Thickness effects in split Hopkinson pressure bar tests

Thickness effects in split Hopkinson pressure bar tests

Thickness effects in split Hopkinson pressure bar tests N. N. Dioh*, P. S. Leevers and J. G. W i l l i a m s Department of Mechanica/ Engineering. /mp...

418KB Sizes 1 Downloads 81 Views

Thickness effects in split Hopkinson pressure bar tests N. N. Dioh*, P. S. Leevers and J. G. W i l l i a m s Department of Mechanica/ Engineering. /mperia/ College of Science, Technology and Medicine, Exhibition Road, London SW7 2BX, UK (Received 25 February 1993) Results are presented for the high strain rate behaviour of a medium and high density polyethylene, polycarbonate and poly(ether ether ketone) in compression for strain rates up to 104 s-1 obtained using a split Hopkinson pressure bar apparatus. It is shown that the choice of specimen thickness in these tests significantly affects the measured flow stresses at high strain rates, with the thicker specimens showing an apparent enhancement of flow stress at high rates. Comparison of the present results with published work suggests that some high strain rate data in the literature could be erroneous due to an inappropriate choice of specimen dimensions. (Keywords: compression; strain rate; specimen dimensions)

INTRODUCTION The increasing use of polymers in applications where they are subjected to rapid loading ranges from the use of polycarbonate as shields 1 to the use of polyethylene in pipelines for the distribution of fuel gas 2 where, in the event of an accidental impact, pipes can fail catastrophically by propagation of a fast-running crack. Since axial rapid crack propagation can destroy hundreds of metres of pipe within a few seconds, the economic and safety implications are very serious. There is therefore a great need for data on the properties of polymers at high strain rates. In spite of this there are few published works 3-s on the behaviour of polymers at strain rates above 10 3 S -1, all of which involve experiments using split Hopkinson pressure bar apparatus. Walley et al. 3'4 and Briscoe and Nosker 5'6 achieved high strain rates by testing very thin specimens, typically less than 2 mm. On the other hand, Rietsch and Bouette 7 and Chou et al. 8 used rather thick specimens, typically greater than 8 mm, and achieved high strain rates by employing successively higher impact velocities. Briscoe and Nosker 5'6 concluded from their tests on high density polyethylene that the strain rate sensitivity of this material could be described by an Eyring model for strain rates up to 10 4 S - 1. Walley et al. 3'4 also arrived at a similar conclusion for most of the polymers tested, although in some cases they reported a drop in measured flow stresses at strain rates in excess of 10 3 s -1, which they attributed to thermal processes. However, results obtained by Rietsch and Bouette 7 and Chou et al. a showed an increase in the measured flow stresses at high strain rates for all the materials tested, thereby suggesting an increase in strain rate sensitivity at strain rates above 10 3 s - 1. Rietsch and Bouette 7 went further and explained this behaviour in terms of a difference in relaxation modes at high and low strain rates. The present workers, *To whom correspondenceshould be addressed 0032 3861/93/204230~35 © 1993 Butterworth-HeinemannLtd.

4230

POLYMER, 1993, Volume 34, Number 20

however, believe that this observed increase in strain rate sensitivity reported by some authors at high strain rates is related to specimen thickness. The objectives of the work described here were: (1) to carry out an investigation on the effect of specimen thickness in split Hopkinson pressure bar tests at strain rates above 10 3 S -1, and (2) to alleviate the paucity of high strain rate data on polymers. In order to achieve this, tests on four polymers were carried out at low (10-4-10 -1 s-l), intermediate (10-1-102 s -1) and high (102-104s -1) strain rates and for various specimen thicknesses. EXPERIMENTAL Materials

The strain rate sensitivity of four thermoplastics has been studied: medium density polyethylene (MDPE; Rigidex 002/50, from BP Chemicals); a modified high density polyethylene (HDPE; Soltex TUB 125, from Solvay); polycarbonate (PC, Lexan, from General Electric); and poly(ether ether ketone) (PEEK; Victrex, from ICI). All the materials were supplied in the form of compression-moulded sheets. The samples were machined into 12.7mm diameter discs of thickness 4.4mm or 1.5mm. Before testing, each specimen was coated with a thin layer of petroleum jelly, which has been shown to be a good lubricant for testing polymers at high strain rates 3 5. Tests

The low and intermediate rate tests were carried out on an Instron and a Mayes machine, respectively. Due to the small specimen thicknesses used, a linear voltage differential transducer (LVDT) was used to monitor specimen deformation. Strain rate was calculated from the LVDT readings and checked against the chosen crosshead velocity of the machine.

