Applied Energy 255 (2019) 113789
Contents lists available at ScienceDirect
Applied Energy journal homepage: www.elsevier.com/locate/apenergy
Thermo-physical properties of CO2 mixtures and their impacts on CO2 capture, transport and storage: Progress since 2011
T
⁎
Hailong Lia,b, , Beibei Donga, Zhixin Yuc, Jinyue Yanb, Kai Zhua a
Key Laboratory of Refrigeration Technology of Tianjin, Tianjin University of Commerce, Tianjin 300134, China School of Business, Society & Engineering, Mälardalen University, Västerås SE-72123, Sweden c Department of Energy and Petroleum Engineering, University of Stavanger, 4036 Stavanger, Norway b
H I GH L IG H T S
experimental data and theoretical models on thermo-physical properties of CO • The new knowledge gaps regarding measurements are identified. • The performance of different property models are presented. • The • The property impacts on carbon capture and storage are updated.
2
mixtures since 2009 are updated.
A R T I C LE I N FO
A B S T R A C T
Keywords: CO2 capture transport and storage Thermo-physical properties Experimental data Modeling Property impacts
The knowledge of accurate thermo-physical properties is crucial for the development and deployment of CO2 capture, transport and storage (CCS). The progress on the experimental data and theoretical models regarding thermo-physical properties of CO2 mixtures as well as the property impact on the design and operation of different CCS processes has been updated. The newly published experimental data since 2011 have been collected and reviewed based on which the new knowledge gaps regarding measurements have been identified. There have also been some advanced models proposed recently, which have shown good performances. The collected model performances don’t show there exist a model that is superior to others; but they still provide a good guideline regarding model selection. However, developing more-complex models as the complexity may not necessarily improve the accuracy when empirical parameters were included and well-tuned. By comparing the importance of the properties and the accuracy of existing models, suggestions were given regarding the development of property models that should be prioritized.
1. Introduction The latest 2018 Special Report on Global Warming of 1.5 °C by the Intergovernmental Panel on Climate Change (IPCC) indicated that in order to realize net-zero emissions by 2050, it requires to capture at least 4 Gt/year of CO2 in 2040 and 8 Gt/year in 2050 [1–3]. CO2 capture and storage (CCS) is playing a key role, which is the only option capable of decarbonizing major industrial sectors, particularly the power, steel and iron, cement and petrochemical industries [1]. CCS comprises of CO2 capture, which technologies are mainly divided into three categories including post-combustion capture, pre-combustion capture and oxy-fuel combustion capture, CO2 transport and CO2 storage [4]. Significant efforts have been dedicated to the research and development (R&D) of CCS technologies and some commercial
⁎
demonstration projects have been launched globally [1]. Clear progresses have been made in the R&D. For example, from the technical perspective, new solvents have been developed, which can reduce the energy penalty to 1.83 GJ/tCO2 [5]; from the economic perspective, the cost of CCS continues to decrease, which can currently reach 20 USD/ tCO2 [6], as more facilities have been commercialized; and from the policy perspective, a growth in CCS policy confidence across multiple country jurisdictions can be seen, such as the enactment of 45Q (tax credit) legislation in US and the CCUS Cost Challenge Taskforce in UK [1]. In addition, CO2 utilization, which can convert CO2 into valueadded products, has also attracted much attention. International Energy Agency (IEA) findings reported that the potential of CO2 utilization could contribute 14% to Paris climate targets of 2 °C by 2060, up to 32% in the transition between the 2 °C scenario (2DS) to the beyond
Corresponding author. E-mail address:
[email protected] (H. Li).
https://doi.org/10.1016/j.apenergy.2019.113789 Received 27 March 2019; Received in revised form 19 August 2019; Accepted 26 August 2019 0306-2619/ © 2019 Elsevier Ltd. All rights reserved.
Applied Energy 255 (2019) 113789
H. Li, et al.
CO2 mixtures, more measurements are available, such as VLE of CO2/ Ar/O2, CO2/SO2/O2 [17] and CO2/N2/H2 [20], which are very important for the calibration and validation of theoretical models.
2 °C scenario [1]. The objectives of R&D of CCS are primarily focused on the issues about energy efficiency, cost and safety. It has been well recognized that the design and operation of CCS systems rely on a deeper understanding of the thermo-physical properties of CO2 and CO2 mixtures, which enables the correct estimation of the characteristics of separated streams, the sizing of equipment and the operating conditions of different processes [2,3,7,8]. The key properties include thermodynamic properties such as vapor liquid equilibrium (VLE) and densities; and transport properties such as viscosity, thermal conductivity and diffusivity. In our previous review works published in 2011, the possible impurities from different CCS processes and applications were identified [7], the corresponding operating conditions were collected and the state of the art about the research on thermodynamic properties [7] and transport properties [8] of CO2 and CO2 mixtures was presented respectively. Some important knowledge gaps were identified in both experimental works and modeling studies. Meanwhile, Munkejord et al. [9] investigated the properties needed in CO2 transport, such as phase behavior, density, speed of sound, viscosity, and thermal conductivity. In addition to VLE, vapor-liquid-liquid equilibrium (VLLE) and equilibrium involving solids and hydrates were also included. Furthermore, understanding the impacts of properties on the design and operation of different CCS processes is essential to prioritize the research work about properties. The higher the impact is, the more important the property is. We have also performed a systematic study [10] to review the impacts of thermo-physical properties on different processes and technologies of CCS, including CO2 capture, conditioning, transport and storage. It was concluded that the most important properties are different for different processes. Due to the lack of studies and process complexity, the impacts on some processes still remain unclear. For example, there has been no study about the property impact on physical absorption, physical adsorption and membrane separation; and for the influence of liquid properties on the design of chemical absorption, little information is available. With the advancement of measuring technologies and the increasing attention on the fundamental properties, many new experimental data have been published, which have bridged some of the identified knowledge gaps. Meanwhile, with the development of computer technologies, new models are also emerging. The objective of this review is to update the status regarding the studies on thermo-physical properties of CO2 and CO2 mixtures since 2011 with special attentions paid to the development of property models. In addition, this work will also summarize the progress in assessing the property impacts on CCS processes. The remainder of the paper is organized as follows: Sections 2 and 3 present the latest progresses in the experimental study and modeling work on the thermo-physical properties of CO2 mixtures; the impacts of properties on CCS processes are updated in Section 4; and finally, the knowledge gaps and key findings are concluded in Section 5.
2.1.2. Density Table 3 presents the progress in the experimental data on density. New data have been published for CO2/O2 [21,22], CO2/COS [23], CO2/CO [22,24,25], CO2/N2O4 [19], CO2/H2 [22,26,27], CO2/Ar/N2 [28,29] and CO2/N2/O2/Ar [30]. But some clear gaps still exist. For example, there are no data for CO2/NH3, no vapor density for CO2/O2 and CO2/N2O4, and few data for CO2/H2S, CO2/SO2 and CO2/Ar at temperatures lower than 273 K. More data are also needed for CO2/ N2O. 2.2. Transport properties New data about transport properties published since 2011 are summarized in Table 4 and compared to the previously identified data gaps in Table 5. More data about the viscosity of pure CO2 in the supercritical phase have been published by Heidaryan et al. [31] and Al-Siyabi [22] as a supplement to previous data, which mainly contain gas and liquid phases. More measurements about viscosity have been conducted for liquid mixtures, such as CO2/O2, CO2/H2, CO2/Ar, CO2/CO [22], CO2/ O2/N2/Ar [32], and CO2/O2/N2/Ar/H2/CO/CH4 [22,32] besides aqueous solutions of 4 amines [33] and CO2/H2O [34]. Moreover, data at high pressures become available, such as the viscosity of CO2/O2 and CO2/CO [22] at pressures up to 50 MPa, and the diffusivity of CO2/H2O [35,36] at pressures up to 45 MPa. In general, the study on transport properties is still far behind that on thermodynamic properties. It can be clearly seen in Table 5 that not many data are available; and even though some data exist for a couple of CO2 mixtures, they are in narrow temperature and pressure ranges. For example, the thermal conductivity and diffusivity data are not yet available for most liquid CO2 mixtures, except for CO2/H2O (/NaCl) and CO2/amine solutions. There are no data about any transport property for CO2/H2S, CO2/COS and CO2/NH3. For multi-component CO2 mixtures, only some data are available for CO2/O2/N2/Ar and CO2/O2/N2/Ar/H2/CO/CH4. The slow progress in the experimental study of transport properties is mainly due to the difficulty of measurements caused by the wide ranges of temperature and pressure. New techniques may be needed to have a major breakthrough. 3. Progress on modeling Different from our previous review papers [7,8], a more comprehensive comparison on the performance of models was presented in this work. Regarding different CO2 mixtures, the quantitative accuracy about different properties was provided at given temperatures and pressures. In addition, progress has also been made in the development of advanced models due to the progress in the experimental study and the development of computer technologies. The available models about thermodynamic properties and transport properties are summarized and compared in Tables 6 and 7.
2. Progress in experimental studies about the thermo-physical properties of CO2 mixtures 2.1. Thermodynamic properties New data about thermodynamic properties, including VLE and density, published since 2011 have been collected from the literature and summarized in Table 1. They are also compared with the data gaps identified in our previous review paper [7] in Table 2 and Table 3.
3.1. Thermodynamic property models 3.1.1. Newly developed models
2.1.1. Phase equilibrium As shown in Table 2, it is clear that some gaps about phase equilibrium have been bridged. For example, for CO2/Ar [11–15] and CO2/ CO [16], more data are available and there are no clear gaps; for CO2/ SO2 [2,3,17,18] and CO2/N2O4 [19], even though there are some new data, data at temperatures below 263 K are still missing. For CO2/COS and CO2/NH3, no new data have been published. For multi-component
- GERG-2008 GERG-2008 is an updated version of GERG-2004 [7], which was proposed by Kunz and Wagner (2012) [37]. Compared to GERG-2004, three new components, n-nonane, n-decane and hydrogen sulfide are added. The validity range has extended to temperatures from 60 to 2
Applied Energy 255 (2019) 113789
H. Li, et al.
Table 1 New experimental data on VLE and density of CO2 mixtures since 2011. Year
Type
2011 2011 2012 2012 2013 2013 2013 2013 2014 2014 2014 2014 2015 2015 2015 2015 2016 2016 2016 2016 2016 2016 2016 2016 2016 2017 2017 2017 2017 2017 2017 2017 2018 2018 2018 2018 2019
VLE and Density Density Density Density Density Density Density VLE VLE VLE VLE VLE VLE Density Density VLE and VLE VLE VLE Density VLE Density Density Density VLE and VLE and VLE and Density VLE and VLE and Density VLE VLE VLE VLE and Density
density
density
density density density density density
density
Mixture
T (K)
P (MPa)
Uncertainty
Refs.
