Accepted Manuscript
Measurement of the mid-infrared absorption spectra of ethylene (C2 H4 ) and other molecules at high temperatures and pressures C.L. Strand, Y. Ding, S.E. Johnson, R.K. Hanson PII: DOI: Reference:
S0022-4073(18)30538-7 https://doi.org/10.1016/j.jqsrt.2018.10.030 JQSRT 6267
To appear in:
Journal of Quantitative Spectroscopy & Radiative Transfer
Received date: Revised date: Accepted date:
23 July 2018 18 September 2018 18 October 2018
Please cite this article as: C.L. Strand, Y. Ding, S.E. Johnson, R.K. Hanson, Measurement of the mid-infrared absorption spectra of ethylene (C2 H4 ) and other molecules at high temperatures and pressures, Journal of Quantitative Spectroscopy & Radiative Transfer (2018), doi: https://doi.org/10.1016/j.jqsrt.2018.10.030
This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
ACCEPTED MANUSCRIPT Journal of Quantitative Spectroscopy and Radiative Transfer manuscript No. (will be inserted by the editor)
C. L. Strand1 · Y. Ding1 · S. E. Johnson1 · R. K. Hanson1 Christopher L. Strand
[email protected] 1
CR IP T
Measurement of the mid-infrared absorption spectra of ethylene (C2H4) and other molecules at high temperatures and pressures
the date of receipt and acceptance should be inserted later
6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
21
22 23 24 25 26 27
bustion systems, hypersonic flows, industrial processes, and exhaust stacks. Correspondingly, these gases are the subject of scientific study and engineering employ for many fields, including astrophysics, environmental science, plasma physics, combustion science, aerospace engineering, chemical engineering, and energy systems engineering. In the endeavor to study and monitor hightemperature gases, infrared absorption and emission spectroscopy offer a powerful toolset for understanding the characteristics of these environments [1–7]. This work presents a methodology using shock tube facilities in conjunction with rapid-tuning, broad-scan, narrowlinewidth lasers to measure the high-temperature and high-pressure absorption spectra of molecules in the mid-infrared. Several databases exist to collate the infrared spectra and spectroscopic parameters of gaseous molecules. The most comprehensive and prominent line parameter and cross section databases, such as HITRAN, GIESA, PNNL Northwest Infrared, and NIST Quantitative Infrared Database, focus on molecules at or near room temperature and atmospheric pressures [8–11] . Additionally, there are a few databases, including HITEMP and ExoMol, that provide high-temperature spectral data but only for a limited subset of molecules [1, 3]. The limited availability of high-temperature and high-pressure absorption and emission spectra stem primarily from the considerable challenges these conditions pose for ab initio, empirical, and experimental methods. High temperatures require the consideration of hot lines that emerge due to the population of higher energy levels, including high-J rovibrational transitions and
M
5
ED
4
PT
3
Received: date / Accepted: date Abstract A methodology for the measurement of midinfrared absorption cross sections of gaseous molecules at high temperatures and pressures is presented. A rapidtuning, broad-scan external cavity quantum cascade laser with a tuning rate in excess of 30 000 cm−1 s−1 has been employed in the measurement of full vibrational bands (>100 cm−1 ) in shock-heated test gases. The approach is demonstrated with measurements of the absorption cross section of ethylene (C2 H4 ) in the 8.5 µm to 11.7 µm region for temperatures from 800 K to 1600 K and pressures from 1 atm to 5 atm. Decreasing peak strength with temperature is observed as well as pressure-insensitivity. The measurements are compared with existing experimental, empirical, and ab initio databases. Additionally, illustrative absorption cross section measurements of propene (C3 H6 ), 1-butene (1C4 H8 ), 2-butene (2-C4 H8 ), 1,3-butadiene (1,3-C4 H6 ), and methanol (CH3 OH) are presented near 1000 K and 2.3 atm.
CE
2
AC
1
AN US
High Temperature Gasdynamics Laboratory, 452 Escondido Mall, Bldg. 520, Thermosciences Division, Stanford University, Stanford, CA 94305, USA
1 Introduction
There exists a marked lack of experimental absorption spectra for high-temperature and high-pressure gaseous molecules. Gases in these high-enthalpy thermodynamic states are present in a wide range of natural and manmade environments, such as cool stars, exoplanets, plasmas, explosions, flames, volcanoes, forest fires, comAddress(es) of author(s) should be given
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59
ACCEPTED MANUSCRIPT C. L. Strand1 et al.
2
67
68 69 70 71 72 73 74
75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95
96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111
Due to the weakness of hot lines at low temperatures and practical database considerations, hot lines are not typically observed, calculated, nor included in experimental, empirical, and ab initio room-temperature databases. This makes it impossible to accurately extrapolate room-temperature spectroscopic data to higher temperatures [2]. There are presently several initiatives to calculate, measure, and collate absorption spectra at high temperatures, including the two predominant databases HITEMP and ExoMol [1, 3, 13]. Unfortunately, the experimental validation is often quite limited, especially for larger molecules. This lack of experimental validation is primarily the result of the same challenges that make any experimentation at high-temperature, high-pressure conditions difficult; namely the challenge of generating a well-known, homogeneous, chemically-stable, highenthalpy gas state that remains steady for a sufficient duration to perform the desired experiment. All laboratory approaches achieve only a subset of these desired characteristics and must compromise on some to faithfully maintain the others. Moreover, the requirement of a stable chemical composition generally imposes an unavoidable upper-bound on the duration of the experiment. At elevated temperatures, accelerated reaction rates limit the experimental test time available to any experimental approach (e.g., the thermal decomposition of large molecules).
CR IP T
66
AN US
65
In addition to the challenges of generating the desired conditions in a laboratory, the experimental challenges are further increased for the collection of spectroscopic reference data under these circumstances. This is due both to the characteristics of molecular spectra at high temperatures/pressures and the performance of the tools used to acquire spectra. High temperatures and high pressures lead to significant line broadening. The outcome of these broadening effects, in concert with the emergence of hot lines, is highly congested and blended spectra; wherein, individual lines are typically not observable and the local absorption or emission intensity is the result of the superposition of many neighboring lines. At these extreme conditions, the most practical parameterization of experimental spectroscopic measurements for both the interpretation of observed spectra and the validation of spectroscopic models is the wavelengthdependent absorption cross section over full absorption bands. Unfortunately, standard spectroscopic equipment such as spectrometers, FTIRs, and narrow-linewidth lasers generally provide a slow rate of acquisition for broad spectra and thus demand a laboratory approach to high-enthalpy conditions that emphasizes experimental duration at the cost of thermodynamic condition accuracy and range. The recent development of rapid-tuning, broad-scan, narrow-linewidth lasers in the mid-infrared has enabled, for the first time, the practical use of a shock tube to perform quantitative broadband absorption spectroscopy measurements. Through tuning rates in excess of 30 000 cm−1 s−1 , it has become possible to acquire the high-temperature absorption cross section over entire branches, or even entire bands, of large molecules during the short-duration steady test time of a shock tube.
M
64
ED
63
PT
62
vibrational hot bands. As a consequence, the number of lines that must be considered for accurate spectral modeling at high temperatures often increases by several orders of magnitude [1, 2, 12]. This issue is further compounded by increasing molecular size and correspondingly the number of vibrational modes, leading to the number of infrared lines for a single gas species to count in the billions.
