Journal Pre-Proof Tube-in-Tube Membrane Microreactor for Photochemical UVC/H2O2 Processes: A Proof of Concept Vítor J.P. Vilar, Pello Alfonso-Muniozguren, Joana P. Monteiro, Judy Lee, Sandra M. Miranda, Rui A.R. Boaventura PII: DOI: Reference:
S1385-8947(19)31744-9 https://doi.org/10.1016/j.cej.2019.122341 CEJ 122341
To appear in:
Chemical Engineering Journal
Received Date: Revised Date: Accepted Date:
30 April 2019 1 July 2019 25 July 2019
Please cite this article as: V.J.P. Vilar, P. Alfonso-Muniozguren, J.P. Monteiro, J. Lee, S.M. Miranda, R.A.R. Boaventura, Tube-in-Tube Membrane Microreactor for Photochemical UVC/H2O2 Processes: A Proof of Concept, Chemical Engineering Journal (2019), doi: https://doi.org/10.1016/j.cej.2019.122341
This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
© 2019 Published by Elsevier B.V.
JOURNAL PRE-PROOF 1
Tube-in-Tube Membrane Microreactor for Photochemical UVC/H2O2
2
Processes: A Proof of Concept
3
Vítor J.P. Vilara,*, Pello Alfonso-Muniozgurena,b, Joana P. Monteiroa, Judy Leeb, Sandra M.
5
Mirandaa,*, Rui A.R. Boaventuraa
O
6
F
4
7
aLaboratory
8
(LSRE-LCM), Department of Chemical Engineering, Faculty of Engineering, University of
9
Porto, Rua do Dr. Roberto Frias, 4200-465, Porto, Portugal
O
PR
bChemical
and Process Engineering, University of Surrey, Guildford, GU27XH
E-
10
of Separation and Reaction Engineering-Laboratory of Catalysis and Materials
PR
11 12 13
AL
14
16 17
R N
15
18
*Corresponding
19
Tel.: +351 220414937; E-mail address:
[email protected] (Sandra M. Miranda)
JO
U
authors:
20
Tel.: +351 918257824; E-mail address:
[email protected] (Vítor J.P. Vilar)
1
JOURNAL PRE-PROOF Abstract
22
This work proposes a disruptive tube-in-tube membrane microreactor for the intensification of
23
photochemical UVC/H2O2 processes, towards contaminants of emerging concern (CECs)
24
removal from urban wastewaters. The main novelty of this system relies on the radial addition of
25
H2O2 through the porous membrane into the annular reaction zone, providing a more
26
homogeneous distribution of the injected chemical across the whole reactor length. The proposed
27
novel reactor consists of a ceramic ultrafiltration membrane inner tubing and a concentric quartz
28
outer tubing that compose the annulus of the reactor (path length of 3.85 mm). The ultrafiltration
29
membrane is used as a dosing system to deliver small amounts of H2O2 into the annulus of the
30
reactor. In the annulus, where a 2 mg/L of oxytetracycline (OTC) solution flows, UVC light is
31
provided via four mercury lamps located externally to the outer tube. The helical motion of OTC
32
solution around the membrane shell-side enhances H2O2 radial mixing. The efficiency of the
33
photochemical UVC/H2O2 process was evaluated as a function of the OTC flowrate, H2O2 dose,
34
H2O2 dosage method and water matrix. OTC removal efficiencies of 36% and 7% were
35
obtained for a synthetic OTC solution and an urban wastewater fortified with the same OTC
36
concentration, using a H2O2 dose of 15.8 mg/L. Besides providing a good performance using low
37
UVC fluence (34 mJ/cm2) and reactor residence time (4.6 s), the reactor has the advantage of an
38
easy upscaling into a real plant by integrating multiple parallel membranes into a single shell.
O
O
PR
E-
PR
AL
R N
U
JO
39
F
21
40
Keywords: Tube-in-Tube Membrane Microreactor; UVC-H2O2; H2O2 Dosing Method; Process
41
Intensification.
2
JOURNAL PRE-PROOF 1. Introduction
43
The occurrence of organic microcontaminants in aquatic ecosystems has become an emerging
44
concern due to the inability of current treatment methods to remove such compounds [1]. These
45
contaminants of emerging concern (CECs), even in concentrations of nanograms or micrograms,
46
constitute a potential threat to both the ecosystem and human health [2]. Consequently, more
47
efficient wastewater treatment methods are required to reduce the discharge of such compounds
48
into the environment, mainly from urban wastewater treatment plants (WWTPs) [3].
49
The use of advanced oxidation processes (AOPs) in general and particularly the combination of
50
UVC/H2O2 have proved to be a suitable approach for the removal of CECs [4-6]. When
51
combining H2O2 with UVC light, two moles of OH radicals are formed through the photolytic
52
cleavage of one mole of H2O2 that lead to a chain reaction [7, 8], improving the performance of
53
the individual processes [5, 9, 10]. Generally, the photoreactor comprises a cylindrical shell of
54
stainless steel housing concentric quartz sleeves filled with UVC lamps [9, 11, 12]. The
55
wastewater to be treated flows between the concentric tubes (annular reactor) [9, 11]. Oxidant is
56
supplied upstream of the photoreactor inlet, with the help of static mixers, being able to improve
57
the in line mixing of the chemical with the wastewater to be treated [9, 11]. The oxidant
58
concentration decreases along the reactor length, due to its homolytic cleavage by UVC photons
59
and its decomposition with organic and inorganic species present in the wastewater.
60
Consequently, an oxidant concentration profile along the reactor length is observed, generating a
JO
U
R N
AL
PR
E-
PR
O
O
F
42
61
non-homogenous reaction rate inside the photoreactor, limiting the length of reactors to be used
62
in full-scale applications. In order to minimize radial and axial concentration gradients inside the
63
annular reaction zone (ARZ) and thus, maximise the efficiency of the photochemical process,
64
higher doses of oxidant in the feed stream are required. However, an excessive concentration of
3
JOURNAL PRE-PROOF H2O2 can act as a radical scavenger (mainly in the reactor entrance) and higher amounts of
66
residual oxidant are wasted and must be eliminated before the discharge of the treated water into
67
the environment [11, 13]. Consequently, more efficient photoreactor configurations are required
68
to achieve fast reaction rates in the entire annular reactor zone with low residual concentration of
69
chemicals at the reactor outlet. An interesting approach is the use of membrane technology to
70
provide the minimum amount of oxidant necessary for the reaction. Ozonation membrane
71
contacting systems have been used to supply ozone on a continuous basis for water and
72
wastewater treatment, showing high ozone transfer efficiencies [14-16]. However, this type of
73
reactors has been mainly evaluated for chemical synthesis using gas/liquid reactions [17-24]. For
74
example, Cui, et al. [25] proposed a continuous tube-in-tube membrane reactor for the catalytic
75
N-oxidation of alkylpyridines with hydrogen peroxide, inspired by the idea of a tubular reactor
76
with radial distribution of H2O2 given by Pineda-Solano, et al. [26]. No UV lamps were used in
77
this case. A single tube-in-tube model, as well as a multiunit reactor bundle were proposed for
78
real scale applications using a ceramic membrane for the segregated feeding of H2O2. Similarly,
79
a liquid-liquid tube-in-tube semipermeable membrane microreactor was employed by Buba, et
80
al. [27] for the synthesis of N-Methylated amino acids. For this experimental study, a Teflon AF
81
2400 membrane was used as an improved mixing system, injecting the solvent by a syringe
82
pump in the annulus of the reactor.
83
Therefore, this work proposes a disruptive tube-in-tube membrane microreactor for the
JO
U
R N
AL
PR
E-
PR
O
O
F
65
84
photochemical UVC/H2O2 process, allowing a controlled “titration” of small H2O2 doses along
85
the reactor length, resulting in a more homogenous distribution of H2O2 molecules in the annular
86
reaction zone. The efficiency of the photochemical UVC/H2O2 reactor was tested for the
87
oxidation of oxytetracycline (OTC), a commonly antibiotic used as a model CEC, as a function
4
JOURNAL PRE-PROOF of the OTC flowrate, H2O2 dosage (H2O2 stock solution concentration vs H2O2 dosing rate),
89
H2O2 dosage method (radial permeation through the porous inner membrane or supplied
90
upstream of the photoreactor inlet) and water matrix. The idea is to maximise per-pass pollutants
91
conversion, while keeping H2O2 in the reactor outlet at a minimum. This would minimise (or
92
even avoid) the use of subsequent treatment methods needed to remove residual H2O2, as well as
93
the storage capacity and transportation costs of the chemical, maximising the efficient use of
94
H2O2 in real WWTPs.
95
2. Material and methods
96
2.1. Reagents
97
Oxytetracycline hydrochloride (OTC, MW = 496.89, 96% purity, CAS# 2058-46-0) was
98
supplied by ThermoFisher and used as model pollutant. Hydrogen peroxide (HYPE-30P-1K0
99
from Labbox, purity 30% (v/v)) was used as oxidant. Na2SO3 (Merck, p.a.) was added to samples
100
for H2O2 elimination. Ammonium monovanadate (Merck, p.a.) was used to determine H2O2
101
concentration. For OTC analysis by HPLC-DAD, acetonitrile, methanol and oxalic acid
102
dehydrated were supplied by Merck. Pure water (Panice® reverse osmosis system) and ultrapure
103
water (Millipore® Direct-Q system) were used to prepare the synthetic OTC solutions and the
104
mobile phases for HPLC system, respectively. Methylene blue (provided by Merck) was used to
105
prepare the solution for tracer experiments.
106
The real wastewater sample was collected downstream from the secondary treatment of an urban
JO
U
R N
AL
PR
E-
PR
O
O
F
88
107
wastewater treatment plant (WWTP) and kept refrigerated until use. The urban WWTP from
108
Northern Portugal was designed to serve 260,000 population-equivalent with an average flowrate
109
of 43,000 m3/day. Table 1 presents its main physicochemical characteristics. Feed solutions
5
JOURNAL PRE-PROOF 110
used in the experiments were prepared from pure water or the urban wastewater spiked with 2
111
mg OTC per litter. Insert Table 1
112
2.2.
Lab-scale prototype
114
The proposed novel tube-in-tube reactor consists of an inner ceramic ultrafiltration membrane (γ-
115
Al2O3 membrane from Inopor GmbH) and a quartz outer tubing (Figs. 1 and 2). The main
116
characteristics of the tube-in-tube reactor are summarized in Table 2. The tube ends are tightly
117
sealed by two movable polypropylene flanges (Fig. 1a). The membrane outlet is connected to a
118
back-pressure regulator (BPR). The membrane is internally fed with the H2O2 stock solution
119
using a syringe pump (Nexus 6000 from Chemyx Inc.). H2O2 solution permeates through the
120
porous ceramic membrane, and contacts directly with the concurrently fed OTC stream in the
121
annulus (Fig. 3). The bottom and top flanges have inlet and outlet pipes located perpendicularly
122
to the OTC stream flow direction and tangentially to the quartz tube, in horizontal plane and at
123
the top in opposite sides (Fig. 2b). This configuration induces a helical motion of the OTC
124
stream around the membrane shell-side, as can be seen in Fig. 2c using a tracer solution. The
125
fluid movement drags the small H2O2 drops from the membrane shell-side to the bulk of the
126
ARZ. The OTC solution is pumped from a jacketed vessel (connected to a F12-MA chiller from
127
Julabo) to the ARZ using a gear pump (model BVP-Z from Ismatec). Radiation is provided by
128
four UVC lamps (Puritec HNS 6 W G5 from Osram) located externally to the quartz tube and
JO
U
R N
AL
PR
E-
PR
O
O
F
113
129
with a nominal power of 6 W (λmax = 254 nm; useful power = 1.4 W). Photon flow (1.7 W)
130
inside the ARZ was measured by H2O2 (35 mM) actinometry [28] (overall quantum yield, ΦT =
131
1.11, molar absorptivity, P = 18.6 M-1 cm-1, path length, b = 3.85 mm). The setup is surrounded
132
by an aluminium shell to avoid direct eye contact with UVC lamps.
