Letter to the Editor Reply to “Letter to the Editor” by J.C. Jones Dear Editor, These are the answers to the questions asked by Dr J.C. Jones for the paper “Statistical Modelling of Stockpile Behaviour under Different Atmospheric Conditions—Wetern Lignite Corporation Case” First of all, the resistance temperature detector we used in this work is three-wire configuration and the technical characteristics of the RTS are given in Figs. 1 and 2.
Fig. 2. Resistance–temperature diagram of Pt100.
The reason why the moving average filter was used is to remove the pick-up effects with high frequency concealing the signals with very low frequencies supposed to be coming from the measurement stations. Moreover, in order to obtain reliable measurements, the Wheatstone arrangement with constant current source was used. Cem Sensogut* Department of Mining Engineering, Dumlupinar University, Muhendislik Fak. Merkez Kampus, 43100 Kutahya, Turkey E-mail address: