrode
M AN U
10
2.3 Fabrication and modification of electrode
15
Electrode fabrication was accomplished in two steps, screen-printing of the
16
carbon-paste electrode and electrode modification using G-PANI nanocomposite.
17
PDMS cross-linked carbon paste electrodes (CPEs) were created using the previously
18
published method from Sameenoi et al. [48, 50]. Briefly, a carbon paste containing
19
graphite powder, mineral oil, and PDMS mixture in a ratio of 2:1:1 was spread over
20
the electrode channels in the PDMS. Excess paste was removed using Scotch Magic
21
TapeTM until well-defined carbon paste electrodes were obtained.
AC C
EP
TE D
14
22
For electrode modification, G-PANI nanocomposite was prepared using a
23
simple physical mixing procedure [40]. G in NMP solution (2 mg mL-1) was prepared
24
and dispersed using an ultrasonic bath for 12 hrs at room temperature. The conductive
25
form of PANI was prepared by doping with camphor-10-sulfonic acid and dissolved in
ACCEPTED MANUSCRIPT chloroform. Then, the G and PANI solutions were mixed and sonicated for 12 hrs to
2
obtain a well-dispersed G-PANI nanocomposite solution. Next, 1 µL-aliquot of G-
3
PANI nanocomposite was casted onto the surface area of a carbon-paste working
4
electrode. The modified CPE was baked in the oven at 65 oC in order to evaporate
5
NMP solution. The morphology of G-PANI nanocomposite was observed using a
6
JEM-2100 transmission electron microscope (Japan Electron Optics Laboratory Co.,
7
Ltd, Japan).
8
second PDMS layer (containing 10 mm diameter hole or T-junction microchannel)
9
was sealed over PDMS layer containing G-PANI/CPE using reversible ethanol
10
bonding method. Ethanol was dropped onto both PDMS surfaces, the surfaces were
11
then carefully aligned before being baked at 65°C for 1 hour in order to evaporate the
12
NMP within the casted modifier layer. Electrical connections were made using wires
13
glued to the electrodes using silver paste (SPI supplies, West Chester, PA) and epoxy.
14
The actual working electrode area for the batch system was 5 mm2 while droplet
15
system was 0.025 mm2 (due to the confined channel). Examples of microfluidic and
16
batch devices are shown in the Fig.1b.
19
SC
M AN U
TE D
EP
18
For electrochemical detection in batch and droplet-based systems, a
2.4 Electrochemical detection using G-PANI modified CPE
AC C
17
RI PT
1
Electrochemical measurements including cyclic voltammetry, square-wave
20
voltammetry, and chronoamperometry were performed using a commercially available
21
potentiostat (eDAQ, ED410, 410-088, Australia) using standard three-electrode
22
configuration. The working electrode was either a bare CPE or G-PANI/CPE. Both
23
pseudo-reference and auxiliary electrodes were CPEs. Cyclic voltammetry was used
24
to compare electrochemical performance of each working electrode type using the
ACCEPTED MANUSCRIPT 1
working potential ranges of -0.60 to +0.60 V and -0.20 to +1.00 V vs. CPE for
2
ferri/ferrocyanode and 4-AP, respectively.
3
To study mass transfer of 4-AP on G-PANI/CPE, the dependence of scan rates
4
was performed in the range of 0.01-0.20 V s-1.
5
simultaneously, square-wave voltammetry with a potential range of –0.20 to +1.00 V
6
vs. CPE was used. Voltammograms were recorded in the positive sweep direction to
7
observe the anodic responses of both 4-AP and PA. All electrochemical experiments
8
were carried out at room temperature.
SC
RI PT
To measure 4-AP and PA
10
TE D
M AN U
9
Fig. 1 (a) Schematic of microchannels (top) and electrode patterns (bottom). (b) An
12
electrochemical batch cell (left) and a microfluidic device comprising of main channel and
13
confined channel coupled with microband electrodes (WE-working electrode, CE-counter
14
electrode, and RE-reference electrode).
AC C
15
EP
11
16
2.5 Chronoamperometric determination of 4-AP
17
For microfluidic system, droplets were generated using an oil carrier phase
18
(perfluorodecalin and 1H, 1H, 2H, 2H-perfluoro-1-octanol at a ratio of 10:2 (v/v) and
ACCEPTED MANUSCRIPT an aqueous testing solution. Chronoamperometric detection was performed for the
2
detection of 4-AP in the droplets. The oil phase flow rate was 1.8 µL min-1 while the
3
aqueous phase flow rate was 0.8 µL min-1. The water fraction (Wf) was calculated
4
from following equation [51]. Wf = Fw/(Fw + Fo)
5
7
(1)
where Wf is the water fration, Fw is aqueous- phase flow rate, and Fo is the aqueous- and oil-phase flow rates, respectively.