Thickness effects in pressure bar tests. N. N. Dioh e t al.

All high rate tests were carried out in a split Hopkinson pressure bar apparatus. In its compressive configuration this consists of two long elastic bars, an input and output, with the disc-shaped specimen sandwiched in between. Both the input and output bars are made from 15.8 mm diameter high strength aluminium (HE15) bars. The free end of the input bar is subjected to an axial impact by a projectile made from the bar stock. This generates a compressive loading pulse which travels along the input bar towards the specimen. Due to a difference in mechanical impedance between the bars and the specimen, interaction of the incident pulse and the specimen results in stress waves being reflected back into the input bar and also being transmitted through the specimen into the output bar. Having recorded the incident, reflected and transmitted strain pulses at fixed points in the bar (denoted by el(t), £R(t) and ex(t)), the displacement conditions at the specimen-bar interfaces can be established. The variation of stress and strain in the sample are conventionally obtained from the following expressions9:

es(t) - --2Cb l

;o

•R(t) dt

50

(c) High

40 (b) Intermediate 30 (a) Low

20 r~

10 0 0

I

I

10

20

30

Strain/% Figure 2 Typical stress-strain curves for M D P E at 23°C for various strain rates. Curves (a), (b) and (c) correspond to average strain rates of 0.00037s -1, 9.35s -1 and 3910s 1, respectively

60 50

(c) High

40

(b) Intermediate

(1) e~

30 (a) Lo*

\As/ 20

--2C b ~s(t) =

l

eR(t)

(3)

where es(t), as(t) and ~s(t) are the variation of strain, stress and strain rate, respectively, in the specimen with time. E and Cb are the Young's modulus and elastic wave speed in the bars, respectively, while I is the initial length of the specimen and A / A s is the area ratio between the bars and the specimen. The strain pulses are shifted in time so as to be coincident at the specimen. The stress-strain relation of the material being measured can then be obtained by eliminating time, t, between equations (1) and (2), and the strain rate directly from equation (3).

10 0

0

I

i

10

20

30

Strain/% Figure 3 Typical stress-strain curves for H D P E at 23°C for various strain rates. Curves (a), (b) and (c) correspond to average strain rates of 0.000 39 s 1 9.58 s I and 4450 s 1, respectively

200

--

(c) High

RESULTS AND DISCUSSION Wherever possible, results such as those shown in Figures 1 to 4 are presented in the form of yield stress against the logarithmic strain rate in order to assess the

(a) Low I00

50

125

(c) High 100

0

0 (b) Intermediate

75

i

I

10

20

30

Strain/% Figure 4 Typical stress-strain curves for P E E K at 23°C for various strain rates. Curves (a), (b) and (c) correspond to average strain rates of 0.000 375 s 1 8.44 s 1 and 5520 s - 1 respectively

(a) Low 50 ct~

25 0

0

I

I

10

20

30

Strain/% Figure 1 Typical stress-strain curves for PC at 23°C for various strain rates showing a definite yield point. Curves (a), (b) and (c) correspond to average strain rates of 0.000368s -1, 8.43s 1 and 6000s -1, respectively

strain rate sensitivity of the material under investigation. This was only possible for PC, since it is the only material tested that exhibits a yield point in compression. For the other materials, plots of flow stress at specific values of strain were produced instead (Figures 7 to 12). Whereas at intermediate strain rates there is good agreement between the measured flow stresses for both specimen thicknesses, at high strain rates the measured

POLYMER, 1993, Volume 34, Number 20

4231

Thickness effects in pressure bar tests." N. N. Dioh et al. 130

Eyring m o d e l c a n n o t a d e q u a t e l y describe the b e h a v i o u r of P C an d P E E K at r o o m t e m p e r a t u r e b et w een the strain rates of 10 - 4 an d 10 4 s -~. Th e results o b t a i n e d for H D P E (Figures 9 and 10) are in a g r e e m e n t with those r e p o r t e d by Briscoe and N o s k e r 6. Th e present w o r k suggests that the simple Eyring model, which has been s h o w n to describe closely the b e h a v i o u r of P C at low strain rates ~°, is i n a d e q u a t e at high strain

120 110 100 ~2

90

>,

80

E/

70 60

rn

D ....... '

i 0 -4

........ '

....... ~

....... '

....... i

i0-3 10.2 i0 -I i0 0

....... •

i01

....... •

102

50

......

103

10 4

Strain rate / s "i

t~

Figure 5 Measured yield stress as a function of logarithmic strain rate for PC at 23°C. Symbols: [3, 4.4 mm thick specimen; O, 1.5 mm thick specimen

o~

4O

30

O

130

20

120 t~

10

110

I

I

Drn

100

I

I

0-4 10-3 10-2 10-1 10°

[] I

I

I

101

102

I

103

10 4

Strain rate/s -I

r,O O

90

Figure 8 Measured 15% flow stress as a function of logarithmic strain rate for MDPE at 23°C. Specimen thickness: [~, 4.4 mm; O, 1.5 mm

g

80 oo

70

D

[]

[]

50 01

I

I

I

I

0-4 10-3 10-2 i0-i i00

I

I

I

I01

102

103

104

Strain rate/s ] 40

Figure 6 Measured 8% flow stress as a function of logarithmic strain rate for PC at 23°C. Specimen thickness: IS], 4.4mm; O, 1.5 mm O

Y, 50

30

l~/

40 2~0-4

I 10-3

I 10 .2

10 0

101

10 2

10 3

10 4

Strain rate/s'l

30

Figure 9 Measured 10% flow stress as a function of logarithmic strain rate for HDPE at 23°C. Specimen thickness: [3, 4.4 mm; O, 1.5 mm

0

0

10 -I

20 i flI

60 ,

I

,

I

I

I

I

1~10.4 10-3 10-2 lO-i 100 10 1 102 103 104 105 Strain rate/s "]

50

Figure 7 Measured 10% flow stress as a function of logarithmic strain rate for MDPE at 23°C. Specimen thickness: [3, 4.4 mm; O, 1.5 mm r~

flow stresses for the th in n e r specimens are significantly l ow er for all the m a t e r i a l s tested. T h e b e h a v i o u r of the M D P E an d H D P E at r o o m t e m p e r a t u r e c a n be described by the E y r i n g m o d e l if the high rate d a t a for the t h i n n e r specimens are used. U s i n g the d a t a for the thicker specimens at high strain rates w o u l d lead to the c o n c l u s i o n t h a t the strain rate sensitivity of each m a t e r i a l increases suddenly at high strain rates. H o w e v e r , even results for t h i n n e r specimens suggest that the simple

4232

P O L Y M E R , 1 9 9 3 , V o l u m e 34, N u m b e r 2 0

40

30

2n

I

0 -4

I

I

I

10-3 i0 -2 i0 -! 10 °

I

I

I

101

i02

103

104

Strain rate/s'l

Figure 10 Measured 15% flow stress as a function of logarithmic strain rate for HDPE at 23°C. Specimen thickness: V], 4.4mm; 0 , 1.5 mm

Thickness effects in pressure bar tests. N. N. Dioh et al. rates, towards which a gentle increase in strain rate sensitivity emerges (Figures 5 and 6). The results presented in these figures also show that if the specimen thickness is chosen carefully, the sudden increase in the strain rate sensitivity of PC at high strain rates, reported by Rietsch and Bouette 7 (Figure 13), does not appear. This suggests that the sudden increase in strain rate sensitivity of a range of polymers at strain rates above 103 s - 1, observed by Chou et al. 8 (Figure 14) for specimen thicknesses of 9.5 mm, might also disappear for an appropriate choice of thickness. N o comparisons can be made for P E E K as data at strain rates above 250 s-1 are not available in the literature. A sharp increase in the strain rate sensitivity of most metals has also been reported at high strain rates; there is still some controversy as to the underlying explanation. In the past, this behaviour was generally interpreted as a transition from one or more of a series of thermally activated flow mechanisms at low rates to a flow process dominated by viscous drag at high rates. However, recent work by Follansbee and Kocks 11 suggests that this observed behaviour can be more accurately interpreted as a change in the way the structure evolves with strain. By considering deformation velocity, friction and inertia in these high rate tests, G o r h a m 12 argues by a process of elimination that inertial resistance to longitudinal and radial deformation may be responsible. By compiling experimental data for copper obtained by various authors, he shows that the strain rate at which this sharp increase in strain rate sensitivity occurs is influenced by the specimen geometry. F r o m the evidence presented, it is apparent that if results obtained at high strain rates are to be relied upon, then they must be shown to be independent of geometry, in particular specimen thickness.

200 [] [] c~

[]

180

#

160

B

140 rr.

[] [] 120

[]

1p,/",

I

0 -4

I

f

10-3

10 -2

10 -1

I

I

I

I

10 0

101

10 2

10 3

10 4

Strain rate/s ]

Figure 11 Measured 8% flowstress as a function of logarithmic strain rate for P E E K at 23°C. Specimen thickness: 1--], 4.4 mm; 0 , 1.5 m m

200

[] c~

m

180

$

160 (/2 O tt~

B

140

B

[] 120

[]

1(3010-4

I

I

10 -3

I

10 -2 10 -1

I

I

I

I

10 °

101

10 2

103

104

Strain rate/s'l

Figure 12 Measured 15% flow stress as a function of logarithmic strain rate for P E E K at 23°C. Specimen thickness: IS], 4 . 4 m m ; O , 1.5 m m

.$

I

I

I

I

I

I

I

I

I

I~ -.4e'c ~i O /

.?

Io ze',,

/

: qm'c / I;II'~,I

.6

#

IZPDIEN~ ~=11-- .4

O

o





o..,~

FUll Lt,ts~ • ¢.,AX,CULAI"I~ COlliES

A'-"

¢O0"FS : A~.. | . i l k I'FI,K-I ~..~- 4 , 1 K o 3 | • U a - E§ kctl/mol - 6,054 HPI,K-I _~- ;t,9(-7 s Qp" 5 , | k¢tlimmt

.3

Ii" ...,,,.-,-tl



,

.2

.! -11

l

-o

,

I

-~

J

I

-4

,

I

-a

,

I

Ln(i Figure 13

i

e

I

a

r

t

l

4

s

,

I

o

,

to

)

M e a s u r e d ratio of yield stress as a function of l o g a r i t h m i c strain rate for PC. After Rietsch a n d Bouette v

POLYMER, 1993, Volume 34, Number 20

4233

Thickness effects in pressure bar tests. N. N. D/oh

et

al.

i

~am~mmmammam~m

II'"'",,1,,, I I

16

I

I I11111 I Illlll

I ]

] ] I , , , ,..... , I I

I llllll I 111111

I

I

I I

I I

II II'"' IIII 111111

II

I IIIIII

l

ill

!0~_;__~3 ON TI~ COllW.S DDI~TE II I

I

l, i | !

Itll

IIii

!

III III Iii Ill

I I

[11

I

III III I!l Ill Ill

I

II

Ix

11711 Ill Ilili I1[

I

i

III Ill III III Ill III Ill Ill III 1tl III Ill Ill Ill Ill III Ill

II11 II11 I111 I III I III 1111 I111 1111 lilT

lSl

'i

IIII

IIII

I

!t!,.

il i

lilill I1'.,11

,

il,II

sl

Ii II Lf;

l

I

,I

1

I

'i

,I I

,!

I

.

,

.~,,.

i

,

!!!:!]

I i1"I!1 l ;I[lII

II]Ill ]l':ll

I 1

i tlIlll ~ I : I :-/.,~'-i'

'.~liP r

A

~

~.f~l i,, ] I l / , 1 i ~.m~"T,l! ~"I I ! ! '

i I ?, r ~ I I ' L.,,,flm'T II d~.~rr~:lll !1 - . d ~ l ' - J I ttlll

/ L..,.,.~, ~r"q ~ i

[i i;ll i

i I

I ;

! :' i~',:

~ , , 1 ~

[II !f J 111[

~,

I

i~..djlmT[

{ I l

I I 1 l :

i 1 I !

l

!

~

:l;,il I i! II l

~

I I Illl I i[III

I

i

I1 11 II

I Illill

I ] I ~''''',,,,.

10 . 2

.I . . [. . .[ I11 I I1:'1 I IIIII

l

.......

I I

[

...... Ill*ll I Ilill

I ,';

~.

• /I

I

___//__l

v

I I[l!t

I

i_/7_/ I

......