Standard approaches for achieving high-enthalpy conditions include radiative/conductive heating, rapidcompression, arc-heating, and shock-heating. With the exception of shock-heating, these approaches generally provide extended high-temperature test durations (from 100 ms up to several minutes) at the expense of stable chemical composition, temperature uniformity, or thermodynamic equilibrium, respectively. Shock-heating provides a near-ideal mechanism for instantaneously achieving a well-known, homogeneous, high-temperature and high-pressure environment with maximum temperatures and pressures in excess of 10 000 K and 1000 atm, respectively. There is unfortunately the significant caveat of a very short test time (typically 1 ms to 10 ms but up to 100 ms is possible) in facilities that employ this mechanism, such as shock tubes.
CE
61
AC
60
112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145
2 Experimental Methods
146
2.1 Shock Tube
147
The experiments in this work were performed in a pressure-driven, high-purity, stainless steel shock tube with an inner diameter of 14.13 cm [14, 15]. The shock tube consists of a 7.12 m high-pressure driver section followed by a 8.54 m low-pressure driven section that are separated by a polycarbonate diaphragm. The postreflected shock conditions are determined using shock jump relations, assuming frozen chemistry. The necessary inputs are provided by the known initial driver gas conditions and the incident shock speeds measured using five piezoelectric pressure transducers distributed over the final 1.5 m of the driven section. Uncertainty in the experimental pressure and temperature are each less than ±1 % [14–16]. The test plane is 2 cm from
148 149 150 151 152 153 154 155 156 157 158 159 160 161
ACCEPTED MANUSCRIPT Measurement of high-T and high-P absorption spectra
3
1 2 0 0
0 .6 5 1 .9 8
W a v e n u m b e r [c m
2 .0 0
2 .0 2
2 .0 4
2 .0 6
M a x R a te : 4 0 k c m -1 / s
1 .0
2 .0 8
0 .8
1 0 5 0 0 .6 1 0 0 0 0 .4
9 5 0
0 .2
9 0 0 M a x R a te : 3 0 k c m -1 / s
8 5 0 0
2
0 .0 4
6
8
1 0
T im e [m s ]
Fig. 1 Wavenumber and intensity tuning characteristics of
167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187
188
M
166
ED
165
PT
164
CE
163
the end wall of the shock tube with instrument access provided by eight ports. For these experiments, one pair of ports was equipped with ZnSe windows with a 300 wedge and a broadband anti-reflection (AR) coating providing less than 1 % reflection per surface over the wavelength range of 7 µm to 12 µm. These window characteristics minimize etalon fringe noise when tuning the wavelength of a laser. Another pair of ports was equipped with flat AR-coated ZnSe windows (Ravg <5 % over 8 µm to 12 µm) for use with fixed wavelength lasers where etalon fringe noise is not a concern. Additionally, one port was instrumented with a transducer to record the pressure in the post-reflected shock region. Helium and helium-nitrogen driver gas mixtures, as well as driver-section volume inserts, were used to achieve long test times with a steady pressure profile over a broad range of temperature and pressure conditions [17,18]. Test gas mixtures were prepared manometrically in a stainless-steel mixing tank using either neat gases (>99 %) or certified standard gas mixtures (±2 % uncertainty on reported concentration) to supply the target species and high-purity argon (>99.999 %) as a diluent. For the measurements reported here, only dilute test mixtures in argon with a target species concentration no greater than 5 % were used in order to limit the endothermic effects of pyrolysis at high temperatures.
AC
162
AN US
the Daylight Solutions MIRcat-QT EC-QCL. QCL 1 spans approximately 8.5 µm to 10.5 µm (926 cm−1 to 1178 cm−1 ) and QCL 2 spans approximately 10.5 µm to 11.7 µm (865 cm−1 to 920 cm−1 ).
2.2 Lasers and Optics Two laser systems were integrated into the shock tube in order to perform absorption cross section measurements using the fractional transmission through the test gas. The fractional transmission is determined by the Beer-
(1)
where I is the transmitted intensity, I0 is the incident intensity, α is the absorbance, σ is the absorption cross section in m2 mol−1 , n is the number density of the absorbing species in mol m−1 , and L is the path length through the gas sample in m. The first laser system used a Daylight Solutions MIRcat-QTTM with rapid ultra-broad wavelength tuning in order to acquire absorption cross section measurements over a large wavelength range within the test time of the shock tube. As presented in Figure 1, the MIRcat-QTTM is outfitted with two external-cavity quantum cascade laser (EC-QCL) modules with wavelength coverage from approximately 8.5 µm to 10.5 µm (926 cm−1 to 1178 cm−1 ) for QCL 1 (M2095-PCX) and approximately 10.5 µm to 11.7 µm (865 cm−1 to 920 cm−1 ) for QCL 2 (M2115-PC). Variations in the emission intensity are characteristic of the quantum cascade gain medium and are specific to individual lasers. Generally, the emission intensity is strongest in the middle of the coverage region and decreases to zero at the edges. There was approximately a 6 cm−1 gap between the spectral coverage offered by these two modules. The laser modules provided a maximum tuning rate in excess of 30 000 cm−1 s−1 and enabled the full ranges of QCL 1 and QCL 2 to be tuned in less than 10 ms and 4 ms, respectively. The maximum possible tuning rate was used for all experiments here and only a single laser module was operated during an individual shock tube experiment. With test times ranging from 2 ms to 8 ms for the temperature and pressure conditions studied in this work, spectral measurements over the full wavelength range of the two module laser system could typically be achieved with two to three repeated experiments. A pressure transducer monitoring the passage of the incident shockwave 3.23 m from the shock tube end wall was used to provide the timing signal for the laser system. The rise in the pressure transducer signal was conditioned into a TTL pulse with a variable delay by a pulse/delay generator in order to control the start of the laser scan. The latency between the laser receiving the trigger signal and the start of the laser scan was typically less than 300 ns. The desired start wavelength, end wavelength, and tuning rate for each experiment were configurable in the MIRcat-QTTM control software. The combination of a variable timing delay and selectable start wavelength enabled piece-wise measurement of absorption spectra in cases where the test time was insufficient for the laser to perform a complete scan.
CR IP T
1 1 0 0
Lambert relation: I = exp (−α) = exp (−σnL), I0
1 .2
Q C L # 1 Q C L # 2
In te n s ity [A .U .]
1 1 5 0
0 .7 5 0 .7 0
-1
]
0 .8 0
189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238
ACCEPTED MANUSCRIPT C. L. Strand1 et al.
4
246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291
Windows
Beam Splitters
End Wall
Wavelength Reference Cell
Intensity Ref. Det.
Iris + Filter
Signal Detector
CR IP T
245
Shock Tube
Wavelength Ref. Det.
Fig. 2 Schematic of a shock tube configured with a broad-
scan rapidly-tuned external-cavity quantum cascade laser. The setup includes an intensity reference detector for commonmode-rejection and a gas-filled wavelength reference cell and detector for wavelength calibration. (Not shown: Fixedwavelength CO2 gas laser configured with co-planar alignment.)