SC
6
RI PT
1
8
Here, the total flow rate was 2.6 µL min-1, corresponding to a linear flow
10
velocity of 0.86 mm s-1 and a water fraction of 0.31. Chronoamperometric responses
11
from droplet contents were measured while droplets passing through the three-
12
electrode system. Data was collected for 1 min and averaged currents were plotted
13
versus detection potential (Edet) to generate hydrodynamic voltammograms (HDVs) in
14
the range of 0.00–0.40 V vs. CPE.
15
detection potential as defined by the highest signal-to-noise ratio (S/N). The limits of
16
detection (LOD) and quantitation (LOQ) were obtained from LOD = 3(SDbl/S) and
17
LOQ = 10(SDbl/S), respectively, where SDbl is the standard deviation of the blank
18
measurement (n = 10) and S is the slope of the linear calibration. Finally, our method
19
was applied for 4-AP determination in PA liquid samples. Prior to analysis, the PA
20
liquid samples was diluted using 0.1 M PBS pH 7.4. The 4-AP concentration levels in
21
all samples were determined and compared with those obtained for the standard
22
CZE/UV-Vis method [52].
TE D
M AN U
9
AC C
EP
HDVs were used to determine the optimal
23
CZE separation was performed using a MDQ automated CE system coupled
24
with a diode array detector (Beckman), fluid-cooled column cartridge and automatic
ACCEPTED MANUSCRIPT injector [11]. A fused-silica capillary column of 57 cm (50 cm length to detector) × 75
2
µm i.d. and 375 µm o.d. was used. For each CE run, the capillary column was first
3
rinsed with 0.1 M sodium hydroxide for 1 min at high pressure (20 psi), followed by
4
rinsing with the running buffer (50 mM borate buffer pH 9.2) for 1 min. Samples
5
were hydrodynamically injected for 10 s and a voltage of +20 kV was applied for
6
separation. UV absorption was monitored at 250 nm.
7
SC
3. RESULTS AND DISCUSSION
3.1 Morphology and electrochemical characterization and of G-PANI/CPE.
9
M AN U
8
RI PT
1
10
Various reports have used G-PANI nanocomposites to improve the
11
electrochemical sensitivity of carbon electrodes with the resulting performance
12
improvement being attributed to the increase in electrode surface area [3, 5, 37, 39-
13
46].
14
microscopy (TEM) was used to characterize G-PANI nanocomposite (Fig.2a). The
15
TEM images clearly show a well dispersion of G with slight agglomeration; moreover,
16
the electron diffraction pattern of G sheet (the inset of Fig. 2a) is matched with the
17
previous published report [42].
EP
TE D
To observe the changes of electrode morphology, transmission electron
Next, cyclic voltammetry of standard ferri/ferrocyanide redox species was used
19
to characterize the electrochemical properties of the bare CPE, PANI/CPE, and G-
20
PANI/CPE electrodes (Fig. 2b).
21
PANI/CPE exhibited well-defined anodic and cathodic ferri/ferrocyanide current
22
responses which were 10-fold higher than those obtained from the bare CPE and 3-
23
fold greater than those of PANI/CPE and G/CPE. Moreover, peak potential separation
24
between anodic and cathodic peaks was noticeably reduced when using G-PANI/CPE
25
compared to those measured from the PANI/CPE and bare CPE, indicating that the G-
AC C
18
Compared to the PANI/CPE and bare CPE, G-
ACCEPTED MANUSCRIPT 1
PANI nanocomposite can be also used as an electrode modifier to improve the electron
2
transfer kinetics.
AC C
4
EP
TE D
M AN U
SC
RI PT
3
5
Fig. 2 SEM images of (a) bare SPCE, (b) G-PANI/SPCE, (c) A TEM image of G-PANI
6
nanocomposite with an electron diffraction pattern of G (the inset of Fig.2c) and (d) cyclic
7
voltammograms of 1 mM ferri/ferrocyanide in 0.1 M KCl at bare CPE (black line),
8
PANI/CPE (green line), G/CPE (yellow line) and G-PANI/CPE (red line).
9 10
ACCEPTED MANUSCRIPT 3.2 Electrochemical detection of 4-AP and PA using G-PANI/CPE.
