Mutagenic activity of BC and 4CMB in the Salmonella spot test

Mutagenic activity of BC and 4CMB in the Salmonella spot test

Mutation Research, 100 (1982) 17-19 17 Elsevier Biomedical Press MUTAGENIC ACTIVITY OF BC AND 4CMB IN THE S A L M O N E L L A SPOT TEST F...

78KB Sizes 3 Downloads 50 Views

Mutation Research, 100 (1982) 17-19

17

Elsevier Biomedical Press

MUTAGENIC

ACTIVITY

OF BC AND

4CMB

IN

THE

S A L M O N E L L A

SPOT

TEST

F. H Y L D I G - N I E L S E N l and B. H A R T L E Y - A S P 2

Microbiology Department, H. Lundbeck and Co., Valby, DK-2500 Copenhagen I (Denmark) and Pharmacology Department, AB Leo, S-251 09 Helsingborg2 (Sweden) (Received 16 April 1981) (Accepted 23 June 1981)

The Salmonella

s p o t t e s t is t h e s i m p l e s t w a y t o t e s t s u b s t a n c e s

as several concentrations

sitive than the plate test and therefore should

be considered

for mutagenicity,

c a n b e s c r e e n e d p e r p l a t e . It h a s b e e n r e g a r d e d

as adequate

only a large increase in the number

evidence

as less senof colonies

for mutagenicity.

TABLE 1 M U T A G E N I C A C T I V I T Y OF 4CMB A N D BC AS I N D I C A T E D BY T H E S A L M O N E L L A SPOT TEST Compound

2-Aminoanthracene

Benzylchloride

aConc.

Strain

~g/ml)

TA1535

TA1537

TA1538

+$9

+$9

+$9

-$9

+ + + + ++

--

+ + +

--

+++

--

+ + +

--

+ + +

--

+ + +

--

+ + +

2 20 40 10 1 000 10000

-$9

+ + + + +

-

-$9

+ +

-

TA98

TAI00

+$9

-$9

+$9

} .

.

. . . . .

. . . . .

.

.

.

.

.

-$9

b

.

100 1000 4CMB

1 100 10000 10 1000

.

.

. .

. .

. .

.

. +

. .

.

. . +

a2 or 3 concentrations per plate. b The effect o f the single discs cannot be read (see discussion).

0165-1218/82/0000-0000/$02.75 © Elsevier Biomedical Press

. ? + ? +

.

. + . +

. ? + .

. +

+

+

+

+

.

18 MATERIALS AND METHODS T h e s p o t test was c a r r i e d o u t a c c o r d i n g t o A m e s et al. (1975). B C was d i l u t e d in e t h a n o l a n d 4 C M B d i s s o l v e d a n d d i l u t e d in D M S O . 2 0 / z l o f t h e s o l u t i o n s w e r e i m b i b e d i n t o 6 m m p a p e r discs ( S c h l e i c h e r a n d S c h 0 e l l N o . 2668). T h e c o n c e n t r a t i o n , i n d i c a t e d in the t a b l e s , is t h e c o n c e n t r a t i o n o f the c o m p o u n d in t h e s o l v e n t , i m b i b e d in t h e disc. I n E x p t . 1, 2 o r 3 discs ( o n e disc p e r c o n c e n t r a t i o n ) h a v e b e e n a p p l i e d o n e a c h p e t r i d i s h ( T a b l e 1). In E x p t . 2 o n l y o n e disc was a p p l i e d per p e t r i dish ( T a b l e 2). DISCUSSION O n e o f t h e s u b s t a n c e s in this s t u d y (BC) is n o t s u i t a b l e f o r t e s t i n g in m o r e t h a n o n e c o n c e n t r a t i o n p e r p l a t e w i t h this m e t h o d as t h e r e v e r t a n t c o l o n i e s a r e s p r e a d e v e n l y o v e r t h e w h o l e p l a t e b l u r r i n g t h e i n f l u e n c e f r o m t h e discs o f l o w e r c o n c e n t r a t i o n s . T h i s e f f e c t is p o s s i b l y d u e t o a v a p o u r f r o m t h e s u b s t a n c e s p r e a d b e t w e e n t h e lid a n d t h e s u r f a c e o f t h e a g a r .

TABLE 2 THE NUMBER OF REVERTANTS FOUND AFTER TREATMENT WITH BC AND 4CMB IN THE SALMONELLA SPOT TEST Compound

Conc.

Strain

(~g/ml)

Benzylchloride

4CMB

- $9

23 40 10 100 1 000 10 000 100 000 1

10 100 1 000 10 000 ND, not done. Inhibition of background lawn.

a

TA98

+ $9 Control 2-Aminoanthracene

TA1538

TAIO0

+ $9

- $9

+ $9

- $9

19

52

33

193

136

+ +

12

+ + +

33

+ + +

132

ND ND ND ND 43

ND ND ND ND 14

62 46 54 61 61

23 21 32 28 34

150 152 152 188 1000a

139 145 131 156 452a

34 28 36a 72a 125a

14 20 131a 468a 846a

40 47 59a 90a 145a

28 43 96 350 574a

155 136 185 288a 494a

129 111 162 273 476a

19 CONCLUSIONS 4CMB exhibited rnutagenic activity in TA1538, TA98 and TA100 whereas BC was only active in T A 1 0 0 . 4 C M B was active at a lower concentration than BC in TA100. Thus, 4CMB exhibits a higher mutagenic potential than BC in the Salmonella typhimurium spot test. REFERENCE Ames, B.N., J. McCann and E. Yamasaki (1975) Methods for detecting carcinogensand mutagens with the Salmonella/mammalian-microsomemutagenicity test, Mutation Res., 31,347-364.