FABRICATION ET CARACTERISATION ACOUSTIQUE DE MICROPARTICULES POLYMERIQUES DE TRISACRYL (BIOSPHERE MEDICAL? POUR L'ELABORATION D'UN NOUVEAU PRODUIT DE CONTRASTE ULTRASONORE S LAVISSE (l), V ROUFFIAC(l), A PACI(l), P OPOLON (l), C CHAIX (2), P PÉRONNEAU (l), P REB(2), N LASSAU(1) (1) VILLEJUIF - FRANCE, (2) ROISSY- FRANCE

TRABECULAR BONE STRUCTURE OF THE CALCANEUS : COMPARISON OF HlGH RESOLUTION MR IMAGING AT 1.5T AND 3T USlNG MICROCT AS A STANDARD OF REFERENCE C PHAN(l), M MATSUURA (2), T DUNN(1). J BAUER (l), R KRUG(l), D NEWITT (1), F ECKSTEIN(3), S MAJUMDAR (1). T LINK(1) (1) SAN FRANCISCO- ETATS-UNIS, (2) MUNICH - ALLEMAGNE, (3) SALZBURG- AUTRICHE

Objectifs : Fabrication de microparticules (MP) polymériques de trisacryl de diamètres décroissants et caractérisation in vitro des propriétés acoustiques. Matériels et méthodes : Les particules ont été synthétisées par polymérisation en mini-émulsion inverse puis caractérisées sur un banc hydrodynamique de Couette couplé à une chaîne d'acquisition et de traitement des signaux ultrasonores. Pour chaque diamètre moyen (de 150 pm à 2 prn), le rehaussement ultrasonore a été quantifié à des concentrations comprises entre 0,245 et 15,625 mg/mL et enregistré pendant 30 minutes pour étudier la stabilité des MP de 2 pn. La répartition en taille a été mesurée au moyen du granulomètre BeckrnanaLS 230. Une étude de toxicité a été menée sur 30 souris avec sacrifice à JI, 57, J14 et 530. Résultats : La granulométrie des plus petites particules a présenté une dispersion quasi-monodisperse avec des diamètres inférieurs à 3 pm pour 99,9 % des MF'. Ces particules ont montré un rehaussement stable et croissant avec la concentration jusqu'à 15 dB à la dose maximale. Leur étude de toxicité n'a révélé aucune réaction inflammatoire. Conclusion : Les MF' de trisacryl présentent in vitro des propriétés acoustiques particulièrement intéressantes en cours de validation in vivo sur les tumeurs du petit animal. " Mots clés :Doppler - Expérimentation - Produits de contraste

Objectifs : To use high resolution magnetic resonance imaging (MM) performed at 1.5T and at 3T to investigate the calcaneal trabecular structure in elderly human donors and to correlate those measures with the true calcaneal bone structure obtained by MicroCT. Matériels et méthodes :Sagittal MR images of 49 human calcaneus specimens were obtained (age of donors : 79.5 rc I l years, male: female = 23:26). After spatial CO-registrationof images acquired at 1.5T and 3T, signal-to-noise-ratios and structural parameters were compared in corresponding sections. MicroCT was obtained in calcaneus cores obtained from corresponding regions. Résultats : Significantly higher correlations (p < 0.05) between structure parameters derived from 3T MRI versus MicroCT were found compared to those derived from 1.5T MRI. Quantitative analysis demonstrated significantly (p < 0.05) higher app. Trabecular number (1.84 mm-' at 3T versus 1.54 mm-' at 1.5T) and app. Bone volume fraction (0.41 versus 0.28) at 3T. Conclusion : MR imaging at 3T showed a better visualization of the trabecular bone structure than at 1.5T as demonstrated by the higher correlations of the corresponding structure parameters with MicroCT used as a standard of reference. However, trabecular dimensions were also more amplified due to increasing susceptibility artifacts. Mots clés : IRM - Os - Expérimentation

11 h 4 0

Durée : 7 minutes

QUANTIFICATION 3D DE LA PERFUSION TISSULAIRE DES TUMEURS AU COURS DU TEMPS PAR ECHOGRAPHIE-DOPPLER A BRULÉ,N ELIE, V ROUFFIAC, N DEHEZ, M LAMURAGLIA, N LASSAU, A ROCHE, P PERONNEAU VILLEJUIF - FRANCE Objectifs : Reconstruire en 3D les aspects morphologiques et fonctionnels des tumeurs par échographie-Doppler haute-fréquence. Quantifier au cours du temps la perfusion tissulaire volumique par des logiciels de perfusion et l'acquisition de signaux ultrasonores détectés linéairement (raw-data). Matériels et méthodes :Etude sur modèle tumoral murin (B16). Examens à J+7,9, 11,16,18 avec un échographe Aplio (Toshiba), sondes de 9-12MHz. Acquisition en modes B et Doppler de coupes parallèles espacées de 0,5 mm. Pour trois coupes tumorales, injection de SonoVue (Bracco). Acquisition avec logiciel de perfusion « Vascular Recognition Imaging » VRI (Toshiba) de la prise de contraste en raw data. Reconstruction 3D des tumeurs (vascularisation, perfusion) sous Amira 3D-TGS. Modélisation des courbes de perfusion et extraction des paramètres (rehaussement, temps de montée). Moyenne du rehaussement sur les sections avec normalisation par la surface considérée. Résultats :La prise de contraste calculée pour trois sections de la tumeur permet une approche volumique moyenne de la perfusion tumorale. Les valeurs des rehaussements et temps de montée obtenus diffèrent significativement selon les sections (jusqu'à 1000 %). Le rehaussement moyen volumique évolue dans le temps avec la vascularisation tumorale. Conclusion : Ce travail permet de quantifier en 3D à partir des raw data la perfusion tissulaire au cours du développement tumoral. " Mots clés : Doppler - Modèles animaux, tumeur maligne Produits de contraste