2
Next, the electrochemical behavior of 4-AP and PA using the G-PANI/CPE in
3
the batch cell was investigated using cyclic voltammetry with the comparison between
4
the G-PANI/CPE and bare CPE, which is shown in Fig. 3a. Cyclic voltammograms of
5
the G-PANI/CPE exhibited quasi-reversible redox peaks with significantly increased
6
redox current (2-fold) and reduced redox potentials (~100 mV) when compared to bare
7
CPE.
8
nanocomposite towards 4-AP, demonstrating that the nanomodifier offers improved
9
sensitivity for 4-AP, compared to the unmodified CPE.
RI PT
1
SC
These results can be ascribed to good electrocatalytic activity of G-PANI
M AN U
Therefore, the G-PANI
10
nanocomposite can be used as an excellent electrode modifier in the electrochemical
11
system.
To study the mass transfer process of 4-AP on the G-PANI/CPE surface, a current
13
dependence on scan rate was performed (Fig. 3b and c). A slight shift of both anodic
14
and cathodic peak potentials was observed owing to the adsorption of 4-AP on the
15
electrode surface. Both anodic (ip,a) and cathodic (ip,c) peak currents increased linearly
16
with the square root of scan rate (ν1/2) with correlation coefficients (R2) over 0.99.
17
These results verify that the redox process was controlled by diffusion of 4-AP
18
corresponding to the Randles-Sevcik equation (equation 1).
20
EP
AC C
19
TE D
12
ip = 2.686 × 105 n3/2 A C D1/2 ν1/2
(2)
where ip is the peak current of 4-AP in A, n is the number of electrons involved
21
(to reduce/oxidize one molecule of 4-AP), A is the electrode area in cm2, D is the
22
diffusion coefficient of 4-AP in cm2 s-1, C is the concentration of 4-AP in mol cm-3,
23
and ν1/2 is the scan rate in V s-1.
24
2
EP
1
TE D
M AN U
SC
RI PT
ACCEPTED MANUSCRIPT
Fig. 3 (a) Comparison of cyclic voltammograms of 1 mM 4-AP obtained from the G-
4
PANI/CPE and bare CPE at a scan rate of 0.1 V/s, (b) cyclic voltammograms of 1 mM
5
4-AP at the G-PANI/CPE with various scan rates in the range of 0.01-0.2 V/s, (c) peak
6
currents of 4-AP as a function of the square root scan rate (ν1/2), and (d) square-wave
7
voltammograms of 4-AP and PA (0-0.2 mM) at the G-PANI/CPE with the scanning
8
potential range of -0.2 to 0.8 V vs. CPE.
9
AC C
3
ACCEPTED MANUSCRIPT Subsequently, square-wave voltammetry was used to determine detection limits
2
and linearity. Fig. 3d displays representative square-wave voltammograms of 4-AP
3
and PA at concentrations between 50 and 200 µM. For the response from both 4-AP
4
and PA, anodic peak currents are linearly proportional to their concentrations with an
5
LOD of 4.33 µM and 2.12 µM for 4-AP and PA, respectively. The peak potential
6
separation between 4-AP and PA is clearly observed with an anodic potential
7
difference (EPA-E4-AP) of 380 mV. As a result, the selection of potential to use in
8
further chronoamperometric experiments would be particularly useful for selective
9
electrochemical detection of 4-AP in the presence of PA.
SC
RI PT
1
M AN U
10
3.3 Chronoamperometric detection in droplets
12
Chronoamperometric detection has been broadly used in the various flow-based
13
systems due to its ease of operation and low background current. Fig. 4 shows a
14
representative chronoamperogram of 300 µM 4-AP in droplets in which each discrete
15
peak corresponds to an individual droplet. When the droplet front began to pass
16
through the electrode array, the current increased sharply. With the electrooxidation
17
reaction of 4-AP proceeded, its concentration region at the nearby electrode surface
18
exponentially decreased, resulting that the current slowly decayed with time
19
corresponding to Cottrell equation (equation 2). Subsequently, the current approaches
20
a steady state level of 5.14±0.11 nA (n=10) which can be assigned to the diffusion-
21
limited current of 4-AP. For quantification, the current was measured during this
22
regime.
AC C
EP
TE D
11
M AN U
SC
RI PT
ACCEPTED MANUSCRIPT
TE D
1
Fig. 4 (a) A chronoamperogram of droplets containing 0.3 mM 4-AP in 0.1 M PBS pH
3
7.4. The optimal conditions: a detection potential (Edet) of +0.2 V vs. CPE, a total flow
4
rate of 2.6 µL min-1 (0.016 mm s-1) and Wf = 0.31.