6
JOURNAL PRE-PROOF 133
Insert Figure 1
134
Insert Figure 2
135
Insert Figure 3
136
Insert Table 2 2.3. Experimental procedure
138
The ceramic membrane was internally filled with the H2O2 stock solution, with the BPR fully
139
open. After that, with the BPR fully closed, the syringe pump was used to gradually administer
140
the H2O2 solution, until the first drops of H2O2 appeared in the shell side of the membrane. This
141
indicates that the membrane pores are completely filled with the H2O2 solution. Then, 1 L of
142
pure water was pumped through the ARZ to clean the membrane surface. Subsequently, 5 L of
143
an OTC solution ([OTC]inlet = 2 mg/L; T = 25ºC) was pumped through the ARZ. At the same
144
time, the syringe pump administered the H2O2 stock solution at low dosing rates and UVC lamps
145
were turned on. Samples were collected at different periods until reaching steady state conditions
146
and further analysed in terms of OTC and H2O2 concentration. Immediately after sample
147
collection for OTC analysis, Na2SO3 in a Na2SO3:H2O2 molar ratio of 1:1 was added to quench
148
H2O2.
149
The concentration of hydrogen peroxide in the water flow side at the reactor outlet in the absence
150
of reaction (without OTC), was first evaluated as a function of water inlet flow rate, H2O2 stock
151
solution concentration and H2O2 dosing rate. After that, OTC oxidation tests were performed at
JO
U
R N
AL
PR
E-
PR
O
O
F
137
152
different reaction conditions using the synthetic OTC solution and H2O2 permeation method: i)
153
direct photolysis (no oxidant permeation), ii) only with H2O2 (absence of radiation) and iii)
154
UVC/H2O2. The following operational conditions were tested: OTC solution inlet flow rate
155
(Qinlet,OTC = 10, 20, 40, 60 or 80 L/h), H2O2 stock solution concentration ([H2O2]stock solution = 7.5,
7
JOURNAL PRE-PROOF 156
15 or 30 g/L) and H2O2 dosing rate (0.35, 0.50, 0.70, 1.4, 2.1, 2.8 or 3.5 mL/min). Assays with
157
the real wastewater were performed at the following conditions: Qinlet,OTC = 40 L/h; [H2O2]stock
158
solution
159
The system performance was also evaluated using the conventional oxidant dosing method-
160
supplied upstream of the photoreactor inlet (direct injection). Table 3 presents the experimental
161
conditions used in all UVC/H2O2 tests.
O
F
= 7.5 g/L and H2O2 dosing rate = 1.4 or 2.1 mL/min.
Insert Table 3
O
162
2.4. Analytical procedure
164
OTC concentration was determined by HPLC using a Hitachi ELITE LaChrom (Merck-Hitachi,
165
Tokyo, Japan), equipped with a L-2130 pump, a L-2200 autosampler, a L-2300 column oven, a
166
Purospher® RP-18e 125–4 (5 μm) (Merck) column and a L-2455 DAD. A detailed description of
167
the analytical method can be found elsewhere [29]. H2O2 concentration was determined by the
168
metavanadate method (λ = 450 nm) [30]. Dissolved organic carbon (DOC), chemical oxygen
169
demand (COD), total suspended solids (TSS), volatile suspended solids (VSS), total
170
phosphorous, pH, temperature and turbidity, as well as inorganic anions and cations
171
concentrations were assessed according to the procedures already described by Moreira, et al.
172
[31].
173
3. Results and discussion
174
3.1. H2O2 permeation
JO
U
R N
AL
PR
E-
PR
163
175
Fig. 4 shows the H2O2 concentration profile on the water flow side (annular zone) at the outlet of
176
the tube-in-tube reactor. H2O2 concentration increases with time until steady state conditions
177
after t/ ≥ 90 ( is the space-time inside the illuminated ARZ). The H2O2 steady state
178
concentrations are very similar to the theoretical values considering the annular flow rate, H2O2
8
JOURNAL PRE-PROOF 179
stock solution concentration and H2O2 dosing rate. A similar trend was observed when varying
180
the annular flow rate, H2O2 stock solution concentration and H2O2 dosing rate (data not shown). Insert Figure 4
181
3.2. Effect of the OTC annular flow rate
183
The OTC concentration profiles at the outlet of the tube-in-tube reactor for different H2O2
184
permeation doses, displayed in Fig. 4, show that steady state conditions are obtained after
185
stabilisation of H2O2 in the reactor outlet (t/ ≥ 90), in agreement with the results reported in
186
section 3.1. Therefore, the OTC conversion for all assays will be calculated by taking into
187
account the OTC concentration in the inlet and outlet streams of the tube-in-tube reactor after t/
188
≥ 100, corresponding to an OTC working volume of 5 L.
189
The shaded areas in Fig. 4 correspond to the amount of H2O2 consumed during each reaction for
190
the different H2O2 permeation doses. H2O2 concentration values in the reactor outlet at steady
191
state conditions presents a variation between 0.3 and 2 mg/L, as it can be seen in Table 3.
192
Beyond that, the amount of H2O2 that permeates the membrane pores and reaches the ARZ show
193
also a variation, in average, of 5% between experiments. Therefore, the amount of H2O2 really
194
consumed during the experiments cannot be rigorously calculated. Table 3 shows that a
195
significant fraction (in average 75%) of the initial H2O2 added to the ARZ remains after UVC
196
irradiation at the reactor outlet at steady state conditions. Sarathy, et al. [11] also reported that for
197
an initial H2O2 concentration of 10 mg/L and 0.18 kWh/m3, over 90% of the H2O2 remained in
JO
U
R N
AL
PR
E-
PR
O
O
F
182
198
the water after UVC/H2O2 treatment (Trojan UVSwift™ 4L12 reactor consisting of four
199
medium-pressure mercury vapour lamps with a total power of 11.7 kW).