AN US
244
Rapidly-tuned Broad-scan EC-QCL
common-mode noise rejection and thus correct for any 292 laser intensity variations during an experiment. The 293 wavelength reference beam path included a gas cell 294 filled with a mixture of components selected for well- 295 known room-temperature absorption features within the 296 scan range of the laser modules. For the experiments 297 performed here, the mixture was 0.5 % ethylene, 0.8 % 298 propene, and 2 % benzene in a balance of nitrogen at 299 1 atm. The absorption features produced by this gas 300 mixture provided an absolute wavelength reference for 301 correcting any variations in wavelength tuning perfor- 302 mance. 303 For the second laser system, an Access Laser CompanyTM 304 CO2 gas laser was used to measure the absorption cross 305 section at a fixed wavelength and monitor any vari- 306 ations in the concentration of the species of interest 307 during the test time. In the ethylene (C2 H4 ) experi- 308 ments presented here, this laser was operated at the 309 fixed wavelength of 10.532 µm (949.49 cm−1 ) to probe 310 the peak of the fundamental ν7 vibrational band (CH2 311 wag mode) [20, 21]. The beam was aligned through the 312 shock tube ports equipped with flat AR-coated ZnSe 313 windows and focussed onto a Vigo SystemsTM MCT 314 detector (PVM-2TE-10.6). The wavelength of the laser 315 was monitored before and after each experiment using 316 a Bristol InstrumentsTM 771B-XIR spectrum analyzer. 317
M
243
ED
242
PT
241
Figure 1 presents the wavelength-dependent relative intensity for each laser module. The large variation in intensity from the edge to the center of the emission band leads to a corresponding variation in signal-tonoise ratio (SNR). Absorption cross section measurements in regions with insufficient SNR are excluded from the results presented here. This exclusion criteria typically reduced the total tuning range by less than 2 %. Repeated experiments with variable gain/attenuation could be used to recover these low SNR regions. The inset of Figure 1 presents a detailed view of the laser intensity while rapidly tuning the wavelength. The sawtooth-shaped intensity output is the result of ‘micro-hops’ in the laser mode as the grating angle is rotated [19]. Instead of continuous wavelength tuning, the laser emits at a steady, fixed wavelength (linewidth: ≤0.0033 cm−1 ) corresponding to the dominant laser mode until it hops in a discrete step ranging in size from approximately 0.2 cm−1 to 0.6 cm−1 . This dominant laser mode is randomly selected from a limited set of candidate modes determined by the combination of the cavity modes (spaced at approximately 0.1 cm−1 ), the laser gain curve, and the instantaneous grating dispersion curve. As the grating is rotated, the shifting center wavelength of the grating dispersion curve causes the dominant cavity mode to become weaker leading to a drop in intensity until this cavity mode exits the grating dispersion curve. At this moment the laser hops to a new dominant cavity mode, randomly selected among the candidate modes for that grating angle, and the emitted intensity undergoes a sharp step-like rise. Absorption measurements performed using this form of laser tuning are best interpreted as a sequence of individual narrow-linewidth, fixed-wavelength measurements each with the duration of the corresponding intensity sawtooth. The resulting spectrum comprises discrete absorption cross section values at irregularly spaced wavenumbers. The average spectral interval of the ‘micro-hops’ (0.35 cm−1 ) exceeds the laser linewidth by more than a factor of 100, resulting in a highlyresolved but under-sampled spectrum. As illustrated in Figure 2, the laser beam was aligned through the shock tube ports equipped with wedged AR-coated ZnSe windows and passed through an iris and long-pass infrared filter before being focussed onto a Vigo SystemsTM large-area thermoelectrically-cooled MCT detector (PVM-2TE-10.6). The iris and long-pass infrared filter reduced the quantity of emission from the hot test gas that reached the detector. Two ZnSe beam splitters were used to direct a fraction of the beam toward both an intensity reference detector and a wavelength reference detector. The intensity reference detector provided a means to perform
CE
240
AC
239
2.3 EC-QCL Wavelength Calibration To maintain an accurate wavelength reference for the measured spectra, the EC-QCL wavelength was calibrated relative to the grating-angle at the factory, in-
318
319 320 321
ACCEPTED MANUSCRIPT Measurement of high-T and high-P absorption spectra
334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364
365 366
367 368 369 370 371
n
g
t h
[ μ
m
]
9 .8 0
9 .7 1
9 .6 2
9 .5 2
/m o l] 2
8
6
4
CR IP T
333
l e
M e a s .: 2 9 8 K , 1 a tm P N N L : 2 9 8 K , 1 a tm
C r o s s S e c tio n [m
332
2
0
R e s id u a l [% ]
331
v e
9 .9 0
3 0
R e s id u a l =
1 5
M e a s.
0 -1 5 -3 0 0 .2
S h i f t =
]
330
a
1 0
-1
329
1 0 .0 0
1 2
S h ift [c m
328
1 0 .1 0
AN US
327
W
1 0 .2 0
0 .1
P e a k ,M e a s .
-
P N N L
×1 0 0 %
P N N L
−
P e a k ,P N N L
0 .0
-0 .1 -0 .2
9 8 0
9 9 0
1 0 0 0
1 0 1 0
1 0 2 0
W a v e n u m b e r [c m
-1
1 0 3 0
1 0 4 0
1 0 5 0
]
Fig. 3 Comparison of the propene absorption cross section
measured at 298 K and 1 atm with the corresponding cross section catalogued in the PNNL Northwest Infrared database [10].
M
326
ED
325
PT
324
CE
323
dependently characterized, and then corrected for drift. The factory calibration was reassessed using a spectrum analyzer, the laser output was found to have a linear relationship of 1.001 cm−1 /cm−1 (R-squared: 0.9983) and 0.999 cm−1 /cm−1 (R-squared: 0.9999) between the measured and calibrated wavelengths, respectively for QCL 1 and QCL 2. While the absolute wavelength indicated by the laser was found to drift slightly, the linearity of the relative wavelength was found to be stable. When tuned rapidly, a wavelength reference pulse was generated every 0.5 cm−1 and recorded alongside the detector signals. The fixed-wavelength for each ‘microhop’ was determined by linearly interpolating the wavelength reference pulse signal at the timing of each steplike rise observed in the laser intensity. The average intensity during each individual ‘micro-hop’ was used in determining the absorbance at the corresponding wavelength. To assign an absolute wavelength to the measured spectra and correct any drifts in the absolute value of the output wavelength provided by the laser system, a known reference spectrum was measured simultaneously during every shock tube experiment using the configuration detailed in Figure 2 and Section 2.2. The room-temperature wavelength reference cell provided an absorption spectrum with several strongly absorbing peaks with center wavelengths known to within 0.06 cm−1 [10]. To ensure absolute wavelength accuracy in the region of greatest interest, a single prominent reference feature nearest the ethylene band peak was used to assign absolute values to the well-known relative wavelength values during tuning. In the case of QCL 1, the ethylene peak at 949.35 cm−1 was used for absolute wavelength correction. For QCL 2, the prominent propene peak at 912.58 cm−1 was used. Comparing the resulting calibration to the known locations of other prominent peaks observed in the reference cell mixture of ethylene, propene, and benzene, wavelength discrepancies of less than ±0.1 cm−1 were observed over the range of the scan. To ensure that the accuracy of the measured spectra were not influenced by small absolute wavelength drifts, the above calibration was performed during each shock tube experiment.