6 7
AC C
5
EP
2
3.3.1 Selection of the optimal detection potential (Edet).
Selective detection of 4-AP in the presence of PA in the flow-based system was
8
assessed. According to Fig. 3d, the selection of Edet lower than +0.3 V vs. CPE should
9
achieve selective detection of 4-AP in the presence of PA. To select an optimal Edet
10
for chronoamperometric detection of 4-AP and PA in the droplet-based flow system,
11
hydrodynamic voltammetry (Fig. 5a) experiments were conducted. The anodic peak
12
current of 4-AP increased with Edet.
There is no signal response from PA and
ACCEPTED MANUSCRIPT 1
background (BG) solution (0.1 M PBS pH 7.4) in the range of 0.0-0.2 V vs. CPE
2
while both anodic current signals of 300 µM PA and BG solution also increased with
3
Edet over +0.2 V vs. CPE.
4
Thus, the Edet for chronoamperometric detection in the range between 0.0-0.2 V
6
vs. CPE can be used for selective detection of 4-AP without an interfering response
7
from PA. To optimize the Edet for chronoamperometric detection of droplet contents,
8
the signal-to-background (S/B) ratio of 4-AP and PA was plotted as a function of Edet.
9
As seen from Fig. 5b, an Edet of +0.2 V vs. CPE showed the highest S/B ratio for 4-AP
10
detection;
+0.2
11
chronoamperometric Edet for quantitative measurements of 4-AP for further
12
experiment.
vs.
CPE
was
chosen
as
the
optimal
AC C
EP
TE D
13
V
M AN U
accordingly,
SC
RI PT
5
14 15 16
Fig. 5 (a) Hydrodynamic voltammogram and (b) signal to background ratio of 0.3 mM 4-AP
17
and 0.3 mM PA. The measurements were carried out using a total flow rate of 2.6 µL min-1
18
(0.016 mm s-1) and Wf = 0.31.
ACCEPTED MANUSCRIPT 1
3.3.2 Effect of water fraction and total flow rate The influence of water fraction (Wf) and total flow rate on chronoamperometric
3
measurements were thenstudied. Wf is a well-known factor strongly affecting droplet
4
size with droplet size increasing with Wf. In this work, the droplet sizes at Wf values in
5
the range of 0.15-0.46 were generated by adjusting the flow rate ratio between oil and
6
aqueous solutions while the total flow rate was kept constant at 2.6 µL min-1. As
7
shown in Fig. 6a, when the water fraction was lower than 0.31, unstable droplets with
8
small sizes were produced, resulting in low anodic current. For Wf values over 0.38,
9
droplet length was too long, resulting that the anodic steady-state current decreased
10
due to amperometrically exponential decay. The highest current was obtained at a
11
water fraction of 0.31. Accordingly, the water fraction of 0.31 was found to be the
12
optimal Wf to produce stable droplets and all subsequent experiments were performed
13
using this conditions.
M AN U
SC
RI PT
2
AC C
EP
TE D
14
15 16
Fig. 6 Effects of (a) total flow rate and (b) water fraction on chronoamperometric
17
detection of 0.3 mM 4-AP. Conditions: an detection potential (Edet) of +0.2 V vs. CPE,
18
total flow rate of 2.6 µL min-1 (0.016 mm s-1) and Wf = 0.31.
ACCEPTED MANUSCRIPT 1
Another important factor influencing on chronoampermetric response is total
2
flow rate. The effect of total flow rate was investigated as shown in Fig. 6b. While the
3
water fraction was kept at a constant of 0.31, total flow rate was varied between 1.30-
4
3.90 µL min-1, corresponding to a linear flow velocity in the range of 0.43-1.29 mm s-
5
1
6
steady-state current was obtained due to the long residence time of a single droplet
7
passing over the electrode surface. When the total flow rate was >3.25 µL min-1
8
(linear velocity > 1.08 mm/s), the current also reduced significantly. We believe that
9
this high total flow rates provided short residence time which was not sufficient for the
SC
RI PT
. Results show that for flow rates <2.6 µL min-1 (linear velocity < 0.43 mm/s), a low
electrochemical process to occur.
11
obtained from the total flow rates at 2.6 and 3.25 µL min-1. In addition, use of high
12
flow rates to produce droplets increases reagent/sample consumption. Therefore, an
13
optimal total flow rate of 2.6 µL min-1 (linear velocity = 0.86 mm s-1) was selected to
14
use in further experiments.