200
Fig. 5 shows that: i) UVC light (UVC photolysis) was not able to break down efficiently the
201
OTC molecules considering the low space time inside the ARZ; ii) H2O2 molecules (in the
9
JOURNAL PRE-PROOF 202
absence of UVC light) showed an oxidation power over OTC molecules, resulting in a maximum
203
OTC conversion of 12%; iii) the combination of UVC light and H2O2 boosted the OTC oxidation
204
efficiency, achieving values in average of 30%, mainly associated with the generation of
205
hydroxyl radicals. Insert Figure 5
207
Fig. 5 also shows the effect of the annular flow rate (Qinlet,OTC) in the OTC conversion using the
208
same amount of H2O2 injected per unit time (10.5 mg H2O2 per min). The H2O2/UVC process led
209
to higher OTC conversions with the increment of Qinlet,OTC from 10 to 20 L/h (Fig. 5), indicating
210
a change in the hydrodynamic conditions inside the ARZ. A Re number of 1028 (Q = 20 L/h, =
211
9.1 s) allowed to a 1.5-fold increase on OTC conversion compared to a Re of 514 (Q = 10 L/h,
212
= 18.3 s). This can be explained by the poor mixing of H2O2 in the ARZ (the helical motion of
213
water around the membrane shell-side only starts to occur for annular flow rates ≥ 20 L/h),
214
decreasing the efficiency of H2O2 photolysis by the UVC light and further interaction of the
215
reactive species and UVC photons with the OTC molecules, even in the presence of a higher
216
H2O2 residual concentration and higher residence time.
217
A decrease in OTC conversion can be observed for flow rates higher than 40 L/h (Re >2056; <
218
4.6 s). Under these mixing conditions, the limiting factors are the residence time and H2O2
219
concentration in the ARZ. Fig. 6 shows also the effect of the degree of mixing and residence
220
time on OTC oxidation (assay 14: Qinlet,OTC = 40 L/h, [H2O2]stock solution = 7.5 g/L, H2O2 dosing
JO
U
R N
AL
PR
E-
PR
O
O
F
206
221
rate = 1.4 mL/min; assay 9: Qinlet,OTC = 80 L/h, [H2O2]stock solution = 15 g/L, H2O2 dosing rate = 1.4
222
mL/min), considering the same concentration of H2O2 in the annular reaction zone at steady state
223
conditions (15.8 mg/L). A 2.5-fold increase in OTC oxidation efficiency is observed when the
10
JOURNAL PRE-PROOF 224
flow rate decreased from 80 L/h to 40 L/h, showing that under these mixing conditions, the
225
residence time is the limiting factor. Insert Figure 6
227
Therefore, considering the highest OTC conversion (27±3%) at lower residual H2O2
228
concentration, a feed flow rate of 40 L/h was selected for the next set of experiments. However,
229
for Qinlet,OTC = 60 L/h, the addition of 24 mg H2O2 was requested per mg OTC oxidised, against
230
29 mg H2O2 added per mg OTC oxidised for Qinlet,OTC = 40 L/h.
231
3.3. Effect of H2O2 stock solution concentration
232
The effect of H2O2 stock solution concentration in OTC conversion was evaluated by
233
maintaining the amount of H2O2 injected per unit time (10.5 mg H2O2 per min) for a Qinlet,OTC =
234
40 L/h. According to Table 1 (Assays 1, 6 and 14), the OTC conversion remains on average near
235
30% for all conditions. This indicates that the helical motion of water around the membrane
236
shell-side drags rapidly the small H2O2 drops from the membrane shell-side to the bulk,
237
improving the radial mixing homogeneity within the ARZ. This minimises local points near the
238
membrane surface with much higher oxidant concentration than in ARZ bulk.
239
3.4. Effect of H2O2 dosage
240
As concluded by Crittenden, et al. [32], “there exists an optimum hydrogen peroxide dosage for
241
each set of reactor conditions with regard to the organic pollutant removal efficiency of the
242
H2O2/UV process“. Thus, the concentration of H2O2 in the reactor annulus was varied while
JO
U
R N
AL
PR
E-
PR
O
O
F
226
243
maintaining an OTC annular flow rate of 40 L/h (Fig. 6a). This was carried out by modifying the
244
H2O2 stock solution concentration and H2O2 dosing rate. Overall, OTC conversion increases with
245
the increment on H2O2 concentration in the ARZ until 15.8 mg/L. An increment on H2O2 doses
11
JOURNAL PRE-PROOF until 31.5 mg/L led to a similar OTC conversion (Fig. 6a.1). In fact, H2O2 in excess can act as
247
hydroxyl radical scavenger [33, 34].
248
In order to increase the treatment capacity, the OTC inlet flow rate was increased to 80 L/h.
249
Under these conditions, to achieve an OTC conversion near 30%, an H2O2 concentration in the
250
ARZ of 39.4 mg/L was required, resulting in a much higher residual H2O2 concentration (Fig.
251
6b.2).
252
Considering the above and taking into account both OTC conversion and residual H2O2 as
253
reactor performance parameters, the best approach was obtained with a OTC inlet flow rate of 40
254
L/h and H2O2 concentration in the ARZ of 15.8 mg/L.
255
3.5. Effect of H2O2 dosage method
256
The H2O2 radial permeation through the porous inner membrane was compared to the
257
conventional supply of the chemical upstream of the photoreactor inlet (direct injection). The
258
direct injection was carried out using a H2O2 dosing rate of 1.4 mL/min and a H2O2 stock
259
solution of 7.5 g/L. Similar OTC conversion and H2O2 residual concentrations were obtained
260
using both oxidant dosage methods. This can be related to a nearly constant axial oxidant
261
gradient in the ARZ, as a result of the low H2O2 consumption (short reaction time - 4.6 s and low
262
UVC fluence - 34 mJ/cm2). However, in full-scale applications, using powerful UVC lamps, the
263
oxidant is rapidly consumed along the reactor length (> 1 m), due to its homolytic cleavage by
264
UVC photons and its decomposition with organic and inorganic species present in the
JO
U
R N
AL
PR
E-
PR
O
O
F
246
265
wastewater. Consequently, an axial oxidant profile will be generated when using tube lengths in
266
the order of 1 m, resulting in different OTC conversion rates across the reactor length. This
267
behaviour imposes a limit on the reactors length to be used in full-scale applications. In order to
268
minimise radial and axial oxidant gradients inside the ARZ and thus, maximise the efficiency of
12
JOURNAL PRE-PROOF the photochemical process, higher doses of oxidant in the feed stream are required. However, an
270
excessive concentration of H2O2 can act as a radical scavenger mainly in the reactor entrance and
271
higher amounts of residual oxidant are wasted and must be eliminated before the discharge of the
272
treated water into the environment. Therefore, the uniform addition of H2O2 to the reaction zone
273
through “virtually” unlimited dosing points along the membrane shell side can enhance the
274
transformation rate of target contaminants and can also minimise the residual H2O2 concentration
275
in the reactor outlet.