CO2/NO2, CO2/N2O4 CO2/N2 CO2/N2 CO2/N2, CO2/O2, CO2/Ar CO2/N2/O2/Ar/H2O CO2/N2, CO2/O2, CO2/Ar, CO2/CO, CO2/H2, CO2/CH4 CO2/H2 CO2/CH4, CO2/CO CO2/SO2 CO2/NO CO2/O2/Ar, CO2/SO2/O2 CO2/O2, CO2/N2 CO2/Ar, CO2/CH4 CO2/N2, CO2/H2 CO2/N2, CO2/H2, CO2/N2/H2 CO2/Ar, CO2/N2 CO2/Ar/N2 CO2/H2S CO2/N2 CO2/O2 CO2/Ar CO2/Ar CO2/O2, CO2/N2, CO2/Ar CO2/CH4 CO2/Ar CO2/COS CO2/SO2 CO2/CH4/N2/H2/O2/Ar/CO, CO2/N2/O2/Ar, CO2/CH4/C2H6/C3H8/C4H10 CO2/Ar CO2/H2 CO2/Ar/N2, CO2/Ar/H2 CO2/SO2 CO2/CH4 CO2/CO CO2/Ar CO2/CH4 CO2/SO2 CO2/CO
298.00–328.45 250.00–400.00 250.00–400.00 303.00–383.00 243.15–423.15 283.15–423.15 288.15–333.15 304.21–308.15 263.15–333.21 232.93–273.15 253.00–293.00 277.35–302.15 218.15–303.15 252.00–304.00 298.15–423.15 323.15–423.15 273.00–353.00 223.00–303.00 218.00–298.00 252.95–280.44 273.15–323.15 223.00–293.00 300.15–313.15 273.15–323.15 322.91–393.25 273.00–353.00 273.00–423.00 257.54–291.13 273.15–323.15 268.00–333.00 263.00–473.00 300.00–308.15 253.00–298.00 213.00–299.00 293.13–303.15 263.00–423.00 255.05–313.28
1.000–9.000 1.970–19.990 0.490–19.980 1.000–20.000 1.000–150.000 < 50.000 < 23.000 0.100–20.000 0.100–8.000 1.000–11.500 1.900–7.600 4.100–7.930 0.560–15.440 2.060–10.570 11.000–31.000 3.000–31.000 0.300–41.400 0.680–18.220 0.550–14.410 2.830–6.940 0.480–8.990 0.700–16.530 8.000–10.000 0.500–9.100 2.500–35.000 0.050–41.700 1.000–126.000 2.410–6.010 0.510–5.990 3.100–23.000 0.100–70.000 2.000–18.000 1.970–12.600 2.540–16.000 0.270–8.740 0.100–70.000 2.000–8.000
T: ± 0.1 K; P: ± 0.075 MPa T: 0.0039 K; P: 0.015% T: 0.004 K; P: 0.015% T: ± 0.05 K; P: ± 0.03% T: ± 0.1 K; P: ± 0.05 MPa T: ± 0.01 K T: ± 0.05 K; P: ± 0.0035 MPa T: ± 0.006 K; P: 0.008 MPa T: 0.02 K; P: 0.002 MPa T: 0.02 K; P: 0.002 MPa T: 0.02 K; P: 0.002 MPa – T: 0.006 K; P: 0.003 MPa T: 0.1 K; P: 0.007 MPa T: ± 0.035 K; P: ± 0.00339 MPa T: ± 0.035 K; P: ± 0.0034 MPa T: ± 0.01 K; P: ± 0.02 MPa T: ± 0.006 K; P: ± 0.003 MPa T: ± 0.008 K; P: ± 0.003 MPa T: ± 0.02 K; P: ± 0.01% T: ± 0.0025 K; P: ± 0.0035% T: ± 0.05 K; P: ± 0.008 MPa T: 0.035 K; P: 0.0034 MPa T: ± 0.0025 K; P: ± 0.0035% T: 0.005 K; P: 0.0052% T: ± 0.02 K; P: ± 0.002 MPa T: ± 0.02 K; P: ± 0.02 MPa T: ± 0.02 K; P: ± 0.0001 MPa T: 0.0025 K; P: ± 0.0035% T: 0.02 K; P: 0.007 MPa T: 0.006 K; P: 0.018 MPa T: 0.02 K; P: 0.001 MPa T: ± 0.009 K; P: ± 0.003 MPa T: 0.013 K; P: 0.0032 MPa T: 0.003 K; P: 0.002 MPa T: 0.006 K; P: 0.018 MPa T: 0.02 K; P: 0.138 MPa
[19] [70] [71] [21] [72] [22] [26] [24] [17] [17] [17] [11] [73] [20] [53] [28] [40] [74] [75] [12] [41] [13] [76] [77] [23] [18] [30] [14] [27] [29] [2] [78] [16] [15] [38] [3] [25]
Table 2 Knowledge gaps on VLE. Mixture CO2/Ar CO2/CO CO2/SO2 CO2/NO2 (N2O4) CO2/NO CO2/NH3
Previously identified gaps New data [11–15] Previously identified gaps New data [16] Previously identified gaps New data [2,3,17,18] Previously identified gaps New data [19] Previously identified gaps New data [17] Previously identified gaps New data
[7] [7] [7] [7] [7] [7]
T (K)
P (MPa)
xa
yb
Gaps
218.15–233.15, 288.15–303.15 213.15–300.35 283.15–303.15 253.15–298.16 218.15–295.15 263.15–333.21 218.15–262.15, 293.15–303.15 298.15–328.45 218.15–303.15 232.93–273.15 218.00–413.15 NA
< 4.400 0.689–15.097 < 2.390 1.970–12.540 < 2.120 and > 6.430 0.104–8.785 > 0.670 1.000–8.970 0.500–10.000 1.000–11.500 0.500–4.250
0–0.690 0.492–0.990 0–0.631 0.626–0.999 0–1.000 0.030–0.897 Xc: 0.021–1.000 X: 0.072–0.937 0–1.000 0.527–0.984 X: 0.333–1.000
0–0.266 0.131–0.961 0.827–1.000 0.426–0.999 0–0.750 0.208–0.985
No gaps
0–1.000 0.234–0.849
Previously identified gaps [7] New data
218.15–303.15 NA
0.500–10.000
0–1.000
0–1.000
CO2/Ar/O2
Previously identified New data [17] Previously identified New data [17] Previously identified New data [20] Previously identified New data [29] Previously identified New data [29]
218.15–303.15 253.28–293.21 218.15–303.15 253.28–293.24 218.15–303.15 252.80–301.50 218.15–303.15 267.94–302.50 218.15–303.15 267.97–301.59
0.500–10.000 2.327–7.638 0.500–10.000 1.935–6.473 0.500–10.000 2.140–9.820 0.500–10.000 3.100–8.960 0.500–10.000 3.260–9.080
0–1.000 0.942–0.991 0–1.000 0.002–0.025 0–1.000 X: 0.930–0.950 0–1.000 X: 0.900–0.980 0–1.000 X: 0.950
0–1.000 0.536–0.921 0–1.000 0.035–0.323 0–1.000
CO2/SO2/O2 CO2/N2/H2 CO2/Ar/N2 CO2/Ar/H2
a b c
gaps [7] gaps [7] gaps [7] gaps [7]
: x means liquid mole fraction of carbon dioxide. : y means vapor mole fraction of carbon dioxide. : X means the total mole fraction of carbon dioxide. 3
T: 218.15–263.15 K T: 218.15–262.15 K
CO2/COS
gaps [7]
x: 0–0.631
0–1.000 0–1.000
T: 273.15–303.15 K; x: 0–0.527 T: 218.00–413.15 K; P: 0.500–4.250 MPa; x: 0.333–1.000 T: 218.15–303.15 K; P: 0.500–10.000 MPa; x/y: 0–1.000 T: 218.15–253.28 K; x: 0–0.942 T: 218.15–253.28 K; x: 0.025–1.000 T: 218.15–252.80 K T: 218.15–267.94 K; x: 0–0.900 T: 218.15–267.97 K; x: 0–0.950
Applied Energy 255 (2019) 113789
H. Li, et al.
Table 3 Knowledge gaps on density. Mixture CO2/O2 CO2/COS CO2/CO CO2/NO2(N2O4) CO2/H2 CO2/H2S CO2/SO2 CO2/Ar CO2/N2O CO2/NH3
CO2/Ar/N2 CO2/N2/O2/Ar
T (K)
P (MPa)
Phase*
Gaps
Previously identified gaps [7] New data [21,22] Previously identified gaps [7] New data [23] Previously identified gaps [7] New data [22,24,25] Previously identified gaps [7] New data [19] Previously identified gaps [7] New data [22,26,27] Previously identified gaps [7] New data [40] Previously identified gaps [7] New data [2,3,18] Previously identified gaps [7] New data [14,21,22,41,53] Previously identified gaps [7] New data Previously identified gaps [7] New data
218.00–1620.00 283.15–423.15 218.00–1620.00 322.91–393.25 218.00–1620.00 255.05–423.15 218.00–1620.00 298.00–328.45 218.00–278.00, 290.00–1620.00 273.15–423.15 218.00–275.00, 306.00–1620.00 273.15–353.15 218.00–278.00, 347.00–1620.00 263.15–473.15 218.00–288.00, 303.00–1620.00 273.15–423.35 218.00–293.00, 307.00–1620.00 NA 218.00–1620.00 NA
0–50.000 1.003–47.790 0–50.000 2.500–35.000 0–50.000 2.000–48.550 0–50.000 1.000–9.000 0–4.800, 19.200–50.000 0.503–49.240 0–3.500,6.990–50.000 0.300–41.400 10.640–50.000 0.051–70.000 0–7.510, 9.780–50.000 0.455–57.770 0–5.300, 7.100–50.000
L. + G. L. (Sc.) L. + G. L. + G. L. + G. L. + G. (Sc.) L. + G. L. (Sc.) G. L. + G. (Sc.) NA L. NA L. + G. NA L. (Sc.) NA
T: 218.00–283.00 K; Phase: G. T: 218.00–322.00 K
0–50.000
L. + G.
Previously identified gaps [7] New data [28,29] Previously identified gaps [7] New data [30]
218.00–1620.00 268.15–423.15 218.00–1620.00 273.15–423.15
0–50.000 1.510–30.954 0–50.000 1.070–126.000
L. + G. L. + G. (Sc.) L. + G. L. + G. (Sc.)
T: 218.00–255.00 K T: 218.00–298.00 K Phase: G. T: 218.00–278.00 K T: 218.00–275.00 K T: 218.00–278.00 K T: 218.00–273.00 K T: 218.00–293.00 K, 307.00–1620.00 K; P: 0–5.300 MPa, 7.100–50.000 MPa T: 218.00–1620.00 K; P: 0–50.000 MPa; Phase: L. + G. T: 218.00–293.00 K T: 218.00–273.00 K
* G.: gas; L.: liquid; and Sc.: supercritical. Table 4 New experimental data on the transport properties of CO2 and CO2 mixtures since 2011. Year
Phase
Mixture
T/K
P/MPa
Uncertainty
No. of data
Refs.
Viscosity 2011 Sc.a
Pure CO2
313.15–523.15
7.700–81.1 00
102
[31]
2012
G.
Pure CO2
309.82–388.71
27.580–55.160
45
[79]
2015
G.
Pure CO2
253.15–473.15
< 1.200
54
[80]
2013
L. + Sc.
280.00–343.15
L. + G. + Sc.
243.00–423.00
7.150–48.100 8.730–48.260 8.750–48.290 7.750–50.390 8.900–53.790 6.500–50.100 10.680–51.210 1.000–150.000
50 51 60 48 56 54 54 42
[22]
2013
Pure CO2 CO2/H2 CO2/O2 CO2/Ar CO2/CO CO2/CH4 CO2/H2/CH4/N2/CO/Ar/O2 CO2/O2/N2/Ar/H2O
T: ± 0.02 K; P: ± 0.1%; Viscosity: ± 0.2% T: ± 0.556 K; P: ± 0.007 MPa; Viscosity: ± 1% T: 0.109 K; P: 0.001 MPa; Viscosity: 0.20–0.41% T: ± 0.01 K; P: ± 0.05 MPa; Viscosity: ± 1%
2013
G.
CO2/CH4
310.93–455.37
34.500–172.400
168
[81]
2014
L.
CO2/H2O
274.00–449.00
< 100.000
71
[34]
2015
G.
CO2/CH4
229.00–348.00
1.000–32.000
119
[82]
2017 2018
L. L. + G. + Sc.
MDEA, DMEA, DEEA, MAPAb/H2O/CO2 CO2/O2/N2/Ar/H2/CO/CH4, CO2/O2/N2/Ar, CO2/alkane,
293.00–353.00 243.00–423.00
– 1.000–155.000
171 153
[33] [32]
Thermal conductivity 2014 L. + G.
Pure CO2
219.00–751.00
< 69.000
T: 0.005 K; P:0.007 MPa; Thermal conductivity: 0.5% (3%*)
–
[83]
Diffusivity 2013 L. 2014 L.
CO2/H2O CO2/H2O
268.00–473.00 298.15–423.15
0–45.000 15.000–45.000
T: ± 0.2 K; P: ± 0.14% T: 0.01 K; Diffusivity: 2.3%
17 17
[35] [36]
a
T: ± 0.1 K; P: 0.05 MPa; Viscosity: ± 1% T: ± 0.556 K; P: ± 0.007 MPa; Viscosity: ± 1% T: 0.025 K; P: 0.1 MPa; Viscosity: 1.4% T: 0.005 K; P: 0.004 MPa; Viscosity: 0.8% T: ± 0.03 K T: 0.1 K; P: ± 0.02 MPa
: Supercritical phase. : MDEA: N-Methyldiethanolamine; DMEA: N, N-Dimethylethanolamine; DEEA: Diethylethanolamine; MAPA: N-Methyl-1,3-diaminopropane. * : In the supercritical area.
b
4
[72]
Applied Energy 255 (2019) 113789
H. Li, et al.
Table 5 Knowledge gaps on the transport properties. Mixture Viscosity Pure CO2 CO2/O2 CO2/CO CO2/CH4 CO2/H2 CO2/Ar
CO2/H2O CO2/O2/N2/Ar /H2O MDEA or DMEA or DEEA or MAPA/H2O/CO2 CO2/O2/N2/Ar CO2/O2/N2/Ar/H2/CO/CH4 Thermal conductivity Pure CO2 Diffusivity CO2/H2O
T (K)
P (MPa)
Phase
Gaps
NA 280.00–523.00 < 297.00, > 673.00 280.00–343.15 < 298.00, > 473.00 280.00–343.15 < 293.00, > 673.00 229.00–455.37 < 291.00 280.00–343.15 < 293.00, > 673.00 280.00–343.15 < 273.00, > 313.00 274.00–449.00 218.00–1620.00 243.00–423.00 not 295.00 293.00–353.00 218.00–1620.00 243.00–423.00 218.00–1620.00 243.00–423.00
NA < 81.100 not 0.100 8.750–48.290 not 0.100 8.900–53.790 NA 1.000–172.400 > 0.300 8.730–48.260 > 2.500
NA L. + G.(Sc.) L. L.(Sc.) L. L.(Sc.) L. L. + G.(Sc.) L. L.(Sc.) L.
No gaps
7.750–50.390 > 30.000 < 100.000 0–50.000 1.000–150.000 – – 0–50.000 1.000–150.000 0–50.000 1.000–150.000
L.(Sc.) NA L. L. + G. L. + G.(Sc.) NA L. L. + G. L. + G.(Sc.) L. + G. L. + G.(Sc.)