TE D
15
The highest steady-state current values were
M AN U
10
3.4 Analytical performance.
17
The analytical performance of the droplet microfluidics coupled with G-
18
PANI/CPE was investigated. Chronoamperometric detection of 4-AP at Edet of +0.2 V
19
vs. CPE was performed using the optimal conditions as mentioned above. Calibration
20
curve of 4-AP was plotted between anodic current as a function of the standard 4-AP
21
concentration as shown in Fig. 7. A linear range was found to be 50-500 µM with
22
correlation coefficient (R2) of 0.998. The limit of detection (LOD, S/N=3) was found
23
to be 15.68 µM while limit of quantitation (LOQ, S/N=10) was found to be 52.28 µM.
24
The European, United States, British, German, and Chinese Pharmacopoeias report the
25
maximum allowable limit of 4-AP in PA products is 50 ppm (0.005% w/w); therefore,
AC C
EP
16
ACCEPTED MANUSCRIPT 1
our system can determine 4-AP at the relevant concentration in commercial PA
2
samples.
TE D
M AN U
SC
RI PT
3
4
Fig. 7 A linear calibration plot of 4-AP in the concentration range of 0-500 µM. The optimal
6
conditions: an detection potential (Edet) of +0.2 V vs. CPE, total flow rate of 2.6 µL min-1
7
(0.016 mm s-1) and Wf = 0.31. (Inset) A chronoamperogram of 4-AP current vs. time.
9
AC C
8
EP
5
In this work, a chronoamperometric measurement within droplet volume of
10
0.625 nL was performed.
This volume of testing solution was lower than those
11
required from conventional electrochemical batch cells (normally require sample
12
volumes at least 0.5 mL), corresponding to a high limit of detection of our proposed
13
system.
Although the LOD and LOQ values reported here are higher than those
ACCEPTED MANUSCRIPT 1
obtained from the previous publications [2-3, 5, 7, 10], our approach offers simplicity
2
and inexpensive operation.
3
sample/reagent was required to operate the droplet generation within the microfluidic
4
system, leading to a fast and high-throughput analysis of 4-AP.
In addition, small aliquot (<1 mL) of testing
In addition to assess the stability of this system, chronoamperometric detection
6
of standard 4-AP at different concentrations by 20 successive measurements was
7
performed for intra-day and inter-day precisions as shown in the Fig.8. For intra-day
8
and inter-day results, relative standard deviations (RSDs) were found to be less than
9
5% (n = 20). Therefore, these results verify that our proposed system had the good
10
stability. Moreover, the reproducibility of the microfluidic sensor was evaluated using
11
chronoamperometric detection of 0.3 mM 4-AP. The %RSD of seven different devices
12
was found to be 3.5%, indicating that the fabricated microfluidic sensor had a good
13
precision.
M AN U
SC
RI PT
5
15
AC C
EP
TE D
14
16
Fig. 8 Intra-day measurements of (a) 4-AP at concentrations of 0.1, 0.2 and 0.3 mM and (b)
17
Inter-day measurements of 0.1 and 0.3 mM 4-AP for three days (n = 3).
18
ACCEPTED MANUSCRIPT 3.5 Interference study and Determination of 4-AP in commercial PA samples.
2
The effect of various foreign species on the detection of 0.3 mM 4-AP was
3
studied. The 5% tolerable ratio of foreign species is shown in Table 1. The tolerable
4
ratio was defined as the level of foreign species, generating a change in intensity of the
5
peak current of ±5%. From the results, these species were tolerated at a high level,
6
demonstrating the good selectivity of the proposed method.
RI PT
1
Additionally, since 4-AP is produced from the degradation of pharmaceutical
8
PA samples, the selectivity of this method towards the determination of 4-AP in the
9
presence of PA in commercial samples was evaluated. The tolerance concentration is
10
defined as the concentration of 4-AP, generating a change in signal response of ±5%.
11
Results show that 5000 µM PA gave a 5% change in the detection of 50 µM 4-AP;
12
therefore, the PA sample was diluted to a lower concentration. Next, the application
13
of our method was tested by measuring the spiked 4-AP concentrations (100, 200, 300,
14
400, and 500 µM) in each diluted PA sample.
M AN U
Table 1 Effect of foreign ions on the determination of 0.3 mM 4-AP
EP
16
TE D
15
SC
7
5% tolerable
AC C
Foreign species
17
molar ratio
Na+,K+,Mg2+, Ca2+, NO3-, SO42-, PO43-, Cl- ,Glucose, Sucrose
>10000
Cu2+, Fe2+, Fe3+
300
Acetylsalicilic acid, Glutathione
1000
Uric acid, Dopamine
500
Ascorbic acid, Cysteine
200
Paracetamol
100
ACCEPTED MANUSCRIPT As shown in the table 2, the % recovery of this system was found in the range
2
of 91.21%-105.34% (n=20). Moreover, to validate our method, the results obtained
3
from the proposed system was compared to those obtained from the conventional
4
capillary zone electrophoresis/UV-Visible spectrophotometric technique (CZE/UV-
5
Vis) [11] using a paired t-test at 95% confidential interval. The experimental t-values
6
(tcalculated) obtained by this proposed method was found to be -2.20 which were
7
significantly lower than the critical t-values of 1.76. Results show that there is no
8
significant difference between the results obtained from our method and CZE/UV-Vis
9
method. As a result, our electrochemical droplet system is an alternative and high-
10
throughput method (at least 60 samples h-1) for determining the 4-AP contamination in
11
commercial PA formulations.
AC C
EP
TE D
12
M AN U
SC
RI PT
1
ACCEPTED MANUSCRIPT 1
Table 2 The % recovery of the our proposed method (n=20) for determination of 4-AP
2
in PA samples vs. conventional CZE/UV-Vis method (n=3).
3
This proposed method
CZE/UV-Vis method
(n=20)
(n=3)
Sample
concentration %Recovery (µM)
%Recovery
%RSD
2.75
99.74±1.01
1.01
200
91.29±3.29
3.60
102.95±3.29
3.20
300
101.12±4.12
4.07
98.89±2.11
2.13
400
97.34±3.93
4.04
99.19±1.71
1.72
500
101.25±4.19
4.14
101.91±2.41
2.36
100
99.97±3.21
3.21
99.24±1.31
1.32
200
98.08±2.94
3.00
98.93±1.92
1.94
95.25±3.17
3.33
102.25±1.27
1.24
105.34±2.94
2.78
103.04±2.14
2.08
M AN U
®
300
EP 500
91.93±2.74
2.98
99.91±0.24
0.24
100
97.51±3.19
3.27
102.01±2.45
2.40
200
101.12±1.92
1.90
99.92±1.29
1.29
300
102.12±2.25
2.20
101.01±2.01
1.99
400
103.34±1.89
1.83
103.34±1.71
1.65
500
101.25±2.97
2.93
103.15±1.31
1.27
AC C
4 5
SC
91.21±2.51
400
SARA®
(±SD)
100
Infants’
TEMPRA®
%RSD
TE D
(±SD)
TYLENOL
RI PT
Spiked 4-AP
ACCEPTED MANUSCRIPT 1
CONCLUSIONS In this work, we report a novel electrochemical droplet microfluidic device for
3
determination of 4-AP in commercial PA formulations. The G-PANI/CPE was first
4
coupled with the droplet system to perform chronoamperometric detection of 4-AP.
5
The improvement in electrochemical sensitivity was attributed to an enhancement of
6
the active surface area of electrode and increased electrochemical conductivity. Our
7
proposed method can perform a high-throughput and rapid measurement of 4-AP in
8
commercial PA products with required small consumption of reagent/sample.
9
Eventually, this system was successfully applied for the determination of 4-AP in PA
10
liquid samples with high precision and good recovery; therefore, this system might be
11
an alternative analytical device for routine analysis of 4-AP residue in pharmaceutical
12
products.
M AN U
SC
RI PT
2
13
ACKNOWLEDGEMENTS
TE D
14
P. R. wishes to thank the financial support from Chulalongkorn University and
16
the Thailand Research Fund, through the Royal Golden Jubilee Ph.D. Program (Grant
17
No. PHD/0251/2552). Moreover, this research has been supported by the Thailand
18
Research Fund through Research Team Promotion Grant (RTA578005) and National
19
Research University project, Office of Higher Education Commission (WCU-032-
20
AM-57).
AC C
21
EP
15
ACCEPTED MANUSCRIPT 1
REFERENCES
2
[1]
N. Sarkar, Environmental Toxicology and Pharmacology 37 (2014) 438. [2]
L. Y. Shiroma, M. Santhiago, A. L. Gobbi, L. T. Kubota, Analytica Chimica Acta 725 (2012) 44.
5
RI PT
3 4
K. Vijayakaran, K. Kannan, M. Kesavan, S. Suresh, P. Sankar, S. K. Tandan, S.
[3]
H. Yin, Q. Ma, Y. Zhou, S. Ai, L. Zhu, Electrochimica Acta 55 (2010) 7102.
7
[4]
M. S. Bloomfield, Talanta 58 (2002) 1301.
8
[5]
Y. Fan, J.-H. Liu, C.-P. Yang, M. Yu, P. Liu, Sensors and Actuators B: Chemical 157 (2011) 669.
[6]
A. Brega, P. Prandini, C. Amaglio, E. Pafumi, Journal of Chromatography A
M AN U
9 10
SC
6
535 (1990) 311.
11
[7]
C.-M. Zou, H. Yu, M.-Y. Wang, Chinese Chemical Letters 25 (2014) 201.
13
[8]
B. Schultz, Journal of Chromatography A 299 (1984) 484.
14
[9]
B. C. Lourenção, R. A. Medeiros, R. C. Rocha-Filho, L. H. Mazo, O. Fatibello-
TE D
12
Filho, Talanta 78 (2009) 748.
15
[10]
Q. Chu, L. Jiang, X. Tian, J. Ye, Analytica Chimica Acta 606 (2008) 246.
17
[11]
T. Pérez-Ruiz, C. Martínez-Lozano, V. Tomás, R. Galera, Journal of
[12]
21
[13]
22
[14]
Y. Zhu, Q. Fang, Analytica Chimica Acta 787 (2013) 24. C.-G. Yang, Z.-R. Xu, J.-H. Wang, TrAC Trends in Analytical Chemistry 29
(2010) 141.
23
25
A. B. Vishnikin, M. K. E. A. Al-Shwaiyat, G. A. Petrushina, L. P. Tsiganok, V.
Andruch, Y. R. Bazel, H. Sklenářová, P. Solich, Talanta 96 (2012) 230.
20
24
AC C
Pharmaceutical and Biomedical Analysis 38 (2005) 87.
18 19
EP
16
[15]
S. Park, Y. Zhang, S. Lin, T.-H. Wang, S. Yang, Biotechnology Advances 29 (2011) 830.
ACCEPTED MANUSCRIPT 1
[16]
Chemical 180 (2013) 21.
2 3
B. Ramaswamy, Y.-T. T. Yeh, S.-Y. Zheng, Sensors and Actuators B:
[17]
Y. T. Atalay, S. Vermeir, D. Witters, N. Vergauwe, B. Verbruggen, P. Verboven, B. M. Nicolaï, J. Lammertyn, Trends in Food Science & Technology
5
22 (2011) 386.
6
[18]
RI PT
4
M. Safavieh, S. Nahar, M. Zourob, M. U. Ahmed, in High Throughput Screening for Food Safety Assessment (Eds.: A. K. Bhunia, M. S. Kim, C. R.
8
Taitt), Woodhead Publishing, 2015, pp. 327. [19]
Z.-X. Guo, Q. Zeng, M. Zhang, L.-Y. Hong, Y.-F. Zhao, W. Liu, S.-S. Guo, X.Z. Zhao, Sensors and Actuators A: Physical 172 (2011) 546.
10
M AN U
9
SC
7
11
[20]
S. Teychené, B. Biscans, Chemical Engineering Science 77 (2012) 242.
12
[21]
M.-P. N. Bui, C. A. Li, K. N. Han, J. Choo, E. K. Lee, G. H. Seong, Analytical Chemistry 83 (2011) 1603.
14
[22]
H. Tsuchiya, M. Okochi, N. Nagao, M. Shikida, H. Honda, Sensors and
TE D
13
Actuators B: Chemical 130 (2008) 583.
15
[23]
J. Ji, Y. Zhao, L. Guo, B. Liu, C. Ji, P. Yang, Lab on a Chip 12 (2012) 1373.
17
[24]
I. Lignos, L. Protesescu, S. Stavrakis, L. Piveteau, M. J. Speirs, M. A. Loi, M.
[25]
[26]
24
S.-W. Lin, C.-H. Chang, C.-H. Lin, Genomic Medicine, Biomarkers, and
Health Sciences 3 (2011) 27.
22 23
T. Konry, M. Dominguez-Villar, C. Baecher-Allan, D. A. Hafler, M. L.
Yarmush, Biosensors and Bioelectronics 26 (2011) 2707.
20 21
AC C
V. Kovalenko, A. J. deMello, Chemistry of Materials 26 (2014) 2975.
18 19
EP
16
[27]
J. Lee, H. K. Musyimi, S. A. Soper, K. K. Murray, Journal of the American Society for Mass Spectrometry 19 (2008) 964.
ACCEPTED MANUSCRIPT [28]
Edel, Analytical Chemistry 83 (2011) 3076.
