TRACHEAL CYLINDROMA: ANAESTHETIC MANAGEMENT

TRACHEAL CYLINDROMA: ANAESTHETIC MANAGEMENT

BRITISH JOURNAL OF ANAESTHESIA 82 PENTAZOCINE AND TREMOR FOLLOWING HALOTHANE ANAESTHESIA MAURICE LIPPMANN Torrance, California REFERENCES Geffin, ...

219KB Sizes 1 Downloads 110 Views

BRITISH JOURNAL OF ANAESTHESIA

82 PENTAZOCINE AND TREMOR FOLLOWING HALOTHANE ANAESTHESIA

MAURICE LIPPMANN

Torrance, California REFERENCES

Geffin, B., Bland, J., and Grillo, H. C. (1969). Anesthetic management of tracheal resection and reconstruction. Anesth. Analg. (Cleve.), 48, 884. Lippmann, M., and Mok, M. S. (1977). Tracheal cylindroma: anaesthetic management. Br. J. Anaesth., 49,383. TOXICITY OF LOCAL ANAESTHETICS

Sir,—Recent advances in the field of local anaesthesia have stirred lively interest in the tissue distribution and metabolism of these drugs. Unfortunately, although much valuable information has been gained from these studies, often much of this work has been done in a clinically irrelevant setting or conclusions have been reached that are at the moment still speculative, or both. The recent study by Malagodi, Munson and Embro (1977) on the effect of infusion rates on the acute toxicity of etidocaine and bupivacaine in Rhesus monkeys concluded that etidocaine was less toxic than bupivacaine. Accidental intravascular injection of a local anaesthetic solution is the most obvious possibility for acute systemic toxicity. Therefore, it is desirable that acute toxicity studies duplicate infusion rates used clinically in extradural block or peripheral nerve block. In the clinical studies where extradural infusion rates are indicated (Bromage, O'Beirn and Dunford, 1974; Tucker and Mather, 1975) they are in the range 150-450 mg min"1. The low end of this spectrum would correspond to the fastest infusion rate in Malagodi's study. Contrary to the overall conclusion of the authors, at these injection rates, etidocaine appeared more toxic than bupivacaine, with the seizure dose for etidocaine being 4.76 mg kg" 1 as opposed to 5.33 mg kg" 1 for bupiS. DESHPANDE vacaine. Clinical studies (Scott, Jebson and Boyes, 1973; Stockton-on- Tees Scott, 1975) have shown also that the etidocaine toxicity threshold decreases as the infusion rate increases. REFERENCES The toxicity from systemic absorption of the local Brichard, G., and Johnstone, M. (1970). The effect of anaesthetic also deserves brief consideration. A number of methylphenidate (Ritalin) on post-halothane muscular studies have disregarded the behaviour at fast infusion spasticity. Br. J. Anaesth., 42, 718. rates, and assumed that the characteristics of the slow Dawkins, M. (1961). Halothane. Lancet, 2, 1259. infusion rates simulate the systemic absorption from the Jones, H. D., and McLaren, C. A. B. (1965). Postoperative injection site and that serum concentrations correlate with shivering and hypoxaemia after halothane, nitrous oxide the appearance of toxicity. and oxygen anaesthesia. Br. J. Anaesth., 37, 35. A comparison of the arterial and venous drug concenWillis, J. H. (1974). Drug Dependence, 2nd edn, p. 49. trations after giving etidocaine and bupivacaine in equal London: Faber and Faber. dose (milligram for milligram) have suggested that the resulting plasma concentrations tend to be greater for TRACHEAL CYLINDROMA: ANAESTHETIC MANAGEMENT bupivacaine. However, these differences seem to be less Sir,—After the publication of our article "Tracheal at the higher doses (Bridenbaugh et al., 1974a, b ; Moore cylindroma: anaesthetic management" (Lippmann and et al., 1976). These data are again of questionable clinical Mok, 1977), a further literature survey revealed an article relevance since they assume that the two local anaesthetics by Geffin, Bland and Grillo (1969). We would like to inform are equipotent. There are a number of studies indicating your readers of this paper and to acknowledge that, in that this is not so. The potency of bupivacaine has been ignorance, we failed in our articles to refer to its existence. estimated to be 1.5 to 2 times that of etidocaine (Bromage,

Downloaded from http://bja.oxfordjournals.org/ at Florida Atlantic University on September 13, 2015

Sir,—Muscular spasticity and tremor occurs during recovery from general anaesthesia, especially following halothane (Dawkins, 1961), and may be associated with hypoxaemia (Jones and McLaren, 1965). This condition may be prevented or controlled by methylphenidate (Brichard and Johnstone, 1970). However, this drug is an unreliable analgesic, may provoke adrenergic overactivity (Brichard and Johnstone, 1970), causes amphetamine-like drug dependence (Willis, 1974) and is usually included in the D.D.A. drug schedule. To test the hypothesis that pentazocine might be an effective substitute for methylphenidate in controlling muscular spasticity and tremor following halothane we studied 100 consecutive patients who developed this condition. Fifty-four patients were given pentazocine 30 mg i.v., and 46 received methylphenidate 20 mg i.v. The patients were allocated randomly to the groups which were comparable in terms of age of the patient and type of operation. The same anaesthetic technique was used although this was not standardized and the duration of anaesthesia was not recorded. The patients were observed in the recovery room for 30 min by a trained nurse who did not know which drug had been given. The nurse was asked to record only the presence of tremor, which was regarded as a more objective assessment to make than spasticity. In all except one of the patients given methylphenidate tremors stopped within a few minutes of the drug being administered and they did not recur. In the one exception, tremor ceased immediately after administration of methylphenidate but recurred slightly. With pentazocine the tremors stopped quickly and did not recur in 46 of the patients, but recurred slightly in seven and were not affected in three. Pentazocine does not control tremor following halothane anaesthesia as well as methylphenidate, but, where hypoxia is not a serious problem and pain is present, pentazocine 30 mg i.v. reduces both ridigity and tremor and provides useful analgesia with less book-keeping for the nursing staff. E. N. S. FRY

Your readers should be made aware also that in the forthcoming Proceedings of the 14th Scandinavian Society of Anaesthesiologist's meeting (1977) Dr A. Baraka's presentation on "Anaesthetic problems during the tragic civil war in Lebanon" deals with a case report of a transsected trachea and its management which is similar to the description in both our article and that of Geffin, Bland and Grillo (1969).

CORRESPONDENCE

Tucker, G. T., and Mather, L. E. (1975). Pharmacology of local anaesthetic agents. Pharmacokinetics of local anaesthetic agents. Br. J. Anaesth., 47, 213.