Previously identified gaps [8] New data [83]
NA 219.00–751.00
NA < 69.000
L. L. + G.
No gaps
Previously identified gaps [8] New data [35,36]
352.00–1620.00 352.00–473.00
0.400–50.000 0.400–45.000
NA L.
T > 473.00 K
Previously identified gaps New data [22,31,79,80] Previously identified gaps New data [22] Previously identified gaps New data [22] Previously identified gaps New data [22,81,82] Previously identified gaps New data [22] Previously identified gaps New data [22] Previously identified New data [34] Previously identified New data [72] Previously identified New data [33] Previously identified New data [32] Previously identified New data [22,32]
[8] [8] [8] [8] [8] [8]
gaps [8] gaps [8] gaps [8] gaps [8] gaps [8]
T < 280.00 K, and T > 673.00 K T < 280.00 K and T > 473.00 K T < 280.00 K and T > 673.00 K T < 280.00 K T < 280.00 K and T > 673.00 K T < 273.00 K and T > 449.00 K T > 423.00 K T < 293.00 K and T > 353.00 K No gaps No gaps
activity-coefficient models (gE) has shown clear superiority in the critical region, which is particularly suitable for VLE of polar and nonpolar mixtures at low and high pressures. The E-PPR78 (Enhanced Predictive Peng-Robinson, 1978) proposed by Qian [44] for natural gas and petroleum mixtures, using Huron–Vidal excess Gibbs energy mixing rules, can be seen as the combination of PR EOS and a Van Laar type activity coefficient (gE) model under infinite pressure. Its applicability range was further extended by Xu et al. to SO2, O2 and NO [45], and COS, NH3, NO2, N2O4 and N2O [46], which covered the main components of mixtures involved CCS. A group contribution method allowing the estimation of the temperature-dependent binary interaction parameters (kij (T)) for the Soave–Redlich–Kwong equation of state (PR2SRK) [47] was used to deduce kijSRK from a known kijPR estimated from the PPR78 model. It results in a big advantage that is not necessary to re-estimate the parameters for SRK. Generally, PR2SRK and PPR78 are of comparable accuracy. A pressure-explicit EOS was derived by Demetriades et al. from the pure fluid fugacity and mixing rules without further integration, which was obtained to generalize a EOS for pure CO2 to binary mixtures with N2, O2 and H2 [48]. It was found that this EOS had a comparable or superior performance to GERG-2008 for those three CO2 mixtures. Further, an expression for the mixture fugacity for an arbitrary EOS with arbitrary mixing rules could also be deduced. The general and flexible framework will facilitate ongoing development of this customized EOS to respond to new data and computational applications. An improved Helmholtz-energy-explicit mixture model was developed for CO2/Ar by Løvseth et al. based on the new data on VLE, density and speed of sound [15]. A refit is expected when more accurate data become available since the development of EOS-CG was completed. The updated binary correlation is part of the ongoing work to an advanced multi-parameter EOS for CO2-rich mixtures and should be further developed against an extended new database of other mixtures.
700 K and pressures up to 35 MPa. Now GERG-2008 has been adopted as an ISO Standard for natural gases and implemented in the NIST REFPROP database [37,38]. The vapor-liquid equilibrium is described as accurate as density and the speed of sound [7], with the reported uncertainty of bubble/dew point pressures less than 1–2% for binary mixtures, and less than 1–3% for multi-component mixtures. However, the development of a generalized departure function about GERG-2008 is based on several important main and secondary natural gas components, which may not result in a good prediction for key mixtures related to CCS. - Equation of State for Combustion Gases and Combustion Gas like Mixtures Another new Helmholtz energy model, Equation of State (EOS) for Combustion Gases and combustion gas like mixtures (EOS-CG), has been recently developed by Gernert and Span [39] in 2016 specifically for CO2-rich mixtures typical for CCS processes. It has been implemented in TREND software package of Ruhr-University Bochum. EOS-CG uses the mathematical approach of GERG-2008 and obtains new mixing parameters against a significantly wide literature database with a full composition range. It is well proved that the EOS presents a significant improvement for thermodynamic properties of mixtures in CCS compared to Cubic EOS and GERG EOS [29,39–41]. Moreover, its flexible and powerful mathematical structure could be adopted with minor alterations for new models, which could also show great performance. - Other Models An advanced cubic EOS, Peng-Robinson (PR) + residual Helmholtz energy-based model (PR + EOS/a E,Wilson ), was developed based on the res combination of PR and the residual part of the Wilson excess Helmholtz energy model [13,42,43]. This combination of the strengths of EOS and 5
Applied Energy 255 (2019) 113789
H. Li, et al.
Table 6 Available models for thermodynamic properties. Mixtures
CO2/N2
Models
PR
BWR PT LK SRK RK Predictive SRK 3P1T GERG 2004 Duan96 PR-Penelousx SRK-Peneloux Improved SRK RKS RKSP BWRS LKP SAFT-VR Mie PC-SAFT EOS-CG GERG-2008
PR + EOS/a E,Wilson res Demetriades and Graham EOS CO2/O2
PR BWR PT SRK RK Predictive SRK 3P1T GERG 2004 Duan96 RKS RKSP BWRS LKP GERG-2008
PR + EOS/a E,Wilson res Demetriades and Graham EOS PC-SAFT E-PPR78
year
T and P
Accuracy (Absolute average relative deviation %) G
v
Refs.
L
T (K)
P (MPa)
VLE
v
1990 2009 2014 2007 1990 2009 1983 1994 2009 2009 2007 2009 2004 2007 1996 2009 2009 2009 2014 2014 2014 2014 2017 2014 2017 2015 2016 2012 2014 2015 2016 2017 2016
220.00–270.00 193.00–363.00 273.00–293.00 216.00–363.00 220.00–270.00 193.00–363.00 220.00–270.00 220.00–273.00 193.00–363.00 193.00–363.00 216.00–363.00 193.00–363.00 90.00–450.00 216.00–363.00 < 2000.00 220.00–347.00 220.00–347.00 220.00–347.00 273.00–293.00 273.00–293.00 273.00–293.00 273.00–293.00 225.00–673.00 273.00–293.00 225.00–673.00 298.15–423.15 223.00–303.00 60.00–700.00 273.00–293.00 298.15–423.15 213.00–473.00 218.00–303.00 273.00–304.00
< 15.800 0.100–14.300 1.000–20.000 0.520–14.500 < 15.800 0.100–14.300 0.600–16.700 2.000–12.000 0.100–14.300 0.100–14.300 0.520–14.500 0.500–14.000 < 35.000 0.520–14.500 < 2500.000 0.100–14.300 0.100–14.300 0.100–14.300 1.000–20.000 1.000–20.000 1.000–20.000 1.000–20.000 4.000–800.000 1.000–20.000 4.000–800.000 11.000–31.000 < 18.000 < 70.000 1.000–20.000 11.000–31.000 1.000–19.900 1.000–16.700 < 16.000
2.1–3.3 1.22–6.04 – 2.7–9.7 1.6–3.2 2.32–10.82 3–3.9 – 1.32–11.28 5.25–14.17 1.4–16.2 3.32–25.75 1.0–3 2.2–10.4 – – – – – – – – 0.99–5.43 – 1.73–7.32 – 0.04–0.63 1.0–3.0 – – 0.76–2.85 0.08–4.22 –
– 1.58–13.02 2.0 0.8–9.2 – 0.98–13.06 – < 5 (10–20 a) 1.5–14 1.47–14.26 0.6–9.2 – 0.2–0.5 0.5–5.7 <2 2.85–11.64 2.59–12.76 5.17–8.83 1.5 1.5 1.7 1.4 1.18b 1.9 3.19b < 0.1 – 0.1 1.3 < 0.1 – – –
– 1.74–9.43 2.0 >9 – 1.77–9.28 – < 5 (10–20 a) 4.18–10.84 4.86–11.96 >9 – 0.1–0.5 3.8–18.4 – 3.79–10.51 4.97–12.15 4.64–13.21 10.7 5.4 2.1 0.7 – 0.5 – < 0.1 – 0.1–0.5 0.1 < 0.1 – – –
[7] [7] [50] [7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [50] [50] [50] [50] [51] [50] [51] [53] [74] [37] [50] [53] [13] [42] [48]
2009 2014 2007 2009 2009 2009 2007 2009 2007 2004 1996 2014 2014 2014 2014 2014 2016 2017 2016 2014 2017 2017
193.00–363.00 273.00–293.00 216.00–363.00 193.00–363.00 193.00–363.00 193.00–363.00 216.00–363.00 193.00–363.00 216.00–363.00 90.00–450.00 < 2000.00 273.00–293.00 273.00–293.00 273.00–293.00 273.00–293.00 273.00–293.00 213.00–473.00 218.00–293.00 273.00–304.00 273.00–293.00 213.10–298.35 213.10–298.35
0.100–14.300 1.000–20.000 0.520–14.500 0.100–14.300 0.100–14.300 0.100–14.300 0.520–14.500 0.500–14.000 0.520–14.500 < 35.000 < 2500.000 1.000–20.000 1.000–20.000 1.000–20.000 1.000–20.000 1.000–20.000 1.000–19.900 0.900–14.200 < 16.000 1.000–20.000 0.555–15.000 0.555–15.000
1.22–6.04 – 2.7–9.7 2.32–10.82 1.32–11.28 5.25–14.17 1.4–16.2 3.32–25.75 2.2–10.4 1.0–3 – – – – – – 0.76–2.85 0.08–4.22 – – 7.60 6.36
1.58–13.02 1.6 0.8–9.2 0.98–13.06 1.5–14 1.47–14.26 0.6–9.2 – 0.5–5.7 0.2–0.5 <2 2.0 2.4 1.6 2.1 2.4 – – – 2.2 – –
1.74–9.43 2.1 >9 1.77–9.28 4.18–10.84 4.86–11.96 >9 – 3.8–18.4 0.1–0.5 – 9.4 5.3 2.1 0.2 0.1 – – – 1.8 – –
[7] [50] [7] [7] [7] [7] [7] [7] [7] [7] [7] [50] [50] [50] [50] [50] [13] [42] [48] [50] [52] [52]
(continued on next page)
6
Applied Energy 255 (2019) 113789
H. Li, et al.
Table 6 (continued) Mixtures
CO2/Ar
Models
Accuracy (Absolute average relative deviation %)
Refs.