1

I11]11 ,ill

i

:

" ~ilall-,I

] • i.,1~ ~1 ~'-

!L...-~

ii ]

i[II]'" 10 *$

_..---, :r]

J.~'-I

J.~.'~T

-4

~

'

]

#I!/

.......

~

/ I

/

...

"#

it"

I:

I

--*/-; I

I

-

!

~ I~I

! '

'

I I i!ll

II

I I

I ! '-,.,~-

///:

;. . .ill", ....

1 Illll i 111 I ]11

~ ,--~.,'-~.~

......, ',IIi',1

T 11 I II;'ll I1'.

//!

I IIIII

IN III "l

II]!11 IIilll 41i111 III

...... I I1111 I IIIII I IIIIl I IlIII I I I III

III

"11"

ttt 111 III

I II111 II1!11 III111 I I1111

I111

11 tl llllll IIilll r II!qll 11IIII I I II11 111111 Illlll 111111

Ill !11 III

I

Ill

I

111111 111111 IIIlll It1111 111111 IIIIII llilll II1111 IIIlll III111 lll]ll

Ill Ill 111 Ill

i ii

I'"

III

!

10

i

111111

: ~

I 1

. ..~,,,~

J I.:~lll ' I

~ T

! }'ill :, '~11 . i , ~ . ~ " "

[] i

t l

I II,!II ii]lill

I

I

I

! ~

~" "

I 't '~''~m'~ _..,~Pr-~ I m,;l[I itSlll

...~

• I

/

/ /. " ~

II'.lll i lJl:l

,,,,

','":,11,,,

lllIII

I Ill,l,,,

10 "1

~ i ~ ' ~ ' ~

,],

,

"11

T i I !

Ill ill] I E;I,I

, z.J:~,[ ~

I 1 1 I

i '

1

101

10 2

sos

2o4

STRAIN lATE ( n c *1)

Figure 14 Measuredflow stress as a function of logarithmic strain rate for polypropylene. After Chou e t

CONCLUSION Results have been presented for the high strain rate behaviour of M D P E , H D P E , PC and P E E K at r o o m temperature for strain rates up to 10 4 s-1. The effect of specimen geometry on these results at intermediate and high strain rates has also been investigated. At intermediate strain rates, good agreement is obtained between the measured flow stresses for both specimen thicknesses. At high rates, however, the measured flow stresses for the thinner specimens are significantly lower for all the materials tested. The results are shown to be consistent with those in the literature. This suggests that some results available in the literature may be erroneous due to an inappropriate choice of specimen dimensions, undermining conclusions made about the inherent behaviour of the materials under investigation.

during the course of the work, and to Stewarts and Lloyds Plastics and ICI Plastics for providing polymer samples.

REFERENCES 1 2 3 4 5 6 7 8

ACKNOWLEDGEMENTS

9 10

The authors are grateful to the Quantum Chemical Corporation for providing the financial support necessary

11 12

4234

POLYMER,

1993,

Volume

34,

Number

20

al. 8

Fleck, N. A. and Wright, S. C. in 'Mechanical Properties at High Rates of Strain' (Ed. J. Harding), The Institute of Physics, Bristol, 1989, p. 73 Yayla, P. and Leevers, P. S. Eng. Fracture Mech. 1992, 42, 675 Walley, S. M., Field, J. E., Hope, P. H. and Safford, N. A. Phil. Trans. R. Soc. London 1989, A328, 1 Walley, S. M., Field, J. E., Hope, P. H. and Safford, N. A. J. Phys. III, France 1 1991, 1889 Briscoe, B. J. and Nosker, R. W. Wear 1984, 95, 241 Briscoe, B. J. and Nosker, R. W. Polym. Commun. 1985, 26, 307 Rietsch, F. and Bouette, B. Eur. Polym. J. 1990, 26, 1071 Chou, S. C., Robertson, K. D. and Rainey, J. H. Exp. Mech. 1973, 13, 422 Lindholm, U. S. J. Mech. Phys. Solids 1964, 12, 317 Bauwens-Crowet, C., Bauwens, J. C. and Homes, G. J. Polym. Sci. A2 1969, 7, 735 Follansbee, P. S. and Kocks, U. F. Acta Metall. 1988, 36, 81 Gorham, D. A. J. Phys. 1991, 1, 411