2 3
[29]
G. Aubry, S. Méance, L. Couraud, A. M. Haghiri-Gosnet, Q. Kou, Microelectronic Engineering 86 (2009) 1368.
4 5
M. P. Cecchini, J. Hong, C. Lim, J. Choo, T. Albrecht, A. J. deMello, J. B.
[30]
J. Clausell-Tormos, D. Lieber, J.-C. Baret, A. El-Harrak, O. J. Miller, L. Frenz,
RI PT
1
6
J. Blouwolff, K. J. Humphry, S. Köster, H. Duan, C. Holtze, D. A. Weitz, A. D.
7
Griffiths, C. A. Merten, Chemistry & Biology 15 (2008) 427. [31]
J. Wang, Talanta 56 (2002) 223.
9
[32]
S. Liu, Y. Gu, R. B. Le Roux, S. M. Matthews, D. Bratton, K. Yunus, A. C.
SC
8
M AN U
Fisher, W. T. S. Huck, Lab on a Chip 8 (2008) 1937.
10 11
[33]
Z. Han, W. Li, Y. Huang, B. Zheng, Analytical Chemistry 81 (2009) 5840.
12
[34]
S. Gu, Y. Lu, Y. Ding, L. Li, H. Song, J. Wang, Q. Wu, Biosensors and Bioelectronics 55 (2014) 106.
[35]
Actuators B: Chemical 171–172 (2012) 619.
15
[36]
Acta 690 (2011) 10.
17 18
[37]
M. Arvand, T. M. Gholizadeh, Colloids and Surfaces B: Biointerfaces 103 (2013) 84.
19 20
W. Siangproh, W. Dungchai, P. Rattanarat, O. Chailapakul, Analytica Chimica
EP
16
D. Itoh, F. Sassa, T. Nishi, Y. Kani, M. Murata, H. Suzuki, Sensors and
AC C
14
TE D
13
[38]
H. Ghadimi, R. M.A.Tehrani, A. S. M. Ali, N. Mohamed, S. Ab Ghani,
Analytica Chimica Acta 765 (2013) 70.
21 22
[39]
S. Wu, Q. He, C. Tan, Y. Wang, H. Zhang, Small 9 (2013) 1160.
23
[40]
N.
24
Thammasoontaree,
P.
Rattanarat,
N.
Ruecha,
Rodthongkum, O. Chailapakul, Talanta 123 (2014) 115.
W.
Siangproh,
N.
ACCEPTED MANUSCRIPT [41]
Analytica Chimica Acta 804 (2013) 84.
2
[42]
Bioelectronics 52 (2014) 13. [43]
(2013) 240.
6 7
[44]
[45]
J. Li, S. Liu, J. Yu, W. Lian, M. Cui, W. Xu, J. Huang, Sensors and Actuators B: Chemical 188 (2013) 99.
10 11
E. Asadian, S. Shahrokhian, A. I. zad, E. Jokar, Sensors and Actuators B: Chemical 196 (2014) 582.
8 9
Y.-P. Dong, J. Zhang, Y. Ding, X.-F. Chu, J. Chen, Electrochimica Acta 91
RI PT
4 5
N. Ruecha, R. Rangkupan, N. Rodthongkum, O. Chailapakul, Biosensors and
[46]
SC
3
N. Rodthongkum, N. Ruecha, R. Rangkupan, R. W. Vachet, O. Chailapakul,
M AN U
1
J. Huang, Q. Lin, X. Zhang, X. He, X. Xing, W. Lian, M. Zuo, Q. Zhang, Food Research International 44 (2011) 92.
12
[47]
H. Liu, R. M. Crooks, Lab on a Chip 13 (2013) 1364.
14
[48]
Y. Sameenoi, M. M. Mensack, K. Boonsong, R. Ewing, W. Dungchai, O.
TE D
13
Chailapakul, D. M. Cropek, C. S. Henry, Analyst 136 (2011) 3177.
15
[49]
N. Ruecha, W. Siangproh, O. Chailapakul, Talanta 84 (2011) 1323.
17
[50]
A. Suea-Ngam, P. Rattanarat, O. Chailapakul, M. Srisa-Art, Analytica Chimica
19
[51]
20
[52]
21
22 23
AC C
Acta.
18
EP
16
J. D. Tice, A. D. Lyon, R. F. Ismagilov, Analytica Chimica Acta 507 (2004) 73. T. Németh, P. Jankovics, J. Németh-Palotás, H. Kőszegi-Szalai, Journal of
Pharmaceutical and Biomedical Analysis 47 (2008) 746.
ACCEPTED MANUSCRIPT
RESEARCH HIGHLIGHTS •
A novel combination of G-PANI/CPE and droplet-based microfluidic device for determination of 4-AP was achieved. G-PANI nanocomposite increases the surface area and improved electrochemical sensitivity of the electrode.
EP
TE D
M AN U
monitoring in commercial PA samples.
SC
This novel droplet-based system was successfully applied for 4-AP
AC C
•
RI PT
•