P (MPa)
VLE
vG
vL
2009 2014 2007 2009 2009 2009 2007 2009 2007 2004 1996 2009 2009 2009 2014 2014 2014 2014 2014 2018
193.00–363.00 273.00–293.00 216.00–363.00 193.00–363.00 193.00–363.00 193.00–363.00 216.00–363.00 193.00–363.00 216.00–363.00 90.00–450.00 < 2000.00 220.00–347.00 220.00–347.00 220.00–347.00 273.00–293.00 273.00–293.00 273.00–293.00 273.00–293.00 273.00–293.00 213.00–299.00
0.100–14.300 1.000–20.000 0.520–14.500 0.100–14.300 0.100–14.300 0.100–14.300 0.520–14.500 0.500–14.000 0.520–14.500 < 35.000 < 2500.000 0.100–14.300 0.100–14.300 0.100–14.300 1.000–20.000 1.000–20.000 1.000–20.000 1.000–20.000 1.000–20.000 0–16.000
1.22–6.04 – 2.7–9.7 2.32–10.82 1.32–11.28 5.25–14.17 1.4–16.2 3.32–25.75 2.2–10.4 1.0–3 – – – – – – – – – 0.042–3.270
1.58–13.02 1.8 0.8–9.2 0.98–13.06 1.5–14 1.47–14.26 0.6–9.2 – 0.5–5.7 0.2–0.5 <2 2.85–11.64 2.59–12.76 5.17–8.83 1.8 1.7 1.6 1.6 2.3 0.016
1.74–9.43 2.2 >9 1.77–9.28 4.18–10.84 4.86–11.96 >9 – 3.8–18.4 0.1–0.5 – 3.79–10.51 4.97–12.15 4.64–13.21 7.4 3.3 2.1 0.6 0.6 1.052–1.570
[7] [50] [7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [50] [50] [50] [50] [50] [15]
2015 2016 2017 2014 2015 2016 2016 2017
298.15–423.15 273.15–323.15 257.00–291.00 273.00–293.00 298.15–423.15 273.15–323.15 213.00–473.00 223.00–299.00
11.000–31.000 < 9.000 2.400–6.000 1.000–20.000 11.000–31.000 < 9.000 1.000–19.900 1.500–14.700
– – 0.35 – – – 0.76–2.85 0.08–4.22
< 0.5 0.18 0.37 1.8 < 0.5 0.95 – –
< 0.5 – – 0.5 < 0.5 – – –
[53] [41] [14] [50] [53] [41] [13] [42]
PR BWR PT SRK RK Predictive SRK 3P1T PR-Penelousx SRK-Peneloux Improved SRK PC-SAFT E-PPR78 An improved Helmholtz-energy-explicit mixture model EOS-CG
2009 2007 2009 2009 2009 2007 2009 2009 2009 2009 2017 2017 2017
193.00–363.00 216.00–363.00 193.00–363.00 193.00–363.00 193.00–363.00 216.00–363.00 193.00–363.00 220.00–347.00 220.00–347.00 220.00–347.00 263.15–333.21 263.15–333.21 273.00–353.00
0.100–14.300 0.520–14.500 0.100–14.300 0.100–14.300 0.100–14.300 0.520–14.500 0.500–14.000 0.100–14.300 0.100–14.300 0.100–14.300 0.200–9.060 0.200–9.060 < 42.000
1.22–6.04 2.7–9.7 2.32–10.82 1.32–11.28 5.25–14.17 1.4–16.2 3.32–25.75 – – – 3.61 3.05 –
1.58–13.02 0.8–9.2 0.98–13.06 1.5–14 1.47–14.26 0.6–9.2 – 2.85–11.64 2.59–12.76 5.17–8.83 – – 1.6
1.74–9.43 >9 1.77–9.28 4.18–10.84 4.86–11.96 >9 – 3.79–10.51 4.97–12.15 4.64–13.21 – – 0.2
[7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [52] [52] [18]
2017 2018
313.15–373.15 263.15–304.21
< 30.000 < 20.000
1.67–6.30 0.88–2.07
8.25 2.91
5.33 0.73
[2] [3]
PR
2002 2009 2007 2002 2009 2002 2009 2009 2007 2009 1996 2002 2009 2002 2009 2009 2017 2017 2012 2016
250.00–450.00 193.00–363.00 216.00–363.00 250.00–450.00 193.00–363.00 250.00–450.00 193.00–363.00 193.00–363.00 216.00–363.00 193.00–363.00 < 2000.00 250.00–450.00 220.00–347.00 250.00–450.00 220.00–347.00 220.00–347.00 249.00–500.00 249.00–500.00 60.00–700.00 273.00–353.00
0–20.000 0.100–14.300 0.520–14.500 0–20.000 0.100–14.300 0–20.000 0.100–14.300 0.100–14.300 0.520–14.500 0.500–14.000 < 2500.000 0–20.000 0.100–14.300 0–20.000 0.100–14.300 0.100–14.300 1.500–60.000 1.500–60.000 < 70.000 < 41.000
– 1.22–6.04 2.7–9.7 – 2.32–10.82 – 1.32–11.28 5.25–14.17 1.4–16.2 3.32–25.75 – – – – – – 0.99–5.43 1.73–7.32 1.0–3.0 –
1.26 (2.76b) 1.58–13.02 0.8–9.2 1.02 (2.26b) 0.98–13.06 0.51 (2.79b) 1.5–14 1.47–14.26 0.6–9.2 – <2 1.39 (3.24b) 2.85–11.64 0.65 (2.89b) 2.59–12.76 5.17–8.83 1.18b 3.19b 0.1 1
2.81 1.74–9.43 >9 2.16 1.77–9.28 9.23 4.18–10.84 4.86–11.96 >9 – – 3.53 3.79–10.51 5 4.97–12.15 4.64–13.21 – – 0.1–0.5 1
[7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [7] [51] [51] [37] [40]
PR
Duan96 PR-Penelousx SRK-Peneloux Improved SRK RKS RKSP BWRS LKP PC-SAFT An improved Helmholtz-energy-explicit mixture model EOS-CG
GERG-2008
PR + EOS/a E,Wilson res
CO2/H2S
T and P T (K)
BWR PT SRK RK Predictive SRK 3P1T GERG 2004
CO2/SO2
year
BWR PT SRK SRK RK Predictive SRK 3P1T Duan96 PR-Penelousx PR-Penelousx SRK-Peneloux Improved SRK SAFT-VR Mie PC-SAFT GERG-2008
(continued on next page)
7
Applied Energy 255 (2019) 113789
H. Li, et al.
Table 6 (continued) Mixtures
Models
year
T and P
Accuracy (Absolute average relative deviation %)
Refs.
T (K)
P (MPa)
VLE
vG
vL
1990 2009 2018 1990 2009 1983 1994 2009 2018 2009 2009 2006 2009 2009 2009 2018 2018 2012 2013 2017
220.00–270.00 193.00–363.00 293.13–303.15 220.00–270.00 193.00–363.00 220.00–270.00 220.00–273.00 193.00–363.00 293.13–303.15 193.00–363.00 193.00–363.00 245.00–383.00 220.00–347.00 220.00–347.00 220.00–347.00 293.13–303.15 293.13–303.15 60.00–700.00 304.21 219.00–301.00
< 15.800 0.100–14.300 5.720–7.930 < 15.800 0.100–14.300 0.600–16.700 2.000–12.000 0.100–14.300 5.720–7.930 0.100–14.300 0.500–14.000 0.100–350.000 0.100–14.300 0.100–14.300 0.100–14.300 5.720–7.930 5.720–7.930 < 70.000 0.100–20.000 1.100–8.500
2.1–3.3 1.22–6.04 0.34–0.55 1.6–3.2 2.32–10.82 3–3.9 / 1.32–11.28 0.38–0.58 5.25–14.17 3.32–25.75 3–9.3 – – – 0.18–0.43 0.42–0.52 1.0–3.0 – 0.08–4.22
– 1.58–13.02 – – 0.98–13.06 – < 5 (10–20)a 1.5–14 – 1.47–14.26 – – 2.85–11.64 2.59–12.76 5.17–8.83 – – 0.1 0.4–1.1 –
– 1.74–9.43 – – 1.77–9.28 – < 5 (10–20)a 4.18–10.84 – 4.86–11.96 – – 3.79–10.51 4.97–12.15 4.64–13.21 – – 0.1–0.5 0.4–1.1 –
[7] [7] [38] [7] [7] [7] [7] [7] [38] [7] [7] [7] [7] [7] [7] [38] [38] [37] [24] [42]
2004 1996 2012 2017 2017
90.00–450.00 < 2000.00 60.00–700.00 273.15–323.15 220.00–280.00
< 35.000 < 2500.000 < 70.000 < 6.000 0.900–93.000
1.0–3 – 1.0–3.0 – 0.08–4.22
0.2–0.5 <2 0.1 0.4 –
0.1–0.5 – 0.1–0.5 – –
[7] [7] [37] [27] [42]
2016
273.00–304.00
< 16.000
–
–
–
[48]
PR + EOS/a E,Wilson res
2004 1996 2018 2012 2013 2017
90.00–450.00 < 2000.00 253.00–298.00 60.00–700.00 304.21, 308.15 223.00–283.00
< 35.000 < 2500.000 < 13.000 < 70.000 0.100–20.000 0.800–14.200
1.0–3 – – 1.0–3.0 – 0.08–4.22
0.2–0.5 <2 1.4 0.1 0.4–1.1 –
0.1–0.5 / – 0.1–0.5 0.4–1.1 –
[7] [7] [16] [37] [24] [42]
CO2/n-alkanes
GERG 2004 GERG-2008
2004 2012
90.00–450.00 60.00–700.00
< 35.000 < 70.000
1.0–3 1.0–3.0
0.2–0.5 0.1
0.1–0.5 0.1–0.5
[7] [37]
CO2/H2O
PR-HV EOS-CG
2017 2017
273.00–478.00 273.00–478.00
0.100–60.800 0.100–60.800
4.5 8.0
– –
2.8 0.6
[54] [54]
CO2/NO
PC-SAFT E-PPR78
2017 2017
232.93–273.02 232.93–273.02
1.483–11.486 1.483–11.486
7.82 4.84
– –
– –
[52] [52]
CO2/NO2 (N2O4)
SAFT
2008
298.00–328.00
–
0.003–2.2
–
–
[7]
CO2/Ar/N2
EOS-CG GERG-2008
2017 2017
268.00–303.00 268.00–303.00
< 23.000 < 23.000
0.5–3.5 0.5–3.4
0.5 0.5
0.5 0.5
[29] [29]
CO2/Ar/H2
EOS-CG GERG-2008
2017 2017
268.00–303.00 268.00–303.00
< 23.000 < 23.000
0.5–3.5 0.5–3.4
0.5 0.5
0.5 0.5
[29] [29]
CO2/N2/O2
PR + EOS/a E,Wilson res
2017
233.00,273.00
4.000–15.000
1.0–4.4
–
–
[43]
CO2/CH4/N2
PR + EOS/a E,Wilson res
2017
233.00,273.00
4.000–15.000
1.0–4.4
–
–
[43]
CO2/CH4
PR
PT LK SRK RK 3P1T SRK–HV PR-Penelousx SRK-Peneloux Improved SRK UMR-PRU PC-SAFT GERG-2008
PR + EOS/a E,Wilson res CO2/H2
GERG 2004 Duan96 GERG-2008
PR + EOS/a E,Wilson res Demetriades and Graham EOS CO2/CO
a b
GERG 2004 Duan96 EOS-CG GERG-2008
: In/near the critical area. : In the supercritical area.
SAFT was, on average, more accurate than the others. However, when a binary interaction parameter was fitted, all model correlations were of comparable accuracy. It reveals that it is not necessary that the more complex models, such as PC-SAFT, will have increased accuracy. Therefore, when there is lack of experimental data, PC-SAFT is favorable. On the contrary, when experimental data are available and the binary interaction parameter can be well fitted, the Cubic EOS is the first choice. PR, RKS, RKSP, BWRS, LKP, PC-SAFT and GERG2004/2008 were compared by Mazzoccoli et al. [50] for the density of CO2/N2, CO2/O2 and CO2/Ar under pipeline transport conditions, and new binary interaction parameters were regressed except for GERG. The AARDs of those 7 models about liquid density are 2.2%, 7.4%, 3.3%, 2.1%, 0.6%, 0.6% and 0.5% for CO2/Ar, 2.0%, 10.7%, 5.4%, 2.1%, 0.7%, 0.5% and 0.1% for CO2/N2, 2.1%, 9.4%, 5.3%, 2.1%, 0.2%, 1.8% and 0.1% for
3.1.2. Model evaluation As shown in Table 6, many models have been evaluated for predicting the thermodynamic properties of CO2 mixtures. The work conducted after 2011 has been summarized below. Even though the evaluation results about the performance of different EOSs have not pointed to one particular EOS, which is superior to others, the evaluated accuracy provides a good guideline regarding model selection. Petropoulou et al. [38] compared four EOSs, including SRK, PR, PCSAFT and PR EOS with Universal Mixing Rule (UMR-PRU) for the VLE of CO2/CH4. Results showed that UMR-PRU has the lowest deviation with an absolute average relative deviation (AARD) of 0.18% for the bubble point pressure and 0.43% for CO2 mole fraction of the vapor phase. Diamantonis et al. [49] evaluated RK, SRK, PR, SAFT and PC-SAFT for VLE of CO2 mixtures including CH4, N2, O2, SO2, Ar, and H2S. PC8
Applied Energy 255 (2019) 113789
H. Li, et al.
Table 7 Available models for transport properties. Mixtures
Viscosity Pure CO2
CO2/N2
Models
T and P T (K)
P (MPa)
AARD (%)
Refs.
[8]
L. + G.
Empirical (Emp.)
200.00–1500.00
0.100–100.000
Fenghour and Wakeham Bahadori and Vuthaluru Heidaryan et al.
1998 2010 2011
L. L. Sc.
Emp. Emp. Emp.
200.00–1500.00 260.00–450.00 310.00–900.00
< 300.000 10.000–70.000 7.500–101.400
G.:5 L.:7 ± 0.3- ± 5.0 1.1 1.7
Hirschfelder Wilkes equation
1948 1950
G. G.
Chapman–Enskog (CE) CE
G.
Emp.
G.
Corresponding State (CS)
G. G.
CS Helmholtz free energy theory (HE)
293.00–303.00 296.00–303.00 293.00 298.00–873.00 – 298.00–873.00 298.00–873.00 298.00–873.00 289.00 298.00–873.00
– – – 0.100–6.000 – 0.100–6.000 – 0.100–6.000 2.000–12.000 0.100–6.000
0.1 0.5 1.7 2.0 1.3–3.6 2.8 1.0 1.3 0–7.8 1.4
[8] [8] [8] [67] [8] [67] [8] [67] [8] [67]
G.
CE
G. G.
CE + CS Emp. CS HE
296.00–303.00 298.00–674.00 298.00–674.00 298.00–674.00
– 0.100 – 0.100
1.9 2.0 0.3 2.8 1.3 1.4
[8] [67] [8] [67]
G. G.
CE CS
G.
CE Emp. HE
293.00–303.00 298.00–873.00 293.00&303.00 293.00&303.00
– – 0.100–2.600 0.100–2.600
0.1 1. 1.3 2.0 2.8 1.4
[8] [8] [67] [67]
298.00–353.00 298.00–353.00 238.00–308.00 298.00–353.00 217.00–500.00 298.00–353.00 289.00
– – – – 1.000–15.000 – 0.100
3.5 2 <1 3.5 2.0 <2 1.8–3.0
[8] [8] [8] [8] [67] [8] [8]
Hanley EH Wilkes equation Boltzmann DS KRW EH Hirschfelder KRW law Wilke DS EH CO2/SO2
Type
1990
KRW law
CO2/Ar
Phase
Vesovic et al.
Dean and Stiel
CO2/O2
Year
Herning-Zipperer Chapman-Enskog Hirschfelder Wilkes equation Brokaw Canonically angle–average pair potential energy function
2017 1965 2017 1972 2017 1976 2017 1950 2017 1977 2017
1948 1972 2017 2017
1936 1939 1948 1950 2017 1965 1971
G. G. G. G.
Emp. CE CE CE
G. G.
CE CE
[8] [55] [31]
CO2/H2O
Runberg and Nissan Arrhenius type function DS KRW EH Wilke
1949 1996 2017
L. L. G.
Emp. Emp. Emp. CS HE CE
273.00–278.00 293.00–333.00 217.00–500.00
0–30.000 – 1.000–15.000
<1 1 2.8 1.3 1.4 2.0
[8] [8] [67]
CO2/CH4
Wilkes equation Dean and Stiel DeWitt and Thodos KRW law
1950 1965 1966 1972
G. G. G. G.
CE Emp. Emp. CS
298.00 – 323.00–473.00 298.00–873.00
– – – –
<1 1.3–3.6 1.8 1
[8] [8] [8] [8]
CO2/H2
Hirschfelder
1948
G.
CE
Wilkes equation
1950
G.
CE
299.00–550.00 288.00 296.00–303.00 500.00–1100.00
– 0.100 – 0.300
2–3 <1 0.6 <8
[8] [8] [8] [8]
CO2/H2O/NaCl
Kumagai and Yokoyama Bando
1999 2004
L. L.
Emp. Emp.
273.00–278.00 303.00–333.00
0.100–30.000 10.000–20.000
1.3 5
[8] [8]
MDEA, DMEA, DEEA, MAPA/ CO2/H2O CO2/O2/H2
NRTL-DVIS correlation
2017
L.
Excess Gibbs energy (GE)
293.00–353.00
–
< 5–6
[33]
Wilkes equation
1950
G.
CE
296.00–303.00
–
1.8
[8]
CO2/O2/N2
Wilkes equation
G.
CE
G.
– – –
G.
298.00–873.00
–
0.8 2.0 1.3 1.4 2.8 1
[8] [67] [67]
1972
CS HE Emp. CS
296.00–303.00 317.00–1161.00 317.00–1161.00
CO2/CH4/N2
KRW EH DS KRW law
1950 2017 2017
[8]
(continued on next page)
9
Applied Energy 255 (2019) 113789
H. Li, et al.
Table 7 (continued) Mixtures
CO2/Ar/N2
Models
KRW law
Year
Phase
Type
T and P
AARD (%)
Refs.
T (K)
P (MPa)
298.00–873.00 298.00–873.00 298.00–873.00
– – –
1 1.3 1.4 2.8 2.0
[8] [67] [67]
1972 2017 2017
G.
CS
G.
HE Emp. CE
2018
L. + G. + Sc.
Extended correspondingstates (ECS), CS, CS2, Residual viscosity theory
243.00–423.00
1.000–150.000
3.8, 4.6, 5.3, 9.2
[32]
Thermal conductivity Pure CO2 Jarrahian and Heidaryan Amooey CSA-LSSVM model ANFIS model GP
2012 2014 2015 2016 2017
Sc. Sc. G. + L. G. + L. + Sc. Sc.
Emp. Emp. Emp. Emp. Emp.
310.00–960.00 290.00–800.00 293.50–474.31 293.65–961.50 293.65–961.05
7.400–210.000 – 0.100–93.100 0.100–127.800 0.100–127.800
2.7 2.7 0.8 2.6 2.3
[59] [60] [62] [63] [61]
CO2/N2
Wassiljewa + Lindsay-Bromley Aij
1950
G.
Semi–Emp.
Enskog Hirschfelder
1951 1957
G. G.
Rigorous kinetic theory (RKT) RKT
1958 2017 1964 1983 1988 2017
G.
RKT
G. G. G. G.
RKT CS Emp. Hirschfelder’s equation Wassiljewa’s equation Emp. HE
– 0.100–300.000 0.100 – – – – 0.100–300.000 – 0.900–30.800 0.900–30.800 0.100–300.000
−3~-1 < 30 3.4 10.0 6.4–7.8 4 4.6 5.4 2(≤500 K) 6 5 7.3 5.4 4.9 3.5
[8] [8] [8] [8]
Mason and Saxena
642.00–961.00 348.00 323.00–623.00 294.00–1000.00 323.16 – 323.00–961.00 273.00–2000.00 300.00–1000.00 302.00–470.00 302.00–470.00 273.00–2000.00
273.00–1047.00 369.00–370.00 369.00–370.00
– – –
2.1 4.9 7.3 5.4 3.5 5.4
[8] [67] [67]
EH DS Wilkes equation CO2/O2/N2/Ar CO2/alkane CO2/O2/N2/Ar/ H2/CO/CH4
CO2-SUPERTRAPP, CO2-Pedersen, CO2-CS2, CO2-LBC
Monchick Ely and Hanley Johns WD KM Cheung EH CO2/O2
Cheung WD KM EH MS
1962 2017 2017
G.
Emp.
G.
Hirschfelder’s equation Wassiljewa’s equation HE RKT
[8] [67] [8] [8] [8] [67]
CO2/SO2
Wassiljewa Wassiljewa + Lindsay-Bromley Aij Hirschfelder
1904 1950 1957
G. G. G.
Semi–Emp. Semi–Emp. RKT
323.00–373.00 323.00–373.00 323.00& 373.00
– – –
0.5 −1.2–2.5 0–3
[8] [8] [8]
CO2/H2
Wassiljewa + Lindsay-Bromley Aij Hirschfelder
1950 1957
G. G.
Semi–Emp. RKT
1975 1978 1983
G. G. G.
Emp. RKT Emp.
– – – 0.850–7.500 – – –
−0.2–8.4 2.2–3.5 5–8 > 0.3 1 5 0.4
[8] [8]
Andreev and Mal’ter Mason Kestin
273.00–298.00 273.16 258.00–473.00 300.00 273.00 & 893.00 – 300.00
[8] [8] [8]
Wassiljewa + Lindsay-Bromley Aij Mason and Saxena Tondon and Saxena
1950 1950 1958 1968
G. G. G. L.
Semi–Emp. Semi–Emp. RKT Emp.
338.00 298.00–333.00 298.00–333.00 338.00
– – – –
1.4 10 10 2.2
[8] [8] [8] [8]
CO2/CH4
Wassiljewa + Mason–Saxena Rosenbaum and Thodos Hellmann and Bich
1958 1969 2016
G. G. G.
Semi-Emp. Emp. Improved kinetic theory
298.00–308.00 333.00–433.00 293.00–303.00
0–9.000 3.300–6.900 –
<5 2 < 1.2
[8] [8] [64]
CO2/Ar
Wassiljewa + Mason–Saxena Hirschfelder Kestin WD KM EH MS Cheung
1958 1957 1982 2017
G. G. G. G.
Semi-Emp. RKT Emp. Hirschfelder’s equation Wassiljewa’s equation HE RKT Emp.
298.00–308.00 273.00–473.00 300.00 273.00–473.00
0–9.000 – – 0.100–11.000
<5 3 0.5 7.3 5.4 3.5 5.4 4.9
[8] [8] [8] [67]
CO2/N2O
Kestin Hirschfelder Cheung
1984 1957 1962
G. G. G.
Emp. RKT Emp.
300.00 300.00–750.00 273.00–1047.00
– – –
0.7 −2–9 2.1
[8] [8] [8]
CO2/H2O
CO2/O2N2 Diffusivity
(continued on next page)
10
Applied Energy 255 (2019) 113789
H. Li, et al.
Table 7 (continued) Mixtures
CO2/Ar
CO2/O2
Models
Year
Phase
RKT
1954
G.
Fuller–Schettler–Giddings
1964 1966
G.
RKT
1960
G.
Type
T and P
AARD (%)
Refs.
T (K)
P (MPa)
Modified–Buckingham potential Lennard–Jones potential Emp.
276.00–317.00
–
Inconsistent
[8]
194.80–1200.00
0.100
−3.3–14.4
[8] [8]
273.00–293.00
0.100
Within the experimental error
[8] [8] [8] [8]
Fuller–Schettler–Giddings
1966
G.
Lennard–Jones potential Exponential repulsion Point center of repulsion Modified–Buckingham potential Emp.
300.00–1500.00
0.100
−2.4–4.7
[8]
CO2/N2
Fuller–Schettler–Giddings
1966
G.
Emp.
194.80–1200.00 300.00–1500.00
0.100 0.100
−3.3–14.4 −2.4–4.7
[8]
CO2/CO
RKT
G.
–
300.00–1500.00
0.100
1.3 7.3 −2.4–4.7
[8]
G.
Lennard–Jones potential Wilke–Lee Emp.
296.10
Fuller–Schettler–Giddings
1964 1955 1966
[8]
Wilke–Chang
1955
L.
Semi-Emp.
Othmer–Thakar Stokes–Einstein Fuller–Schettler–Giddings
1960 1960 1966
L. L. G.
Semi-Emp. Hydrodynamic theory Emp.
AArrhenius–type
1986 1996 2016
G.
Emp.
279.00–338.00 291.00–348.00 298.00–328.00 279.00–338.00 298.00–328.00 194.80–1200.00 300.00–1500.00 298.00–328.00
– – 0.400 – 0.400 0.100 0.100 0.400
L.
Emp.
323.15–1023.15
200.000–1000.000
< 11 −20 5 < 11 5 −3.3–14.4 20.9 1.7 1.0 2.6
[8] [8] [8] [8] [8] [8] [8] [8] [8] [65]
1966
G.
Emp.
194.80–1200.00 300.00–1500.00 315.20–343.90
0.100 0.100 0.100
−3.3–14.4 −2.4–4.7 < 0.5
[8] [8] [8]
Canonically angle–average pair potential energy function Improved kinetic theory Improved kinetic theory
263.00–473.00
0.100
3
[8]
293.00–303.00 293.00–303.00
– –
< 1.2 < 1.2
[64] [64]
1954
CO2/H2O
A generalized Speedy–Angel correlation Fuller–Schettler–Giddings
CO2/SO2
RKT
1971
G.
CH4/CO2 H2S/CO2
Hellmann and Bich Hellmann and Bich
2016 2016
G. G.
density of CO2/Ar [41]. Results showed that the AARDs were around 0.95% and 0.18% for GERG-2008 and EOS-CG respectively. It was concluded that the improvement of EOS-CG is attributed to the employment of a binary specific departure function. GERG-2008, EOS-CG, PR and gSAFT were evaluated for VLE and density of CO2/Ar/N2 by Ke et al. [29]. Results showed that EOS-CG had the best accuracy on both phase equilibrium and density with an AARD of 0.5%. EOS-CG has also been used to calculate the VLE and density of CO2/SO2 [2,3]. The results showed that the AARD for density, dew point and bubble point were 0.54%, 2.07% and 0.88% in the temperature range of 263–304 K. However, high deviations (25.6% for vapor density and 9.46% for liquid density) were found at 304.21 K, which was due to the close proximity to the critical point of the mixture. Aasen et al. [54] conducted a comprehensive comparison of models for VLE and density of CO2/H2O, including Cubic EOSs (PR and SRK) (with quadratic/Wonge-Sandler/Hurone-Vidal mixing rules), PC-SAFT, Perturbed-chain polar SAFT (PCP-SAFT), Cubic plus association SRK (CPA-SRK), corresponding states models with various reference fluids, GERG-2008 and EOS-CG. Those models were all fitted to the same data and tested outside of the temperature and pressure range used in the fitted interaction parameters. It was found that PR with the Huron–Vidal mixing rule and volume shift and EOS-CG gave the best performance for CO2/H2O, with AARD of 4.5% and 8.0% for phase equilibrium, and 2.8% and 0.6% for density. was compared with the corresponding cubic EOS PR + EOS/a E,Wilson res by Lasala et al. [13] for the VLE of CO2/N2. Results showed that PR highly over-predicted the critical point, while PR + EOS/a E,Wilson can res accurately capture it. Generally speaking, EOS-CG has a better performance on both VLE and density than GERG and Cubic EOSs except for the critical region.
CO2/O2, respectively. Perez et al. [51] investigated SRK, PR, PC-SAFT and SAFT-VR Mie for VLE and density of 108 binary mixtures mainly including CO2, CH4, C2H6, N2, and H2S. Results showed that SAFT-VR Mie had the best performance for both the VLE and density. The work of Diamantonis et al. [49] made similar conclusion that the performances of the four studied EOSs were close for VLE when the regressed binary interaction parameter was used. Xu et al. compared E-PPR78 and PC-SAFT [52] for VLE of 77 binary mixtures containing CO2, SO2, O2, NO, H2O and hydrocarbons. For CO2/SO2, CO2/O2 and CO2/NO, the AARDs of PC-SAFT with one temperature-independent binary interaction parameter and E-PPR78 are 3.61%, 7.60%, 7.82% and 3.05%, 6.36%, 4.84% respectively. GERG-2008 was used to calculate the density of CO2/N2 and CO2/ Ar. The AARD against the data measured by Yang et al. [53] were smaller than 0.1% and 0.5%. It is mainly because no binary specific departure function was available for the (CO2/Ar) system in the GERG2008. GERG-2008 was also tested for the phase equilibrium of CO2/Ar by Løvseth et al. [15]. Results showed that in general, the calculated results agreed well with the measured data at high CO2 mole fractions. However, it predicted a significantly higher critical pressure and lower CO2 mole fraction at and above 243 K. GERG-2008 has been compared with classical Cubic EOSs (PR, SRK and VPT) with volume correction/translation models for the density of CO2/H2S by Nazeri et al. [40]. The results showed that GERG-2008 had the best accuracy with the AARD of 1.1%. High accuracy was also obtained for the derived properties. For instance, the AARDs were 1.1% and 4.8% for compressibility factor and isobaric heat capacities of CO2/ H2S, respectively. GERG-2008 was also compared with EOS-CG by Yang et al. for the 11
Applied Energy 255 (2019) 113789
H. Li, et al. E,Wilson Compared to Cubic EOSs, PR + EOS/ ares shows a significant improvement in the critical region on VLE. When the binary interaction parameters are well-tuned, Cubic EOSs can show accuracy similar to those models with complicated structures, such as PC-SAFT.
for 300 < T/K < 700, 2.5% for 200 < T/K < 300 and 700 < T/ K < 1200, and 3.5% for 150 < T/K < 200.