276
3.6. Effect of water matrix
277
In order to test this best approach for real applications, OTC removal by the photochemical
278
UVC/H2O2 system was also evaluated for an urban wastewater after secondary treatment
279
fortified with 2 mg/L of OTC (Fig. 7). Paralleling the reaction rates in both matrices, a
280
substantial decrease in OTC conversion was observed in the presence of the real wastewater,
281
adding the same H2O2 amount to the ARZ (15.8 mg/L). This is mainly related to the presence of
282
light absorbing (low UVC transmittance) and reactive oxygen scavenger species, such as natural
283
organic matter (NOM) and bicarbonates [35]. Although the OTC conversion using the real
284
wastewater almost doubled with the increment on [H2O2]ARZ from 15.8 to 23.6 mg/L, the
285
residual H2O2 concentration increased in a similar extend. Therefore, a much higher amount of
286
oxidant is required to overcome those effects and achieve OTC conversions similar to the
287
synthetic solution. However, it is important to highlight that the aforementioned results were
JO
U
R N
AL
PR
E-
PR
O
O
F
269
288
obtained using a low UVC fluence (45 mJ/cm2), being significantly lower than those used in real
289
treatment plants (600-1000 mJ/cm2) [36]. Insert Figure 7
290 291
4. Conclusions
13
JOURNAL PRE-PROOF This study proves the viability of using tube-in-tube membrane microreactors, with radial
293
addition of H2O2, to promote photochemical UVC/H2O2 oxidation processes for CECs removal
294
from urban wastewaters. The ceramic membrane is internally fed with the H2O2 stock solution;
295
H2O2 permeates through the porous membrane, and contacts with the concurrently fed
296
wastewater in the annulus; resulting in a controlled oxidant “titration” to the ARZ. The helical
297
motion of water around the membrane shell side enhances H2O2 radial dispersion. The more
298
homogenous axial and radial distribution of H2O2 molecules in the ARZ enhances the
299
transformation rate of target contaminants, while keeping H2O2 in the reactor outlet at a
300
minimum.
301
The tube-in-tube membrane microreactor showed an OTC conversion near 36% for a synthetic
302
solution containing an OTC concentration of 2 mg/L, resulting in a residual H2O2 near 14 mg/L
303
(H2O2 dose of 15.8 mg/L). Although lower OTC conversions were observed for an urban
304
wastewater after secondary treatment (fortified with the same amount of OTC), it is important to
305
mention that a low UVC fluence (45 mJ/cm2) was applied when comparing to those used in real
306
treatment plants (600-1000 mJ/cm2).
307
The authors would like to highlight that this type of reactor configuration can be used to promote
308
different chemical, catalytic, electrocatalytic and photo-driven processes, through the dosing of
309
any kind of oxidant (either gas or liquid) or catalyst solutions along the reactor length. At the
310
same time, the proposed set-up could be easily scaled-up by integrating multiple parallel
JO
U
R N
AL
PR
E-
PR
O
O
F
292
311
membranes into a single shell. In order to provide a better light distribution in the ARZ, multiple
312
concentric quartz sleeves filled with UVC lamps can be incorporated parallel to several
313
membranes.
314
Acknowledgements
14
JOURNAL PRE-PROOF This work was financially supported by: i) Project NOR-WATER funded by INTERREG VA
316
Spain-Portugal cooperation programme, Cross-Border North Portugal/Galiza Spain Cooperation
317
Program (POCTEP) and ii) Project POCI-01-0145-FEDER-006984 – Associate Laboratory
318
LSRE-LCM funded by FEDER funds through COMPETE2020 - Programa Operacional
319
Competitividade e Internacionalização (POCI) – and by national funds through FCT - Fundação
320
para a Ciência e a Tecnologia. Vítor J.P. Vilar acknowledge the FCT Individual Call to Scientific
321
Employment Stimulus 2017 (CEECIND/01317/2017).
O
O
F
315
JO
U
R N
AL
PR
E-
PR
322
15
JOURNAL PRE-PROOF References
324
[1] I. Michael, L. Rizzo, C.S. McArdell, C.M. Manaia, C. Merlin, T. Schwartz, C. Dagot, D.
325
Fatta-Kassinos, Urban wastewater treatment plants as hotspots for the release of antibiotics in the
326
environment: a review, Water Res 47 (2013) 957-995.
327
[2] S.D. Costanzo, J. Murby, J. Bates, Ecosystem response to antibiotics entering the aquatic
328
environment, Mar Pollut Bull 51 (2005) 218-223.
329
[3] L. Rizzo, C. Manaia, C. Merlin, T. Schwartz, C. Dagot, M.C. Ploy, I. Michael, D. Fatta-
330
Kassinos, Urban wastewater treatment plants as hotspots for antibiotic resistant bacteria and
331
genes spread into the environment: A review, Science of The Total Environment 447 (2013)
332
345-360.
333
[4] N. De la Cruz, J. Gimenez, S. Esplugas, D. Grandjean, L.F. de Alencastro, C. Pulgarin,
334
Degradation of 32 emergent contaminants by UV and neutral photo-fenton in domestic
335
wastewater effluent previously treated by activated sludge, Water Res 46 (2012) 1947-1957.
336
[5] I. Kim, N. Yamashita, H. Tanaka, Performance of UV and UV/H2O2 processes for the
337
removal of pharmaceuticals detected in secondary effluent of a sewage treatment plant in Japan,
338
Journal of Hazardous Materials 166 (2009) 1134-1140.
