Improving radiotherapy through medical physics developments

Improving radiotherapy through medical physics developments

Radiotherapy and Oncology 117 (2015) 403–406 Contents lists available at ScienceDirect Radiotherapy and Oncology journal homepage: www.thegreenjourn...

329KB Sizes 11 Downloads 93 Views

Radiotherapy and Oncology 117 (2015) 403–406

Contents lists available at ScienceDirect

Radiotherapy and Oncology journal homepage: www.thegreenjournal.com

Editorial

Improving radiotherapy through medical physics developments Ludvig P. Muren a,⇑, Nuria Jornet b, Dietmar Georg c, Robin Garcia d, David I. Thwaites e a Dept of Medical Physics, Aarhus University/Aarhus University Hospital, Aarhus, Denmark; b Servei de Radiofísica i Radioprotecció, Hospital Sant Pau, Barcelona, Spain; c Dept of Radiation Oncology, Division of Medical Radiation Physics, Medical University of Vienna/AKH Vienna, Vienna, Austria; d Medical Physics, Institut Sainte Catherine, Avignon, France; and e Institute of Medical Physics, School of Physics, University of Sydney, Sydney, Australia

This issue contains a handful of highlight medical physics contributions that were presented at the 3rd ESTRO Forum held recently in Barcelona. This tradition was established over recent ESTRO Biennial Physics Conferences (now part of the wider ESTRO Forum conferences), with the highlight papers being published in Radiotherapy & Oncology [1–4]. As for the previous conference selections [5–18], the papers present new and significant findings in some of the many areas where medical physics research and development is essential to improve radiotherapy (RT) planning and delivery, and ultimately outcomes.

Quality assurance in RT – a core medical physics contribution Quality assurance (QA) continues to be at the core of medical physicists’ work (as also reflected in the number of QA-related abstracts submitted to the 3rd ESTRO Forum). It is an essential component for safe, high quality treatments. Results from clinical trials show that poor quality correlates with poor treatment outcomes [19–21]. In parallel with the continuing introduction and development of novel and increasingly complex techniques and technologies, the time needed for QA and dosimetry has increased [2]. Clinical medical physicists necessarily spend a great deal of time on routine QA duties, with potential impact on the time available for other relevant areas such as clinical dosimetry, development and implementation of new techniques, management, and teaching and training [22–23]. Time could be optimised if more of the QA was automated. In the 1950s, automation was seen as a new paradigm that would change society’s way of working, minimising routine tasks and freeing more time for creative and higher level work and providing improved work-life balance and quality of life. Unfortunately, more than half a century after the first publications on automation, its application to QA in RT is still very limited. It is also perceived that some of the proposed quality controls (QCs), metrics and tolerance limits proposed are out-dated by RT technology advances or insufficiently effective to detect at least some errors that may have a clinical impact [24–27]. When new technology is being implemented, it is crucial to understand how

⇑ Corresponding author at: Dept of Medical Physics, Aarhus University Hospital, Nørrebrogade 44 – Building 5, DK-8000 Aarhus C, Denmark. E-mail address: [email protected] (L.P. Muren). http://dx.doi.org/10.1016/j.radonc.2015.11.008 0167-8140/Ó 2015 Elsevier Ireland Ltd. All rights reserved.