3.2. Transport property models
The model of Hellmann et al. [64] can also be applied for the calculation of diffusivity of CH4/CO2, CH4/H2S and H2S/CO2. For diffusivity, the deviation reported is 2.0% for 300 < T/K < 700, 2.5% for 200 < T/K < 300 and 700 < T/K < 1200, and 3.5% for 150 < T/ K < 200 too. Moultos et al. [65,66] proposed a new phenomenological equation, a generalized form of the Speedy–Angel relationship, for correlating the diffusivity of CO2/H2O based on atomistic molecular dynamics (MD) simulations. It was a function of pressure and temperature and was found to be in good agreement with experimental data either at 283.15 K < T < 623.15 K (0.1 MPa < P < 100.0 MPa) or at 323.15 K < T < 1023.15 K (200 MPa < P < 1000 MPa) [65] through the combination of specific force fields. The correlation can be useful for engineering calculations by extrapolating experimental data outside the measurement range.
- Diffusivity
3.2.1. Newly developed models - Viscosity Bahadori and Vuthaluru [55] proposed a new empirical correlation for the viscosity of pure CO2, which was an exponential function of pressure and temperature. With simple algebraic equations and few parameters, the AARD was found to be 1.1% against the reported data. The empirical coefficients could be easily tuned when new and more accurate measurements are available, which may serve as a convenient tool for engineers. Lohrenz-Bray-Clark (LBC), originally developed for modeling natural gas and hydrocarbons mixtures [56], was tuned by Nazeri et al. [32] to predict the viscosity of CO2-rich mixtures based on the residual viscosity theory (CO2-LBC). The empirical correlative model was a fourth-order polynomial equation in the reduced density, and PR with the CO2 volume correction (PR-CO2 EOS) was used to calculate the mixture density. It has been concluded that CO2-LBC shows better prediction than original LBC, especially for density correction. Nazeri and Chapoy [32] proposed three predictive models for the viscosity of CO2-rich mixtures based on the corresponding states (CS) theory by using new reference fluids. CO2-Pedersen model (CS model with one reference fluid), originally developed by Pedersen [57], was modified by changing the reference fluid from methane to CO2 [22,32]. Similarly, CO2-CS2 model (CS model with two reference fluids) was modified by changing the reference fluids from methane and n-decane to methane and CO2. Moreover, the SUPERTRAPP model was modified by changing reference fluid from propane to CO2. The NRTL-DVIS correlation was proposed by Pinto and Svendsen [58] to calculate the liquid viscosity of mixtures. The adopted mixing rule was a function of excess Gibbs energy, which was specifically represented using the NRTL model. The adjustable parameters were fitted by the particle swarm optimization (PSO) algorithm and they had a temperature dependency.
3.2.2. Model evaluation Wilke, KRW, DS, and EH were evaluated by Tan et al. for viscosity of binary and multi-component CO2 mixtures with non-condensable gas impurities N2, O2 and Ar in cryogenic process [67], and the AARDs were 2.0%, 1.3%, 2.8% and 1.4% respectively. On average, KRW showed a better performance than the others. However, different models showed different capabilities under different working conditions. EH model was recommended at higher pressures; DS model was recommended at temperature lower than 283 K with an AARD of 1.0%; and for temperature higher than 283 K at atmospheric pressure, KRW model was the first choice. CO2-Pedersen, CO2-SUPERTRAPP, CO2-CS2 and CO2-LBC were compared by Nazeri et al. [32] for the viscosity of CO2/O2/N2/Ar, CO2/ O2/N2/Ar/H2/CO/CH4 and CO2/C2H6/C3H8/C4H10, of which the experiment was conducted at temperatures from 243 to 423 K and pressures from 1 to 155 MPa in gas, liquid and supercritical regions. The AARDs were 3.8%, 4.6%, 5.3% and 9.2% respectively for the three multi-component CO2-rich mixtures. Overall, CO2-Pedesen showed the best accuracy, especially with an AARD of 2.8% for binary CO2 mixtures containing O2, Ar, N2, H2, CO and CH4 [22]. Under the conditions of CO2 cryogenic process, Tan et al. [67] also compared WD, KM, MS, Cheung and EH for thermal conductivity of CO2/N2, CO2/O2 and CO2/Ar and the AARDs were 7.3%, 5.4%, 5.4%, 4.9% and 3.5%, respectively. In general, EH should be recommended for predicting thermal conductivity. Cheung model was recommended for temperature higher than 273 K at atmospheric pressure. For pressures higher than atmospheric pressure, KM model was preferred at pressure lower than 3 MPa, and EH should be employed at pressure higher than 3 MPa. The performances of transport property models are more dependent on the mixtures and T and P conditions, compared to the thermodynamic property models. The newly developed viscosity models, such as CO2-LBC and CO2-Pedersen, are superior to others due to their good accuracy and wide application ranges. The models based on Rigorous kinetic theory have an advantage in extrapolation, particularly for thermal conductivity and diffusivity due to the lack of available data.
- Thermal conductivity Many empirical models are developed for the thermal conductivity of pure CO2. The correlation by Jarrahian and Heidaryan [59] was a function of the pressure and temperature based on the multiple regression analysis technique. Amooey [60] correlated thermal conductivity as a function of density and temperature by minimizing the sum of square of errors. A novel correlation by Rostami et al. [61] served as a powerful equation generator based on genetic programming (GP) mathematical strategy and it provided much flexibility. They are all simple without a large number of parameters. Shams et al. [62] proposed an intelligent modeling approach, Least-Square Support Vector Machine modeling with Coupled Simulated Annealing (CSALSSVM), which set linear equations using support vectors. Another predictive model by Tatar et al. [63] was based on Adaptive NeuroFuzzy Inference System (ANFIS) and trained by the combination of Hybrid and Particle Swarm Optimization (PSO) methods. It was found to be accurate for the prediction of 1042 experimental data from the literature. For CO2 mixtures, the classical trajectory method was used by Hellmann et al. [64] for dilute gas thermal conductivity of CH4/CO2, CH4/H2S and H2S/CO2. The latest intermolecular potential energy surfaces based on highly accurate quantum-chemical were employed in the calculation. The deviation reported on thermal conductivity is 2.0%
4. Impacts of properties on CCS More works have been carried out to investigate the impacts of thermo-physical properties of CO2 mixtures on the design and operation of CCS processes since our previous review carried out in 2016 [10]. The impacts have been updated and summarized in Table 8. 12
Applied Energy 255 (2019) 113789
[69] [69] [67] 217.00–500.00 K 1.000–15.000 MPa 217.00–500.00 K 1.000–15.000 MPa 217.00–500.00 K 1.000–15.000 MPa
Nookuea et al. [68] studied the impact of liquid and gas phase densities on the design parameters of absorber for chemical absorption, including column diameter, packing height and annual capital cost. Results showed that the density of gas had the most significant effect on the column diameter. A 10% underestimation of gas density may result in an increase of about 6% of the column diameter. For the packing height, the density of liquid had the most significant effect. A 10% underestimation of the liquid density may result in an increase of 8% of the packing height. For the annual capital cost (AC), an underestimation of the liquid density of 10% led to a $1.4 million overestimation of the cost for the absorption column. A sensitivity study was conducted by Tan et al. [69] to analyze the impacts of density on the volume and AC of a plate-fin multi-stream heat exchanger. Compared to thermal conductivity, heat capacity and viscosity, density resulted in the smallest impact. - Heat capacity
CO2/CH4, CO2/C2H6, CO2/CH4, CO2/C2H6, CO2/Ar, CO2/O2
[67] 217.00–500.00 K 1.000–15.000 MPa CO2/Ar, CO2/O2, CO2/N2/Ar, CO2/N2/O2, CO2/N2/
The impact of heat capacity on the volume and AC of the heat exchanger in CO2 cryogenic process was also evaluated by Tan et al. [69]. The result showed that overestimating heat capacity would result in the reduction of the dimension and the property impacts underestimated were bigger than those overestimated. It was also found that heat capacity had more significant influence than viscosity. 4.2. Impacts of transport properties
Volume design and annual capital cost of heat exchanger Volume design and annual capital cost of heat exchanger Volume of the plate-fin multi-stream heat exchanger
The viscosity impacts on column diameter, packing height and annual capital cost were also studied by Nookuea et al. for the absorber in chemical absorption [68]. It was found that a 10% underestimation of liquid phase viscosity can result in 0.34%, 7.06% and 5.3% underestimations of the column diameter, packing height and AC respectively. The AC of the absorption tower was affected by the viscosity of liquid phase more obviously than that of the gas phase. The impact of viscosity on the volume and AC of the multi-stream heat exchanger in the cryogenic separation process was evaluated by Tan et al. [67,69]. It was found that the overestimation of viscosity led to the overestimation of the volume. That is because heat transfer coefficient decreases and pressure drop increases when viscosity increases, both resulting in the increase of volume. - Thermal conductivity
CO2 capture in cryogenic process
The impact of thermal conductivity on the volume and AC of the multi-stream heat exchanger in the cryogenic separation process was also studied by Tan et al. [67,69]. Compared to viscosity, the volume and capital cost were more sensitive to thermal conductivity. Overestimating and underestimating the thermal conductivity by 10% would make the volume change from 14.6 m3 to 13.5 m3 and 16.0 m3, respectively. For AC, +20% and −20% deviations of thermal conductivity can correspond to variations of −14.2% and 20.6% [69]. 4.3. Discussions
Thermal conductivity
CO2 capture in cryogenic process
CO2 capture in cryogenic process CO2 capture by chemical absorption Heat capacity Viscosity
- Density
CO2/N2, O2/Ar CO2/N2, CO2/N2, CO2/N2, of the plate-fin multi-stream heat exchanger
[69] [69] [68] 217.00–500.00 K 1.000–15.000 MPa 217.00–500.00 K 1.000–15.000 MPa / CO2/N2, CO2/CH4, CO2/C2/H6, CO2/N2, CO2/CH4, CO2/C2/H6, Aqueous amine solution with CO2 loading design and annual capital cost of heat exchanger design and annual capital cost of heat exchanger diameter, packing height, capital cost of the absorber
[68] / Aqueous amine solution with CO2 loading
Column unit Volume Volume Column unit Volume CO2 capture by chemical absorption
diameter, packing height, capital cost of the absorber
Influenced parameters
Density
4.1. Impacts of thermodynamic properties
- Viscosity
Processes
Working Condition Mixture Impact Property
Table 8 Impacts of thermo-physical property on CCS.
Refs.
H. Li, et al.
According to the property impacts, the key properties have been ranked regarding different CCS processes, as shown in Table 9. It is clear that the importance of properties can be different for different processes. Meanwhile, based on the performance of existing models summarized in Section 3, the possible ranges of AARD are also given in Table 9. By comparing the importance of the properties and the 13
14
219.00–423.00
0–11.000
0.100–20.000
Condensation and liquefaction
Transport
223.00–350.00
219.00–423.00
0–11.000
293.00–343.00
273.00–673.00
Compression and pumping
0.010–5.000
Physical adsorption
217.00–500.00
0.100–3.500
1.000–15.000
Physical absorption
288.00–357.00
T (K)
Membrane separation
0.100–0.110
P (MPa)
Working condition
Chemical absorption
Process
Table 9 Important properties for different processes of CCS.
[68] [68] [68] [68] [68] [68] [68] – –
–
–
[69] [69] [10] [10] [10]
5% variation can change the AC by 1.8% 5% variation can change the AC by 1.3%
viscosity density
[69]
18% variation can change the temperature drop by 20% 5% variation can change the temperature drop by 3% 20% variation results in negligible temperature drop
5% variation can change the AC by 2.2%
heat
[69]
[10] – – – –
5–15% variation can change the compression work by 3.8–6.5% – – – – 5% variation can change the AC by 4.5%
[10]
2% variation can change the pump efficiency by 12%
– – – – – –
annual capital cost (AC) by 5.9% AC by 5.3% AC by 4.2% AC by 2.5% AC by 2.3% AC by 0.1% AC by 0.05%
– – – – – –
the the the the the the the
– – – – – –
change change change change change change change
– – – – – –
can can can can can can can
– – – – – –
variation variation variation variation variation variation variation
Refs.