339
[6] C. Pablos, J. Marugan, R. van Grieken, E. Serrano, Emerging micropollutant oxidation
340
during disinfection processes using UV-C, UV-C/H2O2, UV-A/TiO2 and UV-A/TiO2/H2O2,
341
Water Res 47 (2013) 1237-1245.
342
[7] O. Legrini, E. Oliveros, A.M. Braun, Photochemical processes for water treatment, Chemical
343
reviews 93 (1993) 671–698.
344
[8] A.S. Stasinakis, Use of selected advanced oxidation processes (AOPs) for wastewater
345
treatment- A mini review, Global NEST Journal 10 (2008) 376-385.
346
[9] N. De la Cruz, L. Esquius, D. Grandjean, A. Magnet, A. Tungler, L.F. de Alencastro, C.
347
Pulgarin, Degradation of emergent contaminants by UV, UV/H2O2 and neutral photo-Fenton at
JO
U
R N
AL
PR
E-
PR
O
O
F
323
348
pilot scale in a domestic wastewater treatment plant, Water Res 47 (2013) 5836-5845.
349
[10] M. Trapido, I. Epold, J. Bolobajev, N. Dulova, Emerging micropollutants in
350
water/wastewater: growing demand on removal technologies, Environ Sci Pollut Res Int 21
351
(2014) 12217-12222.
352
[11] S.R. Sarathy, M.I. Stefan, A. Royce, M. Mohseni, Pilot-scale UV/H2O2 advanced oxidation
353
process for surface water treatment and downstream biological treatment: effects on natural
16
JOURNAL PRE-PROOF organic matter characteristics and DBP formation potential, Environmental Technology 32
355
(2011) 1709-1718.
356
[12] N.G. Wright, D.M. Hargreaves, The use of CFD in the evaluation of UV treatment systems,
357
Journal of Hydroinformatics 3 (2001) 59-70.
358
[13] R.R. Giri, H. Ozaki, Y. Takayanagi, S. Taniguchi, R. Takanami, Efficacy of ultraviolet
359
radiation and hydrogen peroxide oxidation to eliminate large number of pharmaceutical
360
compounds in mixed solution, International Journal of Environmental Science & Technology 8
361
(2011) 19-30.
362
[14] S. Bamperng, T. Suwannachart, S. Atchariyawut, R. Jiraratananon, Ozonation of dye
363
wastewater by membrane contactor using PVDF and PTFE membranes, Separation and
364
Purification Technology 72 (2010) 186-193.
365
[15] P.V. Shanbhag, A.K. Guha, K.K. Sirkar, Single-phase membrane ozonation of hazardous
366
organic compounds in aqueous streams, Journal of Hazardous Materials 41 (1995) 95-104.
367
[16] D.S. Pines, K.-N. Min, S.J. Ergas, D.A. Reckhow, Investigation of an Ozone Membrane
368
Contactor System, Ozone: Science & Engineering 27 (2005) 209-217.
369
[17]
370
alkoxycarbonylation reactions using a prototype reactor in which it is possible to load gas and
371
heat simultaneously, Org Biomol Chem 9 (2011) 6575-6578.
372
[18] U. Gross, P. Koos, M. O'Brien, A. Polyzos, S.V. Ley, A General Continuous Flow Method
373
for Palladium Catalysed Carbonylation Reactions Using Single and Multiple Tube-in-Tube Gas-
374
Liquid Microreactors, European Journal of Organic Chemistry 2014 (2014) 6418-6430.
375
[19] P. Koos, U. Gross, A. Polyzos, M. O'Brien, I. Baxendale, S.V. Ley, Teflon AF-2400
376
mediated gas-liquid contact in continuous flow methoxycarbonylations and in-line FTIR
377
measurement of CO concentration, Org Biomol Chem 9 (2011) 6903-6908.
378
[20] M.A. Mercadante, C.B. Kelly, C. Lee, N.E. Leadbeater, Continuous Flow Hydrogenation
379
Using an On-Demand Gas Delivery Reactor, Organic Process Research & Development 16
380
(2012) 1064-1068.
381
[21] M. O’Brien, I.R. Baxendale, S.V. Ley, Flow Ozonolysis Using a Semipermeable Teflon
382
AF-2400 Membrane To Effect Gas-Liquid Contact, Organic Letters 12 (2010) 1596-1598.
383
[22] G. Wu, A. Constantinou, E. Cao, S. Kuhn, M. Morad, M. Sankar, D. Bethell, G.J.
384
Hutchings, A. Gavriilidis, Continuous Heterogeneously Catalyzed Oxidation of Benzyl Alcohol
O
O
PR
E-
N.E.
Leadbeater,
PR
Mercadante,
Continuous-flow,
palladium-catalysed
JO
U
R N
AL
M.A.
F
354
17
JOURNAL PRE-PROOF Using a Tube-in-Tube Membrane Microreactor, Industrial & Engineering Chemistry Research
386
54 (2015) 4183-4189.
387
[23] L. Yang, K.F. Jensen, Mass Transport and Reactions in the Tube-in-Tube Reactor, Organic
388
Process Research & Development 17 (2013) 927-933.
389
[24] M. Brzozowski, M. O'Brien, S.V. Ley, A. Polyzos, Flow chemistry: intelligent processing
390
of gas-liquid transformations using a tube-in-tube reactor, Acc Chem Res 48 (2015) 349-362.
391
[25] X. Cui, M.S. Mannan, B.A. Wilhite, Segregated-Feed Membrane Reactor Design for
392
Alkylpyridine N-Oxidation: Implications for Process Safety and Intensification, Industrial &
393
Engineering Chemistry Research 56 (2017) 3822-3832.
394
[26] A. Pineda-Solano, L.R. Saenz, V. Carreto, M. Papadaki, M.S. Mannan, Toward an
395
inherently safer design and operation of batch and semi-batch processes: The N-oxidation of
396
alkylpyridines, Journal of Loss Prevention in the Process Industries 25 (2012) 797-802.
