Silicone-based simulation models for peripheral nerve microsurgery Burcin Ustbas Gul PhD , Deniz Kilic Yanilmaz MSc , Dilan Arslan BSc , Mehmet Bayramicli PROF , Ozge Akbulut ASST. PROF PII: DOI: Reference:
S1748-6815(18)30389-9 https://doi.org/10.1016/j.bjps.2018.10.025 PRAS 5839
To appear in:
Journal of Plastic, Reconstructive & Aesthetic Surgery
Received date: Accepted date:
23 July 2018 28 October 2018
Please cite this article as: Burcin Ustbas Gul PhD , Deniz Kilic Yanilmaz MSc , Dilan Arslan BSc , Mehmet Bayramicli PROF , Ozge Akbulut ASST. PROF , Silicone-based simulation models for peripheral nerve microsurgery, Journal of Plastic, Reconstructive & Aesthetic Surgery (2018), doi: https://doi.org/10.1016/j.bjps.2018.10.025
This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
ACCEPTED MANUSCRIPT
1
Silicone-based Simulation Models for Peripheral Nerve Microsurgery
2 3
Burcin Ustbas Gul, PhD.1, Deniz Kilic Yanilmaz, MSc.2, Dilan Arslan, BSc.3,
4
Mehmet Bayramicli, PROF.4, and Ozge Akbulut, ASST. PROF.1
6
1
7
2
8
3
9
4
Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul, Turkey. Surgitate Medikal Arge Sanayi ve Ticaret A. S., Kocaeli, Turkey. Chemistry Department, Hacettepe University, Ankara, Turkey.
Department of Plastic, Reconstructive and Aesthetic Surgery, Marmara University
AN US
10
CR IP T
5
Hospital, Istanbul, Turkey.
11
Correspondence
13
Ozge Akbulut.
14
Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul, Turkey.
15
E-mail:
[email protected]
16
PT
ED
M
12
Keywords:
18
Peripheral nerve microsurgery; Simulation models; Silicone-based models.
20 21
AC
19
CE
17
22 23 24
1
ACCEPTED MANUSCRIPT
Abstract
26
Background:
27
There is a need for a peripheral nerve model on which surgeons-in-training can simulate
28
the repair of nerve injuries at their own pace. Although practicing on animal
29
models/cadavers is considered the ―gold standard‖ of microsurgical training, the
30
proposed model aims to provide a platform for improving the technical skills of surgical
31
trainees prior to their practice on cadaver/animal models. In addition, this model has the
32
potential to serve as a standardized test medium for assessing the skill sets of
33
surgeons.
34
Methods:
35
Several formulations of silicone were utilized for the design and fabrication of a model
36
which realizes the hierarchical structure of peripheral nerves. The mechanical properties
37
were characterized via the Universal Testing Machine; the damage caused by the
38
needle on the entry sites was assessed through scanning electron microscopy (SEM).
39
Results:
40
Mechanical properties of the formulations of silicone were tested to mimic human
41
peripheral nerves. A formulation with 83.3 wt % silicone oil and 0.1 wt % cotton fiber
42
was chosen to be used as nerve fascicles. Both 83.3 wt % silicone oil with cotton fiber
43
and 66.6 wt % silicone oil without fiber provided a microsuturing response similar to that
45
AN US
M
ED
PT
CE
AC
44
CR IP T
25
of epineurium at a wall thickness of 1 mm. SEM also confirmed that the entry of the needle did not introduce significant holes at the microsuturing sites.
46
Conclusions:
47
The proposed peripheral nerve model mimicked human tissues mechanically and
48
cosmetically, and a simulation of the repair of a fifth-degree nerve injury was achieved.