AC
322
5
2.4 Absorption Cross Section and Wavelength Validation Validation of the measurement methodology was performed at room temperature and atmospheric pressure where the results may be compared to the PNNL Northwest Infrared database [10]. Figure 3 presents this comparison for propene. As can be observed, the expected
cross section values are faithfully reproduced with residuals not generally exceeding ±10 % and major peak locations correctly located within ±0.15 cm−1 . Additionally, the measured integrated cross section over the range of wavelengths in the figure is 5.9 % lower than that calculated for the PNNL Northwest Infrared database. These discrepancies are within expectation given that the PNNL reference spectra have a smaller spectral interval of 0.06 cm−1 and larger instrument resolution of 0.112 cm−1 enabling narrow spectral features to be more reliably captured in comparison to the measured results [10]. At higher temperatures and pressures, line broadening mitigates the need for a smaller spectral interval. Additional validation of the absorption cross section measured by the EC-QCL was provided during every shock tube experiment by the co-planar CO2 laser operating at 949.49 cm−1 . As demonstrated in Figure 4, the measured absorbance on both lasers agree at the moment the EC-QCL tunes to the CO2 laser wavelength.
372 373 374 375 376 377 378 379 380 381 382 383 384 385
386 387 388 389 390 391
ACCEPTED MANUSCRIPT C. L. Strand1 et al.
6
399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443
CR IP T
398
AN US
397
The time-dependent concentration and temperature observed during high-temperature experiments influence the absorbance measured by the scanned-wavelength EC-QCL. In the results presented here, the known timedependent concentration, as measured by the fixedwavelength CO2 laser, is used to correct the absorption cross section for the decreasing C2 H4 concentration. The modeled temperature time-histories and the temperature-dependent absorption cross sections measured by Ren et al. are used to determine the C2 H4 concentration throughout the test time [21]. The dependence of the absorption cross section on temperature at other measured wavelengths besides 10.532 µm is not independently known and is the subject of this work, thus the scanned-wavelength cross section values reported in figures here are not corrected for variations in temperature but rather the variation in temperature over the duration of the test time is reported alongside each spectra. In the electronic distribution of these results, the corresponding instantaneous temperature (and pressure) are reported for the measured cross section at each individual wavelength that was investigated.
444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465
3 High-T and High-P Absorption Spectra
466
3.1 Ethylene
467
M
396
ED
395
PT
394
The duration of the test time available for the measurement of absorption cross sections in a shock tube experiment is dependent upon the nominal temperature and pressure conditions as well as the mixture composition. Figure 4 presents the time-dependent characteristics of a low-temperature and a high-temperature test condition employed in the investigation of the C2 H4 absorption cross section. For each condition, the pressure time-history measured at the measurement plane is given. Within the test time, the standard deviation of the pressure was observed to be less than 1.5 %. A conservative cut-off threshold of 100 µs prior to a pressure change exceeding ±2.5 % provides the primary criteria for the end of the test time. For the low-temperature and high-temperature conditions presented here, the test times were 8.6 ms and 3.0 ms, respectively. Given the increasing rate of decomposition with temperature for species of interest, deviations in temperature and composition must also be considered when interpreting the measured absorption spectra and defining the serviceable test time. Figure 4 includes the absorbance time-histories measured by both the scannedwavelength EC-QCL and the fixed-wavelength CO2 laser. The fixed-wavelength absorbance measurement allows the target species (C2 H4 ) concentration to be monitored throughout the experiment. As illustrated in the figure, at low temperatures the absorbance, and thus concentration, was stable throughout the test time, while at hightemperatures the concentration was rapidly decreasing. For the high-temperature case the absorbance dropped by 50 % over the duration of the test time. Decomposition at temperatures appreciably above 1625 K sufficiently curtailed the test time such that measurements were deemed impractical with the presently available wavelength tuning rates. In addition to decreasing C2 H4 concentration, this endothermic decomposition caused the gas temperature to decrease. The calculated variations in temperature due to decomposition are also presented in Figure 4. The time-dependent temperatures for each condition were determined using the ARAMCOMECH 2.0 C2 H4 mechanism in Chemkin-ProTM version 17.2 [22]. The calculations assumed a constant enthalpy reactor with the pressure time-history defined by the measured values. The initial conditions included a temperature determined by frozen-chemistry shock jump relations and a known mixture composition. In the low-temperature condition, where no appreciable decomposition occurs, the temperature is nominally steady. For the high-temperature condition, the temperature dropped 4.1 % over the duration of the test time.
CE
393
2.5 Experiment Test Time
AC
392
C2 H4 was the first species to be thoroughly investigated using the methodology described above. This species was selected as the initial target based upon favorable spectroscopic and kinetic characteristics, as well as relevance to numerous fields of study. First, the absorption spectra of C2 H4 at high temperatures and pressures is sufficiently broadened that the limited spectral interval of the EC-QCL measurements will capture the dominant features. Smaller molecular species may prove to be challenging with this methodology due to narrow spectral features except at very high temperatures and pressures. C2 H4 is spectroscopically interesting due to the present lack of high-temperature experimental datasets while still being a sufficiently simple molecule that it has been the subject of recent ab initio modeling efforts at high-temperatures [12]. The measurements presented here serve to appreciably expand the range of temperatures, pressures, and wavelengths for which quantitative experimental C2 H4 absorption spectroscopy data is available [10, 20, 21, 23–39]. Next, the comparatively slow decomposition rate of C2 H4 relative to other larger, less stable molecules allows for longer test times at high-temperatures before the test gas concentration is significantly depleted and the temperature perturbed. The well-studied kinetics of C2 H4 pyrolysis enable high-confidence in predicting
468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493
ACCEPTED MANUSCRIPT Measurement of high-T and high-P absorption spectra 2 .5 %
C 2
H 4
2 .0
/A r, 1 6 2 5 K , 1 .7 1 a tm
W a v e n u m b e r [c m 1 1 7 6 .5
T e s t T im e : 3 .0 m s
0 .1
0 .5
M ir C A T L a s e r A b s o r b a n c e C O 2 L a s e r A b s o rb a n c e
0 .0 0
1
2
T e m p e ra tu re P re s s u re 3
4
5
/m o l]
1 .0
9 5 2 .4
9 4 3 .4
9 3 4 .6
1 0 .3
1 0 .4
1 0 .5
1 0 .6
1 0 .7
C 2
H
0 .6
0 .3
0 .5
0 .0
M ir C A T L a s e r A b s o r b a n c e C O 2 L a s e r A b s o rb a n c e 0
2
4
T e m p e ra tu re P re s s u re 6
8
0 .0 1 0
T im e [m s ]
Fig. 4 Absorbance of C2 H4 as measured by a rapid-tuning
498 499 500 501 502 503 504 505 506 507 508 509 510 511 512
PT
ED
497
CE
496
the effects of decomposition on the test gas temperature time-history [22]. Finally, C2 H4 is relevant to a number of areas of research concerned with high-temperature gases. In hightemperature combustion chemistry C2 H4 is a key intermediate species from fuel pyrolysis and significantly influences subsequent oxidation chemistry [40, 41]. Similarly, C2 H4 is a pyrolysis product of many modern ablative thermal protection systems for atmospheric entry vehicles and influences boundary layer flow fields, kinetics, and radiation [42–44]. Moreover, C2 H4 is a constituent of the atmosphere of many substellar objects such as brown dwarfs, gas giants, and super-earths [45,46]. In all of these fields, improved high-temperature C2 H4 spectroscopic data will enable better diagnostic tools and improved understanding of foundational phenomena. Figure 5 presents a comparison of the measured absorption cross section of C2 H4 at 995 K and 2.28 atm to predictions by HITRAN 2016 and the model by Rey et
AC
495
0 -3 0
R e s id u a l =
-6 0 8 .5
9 .0
9 .5
W
1 0 .0
a
v e
1 0 .5
l e
n
g
t h
[ μ
1 1 .0
m
R e y e t a l.
-
M e a s.
M e a s.
1 1 .5
×1 0 0 %
1 2 .0
]
Fig. 5 Comparison of the C2 H4 absorption cross section measured at 995 K and 2.28 atm with predicted values from
HITRAN 2016 and the model by Rey et al. for temperatures up to 700 K [8, 12]. The inset provides a detailed view of the ν7 vibrational band peak near 10.532 µm.
al. for temperatures up to 700 K [8, 12]. The measured spectrum is a concatenation of three shock tube experiments in order to span the full wavelength coverage range of both EC-QCL modules (865 cm−1 to 920 cm−1 , 926 cm−1 to 1089 cm−1 , and 1071 cm−1 to 1178 cm−1 , note the gap in laser coverage near 920 cm−1 ). The variation in the temperature and pressure of the test conditions for the three experiments was ±5 K and ±0.02 atm, respectively. The results demonstrate the shortcomings of applying a room-temperature database, such as HITRAN 2016, at elevated temperatures. The lack of highJ rovibrational transitions leads to a significant underprediction of the strength and breadth of prominent features. Additionally, new spectral peaks that emerge at high temperatures, such as those neighboring the primary peak near 10.532 µm, are missing from the predicted spectra due to the absence of vibrational hot bands from the database. The accuracy of the Rey et al. 700 K model is considerably better at predicting both the cross section amplitude and the discrete high-temperature features within the spectrum. This database incorporates hot bands and a rotational quantum number cutoff of J = 71. This cutoff is sufficient for a fully convergent rotational partition function, and thus a complete line list, for spectrum predictions up to 700 K. However, as stated by Rey et al., a rotational quantum number cutoff of
M
EC-QCL during a low-temperature test condition (Bottom: 811 K; 1.91 atm; 1.0 % C2 H4 /Ar) and a high-temperature test condition (Top: 1625 K; 1.71 atm; 2.5 % C2 H4 /Ar). C2 H4 absorbance simultaneously measured by a fixed-wavelength CO2 gas laser at 949.49 cm−1 (10.532 µm). Measured pressure timehistories, calculated temperatures time-histories, and serviceable test times are also presented for each shock.
494
3 0
AN US
1 .0
T e m p e ra tu re /1 0 0 0 [K ] P re s s u re [a tm ]
A b s o rb a n c e
0 .9
8 3 3 .3
0
5
0
1 .2
8 6 9 .6
5
2 .0
1 .5
9 0 9 .1
E x p : 9 9 5 ± 5 K , 2 .2 8 ± 0 .0 2 a tm R e y e t a l.: 9 9 5 K , 2 .2 8 a tm H IT R A N : 9 9 5 K , 2 .2 8 a tm
1 0
/A r, 8 0 3 K , 1 .8 7 a tm 4
]
1 0
6
R e s id u a l [% ]
1 %
-1
9 5 2 .4
9 6 1 .5
0 .0
T e s t T im e : 8 .6 m s
1 0 0 0 .0
9 7 0 .9
T im e [m s ] 1 .5
1 0 5 2 .6
1 5
2
0 .2
1 5
C r o s s S e c tio n [m
1 .5
T e m p e ra tu re /1 0 0 0 [K ] P re s s u re [a tm ]
A b s o rb a n c e
0 .3
1 1 1 1 .1
CR IP T
0 .4
7
513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539
ACCEPTED MANUSCRIPT C. L. Strand1 et al.
8 -1
W a v e n u m b e r [c m 1 1 1 1 .1
1 0 5 2 .6
]
1 0 0 0 .0
W a v e n u m b e r [c m 9 5 2 .4
1 0 5 2 .6
1 0 2 5 .6
-1
1 0 0 0 .0
]
9 7 5 .6
9 5 2 .4
2 5 9 6 1 .5
9 5 6 .9
9 5 2 .4
9 4 7 .9
9 4 3 .4
9 6 1 .5
1 5
9 5 2 .4
9 4 3 .4
9 3 4 .6
a tm 1 a tm 5 a tm 4 a tm 0 a tm
1 0 5
1 0 0
1 0 .4 0
1 0 .4 5
1 0 0 1 0 0 1 0 0 1 0 1
1 5
/m o l]
1 .9 1 , 2 .3 , 2 .1 , 1 .8 , 1 .7
2
1 5 1 5
K , 0 K 1 K 5 K 2 K
1 0 .5 0
1 0 .5 5
1 0 .6 0
1 0
9 .5 W
1 0 .0 a
v e
l e
n
g
t h
[ μ
m
1 0 .5
5 1 0 .4
9 .5 0
]
546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571
1 0 .7
9 .7 5
1 0 .0 0
a
v e
l e
n
g
1 0 .2 5
t h
[ μ
m
1 0 .5 0
]
Fig. 7 C2 H4 absorption cross section measured over a range of pressure from 1.01 atm to 5.08 atm near 1000 K. The inset provides a detailed view of the ν7 vibrational band peak near 10.532 µm with individual measurement wavelengths indicated
by data markers.
peratures. 1622 K was the only temperature for which appreciable decomposition was observed with a corresponding temperature drop of 4.1 % over the duration of the test time. All other conditions experienced minimal decomposition with less than 0.6 % temperature drop over the duration of the test time. As expected, significant weakening of the absorption cross section and smoothing of individual features was observed with increasing temperature. In Figure 7, four pressures from 1 atm to 5 atm were measured near 1000 K. These results demonstrate the relative pressure insensitivity of the spectra at high temperatures. Prominent spectral features were smoothed with increasing pressure but the local absorption strength remains largely unchanged. This indicates that small variations in pressure during the shock tube test time or between experiments have little effect on the observed spectra.
M
545
ED
544
PT
543
CE
542
J = 80 − 85 would be required for spectrum predictions at 1000 K [12]. The result of the missing lines with higher rotational numbers presumably bears out in comparisons to the measurements where the residual is observed to be predominantly negative. These missing lines may also account for the observation that the integrated cross section of the model over the measurement wavelength range of 864.9 cm−1 to 1178.2 cm−1 is 13.6 % smaller than that of the measurements. Overall, the model is a substantial improvement over those previously available and in this high-temperature case provides predictions with a residual generally less than ±30 % relative to the measured cross section. Measurements of the C2 H4 absorption cross section were performed at a range of temperatures and pressures presented in Figures 6 and 7, respectively. The spectra presented in these figures each represent a single shock tube experiment; however, multiple repeated experiments were performed to ensure consistency in the observed spectra. The inset in each figure provides a detailed view of the fundamental ν7 vibrational band. The data markers within each inset indicate the individual measurement wavelengths and highlight the approximately 0.35 cm−1 spectral interval of the measurements. In Figure 6, five temperatures from 811 K to 1622 K were measured near 2 atm. The available test time in a shock tube is inversely related to the test gas temperature. Correspondingly, the available scan range in a single experiment is reduced with increasing temperature. This can be observed in the figure. As discussed in Section 2.5, decomposition is a concern at high tem-
AC
541
1 0 .6
AN US
of temperatures from 811 K to 1622 K near 2 atm. The inset provides a detailed view of the ν7 vibrational band peak near 10.532 µm with individual measurement wavelengths indicated by data markers.