systems and, in particular, treatment units behave in order to identify failure modes and design quality controls capable of detecting any delivery error. Our principal aim is to ensure the patient receives the dose distribution as planned, and if significant differences are found, these should be reported and if possible re-addressed before the end of the treatment. We also need to widen the scope of the assessment of the results of our QC tests and the decisions taken on their basis, moving from a binary evaluation (pass or fail) to an evaluation of trends (temporary or systematic) using groups of data, applying approaches such as Statistical Process Control [28]. In short, there is a clear need for innovative, efficient and effective QA methods with potential for automation. We have now reached a crossroads where we have to consider whether the original QA paradigms remain appropriate for the new technologies, techniques, priorities and resource availability. Routine implementation of beam intensity modulation with dynamic treatment techniques such as intensity-modulated RT (IMRT) and volumetric modulated arc therapy (VMAT) has had a considerable influence on QA procedures. International guidelines [29–31] propose specific QCs to ensure safe and accurate delivery of these techniques. They recommend performing intensive machine-specific QA of dynamic beam delivery and verifications of correct data transfer from the TPS to the treatment unit and limiting pre-treatment measurement QC to a number of plans until sufficient confidence in beam delivery is obtained. However, most European centres still perform pre-treatment verification for each patient long after these techniques are implemented. It seems that we still lack confidence in the capabilities of our treatment units regarding dynamic treatment delivery, or in the alternative verification approaches. This practice may potentially limit the number of patients who can benefit from these techniques. It is also worth noting the results of multi-institutional audits on IMRT and VMAT as they show differences in pre-treatment verification results depending on the equipment and metrics used by the institution [9,32–33]. As no consensus has been reached on discontinuing pre-treatment verification [34], several groups have worked on optimising patient-specific verification focusing on efficiency and effectiveness of the tests and also on evaluation metrics and tolerances [24,35]. Along these lines, the use of treatment unit log files [36–38], detector arrays mounted on the treatment head [39–41] and in vivo portal dosimetry using electronic portal imaging

404

Improving radiotherapy through medical physics developments

devices [42–45] has been proposed to check accurate delivery of dynamic techniques on each fraction. The log file monitoring approach is very attractive as it can be easily automated and does not need any additional equipment. Defenders of log file monitoring argue that it can replace pre-treatment and in vivo dose measurements. Log file analysis, for instance, can verify information transfer integrity and delivery performance for each fraction during patient treatment. Log files can be re-inserted in the TPS and the dose distribution can be re-calculated. Therefore, any difference in the log files can be linked to clinical impact and tolerance thresholds on dose distribution differences could be set. This approach relies on the accuracy of the information on linac parameters as recorded in the log files. It can therefore be an ill-posed problem, relying on the parameters that we want to independently check. In addition, variation in beam profiles, MLC calibration, energy and dose monitor unit equivalence would not be detected by log file analysis. However, coupled with a suitable machine QA programme, log file analysis undoubtedly has a high potential for treatment delivery checking at the machine level [46–49]. Along this line, Pasler et al. show in this issue how log files analysis, after the delivery of a demanding QA plan, can be used for prospective machine QA in dynamic mode [49]. As also stated in their paper, at this stage, log files cannot completely replace in vivo dosimetry or pre-treatment dose measurements as patient variability and beam dosimetry are not checked. Even so, log file analysis is an excellent complement to end-to-end QC tests to trace back any detected error. Managing and adapting for motion in RT – a contemporary medical physics challenge The technical realisation and subsequent clinical implementation of hybrid beam delivery and imaging systems stimulated research and developments to account for intra- and inter-fraction organ motion, including adaptive RT (ART) approaches. Moreover, these topics have become central in contemporary medical physics research and have eclipsed the more traditional fields of dosimetry, quality assurance and treatment planning [7,32,33,45,50–55]. This movement is well reflected in the physics tracks as well as in the interdisciplinary tracks of recent ESTRO meetings. The utilisation of cone beam CT (CBCT) technology on linear accelerators has become the main platform for ART developments [56–58], as demonstrated by Tuomikoski et al. [59] and Heijkoop et al. [60] in this issue. Tuomikoski et al. focused on bladder cancer and explored different plan of the day workflow concepts for ART to overcome inter-fraction effects. Their contribution nicely adds to previous publications on plan of the day ART approaches, which are achievable with today’s state-of-the-art technology as available in many institutions [61–64]. Heijkoop et al. studied the magnitude of intra-fraction motion of the cervix uterus, as well as volume changes of the bladder and rectum, by analysing daily CBCTs. Both studies are representative of the changing use of volumetric imaging, in that CBCT is used beyond setup corrections, moving towards a next level of clinical implementation and utilisation to enable anatomy-based personalised radiation oncology decisions and treatment. Lung cancer is clearly another treatment site that continuously motivated medical physics developments to tackle intra-fraction motion challenges [65–70]. Marker-less tumour tracking and subsequent image registration is key in this context. Dhont et al. present their feasibility study on how the upcoming dual energy X-ray imaging can contribute in this context, although further development and adjustments are still needed to make this a mature technology for everyday clinical use [71].

