Experimental Thermal and Fluid Science xxx (2014) xxx–xxx
Contents lists available at ScienceDirect
Experimental Thermal and Fluid Science journal homepage: www.elsevier.com/locate/etfs
Erratum
Erratum to ‘‘Convective vaporization in micro-fin tubes of different geometries’’ [Exp. Therm. Fluid Sci. 44 (2013) 398–408] Zan Wu a, Yang Wu b, Bengt Sundén a,⇑, Wei Li c a
Department of Energy Sciences, Lund University, Box 118, Lund SE-22100, Sweden Shanghai Longyang Precise Copper Tube Co., Ltd., Shanghai 201201, PR China c Department of Energy Engineering, Zhejiang University, Hangzhou 310027, PR China b
The authors regret that the printed version of the above article contained errors in Eq. (26). The correct formula for Eq. (26) should have an exponent of 1/3 on the right hand side as follows: 3
3 1=3
h ¼ ½ðhcv Þ þ ðhnb Þ
3
3 1=3
¼ ½ðERB hcb;l Þ þ ðS hpb Þ
ð26Þ
DOI of original article: http://dx.doi.org/10.1016/j.expthermflusci.2012.07.012
⇑ Corresponding author. Tel.: +46 46 2228605; fax: +46 46 2224717. E-mail address:
[email protected] (B. Sundén). http://dx.doi.org/10.1016/j.expthermflusci.2014.02.020 0894-1777/Ó 2014 Elsevier Inc. All rights reserved.
Please cite this article in press as: Z. Wu et al., Erratum to ‘‘Convective vaporization in micro-fin tubes of different geometries’’ [Exp. Therm. Fluid Sci. 44 (2013) 398–408], Exp. Therm. Fluid Sci. (2014), http://dx.doi.org/10.1016/j.expthermflusci.2014.02.020