540
1 0 .5
W
Fig. 6 C2 H4 absorption cross section measured over a range
1 a tm 1 a tm 3 a tm 8 a tm
5
0
9 .0
1 .0 2 .3 3 .1 5 .0
1 0
5
0
5 K , 0 K , 4 K , 3 K ,
CR IP T
C r o s s S e c tio n [m
8 1 1 1 0 0 1 2 0 1 3 7 1 6 2
2 0
C r o s s S e c tio n [m
2 0
2
/m o l]
2 5
3.2 Illustrative Spectra In addition to the measurement of the C2 H4 absorption cross section at a range of temperatures and pressures, the methodology was applied to several additional species as an illustration of the potential of this approach to generate a new database of high-temperature absorption spectra. Figure 8 presents measurements of the absorption cross sections of propene (C3 H6 ), 1-butene (1-C4 H8 ), 2-butene (2-C4 H8 ), 1,3-butadiene (1,3-C4 H6 ), and methanol (CH3 OH) near 1000 K and 2.3 atm. In general, the current approach may be applied
572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589
590
591 592 593 594 595 596 597 598 599 600
ACCEPTED MANUSCRIPT Measurement of high-T and high-P absorption spectra
1 0 5 2 .6
1 0 0 0 .0 p ro 1 -b 2 -b 1 ,3 m e
7 .5
p e n e , 1 0 1 5 u te n e , 1 0 0 0 u te n e , 1 0 0 0 - b u ta d ie n e , th a n o l, 1 0 2 0
K , 2 .2 K , 2 .3 K , 2 .3 1 0 2 5 K K , 2 .3
methodology to be applied to maximum temperatures and pressures in excess of 10 000 K and 1000 atm. In use, quantitative high-temperature absorption spectra over a wide range of wavelengths could service a need for validation targets in the development of high-temperature empirical and ab intio spectral models (emission and absorption). Additionally, the data could be employed in the interpretation of spectroscopic observations and the development of laser absorption spectroscopy sensors. Overall, the methodology presented here provides an avenue to significantly expand upon existing experimental spectroscopic databases with a new range of previously impractical temperatures and pressures.
] 9 0 9 .1
8 6 9 .6
a tm a tm a tm , 2 .3 a tm a tm
C r o s s S e c tio n [m
2
/m o l]
1 0 .0
-1
9 5 2 .4
5 .0
2 .5
0 .0 9 .0
9 .5
1 0 .0 W
a
v e
1 0 .5 l e
n
g
t h
[ μ
1 1 .0 m
1 1 .5
]
Fig. 8 Absorption cross section measurements for multiple il-
607
608
609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631
References
M
606
4 Summary
ED
605
A methodology has been developed for the measurement of quantitative absorption cross sections for hightemperature and high-pressure gases. The approach leverages the recent development of rapid-tuning, broadscan EC-QCLs to take advantage of the short-duration near-ideal high-enthalpy test conditions generated by a shock tube test facility. Absorption cross section measurements of the ν7 fundamental vibrational band of C2 H4 from 8.5 µm to 11.7 µm were performed over the temperature range 811 K to 1622 K and the pressure range 1 atm to 5 atm. Additionally, to illustrate the broad range of application, absorption cross section measurements for propene, 1butene, 2-butene, 1,3-butadiene, and methanol near 1000 K and 2.3 atm were presented. Using presently available rapid-tuning, broad-scan EC-QCL systems, the methodology is applicable to any infrared-active species with absorption in the wavelength range of approximately 4 µm to 12 µm. This range of wavelengths is rapidly expanding with emerging laser technologies and full coverage of the molecular rovibrational spectrum with broadband, rapid-tuning lasers is anticipated. Shock tubes conceivably permit this
PT
604
CE
603
to any infrared-active species under conditions where the salient features may be resolved by the spectral interval of the laser tuning. However, future developments in rapid-tuning, broad-scan laser systems will inevitably reduce the spectral interval, increase the tuning rate, and open new wavelength ranges enabling a greater range of species and conditions.
AC
602
Acknowledgements This material is based upon work supported by, or in part by, the U. S. Army Research Laboratory and the U. S. Army Research Office under contract/grant number W911NF-17-1-0420. Additionally, this work was supported by the Air Force Office of Scientific Research through AFOSR Grant No. FA9550-16-1-0195, with Dr. Chiping Li as contract monitor.
AN US
lustrative species (propene, 1-butene, 2-butene, 1,3-butadiene, and methanol) near 1000 K and 2.3 atm
601
CR IP T
W a v e n u m b e r [c m 1 1 1 1 .1
9
1. J. Tennyson, S. N. Yurchenko, A. F. Al-Refaie, E. J. Barton, K. L. Chubb, P. A. Coles, S. Diamantopoulou, M. N. Gorman, C. Hill, A. Z. Lam, L. Lodi, L. K. McKemmish, Y. Na, A. Owens, O. L. Polyansky, T. Rivlin, C. Sousa-Silva, D. S. Underwood, A. Yachmenev, and E. Zak, “The ExoMol database: Molecular line lists for exoplanet and other hot atmospheres,” J. Mol. Spectrosc., vol. 327, pp. 73–94, 2016. 2. A. Coustenis, A. V. Boudon, R. G. Campargue, and V. G. Tyuterev., “Exo-PlanetarY high-Temperature Hydrocarbons by Emission and Absorption Spectroscopy (the ePYTHEAS project),” in Eur. Planet. Sci. Congr. 2017, vol. 11, 2017. 3. L. Rothman, I. Gordon, R. Barber, H. Dothe, R. Gamache, A. Goldman, V. Perevalov, S. Tashkun, and J. Tennyson, “HITEMP, the high-temperature molecular spectroscopic database,” J. Quant. Spectrosc. Radiat. Transf., vol. 111, pp. 2139–2150, oct 2010. 4. Z. Bacsik, J. Mink, and G. Keresztury, “FTIR Spectroscopy of the Atmosphere Part 2. Applications,” Appl. Spectrosc. Rev., vol. 40, pp. 327–390, nov 2005. 5. P. Francis, A. Maciejewski, C. Oppenheimer, and C. Chaffin, “New methods make volcanology research less hazardous,” Eos (Washington. DC)., vol. 77, no. 41, pp. 393+396–397, 1996. 6. C. S. Goldenstein, R. M. Spearrin, J. B. Jeffries, and R. K. Hanson, “Infrared laser-absorption sensing for combustion gases,” Prog. Energy Combust. Sci., vol. 60, pp. 132–176, 2017. 7. R. K. Hanson, “Applications of quantitative laser sensors to kinetics, propulsion and practical energy systems,” Proc. Combust. Inst., vol. 33, no. 1, pp. 1–40, 2011. 8. I. E. Gordon, L. S. Rothman, C. Hill, R. V. Kochanov, Y. Tan, P. F. Bernath, M. Birk, V. Boudon, A. Campargue, K. V. Chance, B. J. Drouin, J.-M. Flaud, R. R. Gamache, J. T. Hodges, D. Jacquemart, V. I. Perevalov,
632 633 634 635 636 637 638 639 640 641 642 643 644 645
646 647 648 649 650 651 652
653
654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689
ACCEPTED MANUSCRIPT C. L. Strand1 et al.