Outcome modelling to guide RT improvements – a promising medical physics research avenue Although much RT physics research focuses on developing, evaluating and verifying emerging treatment modalities (new photonbased techniques as well as proton and particle therapy), medical physics input is also essential in exploring and understanding outcome data from both earlier as well as present RT techniques [72–75]. Establishing models and their input parameters through analysis of clinical data is an area that is currently receiving increasing attention, for a number of reasons. Technology develops too fast for evidence to be based on (randomised) trials alone [76–80]. At the same time, the input data to our models is increasing in complexity, including predictive/prognostic medical, imaging and molecular factors, with data mining and machine learning methods becoming relevant modelling tools [80–81]. This clearly represents an area where medical physics has an important role to play, cf. the ESTRO Future working group ambitions outlined by Fiorino et al. in the accompanying editorial in the present issue [23]. Two highlight papers on normal tissue outcome modelling that were presented at the 3rd ESTRO Forum are published in respectively the previous [82] and the present [83] issue of the journal. These papers addressed challenges for the key normal tissues in RT of pelvic tumours, the bladder and the rectum. Yahya and colleagues investigated urinary bladder symptoms following RT of a large cohort of (more than 750) patients with prostate cancer [82]. Although there are now several studies published addressing bladder morbidity after RT [84–88], a clear dose response relation has been difficult to establish. Issues such as the large mobility of the organ and the definition of the relevant volume of interest as well as endpoint (e.g. identification of the critical bladder area; bladder- vs. urethra-related symptoms) have probably blurred this relation [89–90]. In their study, Yahya et al. focused on the endpoint definition [82], comparing peak-symptom models with multiple-event and events-counts models [91–92]. They found that including the temporal aspect of the endpoint definitions led to stronger associations between the outcome and the bladder dose surface measures. Surface dose distributions in RT for prostate cancer patients were also the basis for the study of Wortel et al., exploring 2D dose surface maps of the anorectal region [83]. To advance our understanding of normal tissue reactions after RT, there is increasing interest in both imaging of normal tissue function [93–94] and studies such as those considered here [83,87], where differences in the spatial patterns of the dose distributions (e.g. in 2D dose maps as for the unfolded rectum) are compared between patients with vs. without morbidity. In their study, Wortel et al. found considerable differences in the doses received at the cranial and posterior part of the rectum between patients with vs. without morbidity, i.e. at parts of the organ well outside of the high dose area [83]. Further work is needed in this direction, both for the rectum [94] and for other organs, before e.g. spatially defined normal tissue constraints can be established. Overall, much remains to be done in this field, as well-characterised, validated normal tissue dose response relations are still scarce. This is a major challenge for the use of models in RT planning, optimisation and evaluation, including the much-cited Dutch model-based patient selection approach for proton therapy [79]. Medical physics challenges in proton and particle therapy Proton and particle therapy have always been a rich area for medical physics research and technological developments. While these activities mainly took place in dedicated treatment and/or research centres, this situation has already changed and will certainly continue to change in the near future. The reasons are

L.P. Muren et al. / Radiotherapy and Oncology 117 (2015) 403–406

multilayered. The main reasons are the more pronounced interest and investment in proton therapy from the radiation oncology community in general, and the adapted solutions from particle therapy vendors offering now also single room facilities. In other words proton therapy is rapidly becoming a standard treatment option in several large cancer treatment centres besides advanced photon beam therapy and brachytherapy and this availability will increase. Consequently the ‘parallel’ research in photon and particle therapy is likely to discontinue. The upcoming particle therapy research topics will therefore become a more integral part of general medical physics activities, including research. Proton and particle therapy have their own specific challenges, such as dedicated quality assurance and beam delivery verification due to the pronounced effects of density variations on particle range. PET and prompt gamma imaging have been explored for this purpose [95–97]. While PET verification has reached a technological level for clinical exploration [98], prompt gamma imaging is still rather at the developmental level. This might change soon. Janssens et al. presented in their study how advanced the pre-clinical level of prompt gamma imaging for range verification is already making the next step of clinical exploration obvious [99].