2
ACCEPTED MANUSCRIPT
49
1 | INTRODUCTION To ensure improved outcomes for patients, several disciplines such as plastic
51
surgery, neurosurgery, and orthopaedic surgery have integrated microsurgery to their
52
practice [1],[2]. Long-term assessment of recovery of nerve injuries that are repaired
53
through microsurgery indicates a faster healing process and retrieval of sensory and
54
motor functions [3]. Microsurgeons-in-training necessitate intense practice to enhance
55
their surgical competence, proficiency, and dexterity [4], and simulation is taking a
56
growing share in the education of surgeons. Peripheral nerve repair remains a
57
challenge, and several distinct nerve simulation models, from rudimentary gloves to
58
virtual reality platforms, are now utilized to improve the microsurgical skill-sets of
59
doctors [5]. In the tactile realm, working with animal models and cadavers along with
60
live patients is considered the gold standard in medical education [6]. In addition, fresh
61
tissues such as pig leg [7], human placenta [8], and avulsed skin [9] are used as
62
practice media, while surgical gloves and medical grade tubes [6, 10] are also employed
63
as primitive alternatives. However, these models have their limitations: i) access to
64
cadavers and live humans/animals is not constantly available [6]; ii) there are ethical
65
concerns related to working on patients and animal models [11]; iii) fresh tissues
66
necessitate refrigeration and contain a high risk of transmissible diseases; hence, can
68
AN US
M
ED
PT
CE
AC
67
CR IP T
50
be classified as biohazards and require vast amounts of effort for self-protection [12]. Unrealistic synthetic materials such as latex strips and tubes [13], polyethylene [14],
69
Gore-Tex [15] and parafilm [16] do not offer the necessary fragility, complexity, and
70
hierarchical outlook of real tissues. Therefore, there is a need for a realistic, non-
71
hazardous, standardized, and accessible tactile platform for peripheral nerve
3
ACCEPTED MANUSCRIPT
72
microsurgery training. Here, we report on the design of a silicone-based, composite peripheral nerve
74
model. This model can be fabricated in a simple setup (e.g., in a non-chemistry lab) that
75
contains only a scale and an oven. The model consists of: i) a skin layer (i.e., epidermis
76
and subcutaneous fat), ii) peripheral nerves, (i.e., epineurium, connective tissue, and
77
fascicles), and iii) a muscle layer. These components are prepared separately and then
78
combined into a single model. The layers are designed out of two-component silicone
79
elastomers that are formulated to simulate the tactile and cosmetic properties of
80
peripheral nerves. We tracked a matrix of silicone formulations to reach the reported
81
elastic modulus of 3–10 MPa for live tissue [17-19]. Scanning electron microscopy
82
(SEM) indicated no damage upon the entry of a needle while still offering fragility
83
towards microsurgical suturing. This model provides a durable and realistic tactile
84
medium for surgical simulations in which surgeons-in-training can learn at their own
85
pace as well as be examined with a standardized platform.
86
2 | MATERIALS AND METHODS
87
2.1 | Tissue-mimicking Materials
89 90
AN US
M
ED
PT
CE
Two-component liquid silicone elastomer; component A (SL-3358A) and B (SL-
AC
88
CR IP T
73
3358B), were obtained from KCC Corporation, Korea. Silicone oil was purchased from Sapar, Turkey (PMX200-350 CST). Cotton fibers were received from local providers.
91
Dyes that were used in coloring were obtained from Wacker Chemie AG.
92
2.2 | Design of the Peripheral Nerve Model
4
ACCEPTED MANUSCRIPT
The model was prepared according to the human anatomy of the peripheral
94
nervous system [20]. The model aimed to mimic ulnar, median and radial nerves in the
95
upper extremity. Figure 1 demonstrates different layers of the model, which consists of
96
a skin layer, fascia (the connective tissue layers between the skin, nerves, and the
97
muscle layers), and the peripheral nerves (epineurium and fascicles). The simulated
98
epineurium has an inner diameter of 3 mm with a wall thickness of 1 mm. It holds three
99
fascicles which are 1 mm-thick composite structures that contain 0.1 wt % cotton fiber
100
in their formulation. Axons are excluded from the design, since on a benchtop, it would
101
not be possible to fabricate fibers that are 1 μm in diameter.
M
AN US
CR IP T
93
ED
102
FIGURE 1. Different layers of the model
104
2.3 | Preparation of the Model
PT
103
The amount of silicone oil in the formulation spanned a range of 50–83.3 wt % and
106
the remaining weight was equally split between components A and B. The formulations
108
AC
107
CE
105
were prepared by blending the components with a hand mixer, keeping the mixture under vacuum for 30 min, and then curing it at 110 ºC for 30 min. The reaction was
109
addition curing with platinum catalyst and no by-product was observed. Although the
110
curing step can be carried out at room temperature, we utilized higher temperatures to
5
ACCEPTED MANUSCRIPT
111
speed up the process. In addition, the vacuuming step can be eliminated by waiting 2
112
hours for possible air bubbles to leave the system. The formulation for the simulated skin layer was prepared by mixing equal amounts
114
of component A and B with 50 wt % silicone oil. A single, red, sinusoidal line of silicone
115
was deposited on the epineurium to enable the confirmation of successful joining of the
116
broken nerve ends. Cotton and wool natural fibers were further added to the
117
formulations between 0.1–1 wt % to tune the elastic modulus of the epineurium and
118
fascicles. The samples that do not contain fibers are referred to as pristine throughout
119
this study.
AN US
CR IP T
113
Consecutive curing of the muscle layer, fascia layer (before and after the attachment
121
of pre-cured fascicles), subcutaneous fat layer, and the epidermis layer was achieved in
122
a 14×7 cm sized mold. The simulated fascicles were cured in a 3D-printed mold for the
123
precise size and shape match; while thin hoses can also be employed to shape these
124
structures. Any mold that can withstand temperatures around 110 ºC without
125
deformation can be used to prepare the model.
126
2.4 | Mechanical Characterization
PT
ED
M
120
Several formulations of silicone, either pristine specimens or those that contain
128
natural fibers, were prepared in dog-bone shape according to the ASTM (American
130
AC
129
CE
127
Society for Testing and Materials International) standards. The specimens were tested with 200 kN force in the Universal testing machine (UTM), and an average of 4 tests
131
was reported as the test result.
132
2.5 | Scanning Electron Microscopy
6
ACCEPTED MANUSCRIPT
To track the microsuturing performance of the epineurium and the nerve
134
fascicles, the samples were sputter coated with a thin layer of carbon by Cressington
135
carbon coater and mounted onto the carbon tape. Images were acquired by JSM6010-
136
LV scanning electron microscope, with SEI detector, using an electron gun voltage of 5
137
kV.
138
2.6 | Assessment of Microsuturing in the Model
CR IP T
133
The suturing properties of the designed peripheral nerve samples were assessed
140
by one of the authors (M. B.). Samples were tested by 8/0 and 10/0 non-absorbable
141
polypropylene sutures (Prolene) with BV 175-7 and BV 100-4 needle and 11/0 polyester
142
fiber (Mersilene) with TG 160/4 Plus needle (Ethicon Inc., New Jersey, USA), with the
143
aid of an operating microscope (OPMI Vario 700, Carl Zeiss Meditech AG, Germany).
144
3 | RESULTS
145
3.1 | Selection of Materials for the Model
PT
ED
M
AN US
139
For the design of this model, we surveyed a matrix of formulations of silicone
147
since it is commonly used as a tissue-mimicking material in prosthetics [21, 22], the film
148
industry, and soft robotics [23]. The ease of fabrication, molding, and coloring have
149
made silicone a remarkable option for simulation models as well [24]. For instance,
AC
150
CE
146
there are numerous commercially available models (e.g., skin pads) for suturing
151
practice [25]; likewise, silicone tubes have been utilized for microsurgical models [26,
152
27].
7
ACCEPTED MANUSCRIPT
The strength of suturing depends on the elastic modulus of the materials that are
154
used to fabricate epineurium, perineurium, and fascicles [28, 29]. The model is
155
hierarchically structured to offer differing elastic moduli for realistic practice. Our
156
measurements showed the elastic modulus of the samples decreased with increasing
157
silicone oil content (Figure 2). The sample with 83.3 wt % silicone oil exhibited the
158
highest similarity to nerve tissues in terms of elastic modulus (3–10 MPa [17, 30]), and
159
thus, was chosen as the material to form fascicles. The sample that contains 66.6 wt %
160
silicone oil was preferred for the epineurium since this formulation has a higher elastic
161
modulus than the inner connective tissues. The specimens also underwent plastic
162
deformation before fracture (images not shown).
AN US
wt % silicone oil
25
50 66.6
20
10
M
80
15
ED
Elastic Modulus (MPa)
CR IP T
153
83.3
5
PT
0
163
66.6
80
83.3
FIGURE 2. Comparison of elastic modulus of formulations with increasing wt % silicone oil
CE
164
50
For the design of simulated epineurium, we added wool and cotton fibers (0.1 wt
166
%) to the samples that contain 80 and 83.3 wt % silicone oil to further tune the elastic
167 168 169
AC
165
modulus. These fibers facilitate the realistic suturing of the epineurium since they strengthen the medium against tensile forces. Wool and cotton were chosen as reinforcing fibers due to their accessibility at low-cost [31, 32].
8
ACCEPTED MANUSCRIPT
We focused on the elastic modulus at the range of 3–10 MPa [33-37]. The aim
171
was to sustain the fragility of the fibers while asserting traction force on the needle
172
during suturing; thus, we have focused on formulations with low elastic moduli. Since
173
cotton fiber-added samples exhibited relatively smaller values than the wool-added
174
ones, we tracked the change in elastic modulus in cotton-added samples in formulations
175
with 80 and 83.3 wt % silicone oil (Figure 3).
CR IP T
170
177
chosen to be used as the nerve fascicles in the model. Having fibers in the model
178
allowed microsutures on the nerves to remain intact. In brief, utilizing either 83.3 wt %
179
with cotton fibers or 66.6 wt % without fibers can provide microsuturing response similar
180
to that of epineurium at a wall thickness of 1 mm, while the cotton-added sample
181
provides better traction.
14
M
16
AN US
The sample with 83.3 wt % silicone oil that contains 0.1 wt % cotton fiber was
80 wt % Silicone oil
83.3 wt %
12
ED
Elastic Modulus (MPa)
176
10 8
183 184
185
4 2 0 no fiber
0.1 wt % 0.5 wt % Cotton wt %
AC
182
CE
PT
6
1 wt %
FIGURE 3. Comparison of elastic modulus of samples that contain 80 and 83.3 wt % silicone oil with increasing wt % of cotton
3.2 | Evaluation of Microsuturing on the Model
9
ACCEPTED MANUSCRIPT
One of the main obstacles during microsurgery is the damage imposed by the
187
entry of needle to the tissue where bleeding is possible. This bleeding, in turn, may
188
result in the disruption of the area of surgery, and hence, obstruct the vision of a
189
surgeon during the operation. Having smaller damage can also enable a faster healing
190
process after the surgery. Therefore, mechanical properties of the model should allow
191
the entry of the needle without introducing a significant hole that may cause leakage.
CR IP T
186
In order to evaluate the damage around the entry sites of the needle, we have
193
monitored the sutures by SEM. Two different sizes of sutures were utilized for the
194
evaluation of the damage. In Figure 4, 10/0 sutures were used on the formulations of
195
silicone with pristine epineurium models, 0.1 wt % cotton fiber-added epineurium, and
196
the 0.1 wt % cotton fiber-added fascicles. SEM confirms that the sutures inflicted no
197
significant damage at the entry sites and adequately joined the two sides of the
198
epineurium and the fascicles. Figure 5 demonstrates the repairs with 8/0 sutures on the
199
same formulations.
201 202
AC
200
CE
PT
ED
M
AN US
192
FIGURE 4. a) Pristine epineurium model, b) Epineurium model with 0.1 wt % cotton fibers, c) Fascicle model with 0.1 wt % cotton fibers with the utilization of 10/0 sutures.
10
203
CR IP T
ACCEPTED MANUSCRIPT
FIGURE 5. a) Pristine epineurium model, b) Fascicle model with 0.1 wt % cotton fibers, c)
205
Epineurium model with 0.1 wt % cotton fibers with the utilization of 8/0 sutures.
206
3.3 | Microsurgical Assessment of the Model
AN US
204
A fifth-degree peripheral nerve injury was simulated with the model. The anatomy
208
of these nerves was mimicked including the fascia tissue, vasa nervorum, epineurium,
209
connective tissue, and the fascicles. In Figure 6, the nerve model with pristine
210
formulations can be seen. The fascia tissue on the nerves was removed gently (a). A
211
cut on the peripheral nerve was imposed, and the fascicles and connective tissue were
212
observed, blue tissue paper was placed underneath the area of procedure for the ease
213
of visualization (b). Vasa nervorum was aligned on both sides, the fascicles were
214
sutured with 8/0 suture, and the needle was inserted at a 45° angle and removed with
215
circular movements to prevent the generation of excess needle holes. Afterwards, the
216
same procedure was applied to the epineurium to complete the nerve repair. The model
218
ED
PT
CE
AC
217
M
207
has a significant resemblance to peripheral nerve tissues in terms of resistance to suturing.
11
CR IP T
ACCEPTED MANUSCRIPT
219
FIGURE 6. Nerve model with pristine formulations. a) Removal of fascia tissue to release the
221
peripheral nerve, b) A cut on epineurium, and a view fascicles and connective tissue, c)
222
Microsutures on fascicles, d) Microsutures on epineurium.
AN US
220
The critical part of epineural repair is the correct alignment of the nerve ends that
224
are to be sutured. Figure 7 shows a cut on the peripheral nerve model with 0.1 wt %
225
cotton fiber. The alignment of both ends was followed by repair with 8/0 sutures. The
226
thickness of the suture was higher than the one that was used for the pristine
227
formulations to comply with the topology of higher elastic modulus structures. The
228
addition of fiber increased the suture resistance of the epineurium, and structures with
229
fibers hold the sutures better compared to pristine formulations.
AC
CE
PT
ED
M
223
230
12
ACCEPTED MANUSCRIPT
231
FIGURE 7. Nerve model with 0.1 wt % cotton fibers. a-c) Systematic assessment of a nerve cut
232
and microsuturing of the epineurium layer
233
4 | DISCUSSION Peripheral nerve injuries commonly occur in radial, ulnar, and median nerves [38-
235
40]. Although technological aids such as operating microscopes and microsurgical
236
suture materials provided significant improvements in peripheral nerve microsurgery,
237
the repair of these nerves still remains as a challenge due to the complex nature of
238
these structures [41, 42]. Treatment plan necessitates an accurate classification of the
239
nerve injury [43] and the most severe type of these nerve injuries is the fifth-degree
240
(Seddon’s neurotmesis) [44, 45] injuries, in which all of the sub-structures of the
241
peripheral nerve (i.e., endoneurium, the fascicles, Schwann cells, axons, and the
242
epineurium) are completely ruptured. Precise alignment at the fascicular level with
243
shorter operation, dissection, and anesthetic times are also crucial for the post-
244
operative functional repair of the nerves. For successful simulations, models should
245
resemble the sub-structures in a realistic manner [46],[47]. The model proposed here
246
offers a standardized and well-characterized system on which microsuturing maneuvers
247
can be practiced repetitively by microsurgeons-in-training.
249 250
AN US
M
ED
PT
CE
The model weighs less than 100 g; hence, the cost of materials is around 2 USD.
AC
248
CR IP T
234
Although, it is a labor-intensive process, we prototyped the model with lean manufacturing principles to i) include minimum number of molds (with no complicated
251
molds) and ii) necessitate only a scale and an oven for processing.
252
5 | CONCLUSION
13
ACCEPTED MANUSCRIPT
The mechanical repair of nerves—alignment and suturing of epineurium and
254
nerve fascicles—requires considerable practice. While cadavers are hard to access,
255
and there are ethical concerns regarding the use of animals for training, primitive
256
synthetic models for this type of tactile simulation have often failed to address the
257
hierarchical and complex structure of the peripheral nerve system. This article aims at
258
describing a fabrication route such that individual laboratories can build their own
259
models with minimum equipment and collectively improve the training materials for
260
microsurgical education. The hierarchical model described here offers surgeons to
261
realistic means of practice at their own pace in a standardized medium. Therefore,
262
surgeons can potentially improve their eye-hand coordination on this model, which in
263
turn, may reduce the number of cadavers/animal models that are routinely used in
264
microsurgical training.
265
Conflict of Interest
266
The authors have no conflicts of interest to disclose.
267
Acknowledgement
268
The authors would like to thank Mr. Sirous Khabbaz for his help with SEM.
269
Financial Disclosure
271
AN US
M
ED
PT
CE
AC
270
CR IP T
253
O. A. acknowledges The Scientific and Technological Research Council of Turkey (TUBITAK) for the financial support to this project through 1507 SME Research,
272
Development, and Innovation Grant (7160976) and 1005 National New Ideas and
273
Products Research Support Program (214M121).
274
References
14
ACCEPTED MANUSCRIPT
275
[1]
Chan WY, Matteucci P, Southern SJ.Validation of microsurgical models in
276
microsurgery training and competence: A review. Microsurgery 2007; 27: 494–
277
499 DOI: 10.1002/micr.20393 [2]
International Publishing; 2016 DOI: 10.1007/978-3-319-27315-0
279 280
Veznedaroglu E. Controversies in vascular neurosurgery. Switzerland: Springer
[3]
CR IP T
278
Rutner TW, Ziccardi VB, Janal MN. Long-term outcome assessment for lingual
281
nerve microsurgery. J Oral Maxillofac Surg 2005; 63(08): 1145–1149 DOI:
282
10.1016/j.joms.2005.04.023 [4]
made? Int J Surg 2013; 11: 773–778 DOI: 10.1016/j.ijsu.2013.07.001
284 285
Sadideen H, Alvand A, Saadeddin M, Kneebone R. Surgical experts: Born or
AN US
283
[5]
Odobescu A, Moubayed SP, Danino MA. Thiel cadaveric nerve tissue: A model for microsurgical simulation. J Brachial Plex Peripher Nerve Inj 2016; 11: e18–
287
e20DOI: 10.1055/s-0036-1580626 [6]
Ilie VG, Ilie VI, Dobreanu C, Ghetu N, Luchian S, Pieptu D. Training of
ED
288
M
286
microsurgical skills on nonliving models. Microsurgery 2008; 28: 571–577 DOI:
290
10.1002/micr.20541 [7]
Steffens K, Koob E, Hong G. Training in basic microsurgical techniques without
CE
291
PT
289
experiments involving animals. Arch Orthop Trauma Surg 1992; 111: 198–203
293
DOI: 10.1007/BF00571477
294 295 296 297
AC
292
[8]
Goldstein M. Use of fresh human placenta for microsurgical training. Microsurgery 1979; 1: 70–71 DOI: 10.1002/micr.1920010110
[9]
Govila A, Sharma D. Microsurgical practice on avulsed skin. Br J Plast Surg 1990; 43: 250–251 DOI: 10.1016/0007-1226(90)90172-V
15
ACCEPTED MANUSCRIPT
298
[10]
Microsurgery 2001; 21: 379–382 DOI: 10.1002/micr.21812
299 300
Fanua SP, Kim J, Wilgis SEF. Alternative model for teaching microsurgery.
[11]
Nam SM, Shin HS, Kim YB, Park ES, Choi CY. Microsurgical training with porcine thigh infusion model. J Reconstr Microsurg 2013; 29: 303–306 DOI:
302
10.1055/s-0033-1333623
303
[12]
CR IP T
301
Lannon DA, Atkins JA, Butler PEM. Non-vital, prosthetic, and virtual reality
304
models of microsurgical training. Microsurgery 2001; 21: 389–393 DOI:
305
10.1002/micr.21709 [13]
Singh M, Ziolkowski N, Ramachandran S, Myers SR, Ghanem AM. Development
AN US
306 307
of a five-day basic microsurgery simulation training course: A cost analysis. Arch
308
Plast Surg 2014; 41: 213–217 DOI: 10.5999/aps.2014.41.3.213 [14]
Surg Educ 2017; 75(1): 171–181 DOI: 10.1016/j.jsurg.2017.06.032
310
[15]
Korber KE, Kraemer BA. Use of small-caliber polytetrafluoroethylene (gore-tex ®)
ED
311
Evgeniou E, Walker H, Gujral S. The role of simulation in microsurgical training. J
M
309
grafts in microsurgical training. Microsurgery 1989; 10: 113–115 DOI:
313
10.1002/micr.1920100208 [16]
microvascular training. Ann Plast Surg 1985; 14(5): 462–464
315
317 318 319
[17]
Chiono V, Tonda-Turo C. Trends in the design of nerve guidance channels in
AC
316
Ramasastry S, Narayanan K,Angel MF. A simple and inexpensive device for
CE
314
PT
312
peripheral nerve tissue engineering. Prog Neurobiol 2015; 131: 87–104 DOI: 10.1016/j.pneurobio.2015.06.001
[18]
Driscoll PJ, Glasby MA, Lawson GM. An in vivo study of peripheral nerves in
320
continuity: Biomechanical and physiological responses to elongation. J Orthop
321
Res 2002; 20: 370–375 DOI: 10.1016/S0736-0266(01)00104-8
16
ACCEPTED MANUSCRIPT
[19]
United States: Lippincott Williams & Wilkins; 2001 ISBN: 9780683302479
323 324
[20]
[21]
Rogers JA, Balooch G. Biomedical materials: A restorative synthetic skin. Nat Mater 2006; 15: 828–829 DOI: 10.1038/nmat4710
327 328
Mai JK, Paxinos G. The human nervous system, United States: Elsevier, Academic Press; 2011 ISBN: 9780123742360.
325 326
Nordin M, Frankel VH. Basic biomechanics of the musculoskeletal system.
[22]
CR IP T
322
Costantino PD. Synthetic biomaterials for soft-tissue augmentation and replacement in the head and neck. Otolaryngol Clin North Am 1994; 27: 223–262
330
PMID: 8159424
331
[23]
AN US
329
Breimer GB, Bodani V, Looi T, Drake JM. Design and evaluation of a new synthetic brain simulator for endoscopic third ventriculostomy. J Neurosurg:
333
Pediatr 2015; 15: 82–88DOI: 10.3171/2014.9.PEDS1447 [24]
[25]
[26]
342 343 344
[27]
Hosnuter M, Tosun Z, Savaci N. A nonanimal model for microsurgical training
AC
341
Mehta A, Li PS, Goldstein M. Male infertility microsurgical training. Transl Androl Urol 2014; 3: 134–141 DOI: 10.3978/j.issn.2223-4683.2014.02.05
339 340
PT
338
SMOOTH-ON, https://www.smooth-on.com/applications/medical-simulation/. Last accessed 2017.
337
ED
desktop 3D printer. Sci Rep 2014; 4: 6973 DOI: 10.1038/srep06973
335 336
He Y, Xue GH, Fu JZ. Fabrication of low cost soft tissue prostheses with the
CE
334
M
332
with adventitial stripping. Plast Reconstr Surg 2000; 106: 958–959 DOI: 10.1097/00006534-200009040-00057
[28]
Sunderland S. The anatomic foundation of peripheral nerve repair techniques. Orthop Clin North Am 1981; 12: 245–266 PMID: 7243238
17
ACCEPTED MANUSCRIPT
[29]
100: 350–357 DOI: 10.9738/INTSURG-D-14-00004.1
346 347
[30]
Millesi H, Zoch G, Reihsner R. Mechanical properties of peripheral nerves. Clin Orthop Relat Res 1995; 314: 76–83 PMID: 7634654
348 349
Agha RA, Fowler AJ. The role and validity of surgical simulation. Int Surg J 2015;
[31]
Mattana G, Cosseddu P, Fraboni B, Malliaras GG, Hinestroza JP, Bonfiglio A.
CR IP T
345
350
Organic electronics on natural cotton fibres. Org Electron 2011; 12: 2033–2039
351
DOI: 10.1016/j.orgel.2011.09.001
352
[32]
Fantilli AP, Sicardi S, Dotti F. The use of wool as fiber-reinforcement in cementbased
354
10.1016/j.conbuildmat.2016.10.096
355
[33]
mortar.