10
697 698 699 700 701 702
9.
703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718
10.
719 720 721 722
11.
723 724 725 726
12.
727 728 729 730 731 732
13.
733 734 735
14.
736 737 738 739
15.
740 741 742
16.
743 744 745 746 747
17.
748 749 750 751
18.
752 753 754 755 756
19.
CR IP T
696
AN US
695
20. G. L. Pilla, D. F. Davidson, and R. K. Hanson, “Shock tube/laser absorption measurements of ethylene timehistories during ethylene and n-heptane pyrolysis,” Proc. Combust. Inst., vol. 33, no. 1, pp. 333–340, 2011. 21. W. Ren, D. F. Davidson, and R. K. Hanson, “IR laser absorption diagnostic for C2H4 in shock tube kinetics studies,” Int. J. Chem. Kinet., vol. 44, no. 6, pp. 423–432, 2012. 22. W. K. Metcalfe, S. M. Burke, S. S. Ahmed, and H. J. Curran, “A hierarchical and comparative kinetic modeling study of C1- C2 hydrocarbon and oxygenated fuels,” Int. J. Chem. Kinet., vol. 45, no. 10, pp. 638–675, 2013. 23. N. Dam, R. Engeln, J. Reuss, A. S. Pine, and A. Fayt, “Ethylene hot bands from molecular jet double-resonance spectroscopy,” J. Mol. Spectrosc., vol. 139, no. 1, pp. 215– 235, 1990. 24. B. R. Georges, M. Bach, and M. Herman, “High resolution FTIR spectroscopy using a slit jet: Sampling the overtone spectrum of12C2H4,” Mol. Phys., vol. 90, no. 3, pp. 381– 388, 1997. 25. B. G. Sartakov, J. Oomens, J. Reuss, and A. Fayt, “Interaction of Vibrational Fundamental and Combination States of Ethylene in the 3 µm Region,” J. Mol. Spectrosc., vol. 185, no. 1, pp. 31–47, 1997. 26. M. Bach, R. Georges, M. Hepp, and M. Herman, “Slit-jet Fourier transform infrared spectroscopy in 12C2H4: cold and hot bands near 3000 cm1,” Chem. Phys. Lett., vol. 294, no. 6, pp. 533–537, 1998. 27. M. Bach, R. Georges, M. Herman, and A. Perrin, “Investigation of the fine structure in overtone absorption bands of 12C2H4,” Mol. Phys., vol. 97, no. 1-2, pp. 265–277, 1999. 28. W. E. Blass, J. J. Hillman, A. Fayt, S. J. Daunt, L. R. Senesac, A. C. Ewing, L. W. Jennings, J. S. Hager, S. L. Mahan, D. C. Reuter, and M. Sirota, “10 µm ethylene: Spectroscopy, intensities and a planetary modeler’s atlas,” J. Quant. Spectrosc. Radiat. Transf., vol. 71, no. 1, pp. 47– 60, 2001. 29. G. Blanquet, J. P. Bouanich, J. Walrand, and M. Lep` ere, “Diode-laser measurements and calculations of N2broadening coefficients in the ν 7 band of ethylene,” J. Mol. Spectrosc., vol. 229, no. 2, pp. 198–206, 2005. 30. M. Rotger, V. Boudon, and J. Vander Auwera, “Line positions and intensities in the ν 12 band of ethylene near 1450 cm- 1: An experimental and theoretical study,” J. Quant. Spectrosc. Radiat. Transf., vol. 109, no. 6, pp. 952– 962, 2008. 31. O. N. Ulenikov, G. A. Onopenko, E. S. Bekhtereva, T. M. Petrova, A. M. Solodov, and A. A. Solodov, “High resolution study of the ν 5 + ν 12 band of C2H4,” Mol. Phys., vol. 108, no. 5, pp. 637–647, 2010. 32. M. A. Loro˜ no Gonzalez, V. Boudon, M. Lo¨ ete, M. Rotger, M. T. Bourgeois, K. Didriche, M. Herman, V. A. Kapitanov, Y. N. Ponomarev, A. A. Solodov, A. M. Solodov, and T. M. Petrova, “High-resolution spectroscopy and preliminary global analysis of C-H stretching vibrations of C2H4 in the 3000 and 6000cm-1 regions,” J. Quant. Spectrosc. Radiat. Transf., vol. 111, no. 15, pp. 2265–2278, 2010. 33. J. M. Flaud, W. J. Lafferty, R. Sams, and V. Malathy Devi, “High resolution analysis of the ethylene-1-13C spectrum in the 8.4-14.3 µm region,” J. Mol. Spectrosc., vol. 259, no. 1, pp. 39–45, 2010. 34. J. M. Flaud, W. J. Lafferty, V. Malathy Devi, R. L. Sams, and D. Chris Benner, “Absolute line intensities and selfbroadened half-width coefficients in the ethylene-1-13C
M
694
ED
693
PT
692
A. Perrin, K. P. Shine, M.-A. H. Smith, J. Tennyson, G. C. Toon, H. Tran, V. G. Tyuterev, A. Barbe, A. G. Cs´ asz´ ar, V. M. Devi, T. Furtenbacher, J. J. Harrison, J.-M. Hartmann, A. Jolly, T. J. Johnson, T. Karman, I. Kleiner, A. A. Kyuberis, J. Loos, O. M. Lyulin, S. T. Massie, S. N. Mikhailenko, N. Moazzen-Ahmadi, H. S. P. M¨ uller, O. V. Naumenko, A. V. Nikitin, O. L. Polyansky, M. Rey, M. Rotger, S. W. Sharpe, K. Sung, E. Starikova, S. A. Tashkun, J. V. Auwera, G. Wagner, J. Wilzewski, P. Wcislo, S. Yu, and E. J. Zak, “The HITRAN2016 molecular spectroscopic database,” J. Quant. Spectrosc. Radiat. Transf., vol. 14, pp. 0–1, 2017. N. Jacquinet-Husson, R. Armante, N. A. Scott, A. Ch´ edin, L. Cr´ epeau, C. Boutammine, A. Bouhdaoui, C. Crevoisier, V. Capelle, C. Boonne, N. Poulet-Crovisier, A. Barbe, D. Chris Benner, V. Boudon, L. R. Brown, J. Buldyreva, A. Campargue, L. H. Coudert, V. M. Devi, M. J. Down, B. J. Drouin, A. Fayt, C. Fittschen, J. M. Flaud, R. R. Gamache, J. J. Harrison, C. Hill, Hodnebrog, S. M. Hu, D. Jacquemart, A. Jolly, E. Jim´ enez, N. N. Lavrentieva, A. W. Liu, L. Lodi, O. M. Lyulin, S. T. Massie, S. Mikhailenko, H. S. M¨ uller, O. V. Naumenko, A. Nikitin, C. J. Nielsen, J. Orphal, V. I. Perevalov, A. Perrin, E. Polovtseva, A. Predoi-Cross, M. Rotger, A. A. Ruth, S. S. Yu, K. Sung, S. A. Tashkun, J. Tennyson, V. G. Tyuterev, J. Vander Auwera, B. A. Voronin, and A. Makie, “The 2015 edition of the GEISA spectroscopic