Concluding remarks The publications in the present issue clearly indicate that medical physics research and development is a vital area [100] and remains a cornerstone in the further advancement of RT, allowing for safe use of new and individualised techniques and modalities, as well as for a deeper understanding of the clinical outcomes of the treatments of the past. With its highly prolific interdisciplinary meetings and journal, ESTRO continues to provide medical physicists with attractive arenas for scientific exchange and growth.

References [1] Nyström H, Thwaites DI. Physics and high-technology advances in radiotherapy: are they still worth it? Radiother Oncol 2008;86:1–3. [2] Thwaites DI, Verellen D. Vorsprung durch Technik: evolution, implementation, QA and safety of new technology in radiotherapy. Radiother Oncol 2010;94:125–8. [3] Thwaites DI, Malicki J. Physics and technology in ESTRO and in Radiotherapy and Oncology: past, present and into the 4th dimension. Radiother Oncol 2011;100:327–32. [4] Muren LP, Thwaites DI. The on-going quest for treatment precision and conformality in radiotherapy. Radiother Oncol 2013;109:337–41. [5] Verhaegen F, van Hoof S, Granton P. Development and validation of a treatment planning system for small animal radiotherapy: SmART-plan. Radiother Oncol 2013;109:361–6. [6] Cranmer-Sargison G, Charles PH, Trapp JV, Thwaites DI. A methodological approach to reporting corrected small field relative outputs. Radiother Oncol 2013;109:350–5. [7] Lechner W, Palmans H, Sölkner L, Grochowska P, Georg D. Detector comparison for small field output factor measurements in flattening filter free photon beams. Radiother Oncol 2013;109:356–60. [8] Carver A, Gately A, Clements R, Nahum A. Monte Carlo dosimetry for the Papillion P50 contact radiotherapy and IORT device. Radiother Oncol 2013;109:367–9. [9] Hussein M, Rowshanfarzad P, Ebert MA, Nisbet A, Clark CH. A comparison of the gamma index analysis in various commercial IMRT/VMAT QA systems. Radiother Oncol 2013;109:370–6. [10] Boylan C, Aitkenhead A, Rowbottom C, Mackay R. Simulation of realistic linac motion improves the accuracy of a Monte Carlo based VMAT plan QA system. Radiother Oncol 2013;109:377–83. [11] Thörnqvist S, Hysing LB, Zolnay AG, et al. Treatment simulations with a statistical deformable motion model to evaluate margins for multiple targets in radiotherapy for high-risk prostate cancer. Radiother Oncol 2013;109: 344–9. [12] Rizzo G, Scalco E, Fiorino C, Cattaneo GM, Sanguineti G. Texture analysis for the assessment of structural changes in parotid glands induced by radiotherapy. Radiother Oncol 2013;109:384–7. [13] Thor M, Apte A, Deasy JO, et al. Dose/volume–response relations for rectal morbidity using planned and simulated motion-inclusive dose distributions. Radiother Oncol 2013;109:388–93.

405

[14] Schakel T, Hoogduin HM, Terhaard CH, Philippens ME. Diffusion weighted MRI in head-and-neck cancer: geometrical accuracy. Radiother Oncol 2013;109:394–7. [15] Van der Reijden A, van Herk M, Sonke JJ. Motion compensated digital tomosynthesis. Radiother Oncol 2013;109:398–403. [16] Kruis MF, van de Kamer JB, Sonke JJ, Jansen EPM, van Herk M. Registration accuracy and image quality of time averaged mid-position CT scans for liver SBRT. Radiother Oncol 2013;109:404–8. [17] Steiner E, Stock M, Kostresevic B, et al. Imaging dose assessment for IGRT in particle beam therapy. Radiother Oncol 2013;109:409–13. [18] Rank CM, Hünemohr N, Nagel AM, Röthke MC, Jäkel O, Greilich S. MRI-based simulation of treatment plans for ion radiotherapy in the brain region. Radiother Oncol 2013;109:414–8. [19] Peters LJ, O’Sullivan B, Giralt J, et al. Critical impact of radiotherapy protocol compliance and quality in the treatment of advanced head and neck cancer: results from TROG 02.02. J Clin Oncol 2010;28:2996–3001. [20] Weber DC, Tomsej M, Melidis C, Hurkmans CW. QA makes a clinical trial stronger: evidence-based medicine in radiation therapy. Radiother Oncol 2012;105:4–8. [21] Weber DC, Hurkmans CW, Melidis C, et al. Outcome impact and costeffectiveness of quality assurance for radiotherapy planned for the EORTC 22071–24071 prospective study for head and neck cancer. Radiother Oncol 2014;111:393–9. [22] Malicki J. Medical physics in radiotherapy: the importance of preserving clinical responsibilities and expanding the profession’s role in research, education, and quality control. Rep Pract Oncol Radiother 2015;20:161–9. [23] Fiorino C, Muren LP, Clark CH, van Elmpt W, Jornet N. Expanding the scientific role of Medical Physics in Radiotherapy: time to act. Radiother Oncol 2015;117:401–2. [24] Carrasco P, Jornet N, Latorre A, Eudaldo T, Ruiz A, Ribas M. 3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification. Med Phys 2012;39:5040–9. [25] Nelms BE, Zhen H, Tomé WA. Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors. Med Phys 2011;38:1037–44. [26] Zhen H, Nelms BE, Tome WA. Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA. Med Phys 2011;38: 5477–89. [27] Kry SF, Molineu A, Kerns JR, et al. Institutional patient-specific IMRT QA does not predict unacceptable plan delivery. Int J Radiat Oncol Biol Phys 2014;90:1195–201. [28] Pawlicki T, Yoo S, Laurence E, Court LE, et al. Moving from IMRT QA measurements toward independent computer calculations using control charts. Radiother Oncol 1998;89:330–7. [29] Van der Wal W, Wiersma J, Ausma AH, et al. Code of practice for the quality assurance and control for intensity modulated radiotherapy. in: Report 22 of the Netherlands Commission on Radiation Dosimetry; 2013. [30] Mans A, Schuring D, Arends M, et al. NCS Code of practice for the quality assurance and control for volumetric modulated arc therapy. in: Report 24 of the Netherlands Commission on Radiation Dosimetry; 2015. [31] Alber M, Broggi S, De Wagter S, et al. Guidelines for the verification of IMRT. ESTRO Booklet n° 9. Brussels; 2008. [32] Clark CH, Hussein M, Tsang Y, et al. A multi-institutional dosimetry audit of rotational intensity-modulated radiotherapy. Radiother Oncol 2014;113: 272–8. [33] Jornet N, Carrasco P, Beltrán M, et al. Multicentre validation of IMRT pretreatment verification: comparison of in-house and external audit. Radiother Oncol 2014;112:381–8. [34] Smith JC, Dieterich S, Orton CG. Point/Counterpoint: it is still necessary to validate each individual IMRT treatment plan with dosimetric measurements before delivery. Med Phys 2011;38:553–5. [35] Visser R, Wauben DJL, de Groot M, et al. Evaluation of DVH-based treatment plan verification in addition to gamma passing rates for head and neck IMRT. Radiother Oncol 2014;112:389–95. [36] Childress N, Chen Q, Rong Y. Parallel/Opposed: IMRT QA using treatment log files is superior to conventional measurement-based method. J Appl Clin Med Phys 2015;16:5385. [37] Sun B, Rangaraj D, Boddu S, et al. Evaluation of the efficiency and effectiveness of independent dose calculation followed by machine log file analysis against conventional measurement based IMRT QA. J Appl Clin Med Phys 2012;13:3837. [38] Hernandez V, Abella R, Calvo JF, et al. Determination of optimal tolerance for MLC positioning in sliding window and VMAT techniques. Med Phys 2015;42:1911–6. [39] Johnson D, Weston SJ, Cosgrove VP, Thwaites DI. A simple model for predicting the signal for a head-mounted transmission chamber system, allowing IMRT in-vivo dosimetry without pretreatment linac time. J Appl Clin Med Phys 2014;15:4842. [40] Poppe B, Looe HK, Chofor N, Rühmann A, Harder D, Willborn KC. Clinical performance of a transmission detector array for the permanent supervision of IMRT deliveries. Radiother Oncol 2010;95:158–65. [41] Korevaar EW, Wauben DJL, van der Hulst PC, Langendijk JA, van’t Veld AA. Clinical introduction of a linac head-mounted 2D detector array based quality assurance system in head and neck IMRT. Radiother Oncol 2011;100:446–52. [42] Van Zijtveld M, Dirkx ML, de Boer HC, Heijmen BJ. 3D dose reconstruction for clinical evaluation of IMRT pretreatment verification with an EPID. Radiother Oncol 2007;82:201–7.