Sir,—Thank you for the opportunity to reply to Drs Young and Luna. From a careful reading of this letter, it appears that the arguments raised by Drs Young and Luna are based on the mistaken assumption that we stated that etidocaine was less toxic than bupivacaine. However, nowhere in our paper did we make such a statement. As shown clearly in table I of our paper, the only statistically significant differences among any of the measurements made were between seizure doses for etidocaine at 0.5 and 2.0 mg kg- 1 min" 1 and seizure thresholds for etidocaine at 0.5 and 1.0 mg kg- 1 min- 1 . In our discussion we stated "Thus, in clinical practice, where relatively large doses of local anaesthetic drugs are administered and are absorbed slowly—for example, during regional nerve block—etidocaine would be tolerated better MICHAEL D. YOUNG than bupivacaine." This statement was based primarily on MARGOT LUNA the findings of others, as stated in the preceding two senWinthrop Laboratories, New York tences of the paragraph, and secondarily, on results obtained with the slowest infusion rate of the two agents. It should REFERENCES be noted clearly that we showed only a tendency for a Bridenbaugh, P. O., Tucker, G. T., Moore, D. C , Briden- better (and not a statistically significant) tolerance to baugh, L. D., and Thompson, G. E. (1974a). Preliminary etidocaine than bupivacaine. clinical evaluation of etidocaine (Duranest): a new The third paragraph of the letter from Drs Young and long-acting local anaesthetic agent. Ada Anaesthesiol. Luna focuses entirely on erroneous conclusions drawn Scand., 18, 165. from statistically insignificant differences between seizure 1 1 Balfour, R. I. (1974b). Role of doses measured during the rapid (2.0 mg kg" min" ) infusion rate experiments (see table I). In the discussion epinephrine in regional block anesthesia with etidocaine: section we concluded: "However, following rapid adminisa double-blind study. Anesth. Analg. (Cleve.), 53, 430. Bromage, P. R., O'Beirn, P., and Dunford, L. A. (1974). tration . . . as would occur following inadvertent intraEtidocaine: a clinical evaluation for regional analgesia in vascular injection, differences in rates of redistribution and hepatic extraction would be minimized, tending to equalize surgery. Can. Anaesth. Soc. J., 21, 523. Malagodi, M. H., Munson, E. S., and Embro, W. J. (1977). the toxicity of the two agents." This is the conclusion, and Relation of etidocaine and bupivacaine toxicity to rate of the only conclusion, which may be drawn from the data presented. Drs Young and Luna have misread this stateinfusion in Rhesus monkeys. Br.J. Anaesth., 49, 121. Moore, D. C , Bridenbaugh, P. O., Bridenbaugh, L. D., ment also. Thompson, G. E., Balfour, R. I., and Lysons, D. F. Our study, which correctly appeared in the experimental (1974). A double-blind study of bupivacaine and etido- section of British Journal of Anaesthesia, was designed caine for epidural (peridural) block. Anesth. Analg. primarily to evaluate the effect of infusion rate on the (Cleve.), 53, 690. toxicity of both etidocaine and bupivacaine in Rhesus (1975). Bupivacaine monkeys. The small number of non-human species studied compared with etidocaine for vaginal delivery. Anesth. must be considered by the readers in the appropriate context. We hope that most careful readers would be Analg. (.Cleve.), 54, 250. Mather, L. E., Bridenbaugh, P. O., Bridenbaugh, perspicacious enough not to draw conclusions which the L. D., Balfour, R. I., Lysons, D. F., and Horton, W. G. authors have been most cautious to avoid making, on the (1976). Arterial and venous plasma levels of bupivacaine basis of lack of statistically significant data; and to view following epidural and intercostal nerve blocks. Anes- this animal study within the appropriate and intended context. thesiology, 45, 39. The only part of the letter from Drs Young and Luna Morgan, M., and Russell, W. J. (1975). An investigation in man into the relative potency of lignocaine, bupi- which pertains to our study is the third paragraph. The remainder of the letter deals with areas remote from the vacaine and etidocaine. Br. J. Anaesth., 47, 586. Renck, H., and Edstrom, H. (1975). Thoracic epidural object of our paper. The sole exception may be their analgesia—a double-blind study between etidocaine and comment, "Taking individual observations out of context bupivacaine. Acta Anaesthesiol. Scand. (Suppl.), 60, 72. of this clinical reality is to run the danger of coming to Scott. B. (1975). Acute intravenous tolerance of etidocaine. medically misleading conclusions." We agree with this statement and respectfully suggest that Drs Young and Acta Anaesthesiol. Scand. (Suppl.), 60, 117. Scott, D. B., Jebson, P. J. R., and Boyes, R. N. (1973). Luna reread our paper with this thought in mind. Pharmacokinetic study of the local anaesthetics bupiEDWIN S. MUNSON vacaine (Marcaine) and etidocaine (Duranest) in man. MARJORIE H. MALAGODI Br. J. Anaesth., 45, 1010. Gainesville., Florida

Downloaded from http://bja.oxfordjournals.org/ at Florida Atlantic University on September 13, 2015

O'Beirn and Dunford, 1974; Morgan and Russell, 1975; Renck and Edstrom, 1975). Even at the higher etidocaine doses, visceral analgesia was less effective, behaviour was unpredictable when the drug was used for peripheral nerve block, and the intensity of motor block was a problem (Bromage, O'Beirn and Dunford, 1974) or a potential problem (Renck and Edstrom, 1975). Studies that attempted to compare the two drugs at the same milligram doses (Moore et al., 1974, 1975) indicated a greater analgesic efficacy of bupivacaine. In addition, the intense motor blockade produced by etidocaine disturbingly outlasted its analgesic action (Moore et al., 1975). Consequently, equipotent, not equivalent, doses should be compared if a clinically meaningful conclusion is to be drawn. The practising physician is interested in the performance and safety of a drug in the actual clinical setting. Taking individual observations out of context of this clinical reality is to run the danger of coming to medically misleading conclusions.

83