– – – – – –
10% 10% 10% 10% 10% 10% 10% – –
Property impacts
thermal
1 Liquid density 2 Liquid heat capacity 3 Liquid viscosity and thermal conductivity Phase equilibrium*
1 Gas and liquid conductivity 2 Gas and liquid capacity 3 Gas and liquid 4 Gas and liquid
Liquid heat capacity and liquid density Gas density Gas heat capacity* Gas thermal conductivity* Gas viscosity* Phase equilibrium*
Gas density* Gas viscosity* Gas heat capacity* Phase equilibrium* Gas thermal conductivity* Gas diffusivity*
Gas density* Gas viscosity* Gas heat capacity* Phase equilibrium* Gas thermal conductivity* Gas diffusivity*
Liquid density * Phase equilibrium* Liquid heat capacity* Gas and liquid viscosity* Gas and liquid diffusivity* Gas and liquid thermal conductivity*
1 Liquid density 2 Liquid viscosity 3 Liquid diffusivity 4 Gas density 5 Liquid heat capacity 6 Gas diffusivity 7 Gas viscosity Phase equilibrium* Gas and liquid thermal conductivity*
Property ranking according to the impacts
0.003–25.75
0.1–20 – 1–9.2
0.1–9.2 0.016–20
–
0.2–10
0.016–20 – 0.2–10 0.1–8 0.003–25.75
0.1–20
0.016–20 0.1–8 – 0.003–25.75 0.2–10 0.5–20.91
0.016–20 0.1–8 – 0.003–25.75 0.2–10 0.5–20.91
0.1–20 0.003–25.75 – 0.1–9.2 0.5–20.91 0.2–10
0.1–20 1–9.2 2.6–20 0.016–20 – 0.5–20.91 0.1–8 0.003–25.75 1–9.2
Property model accuracy (AARD %)
(continued on next page)
Models on liquid density and models on phase equilibrium
Models on thermal conductivity of gas and liquid
Models on density of liquid and gas and models on phase equilibrium
Models on phase equilibrium and models on gas diffusivity
Models on phase equilibrium and models on gas diffusivity
Models on phase equilibrium and models on diffusivity of gas and liquid
Models on density of liquid and gas and models on diffusivity of liquid and gas
Priority of model development
H. Li, et al.
Applied Energy 255 (2019) 113789
Applied Energy 255 (2019) 113789
0.003–25.75 –
5. Conclusions
Models on gas density and models on phase equilibrium
– –
Gas and liquid diffusivity* Gas and liquid thermal conductivity* Phase equilibrium* Gas and liquid heat capacity*
– –
0.5–20.91 0.2–10
0.1–9.2 [10]
1 Gas and liquid density
This paper updated the progress in studies on thermodynamic and transport properties of CO2 mixtures, including vapor-liquid equilibrium, density, viscosity, thermal conductivity and diffusion coefficient. The latest experimental data and theoretical models published since 2011 have been collected and reviewed. For experimental data, some knowledge gaps have been bridged. For example, more measurements were conducted for the phase equilibrium of CO2/Ar, CO2/NO2(N2O4) and ternary mixtures, the density of CO2/O2, CO2/COS, CO2/H2 and CO2/CO, and the liquid viscosity of CO2/O2, CO2/Ar, CO2/H2 and CO2/O2/N2/Ar/H2/CO/CH4. There are, nevertheless, still some gaps. For example, no data are available yet about the phase equilibrium of CO2/COS and CO2/NH3, the density of CO2/NH3, gaseous CO2/O2 and CO2/NO2 (N2O4), and transport properties of CO2/H2S, CO2/COS and CO2/NH3. Previous works have mainly focused on the major impurities. However, in order to obtain more accurate properties, more attention needs to be paid to the minor components. Regarding the model development, new models and methods were proposed. The performance of the existing models has been summarized and compared, which provides a good guideline regarding model selection. There have also been some debates that developing morecomplex models to further improve the accuracy may not be necessary since simple models with well-tuned empirical parameters can also show good performance. In addition, the increased number of experimental data has opened a new door for property modeling. Methods of data analysis, such as machine learning and artificial neural network, have been adopted. Such methods, which do not rely on a deep understanding of the fundamental theory, can make the model development easier. Nevertheless, data processing techniques require more experimental data about the properties of CO2 mixtures, especially the multicomponent mixtures. By analyzing thermo-physical property impacts, the important properties were identified and ranked. By comparing the importance of the properties and the accuracy of existing models, suggestions were given regarding the development of property models that should be prioritized. However, clear knowledge gaps still exist, for example, no quantitative results are available yet about the property impacts on physical absorption, physical adsorption and membrane separation, which are important guidelines to experimental measurements and model development.
* No quantitative results are available.
261.00–393.00 10.000–50.000 Storage
T (K) P (MPa)
2 Gas and liquid viscosity
0.016–20 [10]
50% variation can change the normalized storage capacity by 50% (1% variation of gas density can change the enhanced oil recovery rate (EOR) by 9%) 50% variation can change the normalized storage capacity by 50% (1% variation of gas viscosity can change the EOR by 6%) – –
Priority of model development Property model accuracy (AARD %) Refs. Property impacts Property ranking according to the impacts Working condition Process
Table 9 (continued)
accuracy of models, the priority of model development can be determined. For example, for chemical absorption, the liquid density was identified as the most important property and the existing models also show a big range of AARD. Therefore, developing more accurate models for liquid density should be prioritized. In addition, even though the liquid viscosity was also identified as a property that has more impacts than the liquid diffusivity, since the available models of liquid viscosity have a smaller and lower range of AARD, it is more crucial to develop more accurate models for liquid diffusivity than for liquid viscosity. For physical absorption, physical adsorption and membrane separation, even though the properties that can affect those processes have been identified, no quantitative results about the impacts are available yet. Therefore, they cannot be ranked and more works are needed to quantitatively study the impacts. Heat capacity has also been identified as an important property for some processes, such as compression and pumping. Empirical correlations based on polynomial equations are commonly used to calculate heat capacity, which usually show high accuracy.
– –
H. Li, et al.
Acknowledgement The authors gratefully acknowledge the financial supports from 15
Applied Energy 255 (2019) 113789
H. Li, et al.
National Natural Science Foundation of China (No. 51776140).
[28] Yang X, Wang Z, Li Z. accurate density measurements on ternary mixtures (carbon dioxide + nitrogen + argon) at temperatures from (323.15 to 423.15) K with pressures from (3 to 31) MPa using a single-sinker densimeter. J Chem Eng Data 2015;60:3353–7. [29] Ke J, Suleiman N, Sanchez-Vicente Y, Murphy TS, Rodriguez J, Ramos A, et al. The phase equilibrium and density studies of the ternary mixtures of CO2 + Ar + N2 and CO2 + Ar + H2, systems relevance to CCS technology. Int J Greenhouse Gas Control 2017;56:55–66. [30] Nazeri M, Chapoy A, Burgass R, Tohidi B. Measured densities and derived thermodynamic properties of CO2 -rich mixtures in gas, liquid and supercritical phases from 273 K to 423 K and pressures up to 126 MPa. J Chem Thermodyn 2017;111:157–72. [31] Heidaryan E, Hatami T, Rahimi M, Moghadasi J. Viscosity of pure carbon dioxide at supercritical region: Measurement and correlation approach. J Supercrit Fluids. 2011;56:144–51. [32] Nazeri M, Chapoy A, Burgass R, Tohidi B. Viscosity of CO2-rich mixtures from 243 K to 423 K at pressures up to 155 MPa: New experimental viscosity data and modelling. J Chem Thermodyn 2018;118:100–14. [33] Pinto DDD, Johnsen B, Awais M, Svendsen HF, Knuutila HK. Viscosity measurements and modeling of loaded and unloaded aqueous solutions of MDEA, DMEA DEEA and MAPA. Chem Eng Sci 2017;171:340–50. [34] McBride-Wright M, Maitland GC, Trusler JPM. Viscosity and density of aqueous solutions of carbon dioxide at temperatures from (274 to 449) K and at pressures up to 100 MPa. J Chem Eng Data 2014;60:171–80. [35] Lu W, Guo H, Chou IM, Burruss RC, Li L. Determination of diffusion coefficients of carbon dioxide in water between 268 and 473K in a high-pressure capillary optical cell with in situ Raman spectroscopic measurements. Geochim Cosmochim Acta 2013;115:183–204. [36] Cadogan SP, Maitland GC, Trusler JPM. Diffusion coefficients of CO2 and N2 in water at temperatures between 298.15 K and 423.15 K at pressures up to 45 MPa. J Chem Eng Data 2014;59:519–25. [37] Kunz O, Wagner W. The GERG-2008 wide-range equation of state for natural gases and other mixtures: an expansion of GERG-2004. J Chem Eng Data 2012;57:3032–91. [38] Petropoulou E, Voutsas E, Westman SF, Austegard A, Stang HGJ, Løvseth SW. Vapor - liquid equilibrium of the carbon dioxide/methane mixture at three isotherms. Fluid Phase Equilib 2018;462:44–58. [39] Gernert J, Span R. EOS–CG: A Helmholtz energy mixture model for humid gases and CCS mixtures. J Chem Thermodyn 2016;93:274–93. [40] Nazeri M, Chapoy A, Valtz A, Coquelet C, Tohidi B. Densities and derived thermophysical properties of the 0.9505 CO2 + 0.0495 H2S mixture from 273 K to 353 K and pressures up to 41 MPa. Fluid Phase Equilib 2016;423:156–71. [41] Yang X, Richter M, Ben Souissi MA, Kleinrahm R, Span R. Vapor-Phase (p, ρ, T, x) behavior and virial coefficients for the binary mixture (0.05 argon + 0.95 carbon dioxide) over the temperature range from (273.15 to 323.15) K with pressures up to MPa. J Chem Eng Data 2016;61:2676–81. [42] Lasala S, Chiesa P, Privat R, Jaubert J-N. Modeling the thermodynamics of fluids treated by CO2 capture processes with Peng-Robinson + residual helmholtz energybased mixing rules. Ind Eng Chem Res 2017;56:2259–76. [43] Lasala S, Chiesa P, Privat R, Jaubert J-N. Measurement and prediction of multiproperty data of CO2-N2-O2-CH4 mixtures with the “Peng-Robinson + residual Helmholtz energy-based” model. Fluid Phase Equilib 2017;437:166–80. [44] W QJ. Développement du modèle E-PPR78 pour prédire les équilibres de phases et les grandeurs de mélange de systèmes complexes d’intérêt pétrolier sur de larges gammes de températures et de pressions Vandoeuvre-les-Nancy. 2011. [45] Xu X, Privat R, Jaubert J-N. Addition of the sulfur dioxide group (SO2), the oxygen group (O2), and the nitric oxide group (NO) to the E-PPR78 model. Ind Eng Chem Res 2015;54:9494–504. [46] Xu X, Lasala S, Privat R, Jaubert J-N. E -PPR78: a proper cubic EoS for modelling fluids involved in the design and operation of carbon dioxide capture and storage (CCS) processes. Int J Greenhouse Gas Control 2017;56:126–54. [47] Jaubert J-N, Privat R. Relationship between the binary interaction parameters (kij) of the Peng-Robinson and those of the Soave–Redlich–Kwong equations of state: application to the definition of the PR2SRK model. Fluid Phase Equilib 2010;295:26–37. [48] Demetriades TA, Graham RS. A new equation of state for CCS pipeline transport: calibration of mixing rules for binary mixtures of CO2 with N2, O2 and H2. J Chem Thermodyn 2016;93:294–304. [49] Diamantonis NI, Boulougouris GC, Mansoor E, Tsangaris DM, Economou IG. Evaluation of cubic, SAFT, and PC-SAFT equations of state for the vapor-liquid equilibrium modeling of CO2 mixtures with other gases. Ind Eng Chem Res 2013;52:3933–42. [50] Mazzoccoli M, Bosio B, Arato E, Brandani S. Comparison of equations-of-state with P–ρ–T experimental data of binary mixtures rich in CO2 under the conditions of pipeline transport. J Supercrit Fluids 2014;95:474–90. [51] Perez AG, Coquelet C, Paricaud P, Chapoy A. Comparative study of vapour-liquid equilibrium and density modelling of mixtures related to carbon capture and storage with the SRK, PR, PC-SAFT and SAFT-VR Mie equations of state for industrial uses. Fluid Phase Equilib 2017;440:19–35. [52] Xu X, Privat R, Jaubert J-N, Lachet V, Creton B. Phase equilibrium of CCS mixtures: equation of state modeling and Monte Carlo simulation. J Supercrit Fluids 2017;119:169–202. [53] Yang X, Richter M, Wang Z, Li Z. Density measurements on binary mixtures (nitrogen + carbon dioxide and argon + carbon dioxide) at temperatures from (298.15 to 423.15) K with pressures from (11 to 31) MPa using a single-sinker densimeter. J Chem Thermodyn 2015;91:17–29.