406

Improving radiotherapy through medical physics developments

[43] McDermott LN, Wendling M, Sonke JJ, van Herk M, Mijnheer BJ. Replacing pretreatment verification with in vivo EPID dosimetry for prostate IMRT. Int J Radiat Oncol Biol Phys 2007;67:1568–77. [44] Rozendaal RA, Mijnheer BJ, van Herk M, Mans A. In vivo portal dosimetry for head-and-neck VMAT and lung IMRT: linking c-analysis with differences in dose–volume histograms of the PTV. Radiother Oncol 2014;112:396–401. [45] Rozendaal RA, Mijnheer BJ, Hamming-Vrieze O, Mans A, van Herk M. Impact of daily anatomical changes on EPID-based in vivo dosimetry of VMAT treatments of head-and-neck cancer. Radiother Oncol 2015;116:70–4. [46] Stell AM, Li JG, Zeidan OA, Dempsey JF. An extensive log-file analysis of stepand-shoot intensity modulated radiation therapy segment delivery errors. Med Phys 2004;31:1593–602. [47] Rangaraj D, Zhu M, Yang D, et al. Catching errors with patient-specific pretreatment machine log file analysis. Pract Radiat Oncol 2012;3:80–90. [48] Kruse JJ, Mayo CS. Comment on ‘‘Catching errors with patient-specific pretreatment machine log file analysis”. Pract Radiat Oncol 2013;3:91–2. [49] Pasler M, Kaas J, Perik T, et al. Linking log files with dosimetric accuracy – a multi-institutional VMAT QA study. Radiother Oncol 2015;117:407–11. [50] Adolfsson E, Gustafsson H, Lund E, et al. A system for remote dosimetry audit of 3D-CRT, IMRT and VMAT based on lithium formate dosimetry. Radiother Oncol 2014;113:279–82. [51] Fogliata A, Belosi F, Clivio A, et al. On the pre-clinical validation of a commercial model-based optimisation engine: application to volumetric modulated arc therapy for patients with lung or prostate cancer. Radiother Oncol 2014;113:385–91. [52] Ableitinger A, Vatnitsky S, Herrmann R, et al. Dosimetry auditing procedure with alanine dosimeters for light ion beam therapy. Radiother Oncol 2013;108:99–106. [53] Kuess P, Bozsaky E, Hopfgartner J, et al. Dosimetric challenges of small animal irradiation with a commercial X-ray unit. Z Med Phys 2014;24:363–72. [54] Zurl B, Tiefling R, Winkler P, et al. Hounsfield units variations: impact on CTdensity based conversion tables and their effects on dose distribution. Strahlenther Onkol 2014;190:88–93. [55] Georg D, Hopfgartner J, Gòra J, et al. Dosimetric considerations to determine the optimal technique for localized prostate cancer among external photon, proton, or carbon-ion therapy and high-dose-rate or low-dose-rate brachytherapy. Int J Radiat Oncol Biol Phys 2014;88:715–22. [56] Veiga C, McClelland J, Moinuddin S, et al. Toward adaptive radiotherapy for head and neck patients: feasibility study on using CT-to-CBCT deformable registration for ‘‘dose of the day” calculations. Med Phys 2014;41:031703. [57] Gangsaas A, Astreinidou E, Quint S, et al. Cone-beam computed tomographyguided positioning of laryngeal cancer patients with large interfraction time trends in setup and nonrigid anatomy variations. Int J Radiat Oncol Biol Phys 2013;87:401–6. [58] Hunter KU, Fernandes LL, Vineberg KA, et al. Parotid glands dose-effect relationships based on their actually delivered doses: implications for adaptive replanning in radiation therapy of head-and-neck cancer. Int J Radiat Oncol Biol Phys 2013;87:676–82. [59] Tuomikoski L, Valli A, Tenhunen M, et al. A comparison between two clinically applied plan library strategies in adaptive radiotherapy of bladder cancer. Radiother Oncol 2015;117:448–52. [60] Heijkoop ST, Langerak TR, Quint S, et al. Quantification of intra-fraction changes during radiotherapy treatment of cervical cancer assessed with preand post-fraction CBCT scans. Radiother Oncol 2015;117:536–41. [61] Olteanu LA, Berwouts D, Madani I, et al. Comparative dosimetry of threephase adaptive and non-adaptive dose-painting IMRT for head-and-neck cancer. Radiother Oncol 2014;111:348–53. [62] Vestergaard A, Muren LP, Søndergaard J, et al. Adaptive plan selection vs. reoptimisation in radiotherapy for bladder cancer: a dose accumulation comparison. Radiother Oncol 2013;109:457–62. [63] Schwartz DL, Garden AS, Shah SJ, et al. Adaptive radiotherapy for head and neck cancer–dosimetric results from a prospective clinical trial. Radiother Oncol 2013;106:80–4. [64] Sharfo AW, Voet PW, Breedveld S, et al. Comparison of VMAT and IMRT strategies for cervical cancer patients using automated planning. Radiother Oncol 2015;114:395–401. [65] Poels K, Depuydt T, Verellen D, et al. Improving the intra-fraction update efficiency of a correlation model used for internal motion estimation during real-time tumor tracking for SBRT patients: fast update or no update? Radiother Oncol 2014;112:352–9. [66] Furtado H, Steiner E, Stock M, et al. Real-time 2D/3D registration using kV-MV image pairs for tumor motion tracking in image guided radiotherapy. Acta Oncol 2013;52:1464–71. [67] Falk M, Pommer T, Keall P, et al. Motion management during IMAT treatment of mobile lung tumors – a comparison of MLC tracking and gated delivery. Med Phys 2014;41:101707. [68] Peguret N, Dahele M, Cuijpers JP, et al. Frameless high dose rate stereotactic lung radiotherapy: intrafraction tumor position and delivery time. Radiother Oncol 2013;107:419–22. [69] Bedford JL, Fast MF, Nill S, et al. Effect of MLC tracking latency on conformal volumetric modulated arc therapy (VMAT) plans in 4D stereotactic lung treatment. Radiother Oncol 2015;117:491–5. [70] Van den Begin R, Engels B, Gevaert T, et al. Impact of inadequate respiratory motion management in SBRT for oligometastatic colorectal cancer. Radiother Oncol 2014;113:235–9.