Constr
Build
Mater
2017;
139:
AN US
353
562–569
DOI:
Borschel GH, Kia KF, Kuzon WM Jr, Dennis RG. Mechanical properties of acellular peripheral nerve. J Surg Res 2003; 114: 133–9 DOI: 10.1016/S0022-
357
4804(03)00255-5 [34]
Liu G, Zhang Q, Jin Y, Gao Z. Stress and strain analysis on the anastomosis site
ED
358
M
356
sutured with either epineurial or perineurial sutures after simulation of sciatic
360
nerve injury. Neural Regen Res 2012; 7: 2299–2304 DOI: 10.3969/j.issn.1673-
361
5374.2012.29.009 [35]
AC
365
Ma X, Yang Z, Li X, Ma J, Zhang Y, Guo H, Sun X. A study on biomechanical properties of chemically extracted acellular peripheral nerve. Chinese J Reparat
363 364
CE
362
PT
359
Reconstr Surg 2010; 24: 1293–1297 PMID: 21226347
[36]
Serpe LCT, Las Casas EBD, Toyofuku ACMM, González-Torres LA. A bilinear
366
elastic constitutive model applied for midpalatal suture behavior during rapid
367
maxillary expansion. Res Biomed Eng 2015; 31: 319–327 DOI: 10.1590/2446-
368
4740.0637
18
ACCEPTED MANUSCRIPT
369
[37]
Su P, Yang Y, Huang L. Biomechanical simulation of needle insertion into cornea
370
based on distortion energy failure criterion. Acta Bioeng Biomech 2016; 18(1):
371
65–75 DOI: 10.5277/ABB-00248-2014-02
372
[38]
Noble J, Munro CA, Prasad VS, Midha R. Analysis of upper and lower extremity peripheral nerve injuries in a population of patients with multiple injuries. J
374
Trauma 1998; 45: 116–122 DOI: 10.1097/00005373-199807000-00025 [39]
Bone Joint Surg Br 1991; 73: 154–7 DOI: 10.1302/0301-620X.73B1.1991753 [40]
injury
378
[41]
recovery.
Hand
Clin
2013;
29:
317–330
DOI:
Rasulić L. Introduction: Facing the challenges of peripheral nerve surgery in the 21st century. World Neurosurg 2015; 84: 596 DOI: 10.1016/j.wneu.2015.05.054
381
[42]
Pratt GF, Rozen WM, Chubb D, Whitaker IS, Grinsell D, Ashton MW, Acosta R.
ED
382
and
10.1016/j.hcl.2013.04.002
379 380
Menorca RMG, Fussell TS, Elfar JC. Peripheral nerve trauma: Mechanisms of
AN US
376 377
Birch R, Raji AR. Repair of median and ulnar nerves. Primary suture is best. J
M
375
CR IP T
373
Modern adjuncts and technologies in microsurgery: An historical and evidence-
384
based review. Microsurgery 2010; 30: 657–666 DOI: 10.1002/micr.20809 [43]
Chhabra A, Ahlawat S, Belzberg A, Andreseik G. Peripheral nerve injury grading
CE
385
PT
383
simplified on MR neurography: As referenced to Seddon and Sunderland
387
classifications. Indian J Radiol Imaging 2014; 24: 217–224 DOI: 10.4103/0971-
388 389
AC
386
3026.137025
[44]
1998; 11: 111–117 DOI: 10.1016/S0894-1130(98)80007-0
390 391 392
Dagum AB. Peripheral nerve regeneration, repair, and grafting. J Hand Ther
[45]
Katirji B. Case 12. Electromyography in clinical practice (Second Edition). Philadelphia: Mosby; 2007 ISBN: 9780323028998.
19
ACCEPTED MANUSCRIPT
393
[46]
Bayramiçli M, Şirinoğlu H, Yalçin D. A basic experimental model for end-to-end
394
anastomosis of vessels with diameter discrepancy. Microsurgery 2014; 34: 333–
395
334 DOI: 10.1002/micr.22233 [47]
Kalomiri DE, Soucacos PN, Beris AE. Nerve grafting in peripheral nerve
397
microsurgery
of
the
upper
398
51110.1002/micr.1920150714
extremity.
Microsurgery
1994;
15:
CR IP T
396
399
AC
CE
PT
ED
M
AN US
400
20
506–