database,” J. Mol. Spectrosc., vol. 327, no. June, pp. 31–72, 2016. S. W. Sharpe, T. J. Johnson, R. L. Sams, P. M. Chu, G. C. Rhoderick, and P. A. Johnson, “Gas-phase databases for quantitative infrared spectroscopy,” Appl. Spectrosc., vol. 58, no. 12, pp. 1452–1461, 2004. P. M. Chu, F. R. Guenther, G. C. Rhoderick, and W. J. Lafferty, “The NIST Quantitative Infrared Database,” J. Res. Natl. Inst. Stand. Technol., vol. 104, no. 1, pp. 59–81, 1999. M. Rey, T. Delahaye, A. V. Nikitin, and V. G. Tyuterev, “First theoretical global line lists of ethylene (12C2H4) spectra for the temperature range 50-700 K in the farinfrared for quantification of absorption and emission in planetary atmospheres,” Astron. Astrophys., vol. 594, no. A47, pp. 1–16, 2016. J. Tennyson and S. N. Yurchenko, “Laboratory spectra of hot molecules: Data needs for hot super-Earth exoplanets,” Mol. Astrophys., vol. 8, pp. 1–18, 2017. M. A. Oehlschlaeger, D. F. Davidson, and R. K. Hanson, “High-temperature thermal decomposition of isobutane and n-butane behind shock waves,” J. Phys. Chem. A, vol. 108, no. 19, pp. 4247–4253, 2004. T. C. Parise, D. Davidson, and R. K. Hanson, “Development of a two-wavelength IR laser absorption diagnostic for propene and ethylene,” Meas. Sci. Technol., 2018. A. Farooq, J. B. Jeffries, and R. K. Hanson, “Sensitive detection of temperature behind reflected shock waves using wavelength modulation spectroscopy of CO2 near 2.7 µm,” Appl. Phys. B Lasers Opt., vol. 96, no. 1, pp. 161– 173, 2009. Z. Hong, G. A. Pang, S. S. Vasu, D. F. Davidson, and R. K. Hanson, “The use of driver inserts to reduce nonideal pressure variations behind reflected shock waves,” Shock Waves, vol. 19, no. 2, pp. 113–123, 2009. Z. Hong, D. F. Davidson, and R. K. Hanson, “Contact surface tailoring condition for shock tubes with different driver and driven section diameters,” Shock Waves, vol. 19, no. 4, pp. 331–336, 2009. P. Buerki and M. Weida, “CW Tuning Behavior of CWPLS Lasers,” tech. rep., Daylight Solutions, Inc., 2008.
CE
691
AC
690
757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822
ACCEPTED MANUSCRIPT
829
36.
830 831 832
37.
833 834 835 836
38.
837 838 839 840
39.
841 842 843 844 845 846
40.
847 848 849 850 851 852
41.
853 854 855 856 857
42.
858 859 860
43.
861 862 863 864 865
44.
866 867 868 869
45.
870 871 872 873 874 875 876
46.
AN US
828
M
827
ED
35.
826
PT
825
bands in the 700-1190 cm-1 region,” J. Mol. Spectrosc., vol. 267, no. 1-2, pp. 3–12, 2011. W. J. Lafferty, J. Flaud, and F. K. Tchana, “The highresolution infrared spectrum of ethylene in the 1800 2350 cm spectral region,” Mol. Phys., vol. 109, no. 21, pp. 2501–2510, 2011. G. B. Lebron and T. L. Tan, “Integrated Band Intensities of Ethylene (12C2H4) by Fourier Transform Infrared Spectroscopy,” Int. J. Spectrosc., vol. 2012, pp. 1–5, 2012. A. Ben Hassen, F. Kwabia Tchana, J. M. Flaud, W. J. Lafferty, X. Landsheere, and H. Aroui, “Absolute line intensities for ethylene from 1800 to 2350 cm-1,” J. Mol. Spectrosc., vol. 282, no. 1, pp. 30–33, 2012. M. Alrefae, E. T. Es-Sebbar, and A. Farooq, “Absorption cross-section measurements of methane, ethane, ethylene and methanol at high temperatures,” J. Mol. Spectrosc., vol. 303, pp. 8–14, 2014. J. Vander Auwera, A. Fayt, M. Tudorie, M. Rotger, V. Boudon, B. Franco, and E. Mahieu, “Self-broadening coefficients and improved line intensities for the ν 7 band of ethylene near 10.5 µm, and impact on ethylene retrievals from Jungfraujoch solar spectra,” J. Quant. Spectrosc. Radiat. Transf., vol. 148, pp. 177–185, 2014. R. Xu, D. Chen, K. Wang, Y. Tao, J. K. Shao, T. Parise, Y. Zhu, S. Wang, R. Zhao, D. J. Lee, F. N. Egolfopoulos, D. F. Davidson, R. K. Hanson, C. T. Bowman, and H. Wang, “HyChem model: Application to petroleumderived jet fuels,” 10th U.S. Natl. Combust. Meet., pp. 1–6, 2017. R. Xu, H. Wang, D. F. Davidson, R. K. Hanson, C. T. Bowman, and F. N. Egolfopoulos, “Evidence supporting a simplified approach to modeling high-temperature combustion chemistry,” 10th U.S. Natl. Combust. Meet., pp. 1–6, 2017. K. A. Lincoln, “Experimental Determination of Vapor Species from Laser-Ablated Carbon Phenolic Composites,” AIAA, vol. 21, no. 8, pp. 1204–1207, 1983. A. Martin, I. Boyd, I. Cozmuta, and M. Wright, “Chemistry Model for Ablating Carbon-Phenolic Material During Atmospheric Re-Entry,” 48th AIAA Aerosp. Sci. Meet. Incl. New Horizons Forum Aerosp. Expo., no. January, 2010. B. Helber, O. Chazot, T. Magin, and A. Hubin, “Space and Time-Resolved Emission Spectroscopy of Carbon Phenolic Ablation in Air and Nitrogen Plasmas,” 44th AIAA Thermophys. Conf., pp. 1–14, 2013. K. Lodders and B. Fegley, “Atmospheric chemistry in giant planets, brown dwarfs, and low-mass dwarf stars. I. Carbon, nitrogen, and oxygen,” Icarus, vol. 155, no. 2, pp. 393–424, 2002. R. Hu and S. Seager, “Photochemistry in terrestrial exoplanet atmospheres. III. Photochemistry and thermochemistry in thick atmospheres on super earths and mini neptunes,” Astrophys. J., vol. 784, no. 1, 2014.
CE
824
AC
823
11
CR IP T
Measurement of high-T and high-P absorption spectra