[71] Dhont J, Verellen D, Poels K, et al. Feasibility of markerless tumor tracking by sequential dual-energy fluoroscopy on a clinical tumor tracking system. Radiother Oncol 2015;117:487–90. [72] Burman C, Kutcher GJ, Emami B, Goitein M. Fitting of normal tissue tolerance data to an analytic function. Int J Radiat Oncol Biol Phys 1991;21:123–35. [73] Bentzen SM, Constine LS, Deasy JO, et al. Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC): an introduction to the scientific issues. Int J Radiat Oncol Biol Phys 2010;76:S3–9. [74] Bortfeld T, Jeraj R. The physical basis and future of radiation therapy. Br J Radiol 2011;84:485–98. [75] Deasy JO, Muren LP. Advancing our quantitative understanding of radiotherapy normal tissue morbidity. Acta Oncol 2014;53:577–9. [76] Bentzen SM. Randomized controlled trials in health technology assessment: overkill or overdue? Radiother Oncol 2008;86:142–7. [77] Olsen DR, Overgaard J. Leveraging clinical performance by technological excellence – the case of particle therapy. Radiother Oncol 2010;95:1–2. [78] Goitein M. Trials and tribulations in charged particle radiotherapy. Radiother Oncol 2010;95:23–31. [79] Langendijk JA, Lambin P, De Ruysscher D, Widder J, Bos M, Verheij M. Selection of patients for radiotherapy with protons aiming at reduction of side effects: the model-based approach. Radiother Oncol 2013;107:267–73. [80] Lambin P, Zindler J, Vanneste B, et al. Modern clinical research: how rapid learning health care and cohort multiple randomised clinical trials complement traditional evidence based medicine. Acta Oncol 2015;54:1289–300. [81] Lambin P, van Stiphout RG, Starmans MH, et al. Predicting outcomes in radiation oncology–multifactorial decision support systems. Nat Rev Clin Oncol 2013;10:27–40. [82] Yahya N, Ebert MA, Bulsara M, et al. Urinary symptoms following external beam radiotherapy of the prostate: dose-symptom correlates with multiple-event and event-count models. Radiother Oncol 2015;117:277–82. [83] Wortel RD, Witte MG, van der Heide UA, et al. Dose-surface maps identifying local dose-effects for acute gastrointestinal toxicity after radiotherapy for prostate cancer. Radiother Oncol 2015;117:515–20. [84] Michalski JM, Purdy JA, Winter K, et al. Preliminary report of toxicity following 3D radiation therapy for prostate cancer on 3DOG/RTOG 9406. Int J Radiat Oncol Biol Phys 2000;46:391–402. [85] Viswanathan AN, Yorke ED, Marks LB, Eifel PJ, Shipley WU. Radiation dose– volume effects of the urinary bladder. Int J Radiat Oncol Biol Phys 2010;76: S116–22. [86] Carillo V, Cozzarini C, Rancati T, et al. Relationships between bladder dose– volume/surface histograms and acute urinary toxicity after radiotherapy for prostate cancer. Radiother Oncol 2014;111:100–5. [87] Heemsbergen WD, Al-Mamgani A, Witte MG, van Herk M, Pos FJ, Lebesque JV. Urinary obstruction in prostate cancer patients from the Dutch trial (68 Gy vs. 78 Gy): relationships with local dose, acute effects, and baseline characteristics. Int J Radiat Oncol Biol Phys 2010;78:19–25. [88] De Langhe S, De Meerleer G, De Ruyck K, et al. Integrated models for the prediction of late genitourinary complaints after high-dose intensity modulated radiotherapy for prostate cancer: making informed decisions. Radiother Oncol 2014;112:95–9. [89] Olsson CE, Pettersson N, Alsadius D, et al. Patient-reported genitourinary toxicity for long-term prostate cancer survivors treated with radiation therapy. Br J Cancer 2013;108:1964–70. [90] Thor M, Bentzen L, Hysing LB, et al. Prediction of rectum and bladder morbidity following radiotherapy of prostate cancer based on motioninclusive dose distributions. Radiother Oncol 2013;107:147–52. [91] Gulliford SL, Partridge M, Sydes MR, Andreyev J, Dearnaley DP. A comparison of dose–volume constraints derived using peak and longitudinal definitions of late rectal toxicity. Radiother Oncol 2010;94:241–7. [92] Fiorino C, Rancati T, Fellin G, et al. Late fecal incontinence after high-dose radiotherapy for prostate cancer: better prediction using longitudinal definitions. Int J Radiat Oncol Biol Phys 2012;83:38–45. [93] Partridge M, Yamamoto T, Grau C, Høyer M, Muren LP. Imaging of normal lung, liver and parotid gland function for radiotherapy. Acta Oncol 2010;49: 997–1011. [94] Casares-Magaz O, Thor M, Liao D, et al. An image-based method to quantify biomechanical properties of the rectum in radiotherapy of prostate cancer. Acta Oncol 2015;54:1335–42. [95] Helmbrecht S, Enghardt W, Parodi K, et al. Analysis of metabolic washout of positron emitters produced during carbon ion head and neck radiotherapy. Med Phys 2013;40:091918. [96] Kuess P, Helmbrecht S. Fiedler F et al Automated evaluation of setup errors in carbon ion therapy using PET: feasibility study. Med Phys 2013;40:121718. [97] Jakob B, Durante M. Radiation dose detection by imaging response in biological targets. Radiat Res 2012;177:524–32. [98] Nischwitz SP, Bauer J, Welzel T, et al. Clinical implementation and range evaluation of in vivo PET dosimetry for particle irradiation in patients with primary glioma. Radiother Oncol 2015;115:179–85. [99] Janssens G, Smeets J, Vander Stappen F, et al. Sensitivity study of prompt gamma imaging of scanned beam proton therapy in heterogeneous anatomies. Radiother Oncol 2015 (in press). [100] Bortfeld T, Torresin A, Fiorino C, et al. The research versus clinical service role of medical physics. Radiother Oncol 2015;113:285–8.