397
[27] A.E. Buba, S. Koch, H. Kunz, H. Löwe, Fluorenylmethoxycarbonyl-N-methylamino Acids
398
Synthesized in a Flow Tube-in-Tube Reactor with a Liquid-Liquid Semipermeable Membrane,
399
European Journal of Organic Chemistry 2013 (2013) 4509-4513.
400
[28] H.J. Kuhn, S.E. Braslavsky, R. Schmidt, Chemical actinometry (IUPAC Technical Report),
401
Pure and Applied Chemistry, 2004, pp. 2105.
402
[29] J.C. Espíndola, R.O. Cristóvão, D.A. Mayer, R.A.R. Boaventura, M.M. Dias, J.C.B. Lopes,
403
V.J.P. Vilar, Overcoming limitations in photochemical UVC/H2O2 systems using a mili-
404
photoreactor (NETmix): Oxytetracycline oxidation, Science of The Total Environment 660
405
(2019) 982-992.
406
[30] R.F.P. Nogueira, M.C. Oliveira, W.C. Paterlini, Simple and fast spectrophotometric
407
determination of H2O2 in photo-Fenton reactions using metavanadate, Talanta 66 (2005) 86-91.
408
[31] F.C. Moreira, J. Soler, M.F. Alpendurada, R.A.R. Boaventura, E. Brillas, V.J.P. Vilar,
409
Tertiary treatment of a municipal wastewater toward pharmaceuticals removal by chemical and
410
electrochemical advanced oxidation processes, Water Research 105 (2016) 251-263.
411
[32] J.C. Crittenden, S. Hu, D.W. Hand, S.A. Green, A kinetic model for H2O2/UV process in a
412
completely mixed batch reactor, Water research 33 (1998) 2315-2328.
413
[33] Z. Shu, J.R. Bolton, M. Belosevic, M. Gamal El Din, Photodegradation of emerging
414
micropollutants using the medium-pressure UV/H2O2 Advanced Oxidation Process, Water
415
Research 47 (2013) 2881-2889.
JO
U
R N
AL
PR
E-
PR
O
O
F
385
18
JOURNAL PRE-PROOF [34] W. Zhang, X. Xiao, T. An, Z. Song, J. Fu, G. Sheng, M. Cui, Kinetics, degradation pathway
417
and reaction mechanism of advanced oxidation of 4-nitrophenol in water by a UV/H2O2 process,
418
Journal of Chemical Technology & Biotechnology 78 (2003) 788-794.
419
[35] B.A. Wols, C.H.M. Hofman-Caris, Review of photochemical reaction constants of organic
420
micropollutants required for UV advanced oxidation processes in water, Water Research 46
421
(2012) 2815-2827.
422
[36] C.P. James, E. Germain, S. Judd, Micropollutant removal by advanced oxidation of
423
microfiltered secondary effluent for water reuse, Separation and Purification Technology 127
424
(2014) 77-83.
O
O
F
416
425
JO
U
R N
AL
PR
E-
PR
426
19
JOURNAL PRE-PROOF Figure Captions
428
Figure 1. Photographs of the tube-in-tube reactor a) and respective components (b): 1 -
429
polypropylene flanges; 2 – quartz outer tube; 3 - γ-Al2O3 ultrafiltration membrane inner tube; 4 -
430
UVC lamp.
431
Figure 2. a) Reactor scheme; b) Reactor flanges design; c) Images of the helical motion of the
432
tracer solution (methylene blue dye solution) in the annular reaction zone.
433
Figure 3. Sketch of the proposed setup.
434
Figure 4. a) H2O2 concentration profiles (open symbols) on the water flow (Qinlet,water = 40 L/h)
435
side at the reactor outlet in the absence of UVC light; b) OTC (full symbols) and H2O2 (semi-
436
filled symbols) concentration profiles on the water flow (Qinlet,OTC = 40 L/h) side at the reactor
437
outlet in the presence of UVC light. [H2O2]stock solution = 7.5 g/L; H2O2 dosing rate (mL/min) = 0.7
438
( ,
439
Figure 5. a) Effect of the annular flow rate in the OTC conversion at steady state conditions; b)
440
Residual H2O2 concentration vs Qinlet,OTC: [H2O2]stock
441
mL/min.
442
permeation).
443
Figure 6. Effect of the H2O2 dosage in the ARZ on OTC conversion at steady state conditions
444
for two inlet flow rates: a.1 and a.2: Qinlet,OTC = 40 L/h, [H2O2]stock solution = 7.5 g/L ( ), 15 g/L (
,
); 2.1 ( ,
,
).
AL
); 1.4 ( ,
- UVC/H2O2;
solution
= 15 g/L; H2O2 dosing rate = 0.7
- H2O2 (absence of radiation);
- UVC photolysis (no oxidant
JO
U
R N
,
PR
E-
PR
O
O
F
427
445
), 30 g/L ( ); b.1 and b.2: Qinlet,OTC = 80 L/h, [H2O2]stock solution = 15 g/L ( ).
446
Figure 7. OTC conversion a) and residual H2O2 concentration b) for synthetic ( ) and real
447
matrices ( ) fortified with 2 mg OTC per liter at steady state conditions: Qinlet,OTC = 40 L/h;
448
[H2O2]stock solution = 7.5 g/L; H2O2 dosing rate = 1.4 or 2.1 mL/min.