References [1] Global CCS Institute. The global status of CCS. Summary report; 2018 < https:// www.globalccsinstitute.com/resources/global-status-report/ > . [2] Gimeno B, Artal M, Velasco I, Blanco ST, Fernández J. Influence of SO2 on CO2 storage for CCS technology: evaluation of CO2/SO2 co-capture. Appl Energy 2017;206:172–80. [3] Gimeno B, Artal M, Velasco I, Fernández J, Blanco ST. Influence of SO2 on CO2 transport by pipeline for carbon capture and storage (CCS) technology: evaluation of CO2/SO2 co-capture. Energy Fuels 2018;32:8641–57. [4] Yan J, Zhang Z. Carbon capture, utilization and storage (CCUS). Appl Energy 2019;235:1289–99. [5] Wang R, Liu S, Wang L, Li Q, Zhang S, Chen B, et al. Superior energy-saving splitter in monoethanolamine-based biphasic solvents for CO2 capture from coal-fired flue gas. Appl Energy 2019;242:302–10. [6] Budinis S, Krevor S, Dowell NM, Brandon N, Hawkes A. An assessment of CCS costs, barriers and potential. Energy Strat Rev 2018;22:61–81. [7] Li H, Jakobsen JP, Wilhelmsen Ø, Yan J. PVTxy properties of CO2 mixtures relevant for CO2 capture, transport and storage: review of available experimental data and theoretical models. Appl Energy 2011;88:3567–79. [8] Li H, Wilhelmsen Ø, Lv Y, Wang W, Yan J. Viscosities, thermal conductivities and diffusion coefficients of CO2 mixtures: review of experimental data and theoretical models. Int J Greenhouse Gas Control 2011;5:1119–39. [9] Munkejord ST, Hammer M, Løvseth SW. CO2 transport: data and models – a review. Appl Energy 2016;169:499–523. [10] Tan Y, Nookuea W, Li H, Thorin E, Yan J. Property impacts on carbon capture and storage (CCS) processes: a review. Energy Convers Manage 2016;118:204–22. [11] Ahmad M, Gernert J, Wilbers E. Effect of impurities in captured CO2 on liquid–vapor equilibrium. Fluid Phase Equilib 2014;363:149–55. [12] Tsankova G, Richter M, Madigan A, Stanwix PL, May EF, Span R. Characterisation of a microwave re-entrant cavity resonator for phase-equilibrium measurements and new dew-point data for a (0.25 argon + 0.75 carbon dioxide) mixture. J Chem Thermodyn 2016;101:395–404. [13] Lasala S, Chiesa P, Privat R, Jaubert J-N. VLE properties of CO2 – Based binary systems containing N2, O2 and Ar: experimental measurements and modelling results with advanced cubic equations of state. Fluid Phase Equilib 2016;428:18–31. [14] Tsankova G, Stanwix PL, May EF, Richter M. Densities, dielectric permittivities, and dew points for (argon + carbon dioxide) mixtures determined with a microwave reentrant cavity resonator. J Chem Eng Data 2017;62:2521–32. [15] Løvseth SW, Austegard A, Westman SF, Stang HGJ, Herrig S, Neumann T, et al. Thermodynamics of the carbon dioxide plus argon (CO2 + Ar) system: an improved reference mixture model and measurements of vapor-liquid, vapor-solid, liquidsolid and vapor-liquid-solid phase equilibrium data at the temperatures 213–299 K and pressures up to 16 MPa. Fluid Phase Equilib 2018;466:48–78. [16] Westman SF, Austegard A, Stang HGJ, Løvseth SW. Vapor-liquid equilibrium data for the carbon dioxide and carbon monoxide (CO2 + CO) system at the temperatures 253, 273, 283 and 298 K and pressures up to 13 MPa. Fluid Phase Equilib 2018;473:37–49. [17] Coquelet C, Valtz A, Arpentinier P. Thermodynamic study of binary and ternary systems containing CO2+impurities in the context of CO2 transportation. Fluid Phase Equilib 2014;382:205–11. [18] Nazeri M, Chapoy A, Valtz A, Coquelet C, Tohidi B. New experimental density data and derived thermophysical properties of carbon dioxide – sulphur dioxide binary mixture (CO2 - SO2) in gas, liquid and supercritical phases from 273 K to 353 K and at pressures up to 42 MPa. Fluid Phase Equilib 2017;454:64–77. [19] Camy S, Letourneau JJ, Condoret JS. Experimental study of high pressure phase equilibrium of (CO2+NO2/N2O4) mixtures. J Chem Thermodyn 2011;43:1954–60. [20] Tenorio M-J, Parrott AJ, Calladine JA, Sanchez-Vicente Y, Cresswell AJ, Graham RS, et al. Measurement of the vapour–liquid equilibrium of binary and ternary mixtures of CO2, N2 and H2, systems which are of relevance to CCS technology. Int J Greenhouse Gas Control 2015;41:68–81. [21] Mantovani M, Chiesa P, Valenti G, Gatti M, Consonni S. Supercritical pressure–density–temperature measurements on CO2–N2, CO2–O2 and CO2–Ar binary mixtures. J Supercrit Fluids 2012;61:34–43. [22] Al-Siyabi I. Effect of impurities on CO2 stream properties. 2013. [23] Deering CE, Saunders MJ, Commodore JA, Marriott RA. The volumetric properties of carbonyl sulfide and carbon dioxide mixtures from T = 322 to 393 K and p = 2.5 to 35 MPa: application to COS hydrolysis in subsurface injectate streams. J Chem Eng Data 2016;61:1341–7. [24] Rivas C, Blanco ST, Fernández J, Artal M, Velasco I. Influence of methane and carbon monoxide in the volumetric behaviour of the anthropogenic CO2: experimental data and modelling in the critical region. Int J Greenhouse Gas Control 2013;18:264–76. [25] Tsankova G, Richter M, Stanwix PL, May EF. Densities and dielectric permittivities for (carbon monoxide + carbon dioxide) mixtures determined with a microwave reentrant cavity resonator. J Chem Thermodyn 2019;129:114–20. [26] Sanchez-Vicente Y, Drage TC, Poliakoff M, Ke J, George MW. Densities of the carbon dioxide+hydrogen, a system of relevance to carbon capture and storage. Int J Greenhouse Gas Control 2013;13:78–86. [27] Ben Souissi MA, Kleinrahm R, Yang X, Richter M. Vapor-phase (p, ρ, T, x) behavior and virial coefficients for the binary mixture (0.05 hydrogen + 0.95 carbon dioxide) over the temperature range from (273.15 to 323.15) K with pressures up to 6 MPa. J Chem Eng Data 2017;62:2973–81.
16
Applied Energy 255 (2019) 113789
H. Li, et al.
[54] Aasen A, Hammer M, Skaugen G, Jakobsen JP, Wilhelmsen Ø. Thermodynamic models to accurately describe the PVTxy-behavior of water/carbon dioxide mixtures. Fluid Phase Equilib 2017;442:125–39. [55] Bahadori A, Vuthaluru HB. Predictive tool for an accurate estimation of carbon dioxide transport properties. Int J Greenhouse Gas Control 2010;4:532–6. [56] Lohrenz J, Bray BG, Clark CR. Calculating viscosities of reservoir fluids from their compositions. J Petrol Technol 1964;16:1171–6. [57] Pedersen KS, Fredenslund A. An improved corresponding states model for the prediction of oil and gas viscosities and thermal conductivities. Chem Eng Sci 1987;42:182–6. [58] Pinto DDD, Svendsen HF. An excess Gibbs free energy based model to calculate viscosity of multicomponent liquid mixtures. Int J Greenhouse Gas Control 2015;42:494–501. [59] Jarrahian A, Heidaryan E. A novel correlation approach to estimate thermal conductivity of pure carbon dioxide in the supercritical region. J Supercrit Fluids 2012;64:39–45. [60] Amooey AA. A simple correlation to predict thermal conductivity of supercritical carbon dioxide. J Supercrit Fluids 2014;86:1–3. [61] Rostami A, Arabloo M, Ebadi H. Genetic programming (GP) approach for prediction of supercritical CO2 thermal conductivity. Chem Eng Res Des 2017;122:164–75. [62] Shams R, Esmaili S, Rashid S, Suleymani M. An intelligent modeling approach for prediction of thermal conductivity of CO2. J Nat Gas Sci Eng 2015;27:138–50. [63] Tatar A, Barati-Harooni A, Najafi-Marghmaleki A, Norouzi-Farimani B, Mohammadi AH. Predictive model based on ANFIS for estimation of thermal conductivity of carbon dioxide. J Mol Liq 2016;224:1266–74. [64] Hellmann R, Bich E, Vesovic V. Cross second virial coefficients and dilute gas transport properties of the (CH4 + CO2), (CH4 + H2S), and (H2S + CO2) systems from accurate intermolecular potential energy surfaces. J Chem Thermodyn 2016;102:429–41. [65] Moultos OA, Tsimpanogiannis IN, Panagiotopoulos AZ, Economou IG. Self-diffusion coefficients of the binary (H2O + CO2) mixture at high temperatures and pressures. J Chem Thermodyn 2016;93:424–9. [66] Moultos OA, Tsimpanogiannis IN, Panagiotopoulos AZ, Economou IG. Atomistic molecular dynamics simulations of CO2 diffusivity in H2O for a wide range of temperatures and pressures. J Phys Chem B 2014;118:5532–41. [67] Tan Y, Nookuea W, Li H, Thorin E, Yan J. Evaluation of viscosity and thermal conductivity models for CO2 mixtures applied in CO2 cryogenic process in carbon capture and storage (CCS). Appl Therm Eng 2017;123:721–33. [68] Nookuea W, Tan Y, Li H, Thorin E, Yan J. Impacts of thermo-physical properties of gas and liquid phases on design of absorber for CO2 capture using monoethanolamine. Int J Greenhouse Gas Control 2016;52:190–200. [69] Tan Y, Nookuea W, Li H, Thorin E, Yan J. Impacts of thermos-physical properties on plate-fin multi-stream heat exchanger design in cryogenic process for CO2 capture. Appl Therm Eng 2019;149:1445–53. [70] Mondéjar ME, Martín MC, Span R, Chamorro CR. New (p, ρ, T) data for carbon
[71]
[72]
[73]
[74]
[75]
[76]
[77]
[78]
[79]
[80]
[81]
[82]
[83]
17
dioxide – nitrogen mixtures from (250 to 400)K at pressures up to 20MPa. J Chem Thermodyn 2011;43:1950–3. Mondéjar ME, Villamañán RM, Span R, Chamorro CR. Accurate (p, ρ, T) data for two new (carbon dioxide+nitrogen) mixtures from (250 to 400)K at pressures up to 20MPa. J Chem Thermodyn 2012;48:254–9. Chapoy A, Nazeri M, Kapateh M, Burgass R, Coquelet C, Tohidi B. Effect of impurities on thermophysical properties and phase behaviour of a CO2-rich system in CCS. Int J Greenhouse Gas Control 2013;19:92–100. Fandiño O, Trusler JPM, Vega-Maza D. Phase behavior of (CO2+O2) and (CO2+N2) at temperatures between (218.15 and 303.15)K at pressures up to 15MPa. Int J Greenhouse Gas Control 2015;36:78–92. Westman SF, Stang HGJ, Løvseth SW, Austegard A, Snustad I, Størset SØ, et al. Vapor–liquid equilibrium data for the carbon dioxide and nitrogen (CO2 + N2) system at the temperatures 223, 270, 298 and 303 K and pressures up to 18 MPa. Fluid Phase Equilib 2016;409:207–41. Westman SF, Stang HGJ, Løvseth SW, Austegard A, Snustad I, Ertesvåg IS. Vaporliquid equilibrium data for the carbon dioxide and oxygen (CO2 + O2) system at the temperatures 218, 233, 253, 273, 288 and 298 K and pressures up to 14 MPa. Fluid Phase Equilib 2016;421:67–87. Yang X, Wang Z, Li Z. Accurate density measurements on a binary mixture (carbon dioxide + methane) at the vicinity of the critical point in the supercritical state by a single-sinker densimeter. Fluid Phase Equilib 2016;418:94–9. Ben Souissi MA, Richter M, Yang X, Kleinrahm R, Span R. Vapor-phase (p, ρ, T, x) behavior and virial coefficients for the (argon + carbon dioxide) system. J Chem Eng Data 2016;62:362–9. Liu S, Zhang Y, Chi Y, Song Y, Yang M, Liu Y, et al. Density characteristics of CO2–CH4 binary mixtures at temperatures from (300 to 308.15)K and pressures from (2 to 18)MPa. J Chem Thermodyn 2017;106:1–9. Davani E, Falcone G, Teodoriu C, McCain WD. Rolling ball viscometer calibration with gas over whole interest range of pressure and temperature improves accuracy of gas viscosity measurement. Ind Eng Chem Res 2012;51:15276–81. Schäfer M, Richter M, Span R. Measurements of the viscosity of carbon dioxide at temperatures from (253.15 to 473.15)K with pressures up to 1.2MPa. J Chem Thermodyn 2015;89:7–15. Davani E, Falcone G, Teodoriu C, McCain WD. HPHT viscosities measurements of mixtures of methane/nitrogen and methane/carbon dioxide. J Nat Gas Sci Eng 2013;12:43–55. Locke CR, Stanwix PL, Hughes TJ, Johns ML, Goodwin ARH, Marsh KN, et al. Viscosity of {xCO2+(1−x)CH4} with x=0.5174 for temperatures between (229 and 348)K and pressures between (1 and 32)MPa. J Chem Thermodyn 2015;87:162–7. Harvey AHHM, Laesecke AR, Muzny CD, Perkins RA. Progress toward new reference correlations for the transport properties of carbon dioxide. The 4th International Symposium on Supercritical CO2 Power Cycles. 2014.