20
JOURNAL PRE-PROOF Figures
450
Figure 1
E-
PR
O
O
F
449
PR
451
JO
U
R N
AL
452
21
JOURNAL PRE-PROOF Figure 2
454
JO
455
U
R N
AL
PR
E-
PR
O
O
F
453
22
JOURNAL PRE-PROOF Figure 3
PR
E-
PR
O
O
F
456
AL
457
460 461
JO
462
U
459
R N
458
463 464 465 466
23
JOURNAL PRE-PROOF Figure 4
45 40
0.8
35 23.6 15.8
0.2
7.9
O O
0.4
25
PR
0.6
F
30
0.0 20
40
60
PR
0
E-
[OTC]Outlet/[OTC]Inlet
1.0
[H2O2]Outlet (mg/L)
467
80
20 15 10 5 0
100
AL
t/
468
JO
U
R N
469
24
JOURNAL PRE-PROOF Figure 5
30 20 10 0
10
20 40 60 QInlet,OTC (L/h)
80
O
30
F
80
(b)
40
O
(a)
PR
20 10 0 20
40
PR
10
E-
1-[OTC]Outlet/[OTC]Inlet (%)
100
[H2O2]Residual (mg/L)
470
60
80
AL
QInlet,OTC (L/h)
471
JO
U
R N
472
25
JOURNAL PRE-PROOF Figure 6 Qinlet,OTC = 40 L/h
F
30
1-[OTC]Outlet/[OTC]Inlet (%)
90
40 30
O
20
O
20 10
PR
0
(b.2)
(a.2)
20
10 5 7.9
15.8
22.5
23.6
[H2O2]ARZ (mg/L)
30 25 20
7.9
15 10 5 15.8
23.6
31.50
39.4
0
[H2O2]ARZ (mg/L)
JO
U
R N
474
31.5
0
35
PR
15
10
40
E-
25
0
475
100
(b.1)
90
30
[H2O2]Residual (mg/L)
(a.1)
AL
1-[OTC]Outlet/[OTC]Inlet (%)
100
Qinlet,OTC = 80 L/h
[H2O2]Residual (mg/L)
473
26
JOURNAL PRE-PROOF 476
Figure 7
100
50
20 15 10
F
90
(b)
25
5 0
O
[H2O2]Residual (mg/L)
15.8
40
23.6
O
[H2O2]ARZ (mg/L)
PR
30 20 10 0
PR
15.8
E-
1-[OTC]Outlet/[OTC]Inlet (%)
(a)
23.6
[H2O2]ARZ (mg/L)
AL
477
JO
U
R N
478
27
JOURNAL PRE-PROOF 479
Tables
480 481
Table 1. Main physicochemical characteristics of the real wastewater sample collected after the secondary settling tank of an urban WWTP. Parameters (units) Pale yellow
Odor
n.d.a
Turbidity (NTU)
7.1
pH
8.1
Temperature (°C)
24
O
O 285
PR
Alkalinity (mg CaCO3/L)*
F
Color
23.4
Chemical oxygen demand (mg/L)
117
Transmittance at 254 nm (%)
54
E-
Dissolved organic carbon (mg/L)
2.7
Volatile suspended solids (mg/L)
0.68
PR
Total suspended solids (mg/L)
1.1
Nitrite – N-NO2- (mg/L)
0.2
Nitrate – N-NO3- (mg/L)
< 0.1
Chloride – Cl- (mg/L)
167
Sulfate – SO42- (mg/L)
78
Phosphate – PO43- (mg/L)
12.6
Total Phosphorous – P (mg/L)
4.1
U
*Alkalinity value considering that for the pH of the wastewater, the inorganic carbon is mainly in the form of bicarbonate; n.d. – not detected.
JO
482 483 484
R N
AL
Ammonium – N-NH4+ (mg/L)
28
JOURNAL PRE-PROOF Table 2. Characteristics of the tube-in-tube reactor. Components
Characteristics Ø External Ø Internal Total length Illuminated length
3.2 cm 2.8 cm 20 cm 17.4 cm
Ultrafiltration membrane γ–Al2O3 (Cut-off: 20 kDa)
Ø External Ø Internal Total length Illuminated length Pore size Porosity
2.03 cm 1.55 cm 20 cm 17.4 cm 10 nm 30 - 55 %
ARZ volume
Total Illuminated
ENominal power Useful power Number of lamps
58.4 cm3 50.8 cm3 6W 1.4 W 4
U
R N
AL
PR
UVC lamp (Puritec HNS 6 W G5, λmax = 254 nm)
PR
O
O
F
Quartz tube
29
JOURNAL PRE-PROOF
[H2O2]ARZ (mg/L)
0.35
15.8
0.50
22.5
0.70
31.5
Synthetic OTC solution
15
7.5
UW fortified with OTC
26
31±2
10±2
1
40
28±1
16±2
2
48
33±2
21.8±0.3
3
18±3
41±1
4
27±4
25±2
5
29
27±3
10±3
6
24
22±3
6.8±0.5
7
52
8±1
2.4±0.7
8
74
11±3
10±0.5
9
49
24±4
18.9±0.5
10
58
27±1
27±2
11
59
33±1
36.7±0.5
12
25
16±3
5.6±0.7
13
22
36±2
14.3±0.7
14
36
32±2
22.8±0.3
15
121
6.5±0.5
12±1
16
97
12±1
21±2
17
30
39±2
16±3
18
4.6
2056
10
18.3
514
171
31.5
20
9.1
1028
59
15.8
40
4.6
2056
10.5
60
3.0
3084
7.9
80
2.3
4112
15.8
2.1
23.6
2.8
31.5
3.5
39.4
0.70
7.9
1.4
15.8
2.1
23.6
2.1
Experiment number
63.0
1.4
1.4
7.5
[H2O2]Residual (mg/L)
80
2.3
40
4.6
15.8 23.6
40
4.6
O
0.70
Efficiency (%)
O
15
40
mgH2O2/mgOTC
4112
E-
30
QInlet,OTC τ (s) Re (L/h) Radial Permeation
F
H2O2 dosing rate (mL/min)
PR
[H2O2]stock solution (g/L)
PR
Table 3. Experimental conditions used in all UVC/H2O2 tests.
2056
2056
AL
Direct Injection
1.4
R N
7.5
U
Synthetic OTC solution
15.8
40
4.6
2056
30
E-
PR
O
O
F
JOURNAL PRE-PROOF
Highlights
PR
- Tube-in-tube membrane microreactor for photochemical UVC/H2O2 oxidation systems; - Radial addition of H2O2 through the porous membrane into the annular reaction zone;
AL
- “Virtually” unlimited number of H2O2 dosing points across the membrane length; - Helical motion of water around the membrane shell-side enhances H2O2 radial mixing;
U
R N
- More homogenous axial and radial distribution of H2O2 in the annular reaction zone.
31
U
R N
AL
PR
E-
PR
O
O
F
JOURNAL PRE-PROOF
32